CONTRACTOR's Specification (fill in this column

ITEM only)
ITEM/DESCRIPTION PTTEPSA's Specification
NO. Preferred or Typical Specification shown where
relevant, but equivalent will be acceptable

A Land Rig/Location/Classification/Drawing/Certification
A.1 Location & Availabillity of the drilling unit
Note: Include location of rig prior to tender "window" if
different than current location
Date rig is free from prior commitment Specify Subject to availability of the Rig
Current location Specify Udon Thani, Thailand
Current rig status (drilling-idle-etc.) Specify Drilling with setting up for UBD operations
If rig idle, since when Specify
Mobilization time to Location (Myanmar Block G, Location G-1) Months 45 Days started from confirm date
Current operating company and phone number Specify APICO (Khorat) Limited / +66 2659 5809
A.2 Drilling unit information
Name of drilling unit Specify AD-2
Type and class (Shall be diesel electric driven with SCR or DC-
Specify AC / VFD
DC system or AC-VFD or Hydraulics System)
Owner Specify Asia Drilling Pte Ltd
Designer/model (incl. design upgrade/variation) Specify NOV / HongHua
Yard/builder/date of construction Specify 2010
Modifications/Refurbishment made since built Specify Brand New
Date/reason/yard Specify
Date of last in yard Specify Feb-10
Provide plan & side view schematics of drilling unit, all decks Specify
(drawings are mandatory)
Rated depth min. 4000 m. with 5" DP 7000m
Maximum allowable pull min. 750,000 lbs 1,000,000.00 lb
A.3 Average fule consumption
At rig site, normal drilling condition (m3 / day) Specify 12.0 m3/day
At Camp site (m3 / day) Specify 0.55 m3/day

Land Rig Equipment Specification Rev1 1 of 65


CONTRACTOR's Specification (fill in this column
ITEM only)
ITEM/DESCRIPTION PTTEPSA's Specification
NO. Preferred or Typical Specification shown where
relevant, but equivalent will be acceptable
A.4 Drawings
Provide Detailed Drawing of the following items:
1. General Rig & Equipment Location Layout Plan Req To be Available
2. Location Layout (incl. all pits as well as necessary
Req To be Available
foundations for heavy equipment)
3. Location Hazardous Area Layout (Fire/Explosion hazard, incl.
Req To be Available
Muster station etc.
4. Mud System (incl. detailed piping diagram and arrangement
Req To be Available
of solids control equipment)
5. SCR System where applicable (incl. block diagram) Req To be Available
6. AC Power System (incl. generator placement, block diagram
Req To be Available
and detailed drawings of main AC power lines)
7. DC Power System (incl. SCR placement, block diagram and
Req To be Available
detailed drawings of main DC power lines)
8. Drilling Engines and Compound where applicable Req To be Available
9. Noise Emission Chart to fully y operational
p rig
g and additional
Req To be Available
equipment
10. All high Pressure Surface Circulating Equipment (Mud
Pumps to Swilvel, incl. nomimal ID and working pressure rating Req To be Available
for all items
11. Wellhead & 21 1/4" -2M BOP Stack (ANN-SR-SR) Diagram
and Dimensional Drawings for Drilling of 17 1/2" (or 16") Hole Req To be Available
Sections
12. Wellhead & 13 5/8" 10M BOP Stack (ANN-DR-SR) Diagram
and Dimensional Drawings for Drilling of 12 1/4", 8"1/2 & 6- Req, specify To be Available
1/8" Hole Sections
13. Choke Manifold System incl. choke line(s), flare line(s),
location(s) of flare(s) and control panel(s), tie-in to primary Req To be Available
degasser
15. BOP Control System (incl. accumulator unit placement, all
Req To be Available
control lines, locations(s) of control panel(s)
16. Rig Water System (incl. diameter of water lines and
Req To be Available
dimensions of feeder pump(s))

Land Rig Equipment Specification Rev1 2 of 65


CONTRACTOR's Specification (fill in this column
ITEM only)
ITEM/DESCRIPTION PTTEPSA's Specification
NO. Preferred or Typical Specification shown where
relevant, but equivalent will be acceptable
17. Rig Fuel System (incl. location(s) and size(s) of rig fuel
Req To be Available
tank(s))
18. Rig Firefighting Equipment (incl. locations and dimensions
Req To be Available
of fire extinguisher(s)
A.5 Certification/classification
Certification(s) & expiry date(s) Req To be Available
Most recent survey classification report, certified by Req To be Available
Next periodic rig inspection Req As per Schedule
Detailed surveyors checklist Req
List of Certificates & Inspection Reports
Provide the following Documentation:
1. Certificates of last MPI of mast and substructure Req To be Available
2. Certificates of last MPI of travelling block, hook, crown and
Req To be Available
swivel assemblies
3. Report of last Wall thickness Test of High Pressure Mud lines
Req To be Available
and Stand pipe
4 Report of last Wall thickness Test of all Mud Tanks (side
4.
Req To be Available
walls and bottoms)
5. In case of Pressurized Fuel Tanks, last Pressurized Vessel
Req To be Available
Inspection Report
6. Last Pressurized Vessel Inspection Report for all pressure
Req To be Available
vessels in the rig air supply system
7. Last Pressurized Vessel Inspection Report for BOP Control
Req To be Available
Unit Accumulator Bottles
8. API Certification of all Well Control Components incl. last
Req To be Available
Inspection Reports for Well Control Components
9. API Certification of all BOP Hydraulic Control Lines according
Req To be Available
to API Spec. 16D
10. Full DS1 Inspection Report of all Drill String Components
Supplied by Contractor done immediatedly prior to Start of Req To be Available
Contract

Land Rig Equipment Specification Rev1 3 of 65


CONTRACTOR's Specification (fill in this column
ITEM only)
ITEM/DESCRIPTION PTTEPSA's Specification
NO. Preferred or Typical Specification shown where
relevant, but equivalent will be acceptable
11. Ex-Certificates of all Electrical Components operated inside
the explosion-hazardous Zone (15m around Wellhead and Req To be Available
complete mast)
B Rig Equipment Specifications
B.1 Mast and Substructure
B.1.1 Mast and Substructure
Make/type Specify JJ450 / 45-K
Height, clear min. 45-47 m 45 m
Width of base Specify
Width of top Specify
Gross nominal capacity 1,000,000 lbs 1,000,000 lbs
Static load rating with 8 lines Specify 680,000 lbs
Static load rating with 10 lines Specify 827,000 lbs
Static load rating with 12 lines Specify 967,000 lbs
Dynamic load rating with 8 lines Specify
Dynamic load rating with 10 lines Specify
Dynamic load rating with 12 lines Specify
80.5 MPH with full set back,
Wind loading capacity Specify
107 MPH without set back
Number of lines Specify Max 12 lines
Ladders with safety device Req Yes
Upper part of mast painted for day signalling to air navigation Req Yes
Red lights as per requlation on top of mast Req Yes
Counter balance system for rig tongs and pipe spinning tong Req Yes
Dead line guide Req Yes
Bumper blocks under crown and auto shut-off protection Req Yes
Derrick to be fitted with heavy duty, vapour tight, fluorescent
lighting system, certified for use in division 1 or division 2 areas Req Yes
as required by IP, API or other national codes.

Land Rig Equipment Specification Rev1 4 of 65


CONTRACTOR's Specification (fill in this column
ITEM only)
ITEM/DESCRIPTION PTTEPSA's Specification
NO. Preferred or Typical Specification shown where
relevant, but equivalent will be acceptable
B.1.3 Derrick independent inspection/survey
Date of lasted inspection & inspection company Req July 2013 ( Module Spec by APICO (Khorat) Limited
inventory of equipment hung in derrick and program of
Req
management the same
B.1.4 Racking Platform
Make/type
Racking platform capacity of 5" DP/HWDP 3500 m of 5" DP Yes
Racking platform capacity of DC and size 450 m of 8"DC Yes
Racking platform capacity of 9 1/2"DC DC
Air winch for working drill collars
B.1.5 Racking Arm (if fitted)
Make/type
B.1.6 Casing Stabbing Board Req
Make/type Specify JFZ-07-C, ( Hong Hua )
Operated by : (air / electrical / hydraulic) Specify Air Operated
Adjustable from/to height Specify 0 ~ 6.7
67m
B.1.7 Substructure
Make/type Specify
Height 35' (10.67 m) 9m
Width Specify 12m x 13m
Setback-capacity Specify 5200kN
Simultaneously load capacity of
Simultaneous setback - RT/hookload capacity
set back and rotary 900,000 lbs
Clear height below R/table beams min 9 m. 7.6m
Rotary static load min 750,000
Casing capacity 5200kN
lbs
complete with
1) BOP handling system with trolleys Req Yes
2) Hydraulic skidding bogie supported on subbase beams. Yes

Land Rig Equipment Specification Rev1 5 of 65


CONTRACTOR's Specification (fill in this column
ITEM only)
ITEM/DESCRIPTION PTTEPSA's Specification
NO. Preferred or Typical Specification shown where
relevant, but equivalent will be acceptable

3) Substructure suitable for cluster well drilling and skidding


Yes
over multi-well cellars with mast in erected position.
4) Spreader beams to allow easy removal and installation
Yes
during skidding operations.
5) Provision for single hole and kelly scabblard. Yes
6) The ability to drill if required the rat hole to accommodate
Yes
singles & kelly scabbard.
B.1.8 Weather Proofing
Rig floor windbreaks height Specify, if any
Derrickman windbreaks height Specify, if any
B.1.9 Pipe Racks
Racking Capacity for 5" DP (M) min. 4000 m
Racking Capacity for 3 1/2" DP (M)
Racking Capacity for 20" csg. (M)
Racking Capacity for 13 3/8" csg. (M)
Racking Capacity for 11 3/4" csg (M)
Racking Capacity for 9 5/8" csg. (m)
B2 Drawworks and Associated Equipment
B.2.1 Drawworks
Make/type Specify NOV ( USA ) / ADS-10SD
Quantity installed Specify
Rate capacity, kips Specify 1800 HP
Drive type (electric or hydraulic) Specify Electric
Auxiliary Brake/Safety current supply Specify Air Cooled Brake
Input HP min 2000 HP 1800 HP
Available (Output) horsepower
Drum barrel size & grooving Specify 30" x 55", Lebus for 1 3/8 in (3.49 cm) Dia. Rope
Catheads Specify National B-1 (pneumatic)
Crown block & floor safety systems Specify Crown O'matic
Separate fresh water cooling system Yes

Land Rig Equipment Specification Rev1 6 of 65


CONTRACTOR's Specification (fill in this column
ITEM only)
ITEM/DESCRIPTION PTTEPSA's Specification
NO. Preferred or Typical Specification shown where
relevant, but equivalent will be acceptable
B.2.2 Auxiliary Brake Req
Make Specify NOV
Model Specify
Spring-applied, air-cooled, pneumatically-released
Independent back-up system Specify
multidisc
B.2.3 Sandline (for swabbing well)
Make Specify, if any N/A
Length capacity Specify, if any
Line size/type
Braking strength
B.3 Hoisting Equipment
B.3.1 Crown block
Make/type Specify Hong Hua / TC 450
Rated capacity min 750,000 lbs 1,000,000 lbs
Number / size of sheaves Specify 7 x 60"
Sheave diameter Specify 60"
Sheave grooved for line size Specify 1 3/8"
1-3/8"
B.3.2 Travelling Block
Make/type Specify Hong Hua / YC450
Rated capacity min 750,000 lbs 1,000,000 lbs
No. of sheaves Specify 6
Sheave diameter Specify 60"
Sheave grooved for line size Specify 1-3/8"
Hook type and rating Specify DG450 / 1,000,000 lbs
When was the last inspection of travelling block + links ? Req Apr-13
B.3.3 Hook
Make/type Specify Hong Hua / DG450
Rated capacity min 750,000 lbs 1,000,000 lbs
Complete with spring assembly/hook locking device Specify Yes
B.3.4 Swivel
Make/type Specify Hong Hua / SL450-5
Static Rated capacity min 750,000 lbs 4500kN
Bearing rating (at 100 rpm) Specify

Land Rig Equipment Specification Rev1 7 of 65


CONTRACTOR's Specification (fill in this column
ITEM only)
ITEM/DESCRIPTION PTTEPSA's Specification
NO. Preferred or Typical Specification shown where
relevant, but equivalent will be acceptable
Test/working pressure 5,000 psi WP 5000 psi
C/W gooseneck and washpipe Specify 5000 psi
Minimum ID Specify 3"
C/W access fitting for wireline entry on top of gooseneck Yes/No Yes
B.3.5 Drilling Line
Size (min) Specify 1-3/8"
Type IPS or EIPS EIPS
Length (min) Specify 7,500 ft
Spool capacity Specify 7,500 ft
Fast line guide (yes/no) Yes/No Yes
Auxiliary brakemust be fitted. (yes/no) Yes/No Yes
Crown-O-Matic must be fitted. (yes/no) Yes/No Yes
Rigfloor safety device protection (traveling block limit switch,
Yes/No Yes
yes/no)
Cathead must be fitted. (yes/no) Yes/No Yes
Drilling line guide (yes/no) Yes/No Yes
B36
B.3.6 Deadline Anchor
Make/type Specify Hong Hua / JZG4
C/W weight sensor Yes/No Yes ( NOV, USA )
Built as per API standard Yes/No Yes ( NOV, USA )
Rated load capacity min 100,000 lbs 1,000,000 lbs
B.3.7 Air winches
Dedicates man-rider not included in air hoist count Specify Yes
5 ton
Air hoists on rig floor, min 2 req min. 2
3 kips capacity c/w automatic brake 3 kips
Guarded drum c/w line spooling assist Yes/No Yes
B.3.8 Man-Riding Winch
make/model Specify Ingersoll Rand (USA) / LS150RLP-E
Dedicated for lifting personnel only Yes/No Yes
Certified "Man-Rider" on rig floor, Min. 1 1
Type/size Specify Pneumatic, SWL 150 kg

Land Rig Equipment Specification Rev1 8 of 65


CONTRACTOR's Specification (fill in this column
ITEM only)
ITEM/DESCRIPTION PTTEPSA's Specification
NO. Preferred or Typical Specification shown where
relevant, but equivalent will be acceptable
B.3.9 Monkey Board Work Winch
Make Specify USA
Type Specify DM2040-10xk3-15
Capacity 1,000 lbs line pull 1,000 lbs
Wire diameter Specify 0.315"
Automatic brakes Yes/No Yes
Overload protection Yes/No Yes
Automatic spooling Yes/No
B.3.10 Camera SONY
Located in derrick with vertical and horizontal panning
controlon driller's console to monitor derrickman and top drive, Req Yes
min. 1
Number available min. 1 5 units
B.4 Rotation System
B.4.1 Rotary table
Make/type Specify Hong Hua / ZP375
Maximum opening 37"1/2 37 1/2"
37-1/2"
Driven by an independent electric motor, two speed gearbox
Yes / No Yes
and emergency chain drive-electric motor type/make.
Rated capacity (RPM) Specify 300
Input H.P 600 KW
Bushings for Company's casing sizes, plus bushing grooved to
Specify Yes
allow for DP conveyed logging wireline operations
Static load rating min. 750,000 lbs
Rotary beam load cap, tons Specify 1,000,000 lbs
Output power Specify 21,630 ft-lbs
Maximum continuous torque Specify 618 HP at 150 RPM
DenCon SMB Split Type (hinged)
B.4.2 Master Bushings (split type)
for 37 1/2" rotary table
Make Specify Varco
Type Specify MPCH

Land Rig Equipment Specification Rev1 9 of 65


CONTRACTOR's Specification (fill in this column
ITEM only)
ITEM/DESCRIPTION PTTEPSA's Specification
NO. Preferred or Typical Specification shown where
relevant, but equivalent will be acceptable
Split master bushing Specify Yes Hinged
Full range of insert bowls to suit running all casing sizes (API) Specify Yes type 1,2,3
B.4.3 Kelly Bushing
Make Specify Varco
Type Specify 27 HDP
c/w lock down assembly Specify Yes
Kelly bushing for kelly 3"1/2 DP Yes/No Yes
Kelly buhsing for kelly 5" DP Yes/No Yes
B.5 Top Drive System
Top drive rails and trolley
B.5.1
Compatible with Top drive Yes/No Yes
B.5.2 Top drive weight
Weight of top drive unit, lbs. Req 23,200 lbs

B.5.3 Top drive capabilities


Req TDS 11SA or eqvl (min) or
Req–
Manuf / model / type / HP NOV / TDS 11 SA
better
Working pressure 5,000 psi
Built as per API standard : API8-C Yes/No Yes
Load rating 1,000,000 lbs 1,000,000 lbs
min (36,500ft-lbs req low gear)
Available continuous torque Continueous torque (37,500ft-lbs @ 220 rpm )
@ 90 rpm
Maximum rotating RPM 220
Motor maximum continuous output power (HP) 800 HP 800 HP
Attach certified AMP, RPM, torque curve and calibration
Req Shall be provided during Commissioning
to drillers console.
Motor type (Electical AC or DC, or Hydraulic) Specify AC Induction, Forced air cooled
Last inspec of pipe handler, main shaft, IBOP, elevator links,
Specify Oct-12
etc.

Land Rig Equipment Specification Rev1 10 of 65


CONTRACTOR's Specification (fill in this column
ITEM only)
ITEM/DESCRIPTION PTTEPSA's Specification
NO. Preferred or Typical Specification shown where
relevant, but equivalent will be acceptable
Top drive controls
Independent controls for torque with adjustable safety limit.
B.5.4 NOV
Independent speed control with all necessary controls & safety Specify
Pannel mounted / Touch Screen
alarms.
B.5.5 Top drive make up / break out
To make up and break out drill pipe connections c/w breaker &
entry guide funnel. Elevator and links fitting device to make
connections in mouse hole & assist derrick man. To allow use Specify 3-1/2" ~ 5"
of kelly safety valve and break out above. Top drive to handle
3-1/2"
Manuf / type Specify NOV
Make-up / break out Specify Yes
Max torque Specify 55,000 ft lbs
Tilt Specify Yes
Breaker lifting device Yes/No Yes
B.5.6 Top drive safety & operating features
Top drive safety valves must be API “Type 2” to hold pressure
Yes/No Yes
from both top and bottom.
Integrated remote valve 3-1/2” ID min Yes/No Yes
Integrated remote valve working pressure min 5000 psi 5,000 psi
Lower safety valve, manual, 10ksi. Yes/No Yes, 10,000 psi
Min 2-1/2” through-bore access to pass free point & back off
Yes/No Yes
tools, etc.
Swivel ring to allow links and elevator rotation when tripping. Yes/No Yes
B.5.7 Top drive miscellaneous
Wear subs Yes/No Yes
Mud saver valve or other arrangement Yes/No Yes
Top drive cooling system Specify
Top drive Guidance system Specify Torque tube
Top drive elevators links for running drillpipe size / rate (klbs) Specify 2-5/8" x 2.91 m, 700 klbs

Land Rig Equipment Specification Rev1 11 of 65


CONTRACTOR's Specification (fill in this column
ITEM only)
ITEM/DESCRIPTION PTTEPSA's Specification
NO. Preferred or Typical Specification shown where
relevant, but equivalent will be acceptable

Top drive elevators links for running casing size / rate (klbs) Specify 3-1/2" x 3.35m, 1,000 klbs
Top drive wireline accessories kit Specify 2"
Air elevators - optional (list if rig is equipped) Yes/No
B.5.8 Automatic driller
Must be able to control ROP by: 1) pump pres differential or,
2) ROP. Unit will be used extensively and will be inspected Yes/No Yes
prior to rig acceptance to ensure compliance.
ROP controlled by both differential pressure and ROP limits –
Yes/No Yes
Y/N?
Manuf/type Specify NOV
Model/age Specify NOV
Describe system Specify NOV
C. Power Supply Systems
C.1 Riggppower p plant
Complete power system comprising of diesel driven generator
sets supplying DC and AC power (or alternatively using an SCR Specify AC / VFD
system)
C.1.1 Main Diesel Engines
Sufficient power for rig to be 100% functional with loss of one
unit, i.e. backream, pump, mix mud and run solid control Yes/No Yes
equipment
Manuf/type Cat 3512 or D399 or equivalent Cat 3512
Number of units 4 3
total output HP Specify 1749bhp
Can rig circulate and rotate with one engine down (show
Yes/No Yes
circulation)
Can rig POOH (with backreaming) with one engine down (show
Yes/No Yes
calculation)
Type of Fuel Diesel Diesel
At rotation speed of Equipped with spark arresters Yes/No Yes
Muffers installed Yes/No Yes

Land Rig Equipment Specification Rev1 12 of 65


CONTRACTOR's Specification (fill in this column
ITEM only)
ITEM/DESCRIPTION PTTEPSA's Specification
NO. Preferred or Typical Specification shown where
relevant, but equivalent will be acceptable
C.1.2 Generator
In the drilling mode sufficient power must be available to
control and power simultaneously two mud pumps and TDS
Specify
both at full load and the drawworks at half load with preferably
one diesel engine/generator on standby
Manuf/type Specify Caterpillar, USA / SR4B
Number of units 4 3
Rated KVA Specify 1900kVA
Max amps, continuous duty Specify 600 V/ 50 Hz / 1649 Amps
Max amps, 1 min surge Specify
C.1.3 AC distribution/transformer
Manuf/Type Specify
Input/Output Specify 600 Volts / 400 Volts
Major unit powered Specify
C.1.4 DC distribution / transformer
Manuf/Type Specify VFD System
Number of SCR units Min 4
Min. 6
C.1.5 Independent emergency generator power system
Manuf/type/starting device (air/betteries) Specify Cat C-15
Output voltage (Volts) Specify 498HP / 353KW at 1500 rpm
Max continuous Power (KVA) Specify KVA 4OO/320 KW
AC Generator frequency Specify 4OO / 23OV / 50 Hz
Services powered must include Y/N
Fire fighting equipment Yes/No Yes
Radio equipment Yes/No Yes
Cold start air compressor (if electric) Yes/No
Emergency lighting on rigfloor Yes/No Yes
Emergency lighting around diesel engine plant Yes/No Yes
Emergency lighting (red light) on top of mast Yes/No Yes
Emergency lighting on other areas Yes/No Yes
Batteries chargers Yes/No No
Automatic start on standby generator Yes/No No
Abandonment system Yes/No Yes

Land Rig Equipment Specification Rev1 13 of 65


CONTRACTOR's Specification (fill in this column
ITEM only)
ITEM/DESCRIPTION PTTEPSA's Specification
NO. Preferred or Typical Specification shown where
relevant, but equivalent will be acceptable
Electric pump for BOP hydraulic controls (recharging pump for
Yes/No Yes
accumulator unit)
Fire & gas detection systems Yes/No Yes
C.1.6 Rig Service Air System
Air compressor (Electrical Driven)
Quantity 2
Make Specify Quincy
Model Specify QTD 45HH AC
Driven by motor power (HP) Specify 60 HP
Rated capacity (ft3 / min) Specify 257 ft3/min for each compressor
Working press (psi) Specify 120 psi
Air compressor (Diesel Driven)
Quantity Specify 1
Make Specify China
Model Specify Z142/10-G
Driven by motor power (HP) Specify 20 HP
Rated capacity (ft3 / min) Specify 50 ft3/min
Working press (psi) Specify 120 psi
Air Vessel
Quantity Specify 2+1
Capacity of each (Gal) Specify 650 Gal each
Certified by Specify Youxin Petroleum Mechanical Co. Ltd.
Location Specify Engine room+Beneath Rig floor
C.2 Rig Camp Power Plant
AC-power for the camp to be furnished by separate generators
Specify Denyo Genset 2 Ea
at the campsite
C.2.1 Diesel Engine & AC Generator Plant
Quantity Specify 2
Make-quantity Specify 2 x Denyo Model DCA-400 SPK-II,
Type Specify Komatsu Eng Model:SA6D140A, 415 HP
Maximum continuous power Specify 415 HP
Output volts Specify AC generator Model:DF-4400K, 350/400KVA

Land Rig Equipment Specification Rev1 14 of 65


CONTRACTOR's Specification (fill in this column
ITEM only)
ITEM/DESCRIPTION PTTEPSA's Specification
NO. Preferred or Typical Specification shown where
relevant, but equivalent will be acceptable
C.2.2 Transformers
Quantity Specify
Make Specify
Type Specify
Maximum continuous power Specify
Output volts Specify
Frequency Specify
D. Drill String Handling Tools
D.1 Tubulars
D.1.1 Kellies
a) Nominal Size OD 5-1/4" (As backup) 5-1/4"
Quantity 4 1
Shape type (hexagonal or square or triangular) HEX HEX
Total/working length min. 40', preferred 46' 40'
Connection 6 5/8" REG LH 6 5/8" REG LH
Equipped with kelly spinner (for both right / left rotation)
API classification API 7
D.1.1.1 Kelly Saver Subs for 5-1/4"
Nominal Kelly c/w csg protector
Quantity 2
Connection 4-1/2" IF
API classification API 7
D.1.1.2 Kelly Saver Subs for 4-1/2"
Nominal Kelly c/w csg protector
Quantity 2
Connection 3-1/2" IF
API classification API 7
D.1.1.3 Lower Kelly Valve Req.
Number 2 2
Make/type TIW Ball type
Dimensions (OD in x ID in) 6 3/4" x 3 6-5/8" x 2-13/16"
Top connection NC50 4-1/2" IF
Bottom Connection NC50 4-1/2" IF

Land Rig Equipment Specification Rev1 15 of 65


CONTRACTOR's Specification (fill in this column
ITEM only)
ITEM/DESCRIPTION PTTEPSA's Specification
NO. Preferred or Typical Specification shown where
relevant, but equivalent will be acceptable
Working pressure (psi) min. 5000 10,000 psi
D.1.1.4 Upper Kelly Valve Req.
Number 2 2
Make/type
Dimensions (OD in x ID in) To mate with swivel bottom thread
Top connection 6-5/8" Reg LH
Bottom Connection 6 5/8" REG LH 6-5/8" Reg LH
Working pressure (psi) min. 5000 10,000 psi
D.1.2 Drill Pipe
D.1.2a 5" OD Drill Pipe
all premium 50% of S135, 50%
Grade S-135
of G105
Total length 4,500 m 5000 m
Range R-2 R-2
Nominal Weight 19.5 ppf 19.5
Internally plastic coated Yes
Tool joint OD 6-5/8"
Tool joint ID 2-3/4"
Tool joint pin length 12"
Tapered shoulder tool joints Yes
Type of connections 4 1/2" IF (NC 50) NC 50
Type of hardfacing Req./Smooth Arnco100XT hard banding
Actual API classifications (prior to commencement date) TH-Hill-DS-1 cat level 5 Yes
Date of last inspection Aug-13
D.1.2b 3-1/2" od Drill Pipe
Grade all premium 3000 m of S135 S-135
Total length 3,000 m 3000 m
Range R-2 R-2
Weight 13.3 ppf 15.5 ppf
Internally plastic coated TC2000 Internal Plastic Coating
Tool joint OD 5”
Tool joint ID 2-1/8"

Land Rig Equipment Specification Rev1 16 of 65


CONTRACTOR's Specification (fill in this column
ITEM only)
ITEM/DESCRIPTION PTTEPSA's Specification
NO. Preferred or Typical Specification shown where
relevant, but equivalent will be acceptable
Tool joint pin length 10.5"
Tapered shoulder tool joints Yes
Type of connections 3 1/2" IF NC 38 NC 38
Type of hardfacing Req./Smooth Arnco100XT hard banding
Actual API classifications TH-Hill-DS-1 cat level 5 Yes
Date of last inspection New
D.1.2c 5" OD Drill Pipe Pup Joints
Quantity 2x5', 2x10', 2x15', 2x20' 3x5', 3x10', 3x15'
Grade S135 premium class S-135
Total length
Range R-2 R-2
Weight 19.5 ppf 19.5
Internally plastic coated Yes
Tool joint OD 6-5/8"
Tool joint ID 2-3/4"
Tool joint pin length 12"
Tapered shoulder tool joints Yes
Type of connections NC 50
Type of hardfacing Req./Smooth Arnco100XT hard banding
Actual API classifications TH-Hill-DS-1 cat level 5 Yes
Date of last inspection Aug-13
D.1.2d 3-1/2" OD Drill Pipe Pup Joints
Quantity 2x5', 2x10', 2x15', 2x20' N/A
Grade S135 premium class
Total length
Range R-2
Weight 13.3 ppf
Internally plastic coated
Tool joint OD
Tool joint ID
Tool joint pin length
Tapered shoulder tool joints
Type of connections

Land Rig Equipment Specification Rev1 17 of 65


CONTRACTOR's Specification (fill in this column
ITEM only)
ITEM/DESCRIPTION PTTEPSA's Specification
NO. Preferred or Typical Specification shown where
relevant, but equivalent will be acceptable
Type of hardfacing Req./Smooth
Actual API classifications TH-Hill-DS-1 cat level 5
Date of last inspection
D.1.3 Drill Collars (c/w lifting subs) Yes
D.1.3a.1 Drill Collars 14"
Quantity N/A
OD body
ID body
Length of each joint
Drill collar body (slick/spiral)
W/recess for "zip" elevator
W/recess for slips
W/stress relief pin groove
W/boreback on box
Type of connections
D.1.3a.2 Drill Collars 11 1/4"
Quantity N/A
OD body
ID body
Length of each joint
Drill collar body (slick/spiral)
W/recess for slips
W/stress relief pin groove
W/boreback on box
Type of connections
D.1.3a.3 Drill Collars 9 1/2"
Quantity full joint 6 joints 9 Jts
Quantity short joint (Pony) 2 x 10', 1 x 20' 3 x 10'
OD body 9"1/2 9-1/2"
ID body min 3" 3"
Length of each joint R-2 R-2
Drill collar body (slick/spiral) Spiral grooved Req. Spiral
W/recess for slips Yes

Land Rig Equipment Specification Rev1 18 of 65


CONTRACTOR's Specification (fill in this column
ITEM only)
ITEM/DESCRIPTION PTTEPSA's Specification
NO. Preferred or Typical Specification shown where
relevant, but equivalent will be acceptable
W/stress relief pin groove Req. Yes
W/boreback on box Yes
Type of connections 7"5/8 REG 7"5/8 REG
D.1.3a.4 Drill Collars 8"
Quantity full joint min 12 joints 24 Jts
Quantity short joint (Pony) 2 x 10', 2x 15', 1 x 20' 3 x 10'
OD body 8" 8"
ID body min 2-13"/16 2-13/16"
Length of each joint R-2 R-2
Drill collar body (slick/spiral) Spiral grooved Req. Spiral
W/recess for slips Yes
W/stress relief pin groove Req. Yes
W/boreback on box Yes
Type of connections 6"5/8 REG 6"5/8 REG
D.1.3a.5 Drill Collars 6"1/2
Quantity full joint min 15 joints 30 Jts
Quantity short joint (Pony) 2 x 10',
10' 2 x 15',
15' 1 x 20' 3 x 10'
OD body 6"1/2 6-1/2"
ID body 2"13/16 2-13/16"
Length of each joint R-2 R-2
Drill collar body (slick/spiral) Spiral grooved Req. Spiral
W/recess for slips Yes
W/stress relief pin groove Req. Yes
W/boreback on box Yes
Type of connections 4"1//2 IF (NC50) NC50
D.1.3a.6 Drill Collars 4 3/4"
Quantity full joint min 15 joints 30 Jts
Quantity short joint (Pony) 1 x 10', 1 x 20' 3 x 10'
OD body 4"3/4 4-3/4"
ID body min 2" 2"
Length of each joint R-2 R-2
Drill collar body (slick/spiral) Spiral grooved Req. Spiral
W/recess for slips Yes

Land Rig Equipment Specification Rev1 19 of 65


CONTRACTOR's Specification (fill in this column
ITEM only)
ITEM/DESCRIPTION PTTEPSA's Specification
NO. Preferred or Typical Specification shown where
relevant, but equivalent will be acceptable
W/stress relief pin groove Req. Yes
W/boreback on box Yes
Type of connections 3"1/2 IF (NC38) NC38
D.1.3b Non-Magnetic Drill Collars Nil
D.1.3c Subs and X-Over
Necessary Subs and X-Overs for all Contractor's Drill String lot (especially for 7 5/8" and 8 5/8"
Elements incl. Fishing conn.)
D.1.3d 5" Top Drive Saver Subs (Same as above)
Supply of Saver Sub to cross over from Contractor's Top Drive
lot for duration of contract 2 Ea
to quoted 5" Drillpipe
D.1.3e 3 1/2" Top Drive Saver Subs (Same as above)
Supply of Saver Sub to cross over from Contractor's Top Drive
lot for duration of contract 2 ea
to quoted 3 1/2" Drillpipe
D.1.3f Bit Subs
Number of 7 5/8" REG Box x 8 5/8" REG Box 2 each Nil
Number of 7 5/8" REG Box x 7 5/8" REG Box 2 each Yes
Number of 7 5/8" REG Box x 6 5/8" REG Box 2 each Yes
Number of 6 5/8" REG Box x 6 5/8" REG Box 2 each Yes
Number of 4 1/2" REG Box x 4 1/2" IF Box 2 each Yes
Number of 3 1/2" REG Box x 3 1/2" IF Box 2 each Yes
D.1.3g Bit Breakers For Tricone bit
Quantity 1 each
For bit sizes 26", 17"'1/2, 12"1/4, 8"1/2, 6-1/8"
D.1.3h Bit Caliper Ring
Quantity 1 each 1 each
For bit sizes 26", 17"'1/2, 12"1/4, 8"1/2, 6-1/8" 26", 17"'1/2, 12"1/4, 8"1/2, 6-1/8"
D.1.3i Drill Pipe Protectors for 5" Drill Pipe
Make/type Yes
Number All
D.1.3j Drill Pipe Protectors for 3 1/2" Drill Pipe
Make/type Yes

Land Rig Equipment Specification Rev1 20 of 65


CONTRACTOR's Specification (fill in this column
ITEM only)
ITEM/DESCRIPTION PTTEPSA's Specification
NO. Preferred or Typical Specification shown where
relevant, but equivalent will be acceptable
Number All
D.1.3k Drillpipe Drift (with wireline fishable head)
Size For 5" DP (19.5#), 3"1/2 DP (13.3#) Nil
Number 2 each
D.1.3l Drillpipe wipers
Size For all drillpipe sizes 5" & 3-1/2"
Number 2 each 10 Ea
D.1.4 Hevi-Wate Drill Pipe
Quantity 50jts, 50 jts 30 Jt / 30 Jt
Nominal size OD 5" , 3"1/2 5" , 3-1/2"
Weight 50.3 ppf, 25.65 ppf 50 ppf, 23.3 ppf
Range R-2 R-2
Tool Joint OD 6-5/8"
Tool Joint ID
Type of hardfacing
Internally plastic coated
Connection NC50, NC38 NC50, NC38
D.1.5 Shock Absorbers (damping sub) N/A Nil
D.1.6 Drilling Jars N/A Nil
D.1.7 Inside BOP Valves (Gray Safety valves)
Quantity 1 each 2 Each
Make Tianhe Oil Group Co., Ltd
Size 5" , 3"1/2 5" , 3"1/2
Min.Drill pipe ID required
Connections (type) NC50, NC38 NC50, NC38
Connections(OD) 5" / 3-1/2"
Working pressure rating 10,000 psi
D.1.8.a Float Valves (Non ported)
Quantity 2 each 2 each
Make Baker or Equivalent Baker
Type Non-ported Non-ported
For OD drill collar 9"1/2, 8", 6"1/2, 4"3/4 9"1/2, 8", 6"1/2, 4-3/4"

Land Rig Equipment Specification Rev1 21 of 65


CONTRACTOR's Specification (fill in this column
ITEM only)
ITEM/DESCRIPTION PTTEPSA's Specification
NO. Preferred or Typical Specification shown where
relevant, but equivalent will be acceptable
Floatsubs Bit subs Bit subs
Quantity
Size
Connection (box-box) 7"5/8 Reg, 6"5/8 Reg, 4"1/2 Reg 7"5/8 Reg, 6"5/8 Reg, 4"1/2 Reg
D.1.8.b Float Valves (ported)
Quantity 2 each 1 each
Make
Type
For OD drill collar 9"1/2, 8", 6"1/2, 4"3/4
Floatsubs
Quantity
Size
Connection (box-box) 7"5/8 Reg, 6"5/8 Reg, 4"1/2 Reg
D.1.9 Regan Fast Shut-off Coupling
Quantity
Size tool joint to fit
Drill pipe size
D.1.10 Circulation Subs for 5" and 3"1/2 DP
Quantity 2 each 1 Ea
Make
Type
OD body 5", 3"1/2
Top connection 2" FIG1502
D.1.11 Circulation Head for 20" csg.
Quantity 1 N/A
Make
Top connection 2" FIG1502
Bottom connection 20" BTC pin
Working pressure
D.1.12 Circulation Head for 18 5/8" csg. N/A
Quantity N/A
Make
Top connection

Land Rig Equipment Specification Rev1 22 of 65


CONTRACTOR's Specification (fill in this column
ITEM only)
ITEM/DESCRIPTION PTTEPSA's Specification
NO. Preferred or Typical Specification shown where
relevant, but equivalent will be acceptable
Bottom connection
Working pressure
D.1.13 Circulation Head for 16" csg. N/A
Quantity N/A
Make
Top connection
Bottom connection
Working pressure
D.1.14 Circulation Head for 13 3/8" csg. N/A
Quantity 1
Make
Top connection 2" FIG1502
Bottom connection 13-3/8" BTC pin
Working pressure
D.1.15 Circulation Head for 9 5/8" csg. N/A
Quantity 1
Make
Top connection 2" FIG1502
Bottom connection 9-5/8" BTC pin
Working pressure
D.1.16 Circulation Head for 7" csg. N/A
Quantity 1
Make
Top connection 2" FIG1502
Bottom connection 78" BTC pin
Working pressure
D.1.17 Drop-In Valves for 5" DP N/A
quantity
For nom. OD drillpipe
Make
Type
Completed with landing sub and retrieving tool
Max. Od of dart.

Land Rig Equipment Specification Rev1 23 of 65


CONTRACTOR's Specification (fill in this column
ITEM only)
ITEM/DESCRIPTION PTTEPSA's Specification
NO. Preferred or Typical Specification shown where
relevant, but equivalent will be acceptable
D.1.18 Drop-In Valves for 3"1/2 DP N/A
quantity
For nom. OD drillpipe
Make
Type
Completed with landing sub and retrieving tool
Max. Od of dart.
D.1.19 Cross-Over Subs
Enough cross-over subs to make up all possible drill and fishing
Req, specify Yes for Asia Drilling string.
string configurations.
The cross-overs will be include following :
- short X-over from drill collar connections to inside blow-out
Specify
preventers (0.3 m):
- at least three X-overs from all drill collar connections to drill
Specify
pipe connections:
Bit subs of at least 0.7 m length for fishing operations and as
Specify
p y
receptacle for float valve for the 8" drill collar sizes;
- X-over subs from 5" and 3-1/2" drill pipe Specify
D.1.20 Drilling Bumper Subs N/A N/A
D.1.21 Hole Openers N/A N/A
D.1.22 Under Reamer N/A N/A
D.1.23 Cement Kelly N/A N/A
D.1.24 Cementing Tubing
D.2 Handling Tools
Drill Pipe Elevators (center latch elevators for 18 deg
D.2.1a Req
tapered tool joints)
Quantity 2 each 2 each
Make Varco GG or eqvl. AOT
Model AOT31070GG / AOT31069GG
Size 5", 3"1/2 5", 3-1/2"
Rated capacity 350 tons/ 250 tons - centre latch 350 tons
D.2.1b1 Drill Collars Elevators
Quantity 2, 2 2

Land Rig Equipment Specification Rev1 24 of 65


CONTRACTOR's Specification (fill in this column
ITEM only)
ITEM/DESCRIPTION PTTEPSA's Specification
NO. Preferred or Typical Specification shown where
relevant, but equivalent will be acceptable
Make Varco TA Rodong Tongyong General Mechiney
Model DD9-1/2 & DD8
Size 9"1/2, 8" 9-1/2", 8"
Rated capacity min. 250 klbs
D.2.1b2 Drill Collars Elevators
Quantity 2, 2 1 each
Make Varco TA
Model
Size 6"1/2, 4"3/4 9-1/2"/ 8" / 6"1/2, 4"3/4
Rated capacity min. 250 klbs
D.2.1c Tubing Elevators N/A
Quantity
Make
Model
Size
Rated capacity
Extra inserts
D2.2 Drillpipe Manual (Hands) Slips
Quantity 2, 2, 2 2 Each
Make Varco TA or equivalent Jiangsu Saifu Petrol Machinery
Model SDXL 5” / 3-1/2"
Size 5", 3"1/2 5", 3-1/2"
Type
D2.2a Hydraulic Drillpipe Tongs/Iron Roughneck Req.
Make/type Specify ST-80C
Date of Manufacture or Last Overhaul 1990 or later 2010
RAIL/WIRELINE/OTHER mounted RAIL OR OTHER preferred
Capable of Handling 5" DP (Yes/No) Yes/No Yes
Capable of Handling 3 1/2" DP (Yes/No) Yes/No Yes
Capable of Handling 5" HWDP (Yes/No) Yes/No Yes
Capable of Handling 3 1/2" HWDP (Yes/No) Yes/No Yes
Capable of Handling 9"1/2 DC (Yes/No) Yes/No No
Capable of Handling 8" DC (Yes/No) Yes/No Yes

Land Rig Equipment Specification Rev1 25 of 65


CONTRACTOR's Specification (fill in this column
ITEM only)
ITEM/DESCRIPTION PTTEPSA's Specification
NO. Preferred or Typical Specification shown where
relevant, but equivalent will be acceptable
Capable of Handling 6"3/4 DC (Yes/No) Yes/No Yes
Capable of Handling 4"3/4 DC (Yes/No) Yes/No Yes
D.2.2b Semi-Automatic Drill Pipe Slips
Quantity N/A
Make
Model
Size
Type
D.2.2b1 Drillpipe Power Slips
Number 1
Make/type PS 375 / Varco type
Inserts for 5" and 3 1/2" Drillpipe Yes
Power Source (HYDR/AIR) Air
Maximum Load Capacity (klbs) 500 ton
D.2.2c.1 Drill Collars Slips
Quantity
Make
Model
Size
Type
D.2.2c.2 Drill Collar Slips
Quantity 2 each 2 Ea
Make Varco or eqvl. Varco type
Size 9 1/2, 8" 9 1/2, 8"
Type DCS-L DCS-L
D.2.2c3 Drill Collar Slips
Quantity 2 each 2 Ea
Make Varco or eqvl. Varco type
Size 6"1/2, 4"3/4 6"1/2, 4"3/4
Type DCS-L/DCS-R DCS-L/DCS-R
D.2.2d Drill Collar Safety Clamps
Quantity 3 3
Make Varco MP or equivalent Varco Type

Land Rig Equipment Specification Rev1 26 of 65


CONTRACTOR's Specification (fill in this column
ITEM only)
ITEM/DESCRIPTION PTTEPSA's Specification
NO. Preferred or Typical Specification shown where
relevant, but equivalent will be acceptable
Range For all DC Dimensions Yes
D2.2e Tubing slips
Quantity N/A
Make
Size
Type
D.2.2f Tubing Spider Elevator
Quantity N/A
Make
Adaptor plate
slip size
D.2.3a DC Lifting Subs
Quantity 3, 4 3, 4
For OD DC 9"1/2, 8" 9-1/2", 8"
Connection 7"5/8 REG, 6"5/8 REG 7"5/8 REG, 6"5/8 REG
D.2.3b DC Lifting Subs
Quantity 6 8
6, 6 8
6,
For OD DC 6"3/4, 4"3/4 6-1/2, 4-3/4"
Connection NC50, NC38 NC50, NC38
D.2.3b DC lifting eyes
Quantity 3 each 3 each
For OD DC 9"1/2, 8", 6"1/2, 4"3/4 9-1/2", 8", 6-1/2", 4-3/4"
Connection For all DC Dimensions For all DC Dimensions
D.2.4 Elevator Links Req.
Quantity of sets 1 2
Make
Type
Size 3-3/4" & 4-3/4"
Length 132" 9‟ 11” & 14' 10"
Rated capacity 1000 klbs
D.2.5 Kelly Spinner
Quantity of sets N/A
Make

Land Rig Equipment Specification Rev1 27 of 65


CONTRACTOR's Specification (fill in this column
ITEM only)
ITEM/DESCRIPTION PTTEPSA's Specification
NO. Preferred or Typical Specification shown where
relevant, but equivalent will be acceptable
Type
D.2.6 Drill Pipe Spinner Req./ HYDR preferred N/A
Quantity 1
Make Varco or eqvl.
Type
Size 5" and 3 1/2" of DP and HWDP
D.2.7 Mud Saver Bucket Specify for 5" & 3 1/2" DP
Quantity 1 Each
Make Octeco
Size 5" & 3-1/2"
c/w hose to trip tank Yes
D.2.8 Hydraulic Cathead (Ezy Torque) Specify 2 unit
Make Deyang Tianfa
Type YM-16
Maximum line pull 160kN
D.2.9 Rotary Rig Tongs Req
Manual tongs primarily designed for use with drillpipe
D.2.9.a
up to 5" and capable of handling 6-5/8" reg. Conn.
Quantity 1 set 1 Set
Make Varco or eqvl. Jiangsu Rodong
Type DB
Range size lug jaws 3-1/2” – 11 ¼”
Manual extra heavy tongs with a torque rating of
D.2.9.b N/A
100,000 ft lbs
Quantity 1 set
Make Varco-BJ SDD or eqvl.
Type
Range size lug jaws (up to 9"1/2 DC)
Manual tongs primarily designed for use with 3-1/2"
D.2.9.c
DP, 3-1/2" TBG and 2-7/8" TBG
Quantity 1 set 1 Set
Make Varco or eqvl. Jiangsu Rodong

Land Rig Equipment Specification Rev1 28 of 65


CONTRACTOR's Specification (fill in this column
ITEM only)
ITEM/DESCRIPTION PTTEPSA's Specification
NO. Preferred or Typical Specification shown where
relevant, but equivalent will be acceptable
Type B
Range size by jaws 3-3/8” – 12-3/4”
D.2.9.d Casing Manual Tongs : jaw must fit up to 20" casing
Quantity 1 Set
Make Varco or eqvl. Jiangsu Rodong
Type Casig Tong
Range size by jaws 13-3/8”~20”
D.3 Fishing Equipment Req. to fish own tubulars
D.3.1 Overshots
Overshots for all of the contractor's downhole equipment. Req. / Specify Please kindly see in separate sheets
a. Pack offs
b. Spiral and basket grapples
c. Extension subs (1.20 m long)
d. Oversized and regular lipped guides for the various hole
sizes
Quantity
Make/Type BOWEN ( USA )
Overshot Od
Overshot accessories
To catch size
To catch size
To catch size
To catch size
To catch size
To catch size
To catch size
Oversize guide for hole
Extension length
Top sub connection
Additional accessories to catch Associated
Services Contractor's mud motor
D.3.2 Fishing Jar (c/w repair kits) Req N/A
a. Hydraulic Fishing Jar

Land Rig Equipment Specification Rev1 29 of 65


CONTRACTOR's Specification (fill in this column
ITEM only)
ITEM/DESCRIPTION PTTEPSA's Specification
NO. Preferred or Typical Specification shown where
relevant, but equivalent will be acceptable
Quantity
Make
Size
Connection
Min. ID
D.3.3 Fishing Bumper Subs Req N/A
Quantity
Make
Size
OD body
Connection
Stroke
Min. ID
D.3.4 Safety Joints Req N/A
Quantity
Make
Model P/N
OD body
Min OD
Connection
D.3.5 Junk Baskets (reverse circulation) Req
Quantity
Make Model
For hole size 17"1/2, 12", 8"3/8, 5"7/8
OD body
Connection
Inside magnet available
Mill shoes type
D.3.6 Junk Subs Req
Quantity Yes
Make
Model P/N
For hole size

Land Rig Equipment Specification Rev1 30 of 65


CONTRACTOR's Specification (fill in this column
ITEM only)
ITEM/DESCRIPTION PTTEPSA's Specification
NO. Preferred or Typical Specification shown where
relevant, but equivalent will be acceptable
OD body
Connections
D.3.7 Flat Bottom Junk Mill Req
Quantity N/A
Make
Model
OD flat mill
Connection
D.3.8 Magnet Fishing Tools Req / Specify Size N/A
D.3.9 Taper Taps
Quantity Yes
Make Model
Minimum OD
lMaximum OD
Part No.
Connection
OD body
D.3.10 Packer Milling /Retrieval Tools
Quantity
Make
Model OD
Type
To Mill/fish packer
Extension plus catch/release plus mill
D.3.11 Tubing Spears N/A
Quantity
Make
OD
Size range
Connection
As required to join all fishing tools to
D.4 Cross Over / Subs Yes
drillstring

Land Rig Equipment Specification Rev1 31 of 65


CONTRACTOR's Specification (fill in this column
ITEM only)
ITEM/DESCRIPTION PTTEPSA's Specification
NO. Preferred or Typical Specification shown where
relevant, but equivalent will be acceptable

E. Well Control Equipment


E.1.1 29"1/2" 2M Diverter Assembly
Make and Type : Rongsheng /FFZ75-3.5
Bore size (in) 29-1/2"
Working pressure (psi) 500 psi
Top Flange (type and size) 29 ½” Studded & Flange ( R95 )
Bottom Flange (type and size) 29 ½”
Height (in) 68"
Side outlet Lines (Amount x ID x Length x WP) 6" 500 psi R45 Weldneck Flange
Side outlet Valves (Amount x ID x WP) 6" Class 300 Ball Valve
H2S Trim (Yes/No) Yes
21 1/4" 2M (or 20"3/4 3M) Annular with H2S trim to
E.1.2 For 1 Horizontal Well
meet NACE MR-01-75
Manuf/type Hydril GK 21 1/4 2000 or eqvl Rongsheng / FHZ54-14
Date of Manuf or last overhaul 5/9/2010
Number 1 5000 psi
p
Bore size (in) 21 1/4" 21-1/4"
Working pressure (psi) 2000 21-1/4", 5000psi
Top Flange (type and size) N/A 21-1/4", 5000psi
Bottom Flange (type and size) 21 1/4 -3M API 6BX 21 1/4 -5M API 6BX
Height (in) 57"
Oil Volume required to fully close (US gal) 241 liter ( 63.6 Gal )
H2S Trim (Yes/No) Yes Yes
21 1/4" 2M (or 20"3/4 3M) Single RAM with H2S trim
E.1.3 21-1/4" Double Ram BOP
to meet NACE MR-01-75
Manuf/type Cameron Single "U" or equivalent Rongsheng / 2FZ54-14
Date of Manuf or last overhaul 1995 or later 2011-01
Number 2 1
Bore size (in) 21 1/4" 21 1/4"
Working pressure (psi) 3000 5,000
Top Flange (type and size) 21 1/4 - 3M API 6BX 21 1/4 - 5M API 6BX
Bottom Flange (type and size) 21 1/4 - 3M API 6BX 21 1/4 - 5M API 6BX
Height (in) 46"

Land Rig Equipment Specification Rev1 32 of 65


CONTRACTOR's Specification (fill in this column
ITEM only)
ITEM/DESCRIPTION PTTEPSA's Specification
NO. Preferred or Typical Specification shown where
relevant, but equivalent will be acceptable
Side outlet (Yes/No, number and dimemsions) Yes
Oil Volume required to fully close (US gal) 63 liter ( 16.6 Gal )
Hand wheels to operate/lock BOP (Yes/No) Req. Yes
H2S Trim (Yes/No) Yes Yes
Comment : Side Outlets required between cavities, optional
below lower cavity
21 1/4"2M (or 20"3/4 3M) RAM Accessories with H2S
E.1.4
trim to meet NACE MR-01-75
Number of 5" DP RAM Sets 2 (1 installed, 1 spare) Yes
Number of 13"3/8 casing rams set 2 (1 installed, 1 spare) Yes
Number of 3 1/2" DP RAM Sets Yes
Number of 9 5/8" Casing RAM Sets Yes
Number of 7" Casing RAM Sets Yes
Number of 5 1/2" Casing RAM Sets Yes
Number of 5" Casing RAM Sets Yes
Number of 4 1/2" Casing RAM Sets Yes
Number of 3 1/2" Tubing RAM Sets Yes
Number of 2 7/8" Tubing RAM Sets Yes
Number of 3"1/2 - 7" Variable bore 2 (1 installed + 1 backup) Yes
Number of Blind RAM sets 2 (1 installed, 1 spare) Yes
Number of Shear RAM sets
21 1/4" 2M (or 20"3/4 3M) Drilling Spool (or mud
E.1.5 Req.
cross) with H2S trim to meet NACE MR-01-75
Number 1 1
Bore size (in) 21 1/4" 21 1/4"
Working pressure (psi) 2000 5000
Top Flange (type and size) 21 1/4 - 2M API 6BX 21 1/4 - 5M API 6BX
Bottom Flange (type and size) 21 1/4 - 2M API 6BX 21 1/4 - 5M API 6BX
Height (in)
Yes,2, min. 3 1/8" kill and 4 1/16"
Side outlet (Yes/No, number and dimensions) Yes / 4-1/16"
choke
H2S Trim (Yes/No) Yes Yes

Land Rig Equipment Specification Rev1 33 of 65


CONTRACTOR's Specification (fill in this column
ITEM only)
ITEM/DESCRIPTION PTTEPSA's Specification
NO. Preferred or Typical Specification shown where
relevant, but equivalent will be acceptable
13 5/8" 5M Annular with H2S trim to meet NACE MR-
E.1.6 Req.
01-75
Manuf/type Hydril GK 13 5/8 5000 or eqvl Shaffer Type
Date of Manuf or last overhaul 2010-06
Number 1 1
Bore size (in) 13 5/8 13 5/8
Working pressure (psi) 5000 5000
Top Flange (type and size) N/A 13-5/8" 5,000psi
Bottom Flange (type and size) 13 5/8" - 5M API 6BX 13-5/8" 10,000psi
Height (in) 48"
Oil Volume required to fully close (US gal) 94 liters ( 24.8 gal )
H2S Trim (Yes/No) Yes Yes
13 5/8" 5M Double RAM with H2S trim to meet NACE
E.1.7 13 5/8" 10M Double RAM with H2S trim
MR-01-75
Manuf/type Cameron Double "U" or equivalent Rongshang / 2FZ35-70 ( Shaffer Type )
Date of Manuf or last overhaul 2011-05
2011 05
Number 1 1
Bore size (in) 13 5/8" 13 5/8"
Working pressure (psi) 5000 10000
Top Flange (type and size) 13 5/8" - 5M API 6BX 13 5/8" - 10M API 6BX
Bottom Flange (type and size) 13 5/8" - 5M API 6BX 13 5/8" - 10M API 6BX
Height (in)
Yes,2, min. 3 1/8" kill and 4 1/16"
Side outlet (Yes/No, number and dimensions) Yes, 2, 4 1/16"
choke
Oil Volume required to fully close (US gal) 33 Liter ( 8.7 Gal )
Hand wheels to operate/lock BOP (Yes/No) Yes
H2S Trim (Yes/No) Yes Yes
Comment : Side Outlets required between cavities, optional
below lower cavity
13 5/8" 5M Single RAM with H2S trim to meet NACE
E.1.8 13 5/8" 10M Single RAM with H2S trim
MR-01-75
Manuf/type Cameron Single "U" or equivalent Shaffer Type

Land Rig Equipment Specification Rev1 34 of 65


CONTRACTOR's Specification (fill in this column
ITEM only)
ITEM/DESCRIPTION PTTEPSA's Specification
NO. Preferred or Typical Specification shown where
relevant, but equivalent will be acceptable
Date of Manuf or last overhaul
Number 1 1
Bore size (in) 13 5/8" 13 5/8"
Working pressure (psi) 5000 10,000
Top Flange (type and size) 13 5/8" - 5M API 6BX 13 5/8" - 10M API 6BX
Bottom Flange (type and size) 13 5/8" - 5M API 6BX 13 5/8" - 10M API 6BX
Height (in) 36"
Side outlet (Yes/No, number and dimensions) No
Oil Volume required to fully close (US gal) 33 Liter ( 8.7 Gal )
Hand wheels to operate/lock BOP (Yes/No) Yes
H2S Trim (Yes/No) Yes Yes
13 5/8" RAM Accessories with H2S trim to meet NACE
E.1.9
MR-01-75
Number of 5" DP RAM Sets 3 (2 installed, 1 spare) Yes
Number of 3 1/2" DP RAM Sets 2 (1 installed + 1 backup) Yes
Number of 9 5/8" Casing RAM Sets 2 (1 installed + 1 backup) Yes
Number of 7" Casing RAM Sets 2 (1 installed + 1 backup) Yes
Number of 5 1/2" Casing RAM Sets Yes
Number of 5" Casing RAM Sets Yes
Number of 4 1/2" Casing RAM Sets 2 (1 installed + 1 backup) Yes
Number of 3 1/2" Tubing RAM Sets 2 (1 installed + 1 backup) Yes
Number of 2 7/8" Tubing RAM Sets 2 (1 installed + 1 backup) Yes
Number of 3"1/2 - 7" Varible bore 2 (1 installed + 1 backup) Yes
Number of Blind RAM sets Yes
Number of Shear RAM sets 2 (1 installed + 1 backup) Yes
13 5/8" 5M Drilling Spool (or mud cross) with H2S trim 13 5/8" 10M Drilling Spool (or mud cross) with
E.1.10
to meet NACE MR-01-75 H2S trim to meet NACE MR-01-75
Number 2 1
Bore size (in) 13 5/8" 13 5/8"
Working pressure (psi) 5000 10,000
Top Flange (type and size) 13 5/8" - 5M API 6BX 13 5/8" - 10M API 6BX
Bottom Flange (type and size) 13 5/8" - 5M API 6BX 13 5/8" - 10M API 6BX
Height (in) 25"

Land Rig Equipment Specification Rev1 35 of 65


CONTRACTOR's Specification (fill in this column
ITEM only)
ITEM/DESCRIPTION PTTEPSA's Specification
NO. Preferred or Typical Specification shown where
relevant, but equivalent will be acceptable
Yes,2, min. 3 1/8" kill and 4 1/16"
Side outlet (Yes/No, number and dimemsions) Yes, 2, 4-1/16"
choke
H2S Trim (Yes/No) Req Yes
E1.11 11" BOP Optional for Workover Job Not Required
Blow- out preventer system in accordance to API
11" 5M Annular with H2S trim to meet NACE MR-
E.1.11.a 11" 5M Annular with H2S trim to meet NACE MR-01-75
01-75
Manuf/type Hydril GK
Date of Manuf or last overhaul 2009
Number 1
Bore size (in) 11"
Working pressure (psi) 5000 psi
Top Flange (type and size) 11" 5M
Bottom Flange (type and size) 11" 5M
Height (in)
Oil Volume required to fully close (US gal)
H2S Trim (Yes/No)
11" 5M Double RAM with H2S trim to meet NACE MR- 11" 5M Double RAM with H2S trim to meet
E.1.11.b
01-75 NACE MR-01-75
Manuf/type WSI (Diamond)
Date of Manuf or last overhaul 2007
Number 1
Bore size (in) 11"
Working pressure (psi) 5000 psi
Top Flange (type and size) 11" 5M
Bottom Flange (type and size) 11" 5M
Height (in)
Side outlet (Yes/No, number and dimemsions) 4-1/16"
Oil Volume required to fully close (US gal)
Hand wheels to operate/lock BOP (Yes/No) Yes
H2S Trim (Yes/No) Yes
Comment : Side Outlets required between cavities, optional
below lower cavity

Land Rig Equipment Specification Rev1 36 of 65


CONTRACTOR's Specification (fill in this column
ITEM only)
ITEM/DESCRIPTION PTTEPSA's Specification
NO. Preferred or Typical Specification shown where
relevant, but equivalent will be acceptable
11" 5M Single RAM with H2S trim to meet NACE MR-01- 11" 5M Single RAM with H2S trim to meet NACE
E.1.11.c
75 MR-01-75
Manuf/type Cameron / type U
Date of Manuf or last overhaul 2007
Number 1
Bore size (in) 11"
Working pressure (psi) 5000 psi
Top Flange (type and size) 11" 5M
Bottom Flange (type and size) 11" 5M
Height (in)
Side outlet (Yes/No, number and dimemsions) 4-1/16"
Oil Volume required to fully close (US gal)
Hand wheels to operate/lock BOP (Yes/No) Yes
H2S Trim (Yes/No) Yes
E1.11.d Pipe Rams Accessoires with H2S trim to meet NACE MR-
01-75
Standard shear rams Yes
Blind rams Yes
5" rams 4-1/2"
3-1/2" rams 3-1/2"
Variable rams No
9-5/8" rams No
7" rams Yes
Risers (or spacer) with H2S trim to meet NACE MR-01-
E.1.12
75
Contractor required to provide adapters and spacer spools to
connect with Company's wellhead. Spooling and bell nipple to
accommodate variations in wellhead elevations.
- Riser 21"1/4 x 21"1/4 , 3M spacer spool 21"1/4 x 21"1/4 , 5M spacer spool
- Riser 13"5/8 x 13"5/8, 5 M spacer spool or 10M if 13-5/8 10K
13"5/8 x 13"5/8, 10 M spacer spool
BOP is provided

Land Rig Equipment Specification Rev1 37 of 65


CONTRACTOR's Specification (fill in this column
ITEM only)
ITEM/DESCRIPTION PTTEPSA's Specification
NO. Preferred or Typical Specification shown where
relevant, but equivalent will be acceptable
Adapters (Between wellhead and BOP) with H2S trim to
E.1.13
meet NACE MR-01-75
Contractor required to provide adapters and spacer spools to
connect with Company's wellhead. Spooling and bell nipple to
accommodate variations in wellhead elevations.
- 21"1/4 3K x 20"3/4 3K No
- 11" 5K x 13"5/8 5K or 10K (if 13-5/8" 10K BOP is provided) No

- 11" 10K x 13"5/8 5K or 10K (if 13-5/8" 10K BOP is provided) No

- 13-5/8" 5K x 13"5/8 10K (if 13-5/8" 10K BOP is provided) No

- 11" 5K x 11" 10K (for work over if 11" 10K BOP is provided) No
E.1.14 Hydraulic Wrench for BOP Bolts
Number 2 1 (Back up Hammer wrenches)
Sufficient for all BOP Bolt Sizes in Enerpac Hydraulic Torque Wrenchs W2000P and
Make/Model
Stacks W4000P
Capacity 2000 to 4000 ft lbs
Choke line & valves 5K with H2S trim to meet NACE MR-
E.1.15 Req 10 K choke Assembly
01-75
3” ID x 5ksi WP
1 manual gate valve / manuf / type
1 hydr gate valve w/manual override/ manuf / type
Must have flanged connections (no threaded)
Kill line & valves 5K with H2S trim to meet NACE MR-01-
E.1.16 Req
75
3” ID x 5M psi WP 2" ID x 10 M psi
1 manual gate valve / manuf / type Yes
1 hydr gate valve w/manual override/ manuf / type YEs
Must have flanged connections (no threaded) Yes
Check valve req to protect mud pumps / stand-pipe

Land Rig Equipment Specification Rev1 38 of 65


CONTRACTOR's Specification (fill in this column
ITEM only)
ITEM/DESCRIPTION PTTEPSA's Specification
NO. Preferred or Typical Specification shown where
relevant, but equivalent will be acceptable
Hydraulic Actuated Choke Valve (HCR) 5K with H2S
E1.17 Req
trim to meet NACE MR-01-75
Make/type Chengde kingdream
ID 4-1/16"
WP 10,000 psi
Choke & kill hoses 5K with H2S trim to meet NACE MR-
E.1.18 Req.– hoses to meet API Spec 16C
01-75
Coflexip/Technip and Taurus/Phoenix hoses which comply with
API 16 C are acceptable
Manuf / type Specify Flange Type
3” ID 5ksi WP 4-1/16" ( 10,000 psi )
# of hoses min 3 req 3
Flanged connections only
E1.19 Bop Stack Handling System Req.
Lifting system Air/hyd./elect. operated Hydraulic
Type lifting device (hydraulic/mechanical) Neuhaus or eqvl. Hydraulic
Rated capacity 2 x 25 ton SWL 2 x 30 Ton SWL
General Remarks
1. All necessary adapter spools to connect contractor BOP
equipment to Company furnished wellhead equipment. List Req. As per rig attached
spools and X-overs.
2. Flow risers for use with BOP's and for the 20" or
Req. As per rig attached
30"stovepipe (bell nipple, etc.)
3. Transportation skids for the BOPs, incl. set back Req. As per rig attached
c/w p-test port and 4 1/2" IF conn. to enable BOP As per rig attached
pressure test off line. As per rig attached
5. All ram preventers except shear bonnet to be equipped with
Req. Yes
hand wheels and extensions.
E.2 BOP CONTROL SYSTEM
E.2.1 BOP Control Equipment Req

Land Rig Equipment Specification Rev1 39 of 65


CONTRACTOR's Specification (fill in this column
ITEM only)
ITEM/DESCRIPTION PTTEPSA's Specification
NO. Preferred or Typical Specification shown where
relevant, but equivalent will be acceptable
BOP closing system must have an accumulator unit of sufficient
capacity to provide 1.5 times the usable fluid volume required
to close all 4 rams and the annular preventer, open the Yes/No Yes
hydraulic gate valve, and retain a min operating pressure of
1,200 psi on
Manuf / type Specify Huabei Rongsheng / FKQ960-8
To comply with API RP 16E. Specify Yes
Air powered pump: output pressure Specify
Electric powered pump: output pressure Specify
Accumulator bottles: number / size / cap / WP Specify 24btl / 40 L / 3000 psi
Hydraulic fluid reservoir capacity Specify 1600 Liter
Location of master control panel Specify tool pusher office
Location of remote control panel Specify rig floor
Must be capable of closing each ram in 30 sec and annular in
Yes/No Yes
30 sec (nom 20” annular in 45 sec)
Accumulator lines to be hard piped or stainless steel armoured
Yes/No
/ Yes
conforming w/ API 16D
Isolation valves must be installed on annular control lines to
Yes/No Yes
allow testing of lines to 3ksi
E.2.2 Choke manifold with H2S trim to meet NACE MR-01-75
Schemaitic & Drawing Req
Manual adj choke: manuf / model min 2 req 1
Hydraulic adj choke w/controls adj to driller: manuf / model min 1 req 2
Valves upstream of choke: manuf / # / size / WP 4-1/16"
Valves downstream of choke: manuf / # / size / WP 4-1/16"
Upstream line size / WP
Downstream line
Buffer chamber
Built as per API specification
Piping to vertical (poor boy) degasser
Annulus & standpipe pressure gages.

Land Rig Equipment Specification Rev1 40 of 65


CONTRACTOR's Specification (fill in this column
ITEM only)
ITEM/DESCRIPTION PTTEPSA's Specification
NO. Preferred or Typical Specification shown where
relevant, but equivalent will be acceptable
Outlet to Mud / Gas Separator with H2S trim to meet
E.2.3
NACE MR-01-75
Quantity
Valve Size :
Working pressure (psi) 5,000 psi
Outlet to flare line with H2S trim to meet NACE MR-01-
E.2.4
75
Quantity
Valve Size :
Working pressure (psi) 5,000 psi
E.2.5 Flare line (From poor boy Degasser to flare pit) Provided to waste pit
Length (m) 20m
ID / OD : 8" / 8-5/8"
Working pressure (psi) 1,160 psi
Mud / gas separator (poor boy) with H2S trim to meet
E.2.6 Req.
NACE MR-01-75
Provide schematic drawing
Separator vessel height min 16ft 16 ft
Separator vessel dia min 36” 48"
Mud/gas inlet dia min 4” 4"
Mud outlet dia min 6” 10"
Gas outlet dia min 8” 10"
U-tube height min 6ft 10ft
Separator working pres min 3psi 100 psi
All flanges ANSI 150 min ANSI 150
Vessel to have target in place at mud/gas inlet
Internal baffle arrangement Yes
Liquid returns to possum belly
Gas vent line discharge up side of derrick No / Direct line to Pit
Gas vent line equiv length max 250 ft straight-up 150 Ft straight
E.2.7 BOP test tools, Cup type testers
Cup for casing sizes with 100% spare
- 20" - Casing weight : 133ppf Req Yes

Land Rig Equipment Specification Rev1 41 of 65


CONTRACTOR's Specification (fill in this column
ITEM only)
ITEM/DESCRIPTION PTTEPSA's Specification
NO. Preferred or Typical Specification shown where
relevant, but equivalent will be acceptable
- 13"3/8 - Casing weight : 68ppf Req Yes
- 9"5/8 - Casing weight : 47ppf Req Yes
- 7" - Casing weight : 29ppf Req Yes
E.2.8 Plug Type Testers N/A N/A
Quantity
Make
Size test plugs
Connection Quantity
E.2.9 Portable BOP test pump & test stumps Req.
Manuf of test pump CAD, USA
Low vol / high pres 10ksi WP min 1 req 20,000 psi
Test stump for 21”1/4, 5ksi WP BOP min 1 req.
Test stump for 13-5/8”, 10ksi WP BOP
E.2.10 BOP handling equipment Req.
Manuf / type – describe BOP hoisting system. Yes
“Safe” system req. Answer Y/N.
Optional:
System must be capable of lifting Company specified 20” and
13-5/8” BOP arrangement f/test stump to riser as a complete
unit
Hydraulic Powerd torque wrench for BOP connection
E.2.11 Req. Yes
make up
Quantity : 1 Set
Make / Type : ENERPAC / Hydraulic Type
Completed with torque indicator : Yes
E.2.12 Bell nipple To be provide by Company
Telescopic with 5 feet min stroke and seal system
- For Diverter (Diameter / Length / Type) Req
- For 21"1/4 BOP (Diameter / Length / Type) Req
- For 13"5/8 BOP (Diameter / Length / Type) Req
- For 11" BOP (Diameter / Length / Type) Optional for workover
E.2.13 Chiksan Joints
Number 8 8

Land Rig Equipment Specification Rev1 42 of 65


CONTRACTOR's Specification (fill in this column
ITEM only)
ITEM/DESCRIPTION PTTEPSA's Specification
NO. Preferred or Typical Specification shown where
relevant, but equivalent will be acceptable
Nominal Size (in) 2 2
Working pressure (psi) 5000 5000
Length of each joint (ft) min. 6 min. 6
H2S Trim (Yes/No)
Connections type 1502 type 1502
E.2.14 BOP set back support skid for rig move required

F. MUD SYSTEM
F.1 High Pressure Mud
F1.1 Mud pumps (prefer 3 units)
Mud pumps to be operated up to 90% of manufacturer’s
Yes/No Yes
operating pressure rating.
Manuf / type / model Specify HHF 1600
Number min. 2 x 1600 HP 3 units
Drive / input 1600 HP 1600 HP
Liner sizes required: 7"
7 -55" (Please specify) Yes
Pressure Rating 5000 psi (4,500 continous) 5000 psi ( 4500 contineous )
Systhetic (Oil) Base mud compatible ? Yes/No Yes
Fluid end replacement parts (Southwest or equiv) Specify Mud King, USA
F1.2 Mud pump related equipment Req
Suction Line ID 12"
Pulsation dampeners Yes
Pressure relief valve (pop-offs) type/pres rtg OTECO / Type RR
Isolation valve type/pres rtg
Precharge pump number/size/HP 3 Charge pump with 75KW SB6 ×8F J-12-½
Systhetic (Oil) Base mud compatible ? Yes
Mud manifold (attach schematic)
F1.3 High pressure lines
Discharge lines (ID / WP) 5,000 psi 5,000 psi
Rotary hose (ID / WP) 5,000 psi 5,000 psi
Spare hose in derrick (ID / WP) 5,000 psi 5,000 psi
Systhetic (Oil) Base mud compatible ? Yes/No Yes
Safety snub lines (per API RP54) – Y/N? Yes

Land Rig Equipment Specification Rev1 43 of 65


CONTRACTOR's Specification (fill in this column
ITEM only)
ITEM/DESCRIPTION PTTEPSA's Specification
NO. Preferred or Typical Specification shown where
relevant, but equivalent will be acceptable
F1.4 Standpipe manifold (Preferably 4")
Working Pressure for manifold & valves 5,000 psi 5,000 psi
Valve Size : Specify 5"
Standpipe quantity / ID min. 2 2
Cement discharge lines at drill floor (independent of standpipe
Separate 3" hard line runs from hopper area to rig floor
manifold).
Arrangement for reverse circulation Yes
Drill pipe bleed off line with valve. Yes
Connected to choke man. thru appropriate valves. Can be connected with Chiksans when required
Means to connect standpipe to cement lines. Can be connected with Chiksans when required
Facility to connect chiksans. Yes
Drawings Req Attached
F1.5 Low torque valves & redress kits Req
Draw a line diagram of the mud system showing tanks, mixing
facilities and the various treating systems. Tanks-tanks-pump
Yes
co ec o s to
connections o be o
of a
an adjus ab e qu
adjustable quick
c co
connect
ec type,
ype, NOT
O
flange x flange. All rubber parts and seals to be OBM resistant.
F2. LOW PRESSURE MUD SYSTEM Req Yes
Capable of circulating between any two pits.
Attach current pit layout, piping diagrams and flow diagram
must be as complete as practical
F2.1 Active and reserve pits completed with agitator Req Yes
Total # of active / reserve pits Specify
Shale shaker tank: 1 - 351 BBL
Suction tank : 1 - 396 BBL
Mixing tank: 1 - 318 BBL
Total volume of active / reserve pits 1,000 bbls / 1,000 bbls Reserve tank: 3 - 1,287 BBL
Mud Branching Tank: 1 - 220 BBL
Trip Tank: 1 - 100 BBL
Total Volume: 2,672 BBL
F2.2 Mud tanks (additional reserve)

Land Rig Equipment Specification Rev1 44 of 65


CONTRACTOR's Specification (fill in this column
ITEM only)
ITEM/DESCRIPTION PTTEPSA's Specification
NO. Preferred or Typical Specification shown where
relevant, but equivalent will be acceptable
All valves in pits to seal against water to prevent brines
f/mixing w/other fluids.
Each tank equipped with a mud mixer given a turnover time of
45-75 sec. The active tank to be dimensioned such that a
volume change of 1 cu m is indicated by a level change of at
least 10 cm. Tanks to be sectionalised for in series treatment
by solids rem
F2.3 Solid control tanks Req
Shale shaker tank: 1 - 351 BBL
Suction tank : 1 - 396 BBL
All valves in pits to seal against water to prevent brines mixing Mixing tank: 1 - 318 BBL
with other fluids. Solids control tank volumes NOT to be incl in Reserve tank: 3 - 1,287 BBL
1600 bbl req. Mud Branching Tank: 1 - 220 BBL
Trip Tank: 1 - 100 BBL
Total Volume: 2,672 BBL
Sand trap capacity, bbls Specify
Desander tank capacity
capacity, bbls Specify
Desilter tank capacity, bbls Specify
Desilter return tank capacity, bbls Specify
Other tanks capacity, bbls Specify
F2.4 Mud agitators (Min 2 / pit) 1 per pit 1 per pit
All active, reserve & slug pits to have agitator(s).
Manufac / HP Specify KF87B-19-AD5-V11-090811K / 15 KW (20HP)
Is the tank covered for use with Synthetic (oil) base mud ? Yes
Do all active/reserve/slug pits have agitators – Y/N Yes
F2.5 Mud guns (Min 2 / pit) min 1 per pit
Do all pits have mud guns – Y/N?
F2.6 Trip Tank
Capacity 2 x 25 bbls 2 x 50 bbls
Capacity/meter in / meter
Level indicator Yes
Electric pump make Yes

Land Rig Equipment Specification Rev1 45 of 65


CONTRACTOR's Specification (fill in this column
ITEM only)
ITEM/DESCRIPTION PTTEPSA's Specification
NO. Preferred or Typical Specification shown where
relevant, but equivalent will be acceptable
Model/type SB3” x 4” J-9 1/2"
Motor output 11 kW
Alarm and strip chart recorder N/A
Facility for \casing fill-up Yes
F2.7 Stripping Tank N/A
Capacity Optional
Capacity/meter
Equalising facility with triptank
Transfer pump
F2.8 Mixing hoppers (4")
Hoppers must be manifolded together such that both may be
ZHP150
used on 1 pit OR on 2 separate pits at the same time.
Manuf / type Chengdu West Petroleum / ZHP150
Quantity Min 2 3 units
Hoppers c/w Venturi 75kW
mixing rate 1480rpm
F2.9 Polymer shearing device/ homogenizer Req
Manuf / type Chengdu West Petroleum
Min mixing rate, bpm 791 GPM
F2.10 Centrifugal pumps for mixing mud
Manuf / type WJQ5” ×6” -10”
Quantity Min 2 1
Motor speed / HP 100 HP 55 kW
Impeller sizes 10”
F2.11 Shale shakers
Independently driven shale shakers capable of handling 4,5 cu
FLO-LINE CLEANER-503-3p
m/min of 50/60 seconds March Funnel viscosity mud through
Derrick / USA
API mesh 60 screens.
Manuf / type / yrs in service
Quantity Min. 3 of linear motion shakers 3 units
Driven by electric motors - number 3 Motors

Land Rig Equipment Specification Rev1 46 of 65


CONTRACTOR's Specification (fill in this column
ITEM only)
ITEM/DESCRIPTION PTTEPSA's Specification
NO. Preferred or Typical Specification shown where
relevant, but equivalent will be acceptable
Shaker cover (roof) Yes Yes
Max. Flowrate Yes
Screen sizes 50 mesh through 210 mesh required Yes
F2.12 Desanders Required Attached with Mud Cleaner together
Unit performance will be verified by Company. Substandard
equip perfor will be corrected by Contractor prior to rig being
accepted by Company.
Manuf / type / yrs in service
Number of cones x sizes min. 3x10" 2 x 10"
Type/size centrifugal pump feed pump required SB6” × 8” F J-13”
Operating pressure range (feed pump to meet req) 30~40 psi
Feed pump sized to operate unit at max rate, 1750 RPM min 75 HP 75 KW
F2.13 Desilter min. 1 FLC -503
Quantity 1
Make
Number of cones x sizes min.
min 20 x4" 10" x 2 & 4" x 16
Type/size centrifugal pump feed pump required SB6” × 8” F J-13”
Driven by electric motor-power rating 75 Kw
Max. flowrate 240m3/h
F2.14 Centrifuge (optional) Optional
Number 2 1
make/type Derrick or eqvl. Chengdu West Petroleum / LW355×1257-N
Hi-speed, Variable speed Hi Speed
Capacity < 36m3/h
Able to set up for barite recovery mode ? Yes/No No
Suction/return line to active & mixing
Set-up for active & reserve tanks Yes
tanks
F2.15 Mud degasser Required
Piping to be in compliance with the IADC Mud System
Arrangement - Mud Equipment manual and as described in the
appendices.
Manuf / type Derrick, USA / Vacu-Flo 1200

Land Rig Equipment Specification Rev1 47 of 65


CONTRACTOR's Specification (fill in this column
ITEM only)
ITEM/DESCRIPTION PTTEPSA's Specification
NO. Preferred or Typical Specification shown where
relevant, but equivalent will be acceptable
Type/size centrifugal pump Centrif. 5x6
Processing rate 40CAMB-COHT 75 C RISE
Feed pump sized to operate unit at max rate SB6” × 8” F J-13”
Attach details of gas vent/discharge line
Piping in compliance w/IADC Mud System Yes
F2.16 Mud / Gas Separator (poor boy) Required
Quantity 1
make/type Honghua
Gas discharge line OD 10"
Gas discharge line routed to shakers 10"
Mud gas separator to be at least in
accordance with API. Yes
F2.17 Cellar Pumps
Quantity 2 2
Make P8 Wilden Pumps
Flowrate (liters/minute) 1500 liters/min 700 liters/min for each pump
Type Air Operated
F2.18 Base Oil Wash Gun
C/W 15 m hosees, connections and handle to use at shakers
Yes Yes
during SBM operation
F2.19 Mud Saver Box
Required with range of inserts for supplied drill string, with
Yes
drain hose.
Make & Type :
Size Range :
F2.20 One set for mud return line Req Yes
F2.21 Mud testing area Req On the Active tank
Test area with sink, fresh water, compressed air, electricity
240/110 VAC, 2 mud balances, 2 marsh funnels, 2 stop Yes
watches, etc.
At Company’s discretion, fluids service company to provide lab
c/w equip. Contractor to install & provide electricity &
plumbing for same.

Land Rig Equipment Specification Rev1 48 of 65


CONTRACTOR's Specification (fill in this column
ITEM only)
ITEM/DESCRIPTION PTTEPSA's Specification
NO. Preferred or Typical Specification shown where
relevant, but equivalent will be acceptable

F2.22 Camera to monitor returns at +10ft level and at shakers Min. 1 1 for Monkey Board
Manuf / type 1 for Mud pump and Tank
With vertical & horizontal panning controls located at driller’s
1 for Casing Standing board
console.
Must be movable from +10’ level to shaker area. 1 for Cellar
Must be approved for use in appropriate hazardous zoning area
1 for Shaker
in which it is installed.
G. Casing / Cementing
G1 Casing Equipment Provided by Company's Tubular Running Services
G1.1 API Casing Drifts Req Provided by Company's Tubular Running Services
For 20" OD/casing weight
For 13-3/8" OD/casing weight
For 11 3/4" OD/casing weight
For 9-5/8" OD/casing weight
For 7"
7 OD/casing weight
For 5" OD/casing weight
For 4-1/2" Liner
For 3-1/2" Tubing
For 2-7/8" tubing
G1.2 Clamp-On Type Casing protectors Provided by Company's Tubular Running Services
For 13-3/8" OD casing
For 9-5/8" OD casing
For 7" OD casing
For 4-1/2" OD liner
Side Door Casing Elevator ---> Provide by tubular
G1.3 Req Provided by Company's Tubular Running Services
running
Quantity
For OD casing
make
Type
Capacity

Land Rig Equipment Specification Rev1 49 of 65


CONTRACTOR's Specification (fill in this column
ITEM only)
ITEM/DESCRIPTION PTTEPSA's Specification
NO. Preferred or Typical Specification shown where
relevant, but equivalent will be acceptable

G1.4 Single Joint Elevators---> Provide by tubular running Req Provided by Company's Tubular Running Services
Quantity
For OD casing / tubing
make
Type
C/W safety latches and 3/4" wire rope
Slip Type Elevator / Spiders ---> Provide by tubular
G1.5 Req Provided by Company's Tubular Running Services
running
Quantity
Make
Type
Capacity
W/slips for OD casing
G1.6 Casing Slips---> Provide by tubular running Req Provided by Company's Tubular Running Services
Quantity 2 each
Make
Type
20", 13"3/8, 9"5/8, 7", 4"1/2, 3"1/2,
For OD casing
2"7/8
G1.7 Casing Bowls Req
Quantity
Make
Type
20", 13"3/8, 9"5/8, 7", 4"1/2, 3"1/2,
For OD casing
2"7/8
G1.8 Casing Manual Tongs Req Provided by Company's Tubular Running Services
Quantity
Make
Type
20", 13"3/8, 9"5/8, 7", 4"1/2, 3"1/2,
W/jaws range for OD casing
2"7/8

Land Rig Equipment Specification Rev1 50 of 65


CONTRACTOR's Specification (fill in this column
ITEM only)
ITEM/DESCRIPTION PTTEPSA's Specification
NO. Preferred or Typical Specification shown where
relevant, but equivalent will be acceptable

G1.9 Power Casing tongs---> Provide by tubular running Provided by Company's Tubular Running Services
Quantity
Make
Type
W/jaws range for OD casing
Torque indicator
Back-up arm
Power Tubing Tong (Jam Type Unit)---> Provide by
G1.10 Provided by Company's Tubular Running Services
tubular running
Quantity
Make
Type
W/jaws for OD tubing
Torque indicator
Back-up arm
Torque - turn analysis equipment has to be provided by a third
party service company
G1.11 Power Unit for Casing Tong and Tubing Tong Req. Provided by Company's Tubular Running Services
Quantity 1
Driven by electric motor or ex. Proof engine Req.
Make & type
Casing Circulating Head (swedge) --> Provide by PTTEP
G1.12 Req Provided by Company's Tubular Running Services
??
For OD casing
Type of connection
Top connection
G1.13 Casing Spears (internal) N/A
Quantity
Make
Type
For OD casing
For casing weight

Land Rig Equipment Specification Rev1 51 of 65


CONTRACTOR's Specification (fill in this column
ITEM only)
ITEM/DESCRIPTION PTTEPSA's Specification
NO. Preferred or Typical Specification shown where
relevant, but equivalent will be acceptable
With pack-off
G1.14 Casing Cutters (internal) N/A
Quantity
Make
Type
For OD casing
G1.15 Crossover to Handle Casing with Drillpipe N/A
Quantity
For OD casing
Casing connection
Drill pipe connection
Rated capacity
G1.16 Casing Scrapers Provided on rental from 3rd party when required
Quantity 1 each 1 each
Make Bowen or equivalent
Casing size 9"5/8, 7" 9-5/8", 7"
Casing weight (43.5-58.4#),
(43 5 58 4#) (29-41#)
(29 41#) 43 5 ppf - 58.4ppf,
43.5 58 4ppf 29 ppf - 41 ppf
OD body
Connection
G2 Cementing System
G2.1 Cementing Manifold Req
Cementing unit to be connected to a 15000 psi
cement/washdown/kill standpipe manifold on drillfloor with a
HP 3" ID hose. The system should be separate from regular N/A
s/pipe. The system shall be flexible enough to link the unit to
the rig's killing line.
ID / and Quantity
G2.2 Low pressure water supply line Yes
Water supply line to cement unit area Req
Diameter / psi / flowrate / end connection
G2.3 Low pressure mud supply line
Mud supply line to cement unit area Req Yes
Diameter / psi / flowrate / end connection

Land Rig Equipment Specification Rev1 52 of 65


CONTRACTOR's Specification (fill in this column
ITEM only)
ITEM/DESCRIPTION PTTEPSA's Specification
NO. Preferred or Typical Specification shown where
relevant, but equivalent will be acceptable
G2.4 Low pressure casing fill up line Req
Quantity Yes
Diameter / psi / flowrate
H. Instrumentation
H1 Drilling Instruments
H1.2 Instruments at Driller's Position
H1.2.a Weight Indicator (6-8-10-12 lines strung) Req Yes
Make M/D Totco (USA)
Type E type AWE-series
Sensor type Digital load cell ( NOV )
H1.2.b Standpipe Pressure Gauge Req
quantity 3
Make M/D Totco (USA)
Type Flange Type
Pressure range 10,000 psi
H1.2.c Choke Manifold Pressure Gauge g Req
q
Quantity 2
Make M/D Totco (USA)
Type
0-5,000psi and 0-2,000psi with
Pressure range 0~10,000 psi
Isolation valve
H1.2.d Rotary Speed Tachometer Req. f/Topdrive & RT
Quantity Yes
Make HH
Type
Capacity range
H1.2.e Rotary torque Indicator Req./TDS & RT Yes
Number HH
Make
Type
Pump Stroke Counters and spm Indicators Consisting of
H1.2.f one pump stroke indicator and one cumulative pump stroke Req.
counter for each pump

Land Rig Equipment Specification Rev1 53 of 65


CONTRACTOR's Specification (fill in this column
ITEM only)
ITEM/DESCRIPTION PTTEPSA's Specification
NO. Preferred or Typical Specification shown where
relevant, but equivalent will be acceptable
Quantity 3 3
Make M/D Totco (USA)
Type Digital
H1.2.g Tong Torque Indicator Req.
Quantity 1 1
Make M/D Totco (USA)
Typoe H6E-Series
Capacity range 100,000 lb
Pit Volume Totaliser Complete with floats in active mud
H1.2.h tanks and on reserve tank completed with loss gain indicator Req.
and alarm (audio and visual).
Quantity 12
Make Siemens
Model SITRANS Probe LU
H1.2.i Mud Flow Indicator Req.
Quantity 1
Make Chongqing Petroleum Instrument
Model M/D Style Flow Line Sensor
High/low alarm (audio and visual) Yes
H1.2.j Trip Tank Indicator Electrical and direct visual
Quantity Yes
Make
Model
Chart recorder N/A
System-5704 (8 Channel)
H1.2.k General Alarm System Specify
Honeywell, USA
H1.2.l Remote Choke Control Unit Req. 2 Ea
Make to API spec. 1 on rig floor / 1 on toolspusher
H1.2.m Soft torque System
Make
H1.3 Instruments in Dog House
H1.3.a Drilling Parameter Recorder Req. for min. 24 hrs. rec. N/A
Quantity 1

Land Rig Equipment Specification Rev1 54 of 65


CONTRACTOR's Specification (fill in this column
ITEM only)
ITEM/DESCRIPTION PTTEPSA's Specification
NO. Preferred or Typical Specification shown where
relevant, but equivalent will be acceptable
Make Totco or eqvl. Electroinc System
Type DR6WPTRS Pump Pressure
Quantity of pens 6 Strng Weight
Parameter recorded String weight ROP
Parameter recorded ROP RPM
Parameter recorded RPM Torque
Parameter recorded Torque SPM
Parameter recorded Pump pressure
Parameter recorded Pump rate
H1.3.b Pit Volume Recorder Req. N/A
Quantity
Make
Type
H1.3.c Flowrate Recorder Req. N//A
Quantity
Make
Type
H1.3.d Triptank Recorder Req. N/A
Quantity
Make/type
H1.4 Instrumentation at choke Manifold
H1.4.a Standpipe Pressure Gauges Req.
Quantity 1 2
Make Octeco, USA
Type
Pressure rating 10,000 psi
H1.4.b Choke Manifold Pressure Gauge Req. 2
Quantity
Make Octeco, USA
Type
0-5,000psi and 0-2,000psi with
Pressure rating 10,000 psi
Isolation valve

Land Rig Equipment Specification Rev1 55 of 65


CONTRACTOR's Specification (fill in this column
ITEM only)
ITEM/DESCRIPTION PTTEPSA's Specification
NO. Preferred or Typical Specification shown where
relevant, but equivalent will be acceptable
Remarks:Combined on one panel and visible from choke
operating position.
H1.5 Instrumentation at Standpipe manifold
H1.5.a Standpipe Pressure Gauge Req.
Quantity 2
Make Oteco, USA
Type Flange Type
Pressure rating 10,000 psi
Remarks : To be visible from Driller's position Req. Yes
H1.5.b Mud Pump Pressue Gauge Req. 3
Quantity
Make Octeco, USA
Pressure rating 0-5000 psi 10,000 psi
H1.6 Deviation Equipment N/A
H1.6.a Measuring Device
Quantity 1 complete set.
Make Totco, with heat shield
Totco MD Totco
Deviation range 0 - 8 degree, 1-16 degrees 1-16 deg
Retrieving tool : Reg
Sinker weight Req.
H1.6.b Slickline/Wireline Unit for totco run (item H1.6.a) N/A
make/type
Drive Motor(s) (Number, Make and Type) Rental from Third party
Depth capacity (m) min. 4500
Reel capacity (m)
Pull indicator
New Reel at Contract Startup (Yes/No) Req.
H1.7 General Instruments Req.
Quantity
Ring gauges N/A
Tri-point calipers (e.g HOMCO) N/A
Internal/external calipers Yes
Derrick tapes Yes

Land Rig Equipment Specification Rev1 56 of 65


CONTRACTOR's Specification (fill in this column
ITEM only)
ITEM/DESCRIPTION PTTEPSA's Specification
NO. Preferred or Typical Specification shown where
relevant, but equivalent will be acceptable
H1.8 Calibrated Pressure Gauges Req. N/A
Make
Type instrument gauge
Size
Connection
Range
Quantity
Range
Quantity
Range
Quantity
Including facilities to install gauges on
standpipe manifold, choke manifold and
cement unit.
H2 Rig Communication System Yes
H2.1 Internal telephone system Req.
Should extend to the following area as a minimum rig floor Rig Floor
(explosion proof), Companyman's office & bed, mud lgger, Shaker Area
Req
mud engineer office, tool pusher office & bed, rig camp Mud pump area
(gallery). VFD unit
Shall be capable to provide paging system through out rig area. Req
No. of Stations 6 unit
Make/model Specify
Type instrument gauge
Explosion Proof
H2.2 Raido System
Type (antenna type) : 5 Ea
Quantity :
Oman license : (yes / no)
Explosion Proof
K ACCOMMODATION

Land Rig Equipment Specification Rev1 57 of 65


CONTRACTOR's Specification (fill in this column
ITEM only)
ITEM/DESCRIPTION PTTEPSA's Specification
NO. Preferred or Typical Specification shown where
relevant, but equivalent will be acceptable

K1 Rig Site Accomodation :


For COMPANY and 3rd Party (quantity / type of
K1.1 10 / Specify
unit)
Note : each room containing sigle beds, wash basins,
mirror, closet, desk, chair, 1/2 size refrigerator, with Req Yes
separate toilet, shower, hot water, AC
Remarks :
- Company representative's office : Complete with
desk, filing cabinets and funiture, complete with an
Req Yes
unrestricted view of the rig floor; one furnished bed-room
and shower toilet for Company representative's office.

- COMPANY Drilling Engineer's office : Complete


with desk, filing cabinets + furniture; one furnished Req Yes
bedroom and shower toilet for the Drilling Engineer.
- Mud Engineer office : with lab, bedroom and shower
Req N/A
toilet.
K1.2 For Rig Crew (quantity / type of unit) Specify
Remarks :
- Toolpusher Office : office complete with desk, filing
cabinets and funiture, complete with an unrestricted view of Req. Yes
the rig floor; and acomplete furnished bed-room
- For the drillers and Elec/mech : 2 offices with a toilet
Req. Yes
room
- For Medic/Clinic Room with shower and Radio room Req. 20'
- Rig site mess room Req. 40'
- General mess room Req. 40'
K2 Camp site Accommodation
K2.1 For COMPANY and 3rd Party (quantity) 26 / Specify 26

Land Rig Equipment Specification Rev1 58 of 65


CONTRACTOR's Specification (fill in this column
ITEM only)
ITEM/DESCRIPTION PTTEPSA's Specification
NO. Preferred or Typical Specification shown where
relevant, but equivalent will be acceptable

Remarks : Req
- 1 unit of 2 man cabins
- 6 units of 4 man cabins
K2.2 For Rig Crew (quantity) Specify
Remarks :
- Two kitchen/mess. (one f/rig site) Yes
- Two recreation/office Yes
- One cooler/freezer/dry storage Yes
- One office/laboratory/sleeper Yes
- One hospital/laundry Yes
- One toilet + 1 stand alone toilet for use during rig move Yes
- One toilet/bath Yes
Skid mounted, air conditioned of equivalent portable field
Yes
camp buildings, size 10 ft x 36 ft mounted on skids
All units shall be fully furnished 2 unit of Denyo ( 400 KVA )
Caterpillar generator set type 3408 DI TA or eqvl.
50 HZ 280 kkva prime power.
Caterpillar generator set type 3406 DI TA or eqvl.
50 HZ 225 kva prime power.
L SAFETY EQUIPMENT
L1 General Safety Equipment
- first Aid Box, 600 x 700 x 250 Req. Yes
- Two personnel strechers. Req. Yes
- One air operated alarm system. Req. Yes
- Safety hats + boots + gloves for all personnel on rig and for
Req. Yes
visitors (10 pieces).
- eye protection where required. Req. Yes
- Derrick man's escape system I.e. REM chute Req. YEs
L2 Safty Warning Sign Req.
must be located in appropiate area around the rig and camp.
All signs to be clearly written in Arabic and English languages

Land Rig Equipment Specification Rev1 59 of 65


CONTRACTOR's Specification (fill in this column
ITEM only)
ITEM/DESCRIPTION PTTEPSA's Specification
NO. Preferred or Typical Specification shown where
relevant, but equivalent will be acceptable
- No smoking notices Yes/No Yes
- No Vehicles beyond this point Yes/No Yes
- Pressure testing sign Yes/No Yes
- Wearing safety helmet is mandatory Yes/No Yes
- Vehicles must be diesel powered only Yes/No Yes
L3 Fixed Gas Detection Equipment Wellhead H2S,CH4
- Fix gas detection system at mud ditch , rigfloor, and over
Req
shale shakers. Shakers x2 H2S,CH4/ Rig floor H2S, CH4
- General alarm system readout and alert Req Yes
L4 Portable gas detectors Req.
Draeger gas detectors min. 2 req 2 unit
H2S, O2, CO and LEL meter min. 2 req 2 unit
L.5 H2S Monitoring System Req.
Mandatory 6 point monitor system with readout. Auxilary
readout. Auxilary read out in main Company office. Audible and
Yes
visual alarms to be located: Bell nipple, Rig Floor, Shale shaker,
Gas Trap area, Mud pits, 6th subject to define
Manuf / Type Honeywell, USA
Number & location System-5704 (8 Channel)
Power supplies
L.6 System For H2S Safety & Escape
Work area SCBA, 25 unit or as required 25 units 10 Unit
H2S detection/alarm system
Breathing air compressor, 2 req
Cascade system on the rig
Training of personnel
Breathing air bottles and manifold on boats
Lifeboat breathing air cascade system
L.7 Combustible Gas Monitoring System DETCON H2S and LEL monitoring
L.8 Fire Fighting Equipment Specify
At Rig Site :

Land Rig Equipment Specification Rev1 60 of 65


CONTRACTOR's Specification (fill in this column
ITEM only)
ITEM/DESCRIPTION PTTEPSA's Specification
NO. Preferred or Typical Specification shown where
relevant, but equivalent will be acceptable

- CO2 Type fire extinguishers (Type / capacity / quantity) CO2 - 5Kg x 4


Powder 50kg x 2
- Large Size Power Type fire extinguishers (Type / capacity /
40 Kg x 2
quantity)
43 kg x 1
4 Kg x 20
- Small Size Power Type fire extinguishers (Type / capacity /
5 Kg x 1
quantity)
2 kg x 13

- Fire Water Pump Diesel Engine (Quantity / flowrate / Only motor drive x 2 unit .
pressure) Engine type ( N/A )
- Two sets fire hoses with couplings placed around the rig as
per fire fighting plan No. 10046/2-0.
- Mobile foam generator or light water station. Foam - 6L x 15
- Personnel protection for fire fighting personnel. (ie. Helmet
with face shield / fire suits / fire proof blankets) (Quantity)
At Camp Site :
- CO2 Type fire extinguishers (Type / capacity / quantity) N/A
- Large Size Power Type fire extinguishers (Type / capacity /
40 Kg x 2
quantity)
- Small Size Power Type fire extinguishers (Type / capacity /
4 kg x 20
quantity)

- Fire Water Pump Diesel Engine (Quantity / flowrate /


On ordered
pressure)
- Two sets fire hoses with couplings placed around the rig as
Yes
per fire fighting plan No. 10046/2-0.
- Mobile foam generator or light water station. N/A
- Personnel protection for fire fighting personnel. (ie. Helmet
1 set
with face shield / fire suits / fire proof blankets) (Quantity)

Land Rig Equipment Specification Rev1 61 of 65


CONTRACTOR's Specification (fill in this column
ITEM only)
ITEM/DESCRIPTION PTTEPSA's Specification
NO. Preferred or Typical Specification shown where
relevant, but equivalent will be acceptable
L.9 Personnel Protective Equipment
L.10 Breathing apparatus Req.
SCBA of limited duration. Company's well encounter known
H2S. A comprehensive system for working in and escape from min. 4 Yes
H2S is req.
Number/type of escape BA units 5 Sets
L.11 First Aid box Req. Yes
L.12 First Aid Kits
Quantity 9 Ea
Located at Rig Floor , Medic room , TP Office
Rig floor, monkey board, shale
Eye Wash bottles to be situated at assigned positions shakers, mixing hopper, mud lab,
outside medic room
Deluge at mud mixing area.
M Miscellaneous Equipment
M1 Transport and lifting equipment
M1.1 Crew change 6 wheel truck or minibus, c/w seat belts Req Yes
M1.2 Trailer truck, 18 wheeler, c/w 40' flat bed trailer Req
M1.3 Rig skid pullers optional Nil
M1.4 Light transport Req
- Quantiy : min 2 1
- Type : 5 ton canter
M1.5 Lifting Equipment
Crane 1
40ton Req 40 ton
One forklift with 5 tons capacity, with 'dessert' type big tires Req 1 Forklift 5 ton
M2 Fuel Tanks
All tanks and lines are protected to allow continuous operation
Yes/No Yes
in harsh weather condition
Rig site :

Land Rig Equipment Specification Rev1 62 of 65


CONTRACTOR's Specification (fill in this column
ITEM only)
ITEM/DESCRIPTION PTTEPSA's Specification
NO. Preferred or Typical Specification shown where
relevant, but equivalent will be acceptable
- Estimated Fuel Consumption (m3/day) Specify 9 m3/day
- Diesel tanks and capacity (with pumping system c/w dip
Adequated for 30 days Operation 82 m3 (Adequate for 9 days)
pan/tanks installed)
Camp Site :
- Estimated Fuel Consumption (m3/day) Req 1 m3/day
- Diesel tanks and capacity (with pumping system c/w dip Adequated for 30 days Operation
20 m3
pan/tanks installed) (20 m3)
M3 Drill Water Tank / pumps
Drill water pit : privide by COMPANY, but the transfer pumps
Yes
and other facility by the CONTRACTOR
Rig Site :
- Pumps and hose for transferring. (Quantity / flowrate) 1, 250 gpm
- Estimated drill water Consumption (m3/day) Specify 20 m3/day
- Water tanks and capacity (with pumping and distribution
Adequated for 30 days Operation 3, Total 1,000 bbl (8 days operation)
system)
M4 Portable Water Tank / pumps
Camp Site :
- Pumps and hose for transferring. (Quantity / flowrate) 200 BBL
- Estimated water Consumption (m3/day) Specify
- Water tanks and capacity (with pumping and distribution Adequated for 30 days Operation
system, same as K1.9) (60 m3)
M5 Water Treating Unit
One berkefield filtration unit with chlorination system 700-1600
Req Yes
gal capacity/day
M6 Brine Filtration system. N/A
M7 Diatamatious Earth Unit N/A
M6 Spare Parts Stores Req. Yes
M7 Welding and Cutting Gear
Electric welding units, standard oxy/acelene, welding/cutting
Req. two set Yes
equipment.
M8 High Pressure Cleaning Unit Req. two units
High pressure wash gun c/w hose to reach all parts of the rig. Yes

Land Rig Equipment Specification Rev1 63 of 65


CONTRACTOR's Specification (fill in this column
ITEM only)
ITEM/DESCRIPTION PTTEPSA's Specification
NO. Preferred or Typical Specification shown where
relevant, but equivalent will be acceptable
M9 Flood Lights
Sufficient to light the drilling location at night; at least 4
Req. Yes
portable units complete with cabling.
M10 Hand Tools
As required Req.
M11 Bug Blowers
One brandt mode B-250 Req. Yes
M12 Ditch Magnet
Certified skids, skips and containers for CONTRACTOR DP,
M13 Req. Yes
tubular, subs,tools, equipment, etc.
Certified lubricant storage skid or tanks, c/w drip pan/tanks
M14 Yes
installed.
M15 Mousehole / rathole drilling equipment Yes
N. Rig Move Equipment
N1 Heavy Trucks for rig move with camp / without camp Specify Third party Services
Make / Type :
Description
Capacity :
Amount : 110 trucks for Rig / 35 trucks for Camp
N2 Light Trucks for rig move with camp / without camp Specify Third paty Service
Make / Type :
Description
Capacity :
Amount :
N3 Cranes for rig move with camp / without camp Specify
Make / Type : KATO
Description
Capacity : 55 ton
Amount : 2 unit (one unit rental from third party )
N4 Forklift for rig move with camp / without camp Specify
Make / Type : CAT - L 39

Land Rig Equipment Specification Rev1 64 of 65


CONTRACTOR's Specification (fill in this column
ITEM only)
ITEM/DESCRIPTION PTTEPSA's Specification
NO. Preferred or Typical Specification shown where
relevant, but equivalent will be acceptable
Description
Capacity : 10 ton
Amount : 1 unit
N5 Front Loader with camp / without camp Specify
Make / Type :
Description
Capacity :
Amount :
Estimated rig move duration (days) with camp /
N6 Specify With camp , without camp
without camp
Within 50 km. 18 Days 14 Days
Within 50-75 km.
Within 75-100 km. 21 Days 18 Days
Within over 100 km