en - E2 Control Panel Technical Manual
en - E2 Control Panel Technical Manual
en - E2 Control Panel Technical Manual
Installation manual for control panel for automations with two 230 V~ motors
with built-in radio.
PRG ANT
SIG
JR1
AUX
COM
RF
BIXMR2
GOL4
B
ON
OFF 1 2 3 4 5 6
F1 A
ON
OFF 1 2 3 4
TR R1 TC TM IN
11
12
SA
L N UW V X Z Y 15 13 12 11 0 1 1 5 6 8 9 POWER
com
com
Flashing light
+
-
Output 24 V= / max 0,5 A
Electric lock
Lamp
M1 closing limit switch
M2 closing limit switch
Step-by-step
Safety stop
Safety re-opening
Stop
230V~ 230V~
Motor 1 Motor 2
Power supply
IP1935EN
Technical manual
www.entrematic.com
INDEX
Subject Page
1. *eneral safet\ precautions 3
2. EC declaration of conformit\ 4
3. Technical data 4
3.1 Applications 4
4. Connection of power suppl\ 4
5. Commands 5
6. Outputs and accessories 6
7. Adjustments 7
8. Radio receiver operation 9
9. Start-up 9
10. TroubleshootinJ 10
11. Example application for Jates with one swinJinJ door winJ 11
12. Example application for Jates with two swinJinJ door winJs 13
13. Hold-to-run function mode 15
IP1935EN 2010-07-19 2
1. GENERAL SAFETY PRECAUTIONS
This installation manual is intended for professionall\ competent personnel onl\.
The installation, the power connections and the settinJs must be completed in conformit\ with *ood
:orNinJ Methods and with the reJulations in force.
Before installinJ the product, carefull\ read the instructions. Bad installation could be ha]ardous. The pacNaJinJ
materials (plastic, pol\st\rene, etc.) should not be discarded in the environment or left within reach of children,
as these are a potential source of ha]ard.
Before beJinninJ the installation checN that the product is in perfect condition.
'o not install the product in explosive areas and atmospheres the presence of Àammable Jas or fumes re-
presents a serious threat to safet\.
The safet\ devices (photocells, sensitive edJes, emerJenc\ stop, etc.) must be installed taNinJ into account
the provisions and the directives in force, *ood :orNinJ Methods, the installation area, the functional loJic of
the s\stem and the forces developed b\ the automation.
Before maNinJ power connections, checN that the ratinJ corresponds to that of the mains suppl\. A mul-
tipolar disconnection switch with a contact openinJ Jap of at least 3 mm must be included in the mains
suppl\. ChecN that upstream of the electrical installation an adeTuate residual current circuit breaNer and an
overcurrent cut out are ¿tted.
:hen reTuested, connect the automation to an effective earthinJ s\stem carried out as indicated b\ current
safet\ reJulations.
'urinJ installation, maintenance and repair operations, cut off the power suppl\ before openinJ the cover to
access the electrical parts.
To handle electronic parts, wear earthed antistatic conductive bracelets. The manufacturer of the moto-
risation declines all responsibilit\ in the event of components which are not compatible with the safe and
correct operation of the product.
For repairs or replacements of products onl\ oriJinal spare parts must be used.
3 IP1935EN 2010-07-19
2. EC DECLARATION OF CONFORMITY
Manufacturer: DITEC S.p.A.
Address: via Mons. Ban¿, 3 21042 Caronno P.lla (VA) - ITALY
declares that the control panel E2 (with receiver 433.92 MH]) is in conformit\ with the provisions of the follow-
inJ EC directives:
R&TTE Directive 1999/5/CE;
EMC Directive 2004/108/CE;
Low VoltaJe Directive 2006/95/CE.
3. TECHNICAL DATA
E2 E2J
Power supply 230 V~ / 50 H] 120 V~ / 60 H]
F1 fuse F5A F6,3A
1 motor output 230 V~ / 5 A 120 V~ / 6,3 A
2 motors output 230 V~ / 2 x 2,5 A 120 V~ / 2 x 3,15 A
Accessories power supply 24 V= / 0,5 A
Temperature -20 °C / +55 °C
Degree of protection IP55
Memorizable radio codes 200
Radio frequency 433,92 MH]
i NOTE: the given operating and performance features can only be guaranteed with the use of DITEC
accessories and safety devices.
3.1 Applications
IP1935EN 2010-07-19 4
5. COMMANDS
Command Function Description
1 5 N.O. STEP-BY-STEP With DIP1A=OFF and TCMA;, the closinJ of the contact acti-
WITH AUTOMATIC vates openinJ or closinJ operations in the followinJ seTuence:
CLOSING open-stop-close-open.
NOTE: the stop is not permanent but lasts for a duration set
by TC.
STEP-BY-STEP With DIP1A=OFF and TC=MA;, the closinJ of the contact acti-
WITHOUT AUTOMATIC vates openinJ or closinJ operations in the followinJ seTuence:
CLOSING open-stop-close-open.
OPENING WITH With DIP1A=ON and TCMA;, the closinJ of the contact acti-
AUTOMATIC vates the openinJ operation.
CLOSING
OPENING WITHOUT With DIP1A=ON and TC=MA;, the closinJ of the contact acti-
AUTOMATIC vates the openinJ operation.
CLOSING NOTE: once the automation stops, the closing of the contact
performs the opposite operation to the one performed before
stop.
1 6 N.C. SAFETY STOP With DIP5B=ON, all operations are stopped and/or blocNed
when the safet\ contact is opened.
1 6 N.O. CLOSING With DIP5B=OFF, the closinJ of the contact activates the clo-
sinJ operation.
1 8 N.C. REVERSE The openinJ of the safet\ contact triJJers a reversal of motion
SAFETY CONTACT (re-openinJ) durinJ closinJ.
1 9 N.C. STOP The openinJ of the safet\ contact stops the current operation.
1 9 N.O. HOLD-TO-RUN With DIP1A=ON and DIP5B=OFF, the openinJ of the 1-9 con-
FUNCTION tact enables the hold-to-run function.
- hold-to-run openinJ 1-3;
- hold-to-run closinJ 1-4.
NOTE: any safety device, automatic closing and plug-in card
inserted in AUX is disabled.
0 11 N.C. M2 CLOSING With TM=MA;, the openinJ of the contact stops the closinJ
LIMIT SWITCH operation of motor 2 (M2).
With TM=MA; and DIP3B=OFF, the openinJ of the contact
stops the closinJ operation of motor 1 (M1).
0 11 N.O. M2 PROXIMITY See paJe 12-14.
LIMIT SWITCH
0 12 N.C. M1 CLOSING With TM=MAX, the openinJ of the contact stops the closinJ
LIMIT SWITCH operation of motor 1 (M1).
With TM=MAX and DIP3B=OFF, the openinJ of the contact
stops the openinJ operation of motor 1 (M1).
0 12 N.O. M1 PROXIMITY See paJe 12-14.
LIMIT SWITCH
N.O. TRANSMITTERS WARNING: the BIXMR2 storage module must be inserted.
STORAGE AND Transmitter storage:
CANCELLATION - press the PRG Ne\ (the SIG LED comes on),
- transmit the transmitter to be stored (the SIG LED Àashes),
PRG
- wait 10 s to complete storaJe (the SIG LED Joes out).
Transmitter cancellation:
- press the PRG Ne\ for 3 sec (the SIG LED Àashes),
- press the PRG Ne\ for another 3 sec (the SIG LED Àashes
TuicNl\).
WARNING: make a jumper for all the N.C. contacts if not in use. The terminals with the same number
are equal.
5 IP1935EN 2010-07-19
6. OUTPUTS AND ACCESSORIES
Output Value - Accessories Description
Accessories power supply. Power suppl\ output for external ac-
0 1 24 V= / 0,5 A cessories, includinJ automation status lamp.
- +
Open automation lamp. Onl\ with the 0-11 limit switch (N.C.) con-
1 11 24 V= / 3 W nected and DIP3B=OFF the liJht switches off when the automation
is closed.
Closed automation lamp. Onl\ with the 0-12 limit switch (N.C.)
1 12 24 V= / 3 W connected and DIP3B=OFF the liJht switches off when the automa-
tion is open.
Open automation lamp. The liJht switches off when the automation
1 13 24 V= / 3 W
is closed.
Electric lock. Activated upon ever\ openinJ command.
0 15 12 V= / 15 W
LAMP Flashing light. Activated durinJ openinJ and closinJ operations.
W N 230 V~ / 100 W
Courtesy light. In 1 motor mode onl\ (with DIP3B=OFF and no motor
connected to terminals X-=-Y), an external courtes\ liJht that turns
X L 230 V~ / 100 W
on for 180 s with ever\ openinJ (total or partial), step-b\-step and
closinJ command can be connected.
The control panel has one housinJ for pluJ-in cards such as a radio
receiver t\pe, maJnetic loops, etc.
AUX PluJ-in card operatinJ is selected usinJ DIP1A.
WARNING: the plug-in cards must be inserted and removed with the
power supply disconnected.
The storaJe module allows remote controls to be stored.
If the control panel is replaced, the BIXMR2 storaJe module beinJ
COM
BIXMR2 used can be inserted in the new control panel.
WARNING: the storage module must be inserted and removed with
the power supply disconnected.
IP1935EN 2010-07-19 6
7. ADJUSTMENTS
Description OFF ON
DIP1A Command 1-5 operation. Step-b\-step. OpeninJ.
NOTE: it also sets operating mode of the
plugin cards connected on AUX.
DIP2A Restore automatic closing time. 50% 100%
DIP3A Automation status at power on. Open. Closed.
Indicates how the control panel considers NOTE: with limit switches NOTE: if the automatic clo-
automation when powered up. installed, preferably set sing function is not used,
DIP3A=OFF. preferably set DIP3A=ON.
DIP4A Electric lock release. Disabled. Enabled.
DIP1B Maximum power start. Disabled. Enabled.
The motor starts with the The motor starts at maxi-
voltaJe set with trimmer RF. mum power for 1 s.
DIP2B FUTURE USE / /
DIP3B Automation type. 1 motor automation. 2 motors automation.
DIP4B Automation model. FACIL Other automations.
DIP5B Command 1-6 operation. ClosinJ. Stop.
DIP6B Reversal safety switch function. With the automation blo- With the automation blo-
cNed, if the contact 1-8 is cNed, if the contact 1-8 is
open, it is possible to activa- open, an\ operation is im-
te the openinJ operation. possible.
Description OFF ON
JR1 Incorporated radio receiver. Disabled. Enabled.
7 IP1935EN 2010-07-19
Trimmer Description
RF Power adjustment. Adjusts the voltaJe supplied to the motor.
min max
When closinJ, motor 1 (M1) arrives after a dela\ set with trimmer TR relative to motor
2 (M2).
3
s
20
s
When openinJ, motor 2 (M2) starts after a dela\ of 3 s relative to motor 1 (M1).
0s 30 s
With TR=MIN the door winJs start simultaneousl\.
NOTE: setting TR=MIN with non-overlapping door wings and setting TR>3 s with
overlapping door wings is recommended.
R1 Obstacle thrust adjustment.
The control panel is eTuipped with a safet\ s\stem that stops motion if an obstacle is
min Disabled encountered durinJ an openinJ operation and stops or inverts the movement durinJ
a closinJ operation.
R1=MIN Jives maximum obstacle sensitivit\ (minimum thrust).
R1=MAX disables obstacle detection (maximum thrust).
TC Setting automatic closing time. From 0 to 120 s.
s
With DIP2A=OFF, once a safet\ switch has been activated, the counter starts as soon
0
12
as the safet\ switch is released (for example after passinJ throuJh the photocells),
0s Disabled
and lasts for a period of time set with trimmer TC (50%).
With DIP2A=ON, the counter starts when automation is opened and lasts for the entire
duration set with trimmer TC (100%).
NOTE: after the activation of the stop command, once contact 1-9 has closed again,
automatic closing is only enabled after a total, partial or step-by-step opening com-
mand.
TM Operation time adjustment. From 10 to 120 s.
s
60
LED On Flashing
SIG Transmitter enablinJ/storaJe phase. Reception of a radio transmission.
Cancellation of transmitters in proJress.
BIXMR2 memor\ damaJed.
IN Receipt of command or chanJe in status of
/
a dip-switch.
11 0-11 limit switch contact is open.
/
12 0-12 limit switch contact is open.
/
SA At least one of the safet\ contacts is open. Operations count performed (onl\ when con-
trol panel is switched on):
each rapid Àash = 1000 operations
each slow Àash = 10000 operations
POWER Power suppl\ on.
/
IP1935EN 2010-07-19 8
8. RADIO RECEIVER OPERATION
The control panel is eTuipped with a radio receiver with a freTuenc\ of 433.92 MH]. The antenna consists of
a 173 mm lonJ riJid wire.
It is possible to increase the ranJe of the radio b\ connectinJ the external antenna of the ÀashinJ liJhts, or b\
installinJ the tuned antenna (BIXAL).
NOTE: to connect the external antenna to the control panel, use a coaxial cable type RG58 (max 10 m).
Up to 200 remote controls can be stored in the BIXMR2 storaJe module.
WARNING: if the radio receiver on the control panel is not used, set JR1=OFF and remove the storage mo-
dule.
Refer to the transmitters user manual to store, clone and delete transmitters.
From one to four CH Ne\s of a sinJle transmitter can be stored in the control panel.
If onl\ one (an\) CH Ne\ of the transmitter is stored, command 1-5 (step-b\-step/openinJ) is carried out.
If from two to four CH Ne\s of a sinJle transmitter are stored, the functions matched with the CH Ne\s are as
follows:
- CH1 = command 1-5 step-b\-step/openinJ;
- CH2 = partial openinJ command, it causes the automation to open for about 8 s;
- CH3 = command to switch on/off the courtes\ liJht;
- CH4 = stop command, eTuivalent to impulsive command 1-9.
If the control panel is replaced, the BIXMR2 storaJe module beinJ used can be inserted in the new control
panel.
WARNING: the BIXMR2 storage module must be inserted and removed with the power supply disconnected.
9. START-UP
WARNING The operations in point 5 are performed without safety devices.
The trimmer can only be adjusted with the automation idle.
1- MaNe a jumper for the N.C. safet\ contacts.
2- ChecN the application t\pe selected.
3- If installed, adjust the openinJ and closinJ stop limit switches.
NOTE: limit switches must be kept pressed until the operation has been completed.
4- Set TR!3 s in case of automation with two overlappinJ door winJs.
5- Switch on and checN that the automation is operatinJ correctl\ with subseTuent openinJ and closinJ
commands.
If installed, checN that the limit switches are activated.
NOTE: if the direction of rotation of the motor is incorrect for the desired direction of the automation, swap
the U-V or X-Y phases.
6- Connect the safet\ devices (removinJ the relative jumpers) and checN the\ worN correctl\.
7- If reTuired, adjust the automatic closinJ time with the TC trimmer.
WARNING: the automatic closing time after a safety device has triggered depends on the DIP2A setting.
8- Set RF trimmer to a position that allows the automation to function correctl\ while ensurinJ the safet\ of
the user in the event of collision.
9- Set the obstacle thrust with the R1 trimmer.
NOTE: if the door wing closing second encounters an obstacle, both door wings are reopen and the sub-
sequent closing operation is performed one door wing at a time.
WARNING: check that the working forces exerted by the door wings are compliant with EN12453-EN12445
regulations.
10- Connect an\ other accessories and checN the\ operate correctl\.
11- Once the start-up and checN procedures are completed, close the container.
i NOTE: in the event of servicing or if the control panel is to be replaced, repeat the start-up procedure.
9 IP1935EN 2010-07-19
10. TROUBLESHOOTING
Problem Possible causes Remedy
The automation does not No power. ChecN that the control panel is powe-
open or close. (POWER led off). red correctl\.
Short circuited accessories. Disconnect all accessories from termi-
(POWER led off). nals 0-1 (voltaJe must be 24 V=) and
reconnect one at a time.
Blown line fuse. Replace F1 fuse.
(POWER led off).
Safet\ contacts are open. ChecN that the safet\ contacts are clo-
(SA led on). sed correctl\ (N.C.).
The remote control does not worN. ChecN the correct memori]ation of the
transmitters on the incorporated radio.
If there is a fault with the radio receiver
that is incorporated in the control panel,
the radio control code can be read b\
removinJ the storaJe module.
The automation opens but Safet\ contacts are open. ChecN that the safet\ contacts are clo-
does not close. (SA led on). sed correctl\ (N.C.).
Photocells are activated. ChecN that the photocells are clean and
(SA led on). operatinJ correctl\.
The automatic closinJ does not worN. ChecN that the TC trimmer is not set at
the maximum.
The automation is ver\ The motor’s condenser has an incor- Replace the motor’s condenser.
weaN and does not invert rect capacit\ value.
the movement.
External safet\ devices not Incorrect connections between the Connect N.C. safet\ devices toJether in
activatinJ. photocells and the control panel. series and remove an\ bridJes on the
control panel terminal board.
The remote control has li- The radio transmission is impeded b\ Install the antenna outside. Substitute
mited ranJe and does not metal structures and reinforced con- the transmitter batteries.
worN with the automation crete walls.
movinJ.
IP1935EN 2010-07-19 10
11. EXAMPLE APPLICATION FOR GATES WITH ONE SWINGING DOOR WING
B DIP3B=OFF
ON
OFF 1 2 3 4 5 6
A
When the control panel is used in applications with R1<MAX
TM<MAX ON
one swinJinJ door winJ, one of the followinJ operatinJ OFF 1 2 3 4
modes ma\ be selected: R1 TM
(230V - 5A)
(Fig. 11.3) Door wing stops against limit switches
and inverts in the event of obstacle detection.
Set an operatinJ time TM=MAX and connect the
openinJ and closinJ limit switches N.C. contacts to 230V~
terminals 0-11-12.
Motor 1 FiJ. 11.2
In this con¿Juration, the door winJ stops when the
limit switches are activated. In the event of obstacle
detection while openinJ, the door winJ stops, perfor- B
minJ a disenJaJement operation, whereas durinJ ON
DIP3B=OFF
a closinJ operation, the door winJ reopens. OFF 1 2 3 4 5 6
A
R1<MAX
TM=MAX ON
OFF 1 2 3 4
R1 TM
15 13 12 11 0 1 1 5 6 8 9
Opening limit switch
Closing limit switch
FiJ. 11.3
11 IP1935EN 2010-07-19
(Fig. 11.4) Door wing stops against mechanical stops
and inverts in the event of obstacle detection. B
Set an operatinJ time of 2-3 s lonJer than the ef- ON
DIP3B=OFF
fective time taNen b\ the door winJ (TMMAX) and OFF 1 2 3 4 5 6
limit switch
detection before the proximit\ switch operates, the (230V - 5A)
Closing proximity switch
Motor 1
FiJ. 11.5
IP1935EN 2010-07-19 12
12. EXAMPLE APPLICATION FOR GATES WITH TWO SWINGING DOOR WINGS
TR>3 s
R1<MAX
TM<MAX
TR R1 TM
When the control panel is used in applications with two
overlappinJ swinJinJ door winJs, one of the followinJ
operatinJ modes ma\ be selected: 15 13 12 11 0 1 1 5 6 8 9
com
230V~ 230V~
Motor 1 Motor 2
FiJ. 12.3
13 IP1935EN 2010-07-19
(Fig. 12.4) Door wings stop against mechanical stops
and invert in the event of obstacle detection.
Set an operatinJ time 2-3 s Jreater than the effective TR>3 s
time taNen b\ the door winJs (TMMAX) and connect R1<MAX
TM<MAX
the closinJ proximit\ switch N.O. contacts to termi- TR R1 TM
nals 0-11-12, positioninJ the proximit\ switches 2-3
s ahead of the mechanical stop.
In this con¿Juration, each door winJ stops aJainst its 15 13 12 11 0 1 1 5 6 8 9
respective mechanical closinJ and openinJ stop.
In the event of obstacle detection while openinJ,
onl\ the door winJ that detects the obstacle stops,
performinJ a disenJaJement operation.
com
IP1935EN 2010-07-19 14
13. HOLD-TO-RUN FUNCTION MODE
B DIP5B=OFF
ON
OFF 1 2 3 4 5 6
A
i NOTE: to use the control panel in hold-to-run
mode, disconnect terminal 9.
R1<MAX
TM=MAX ON
OFF 1 2 3 4
DIP1A=ON
15 IP1935EN 2010-07-19
IP1935EN - 2010-07-19
Entrematic Group AB
Lodjursgatan 10
SE-261 44, Landskrona
Sweden