Current Transducer Weidmuller ACT20P CML 10 AO RC S
Current Transducer Weidmuller ACT20P CML 10 AO RC S
Current Transducer Weidmuller ACT20P CML 10 AO RC S
Data sheet
ACT20P Weidmüller Interface GmbH & Co. KG
Klingenbergstraße 16
ACT20P-CML-10-AO-RC-S D-32758 Detmold
Germany
Fon: +49 5231 14-0
Fax: +49 5231 14-292083
www.weidmueller.com
Product image
Technical data www.weidmueller.com
Temperatures
Humidity 5...95 %, no condensation Operating temperature, max. 60 °C
Operating temperature, min. -25 °C Storage temperature, max. 85 °C
Storage temperature, min. -40 °C Operating temperature -25 °C...60 °C
Ambient temperature -25 °C...+70 °C Storage temperature -40 °C...85 °C
Probability of failure
MTTF 130 Years
Input
Number of inputs Input signal Power cable can be
1 connected to the terminals
Input measurement range Input frequency AC: 15…400 Hz (true root
configurable, 0…1/5/10 A mean square), AC: 50 Hz
AC (RMS) or DC (arithmetic average)
General data
Accuracy ≤ ±0.3 % @ 1 A ⁄ 5 A, ≤ Configuration DIP switch and
±0.6 % @ 10 A potentiometer
Galvanic isolation 4-way isolator;, between Power consumption, max.
input ⁄ output ⁄ supply ⁄
relay 2.2 W
Rail Step response time ≤ 300 ms (RMS), ≤ 60 ms
TS 35 (AA)
Temperature coefficient ≤ ±100 ppm⁄K @ -25… Voltage supply
+55 °C, ≤ ±200 ppm/K @
+55…+70 °C 16,8 V…31,2 V
Insulation coordination
EMC standards Galvanic isolation 4-way isolator;, between
IEC 61326-1, IEC input ⁄ output ⁄ supply ⁄
61010-2-201 relay
Impulse withstand voltage 6 kV (1.2/50 µs) Insulation voltage 4 kVeff / 1 min.
Pollution severity 2 Rated voltage 300 V ACrms
Surge voltage category III Test voltage 4 kV
Technical data www.weidmueller.com
Output (analogue)
Load resistance current ≤ 600 Ω Load resistance voltage ≥ 10 kΩ
Output current Output voltage adjustable, 0...10 V, 2…10
adjustable, 0...20 mA, V, 0...5 V, 1...5 V, -5…+5 V,
4...20 mA, -20…+20 mA -10...+10 V
Type (analogue output) Voltage and current output
(configurable)
Output (digital)
Alarm function Surge current, Under- Number of digital outputs
current, Alarm delay: 0…10
s 1
Type Relay, 1 CO contact, Max. switching voltage, DC
normal / inverse
adjustment 24 V
Max. switching voltage, AC 250 V Rated switching current 2A
Connection data
Type of connection Screw connection Tightening torque, min. 0.4 Nm
Tightening torque, max. 0.6 Nm Clamping range, rated connection 1.5 mm²
Clamping range, min. 0.5 mm² Clamping range, max. 2.5 mm²
Wire connection cross section AWG, Wire connection cross section AWG,
min.
AWG 26 max. AWG 12
Classifications
ETIM 6.0 EC002475 eClass 6.2 27-21-09-02
eClass 9.0 27-21-01-23 eClass 9.1 27-21-01-23
Product information
Product information The device ACT20P-CML-10-AO-RC-S measures and monitors AC and DC currents of up to 10 A. The real
effective value method used allows for precise measurement, even for distorted current curve shapes. The
device features an integrated limit value monitoring function with an adjustable switching threshold, lag and
hysteresis, as well as a relay output.
Features
• Real effective value measurement (True RMS) or arithmetic averaging (AA) measurement
• Limit value monitoring for overcurrent or undercurrent
• Relay output by means of the open-circuit / closed-circuit principle
• Adjustable trigger delay for filtering current peaks
• Operational status and error display on a front panel LED and output signalling according to NE43, NE44,
NE107
• Galvanic four-way insulation for secure isolation according to IEC/EN 61010-2-201
Approvals
Approvals
ROHS
Conform
Technical data www.weidmueller.com
Downloads
Approval/Certificate/Document of DNV GL certification
Conformity Declaration of Conformity
Engineering Data EPLAN
Engineering Data STEP
Software DIP switch configuration tool
User Documentation
Instruction sheet
Drawings www.weidmueller.com