Land Rig Equipment Specification Rev3
Land Rig Equipment Specification Rev3
Land Rig Equipment Specification Rev3
ITEM only)
ITEM/DESCRIPTION PTTEPSA's Specification
NO. Preferred or Typical Specification shown where
relevant, but equivalent will be acceptable
A Land Rig/Location/Classification/Drawing/Certification
A.1 Location & Availabillity of the drilling unit
Note: Include location of rig prior to tender "window" if
different than current location
Date rig is free from prior commitment Specify Subject to availability of the Rig
Current location Specify Udon Thani, Thailand
Current rig status (drilling-idle-etc.) Specify Drilling with setting up for UBD operations
If rig idle, since when Specify
Mobilization time to Location (Myanmar Block G, Location G-1) Months 45 Days started from confirm date
Current operating company and phone number Specify APICO (Khorat) Limited / +66 2659 5809
A.2 Drilling unit information
Name of drilling unit Specify AD-2
Type and class (Shall be diesel electric driven with SCR or DC-
Specify AC / VFD
DC system or AC-VFD or Hydraulics System)
Owner Specify Asia Drilling Pte Ltd
Designer/model (incl. design upgrade/variation) Specify NOV / HongHua
Yard/builder/date of construction Specify 2010
Modifications/Refurbishment made since built Specify Brand New
Date/reason/yard Specify
Date of last in yard Specify Feb-10
Provide plan & side view schematics of drilling unit, all decks Specify
(drawings are mandatory)
Rated depth min. 4000 m. with 5" DP 7000m
Maximum allowable pull min. 750,000 lbs 1,000,000.00 lb
A.3 Average fule consumption
At rig site, normal drilling condition (m3 / day) Specify 12.0 m3/day
At Camp site (m3 / day) Specify 0.55 m3/day
Top drive elevators links for running casing size / rate (klbs) Specify 3-1/2" x 3.35m, 1,000 klbs
Top drive wireline accessories kit Specify 2"
Air elevators - optional (list if rig is equipped) Yes/No
B.5.8 Automatic driller
Must be able to control ROP by: 1) pump pres differential or,
2) ROP. Unit will be used extensively and will be inspected Yes/No Yes
prior to rig acceptance to ensure compliance.
ROP controlled by both differential pressure and ROP limits –
Yes/No Yes
Y/N?
Manuf/type Specify NOV
Model/age Specify NOV
Describe system Specify NOV
C. Power Supply Systems
C.1 Riggppower p plant
Complete power system comprising of diesel driven generator
sets supplying DC and AC power (or alternatively using an SCR Specify AC / VFD
system)
C.1.1 Main Diesel Engines
Sufficient power for rig to be 100% functional with loss of one
unit, i.e. backream, pump, mix mud and run solid control Yes/No Yes
equipment
Manuf/type Cat 3512 or D399 or equivalent Cat 3512
Number of units 4 3
total output HP Specify 1749bhp
Can rig circulate and rotate with one engine down (show
Yes/No Yes
circulation)
Can rig POOH (with backreaming) with one engine down (show
Yes/No Yes
calculation)
Type of Fuel Diesel Diesel
At rotation speed of Equipped with spark arresters Yes/No Yes
Muffers installed Yes/No Yes
- 11" 5K x 11" 10K (for work over if 11" 10K BOP is provided) No
E.1.14 Hydraulic Wrench for BOP Bolts
Number 2 1 (Back up Hammer wrenches)
Sufficient for all BOP Bolt Sizes in Enerpac Hydraulic Torque Wrenchs W2000P and
Make/Model
Stacks W4000P
Capacity 2000 to 4000 ft lbs
Choke line & valves 5K with H2S trim to meet NACE MR-
E.1.15 Req 10 K choke Assembly
01-75
3” ID x 5ksi WP
1 manual gate valve / manuf / type
1 hydr gate valve w/manual override/ manuf / type
Must have flanged connections (no threaded)
Kill line & valves 5K with H2S trim to meet NACE MR-01-
E.1.16 Req
75
3” ID x 5M psi WP 2" ID x 10 M psi
1 manual gate valve / manuf / type Yes
1 hydr gate valve w/manual override/ manuf / type YEs
Must have flanged connections (no threaded) Yes
Check valve req to protect mud pumps / stand-pipe
F. MUD SYSTEM
F.1 High Pressure Mud
F1.1 Mud pumps (prefer 3 units)
Mud pumps to be operated up to 90% of manufacturer’s
Yes/No Yes
operating pressure rating.
Manuf / type / model Specify HHF 1600
Number min. 2 x 1600 HP 3 units
Drive / input 1600 HP 1600 HP
Liner sizes required: 7"
7 -55" (Please specify) Yes
Pressure Rating 5000 psi (4,500 continous) 5000 psi ( 4500 contineous )
Systhetic (Oil) Base mud compatible ? Yes/No Yes
Fluid end replacement parts (Southwest or equiv) Specify Mud King, USA
F1.2 Mud pump related equipment Req
Suction Line ID 12"
Pulsation dampeners Yes
Pressure relief valve (pop-offs) type/pres rtg OTECO / Type RR
Isolation valve type/pres rtg
Precharge pump number/size/HP 3 Charge pump with 75KW SB6 ×8F J-12-½
Systhetic (Oil) Base mud compatible ? Yes
Mud manifold (attach schematic)
F1.3 High pressure lines
Discharge lines (ID / WP) 5,000 psi 5,000 psi
Rotary hose (ID / WP) 5,000 psi 5,000 psi
Spare hose in derrick (ID / WP) 5,000 psi 5,000 psi
Systhetic (Oil) Base mud compatible ? Yes/No Yes
Safety snub lines (per API RP54) – Y/N? Yes
F2.22 Camera to monitor returns at +10ft level and at shakers Min. 1 1 for Monkey Board
Manuf / type 1 for Mud pump and Tank
With vertical & horizontal panning controls located at driller’s
1 for Casing Standing board
console.
Must be movable from +10’ level to shaker area. 1 for Cellar
Must be approved for use in appropriate hazardous zoning area
1 for Shaker
in which it is installed.
G. Casing / Cementing
G1 Casing Equipment Provided by Company's Tubular Running Services
G1.1 API Casing Drifts Req Provided by Company's Tubular Running Services
For 20" OD/casing weight
For 13-3/8" OD/casing weight
For 11 3/4" OD/casing weight
For 9-5/8" OD/casing weight
For 7"
7 OD/casing weight
For 5" OD/casing weight
For 4-1/2" Liner
For 3-1/2" Tubing
For 2-7/8" tubing
G1.2 Clamp-On Type Casing protectors Provided by Company's Tubular Running Services
For 13-3/8" OD casing
For 9-5/8" OD casing
For 7" OD casing
For 4-1/2" OD liner
Side Door Casing Elevator ---> Provide by tubular
G1.3 Req Provided by Company's Tubular Running Services
running
Quantity
For OD casing
make
Type
Capacity
G1.4 Single Joint Elevators---> Provide by tubular running Req Provided by Company's Tubular Running Services
Quantity
For OD casing / tubing
make
Type
C/W safety latches and 3/4" wire rope
Slip Type Elevator / Spiders ---> Provide by tubular
G1.5 Req Provided by Company's Tubular Running Services
running
Quantity
Make
Type
Capacity
W/slips for OD casing
G1.6 Casing Slips---> Provide by tubular running Req Provided by Company's Tubular Running Services
Quantity 2 each
Make
Type
20", 13"3/8, 9"5/8, 7", 4"1/2, 3"1/2,
For OD casing
2"7/8
G1.7 Casing Bowls Req
Quantity
Make
Type
20", 13"3/8, 9"5/8, 7", 4"1/2, 3"1/2,
For OD casing
2"7/8
G1.8 Casing Manual Tongs Req Provided by Company's Tubular Running Services
Quantity
Make
Type
20", 13"3/8, 9"5/8, 7", 4"1/2, 3"1/2,
W/jaws range for OD casing
2"7/8
G1.9 Power Casing tongs---> Provide by tubular running Provided by Company's Tubular Running Services
Quantity
Make
Type
W/jaws range for OD casing
Torque indicator
Back-up arm
Power Tubing Tong (Jam Type Unit)---> Provide by
G1.10 Provided by Company's Tubular Running Services
tubular running
Quantity
Make
Type
W/jaws for OD tubing
Torque indicator
Back-up arm
Torque - turn analysis equipment has to be provided by a third
party service company
G1.11 Power Unit for Casing Tong and Tubing Tong Req. Provided by Company's Tubular Running Services
Quantity 1
Driven by electric motor or ex. Proof engine Req.
Make & type
Casing Circulating Head (swedge) --> Provide by PTTEP
G1.12 Req Provided by Company's Tubular Running Services
??
For OD casing
Type of connection
Top connection
G1.13 Casing Spears (internal) N/A
Quantity
Make
Type
For OD casing
For casing weight
Remarks : Req
- 1 unit of 2 man cabins
- 6 units of 4 man cabins
K2.2 For Rig Crew (quantity) Specify
Remarks :
- Two kitchen/mess. (one f/rig site) Yes
- Two recreation/office Yes
- One cooler/freezer/dry storage Yes
- One office/laboratory/sleeper Yes
- One hospital/laundry Yes
- One toilet + 1 stand alone toilet for use during rig move Yes
- One toilet/bath Yes
Skid mounted, air conditioned of equivalent portable field
Yes
camp buildings, size 10 ft x 36 ft mounted on skids
All units shall be fully furnished 2 unit of Denyo ( 400 KVA )
Caterpillar generator set type 3408 DI TA or eqvl.
50 HZ 280 kkva prime power.
Caterpillar generator set type 3406 DI TA or eqvl.
50 HZ 225 kva prime power.
L SAFETY EQUIPMENT
L1 General Safety Equipment
- first Aid Box, 600 x 700 x 250 Req. Yes
- Two personnel strechers. Req. Yes
- One air operated alarm system. Req. Yes
- Safety hats + boots + gloves for all personnel on rig and for
Req. Yes
visitors (10 pieces).
- eye protection where required. Req. Yes
- Derrick man's escape system I.e. REM chute Req. YEs
L2 Safty Warning Sign Req.
must be located in appropiate area around the rig and camp.
All signs to be clearly written in Arabic and English languages
- Fire Water Pump Diesel Engine (Quantity / flowrate / Only motor drive x 2 unit .
pressure) Engine type ( N/A )
- Two sets fire hoses with couplings placed around the rig as
per fire fighting plan No. 10046/2-0.
- Mobile foam generator or light water station. Foam - 6L x 15
- Personnel protection for fire fighting personnel. (ie. Helmet
with face shield / fire suits / fire proof blankets) (Quantity)
At Camp Site :
- CO2 Type fire extinguishers (Type / capacity / quantity) N/A
- Large Size Power Type fire extinguishers (Type / capacity /
40 Kg x 2
quantity)
- Small Size Power Type fire extinguishers (Type / capacity /
4 kg x 20
quantity)