C o m p a c t 1 5 0 Watt Enclosed Switching Power Supplies mk150s series

Universal 88-264VAC Auto Range Input

Compact Footprint

High Efficiency

Regulated Outputs

3000V Isolation

Built in EMI Filter

3.5”W x 6”L x 1.75”H

Model Number Output Voltage Output Amps (max) Ripple/Noise pp,typ

MK150S-5 5 VDC 30 100mv


MK150S-12 12 VDC 12.5 100mv
MK150S-15 15 VDC 10 100mv
MK150S-24 24 VDC 6 100mv

Order On-Line!
astrodyne.com 300 Myles Standish Blvd., Taunton, MA 02780
WWW.ASTRODYNE.COM Ph: 1-800-823-8082 Fax: 508-823-8181
C o m p a c t 1 5 0 Watt Enclosed Switching Power Supplies mk150s series

INPUT SPECIFICATIONS ENVIRONMENTAL SPECIFICATIONS

Input Voltage Range 88-132/176-264 VAC Oper. Temperature 0 to +60°C


Auto Voltage Select (See Derate Curve)
Frequency Range 47-63 Hz Storage Temperature -25 to +85°C *
Inrush Current, typ: 20A @ 100VAC * Relative Humidity 10% to 90%, non-cond *
40A @ 200VAC * EMI (Designed to Meet) EN55011, Class B
MTBF 100,000 Hrs
OUTPUT SPECIFICATIONS Mil Std 217, 25°C

Voltage and Current See Selection Chart PHYSICAL SPECIFICATIONS


Line/Load Regulation (10%-FL) ± 0.5%, typ
Voltage Tolerance ± 1%, typ Size 6” x 3.5” x 1.75”
DC Voltage Adjust (typ) ± 6%, typ Construction Enclosed
Temperature Coefficient ± 0.03%/°C Weight 1.37 lb, (630g)
Ripple/Noise 100mV, typ
Over Voltage Protection 130%, Latching, Re-power *
Short Circuit Protection 160%, Indefinite
Hold Up Time 20mS, typ (Nom I/P, FL)
Turn On Time ≤ 1.0 sec, typ
Rise Time ≤ 20 msec, typ
Over/Under Shoot < 10% of FS

GENERAL SPECIFICATIONS

Isolation I/P-O/P: 3000VAC


I/P-Ground: 1500VAC
O/P-Ground: 500 VAC
Efficiency 78%, typ
Switching Frequency 100Khz, (fixed, typical)
Safety EN60950, IEC60950
UL60950

All specifications are typical at nominal input, full load, and 25°C unless other-
wise noted Astrodyne products are not authorized or warranteed for use
as critical components in life support systems, equipment used
* These are stress ratings. Exposure of the devices to any of these conditions in hazardous environments, nuclear controls systems, or other
may adversely affect long term reliability. Proper operation under conditions
mission-critical applications.
other than the standard operating conditions is neither warranteed nor implied.

300 Myles Standish Blvd., Taunton, MA 02780


WWW.ASTRODYNE.COM Ph: 1-800-823-8082 Fax: 508-823-8181
C o m p a c t 1 5 0 Watt Enclosed Switching Power Supplies mk150s series

MECHANICAL DIMENSIONS
Pin # Outputs

1 ACL
2 ACN
3 GND
4 + Output
5 + Output
6 - Output
7 - Output

PLEASE NOTE:
To improve specifications and safety isolation, connection
designations may have changed from prior revisions. Please
verify connections per product labels on input and output
connections prior to applying power to the unit
OUTPUT DERATING CURVE
(Forced air cooling direction: Straight down from top of unit)

1 22CFM Forced Air - All Outputs (Recommended)


2 12/15/24VDC Outputs, Convection Cooled
3 5VDC Output, Convection Cooled

120
1
100

80
Load, %

60
2
40
3
20

0
0 5 10 15 20 25 30 35 40 45 50 55 60

Ambient Temp, C

300 Myles Standish Blvd., Taunton, MA 02780


WWW.ASTRODYNE.COM Ph: 1-800-823-8082 Fax: 508-823-8181