Doppler 450kg, 10F
Doppler 450kg, 10F
Doppler 450kg, 10F
450 KG
DOPPLER
PASSENGER ELEVATOR
ELEVATOR
6 PERSONS (450 KG), G+9
To
Owners of Meraznagar Tower One,
Meraznagar, Rayerbaag,
Kadamtali, Dhaka.
SUBJECT : Offer for Supply, Installation, Testing & Commissioning of 01 (One) Set of Doppler Passenger lift.
Dear Sir,
With reference to your requirement on captioned subject and subsequent site survey, we have the pleasure to attach
herewith our offer of elevator for your prestigious project.
Maxford provides comprehensive and qualified testing, certification, inspection, consulting and training services for all
types of lifts, escalators and moving walkways. Our end-to-end approach will meet all relevant quality standards and
order specifications. Our services offer substantial cost savings while satisfying safety and reliability requirements.
We possess a long history of reputation on Electrical sub-station projects, Diesel Generators, Elevators, Industrial
Electrical & Mechanical Erection - through best in class technology supported by our experienced professionals. Our
company has reflected itself with its quality control process, value added services, after sales services, product ranges,
instant customer supports and many more facilities.
We assure you about our quality products & services at all times. Please contact us if you need to clarify anything.
____________________________ ____________________________
Mohammad Mohiuddin Abu Tareq Mahmud
Asst. Manager, Technical Manager, Operation
Direct Call: +88 0199 65 43 500 Direct Call: +88 0130 86 33 783
Enclosure:
1. Commercial offer.
2. Technical features
Suite # 13E, 13th floor, Confidence Center Hotline:01996543500 Query: Maxford.energy@gmail.com http://www.maxfordbd.com
(Building -2), Shahjadpur, Gulshan, Dhaka. Plight: 01308633783 General: maxford.bd@gmail.com facebook.com/maxfordbd
COMMERCIAL OFFER FOR SUPPLY AND INSTALLATION OF
1 (ONE) PASSENGER LIFT (6 PERSON, 10 FLOOR/STOP)
Brand:
NOTE: The above price is INCLUSIVE of L/C Charge, Custom Duty, Insurance, C&F Commission, Loading-Unloading, Carrying up to site.
This price INCLUDES installation, Testing, Commissioning & handover of the Cargo Lift. Local Source Tax (VAT & AIT) is NOT
INCLUDED in the above price. If there is any change in the exchange rate at the time of L/C opening & custom clearance, it will be on Buyer’s
account.
Suite # 13E, 13th floor, Confidence Center Hotline:01996543500 Query: Maxford.energy@gmail.com http://www.maxfordbd.com
(Building -2), Shahjadpur, Gulshan, Dhaka. Plight: 01308633783 General: maxford.bd@gmail.com facebook.com/maxfordbd
TERMS
OF SALE
TERMS CONDITIONS
Delivery Maximum 90 working days after Opening L/C or Advanced Payment.
Maintenance Maxford will provide after sales services i.e trouble-shooting, maintenance &
servicing within the warranty period.
After completion of warranty period service charge will be provided by the
customer through negotiation.
Free Servicing Maxford will conduct 12 free servicing for the first 12 months after hand over. After
12 free servicing, customer will need to have an agreement with Maxford for
continuation of monthly servicing at a cost of 3000/- per month.
Suite # 13E, 13th floor, Confidence Center Hotline:01996543500 Query: Maxford.energy@gmail.com http://www.maxfordbd.com
(Building -2), Shahjadpur, Gulshan, Dhaka. Plight: 01308633783 General: maxford.bd@gmail.com facebook.com/maxfordbd
Passenger Lifts.
Your Heavyweight Choice!
➢ Stiffness
➢ Safety
➢ Reliability
➢ Aesthetic
➢ Ease of installation
Materials such as galvanized, epoxy painted steel sheet or even stainless
steel can be used, which stand out for high durability and protection from
damage due to frequent , heavy and long term use. They are mainly used
for heavy duty industrial applications, warehouses, super markets,
parking’s, hospitals and commercial centers.
Suite # 13E, 13th floor, Confidence Center Hotline:01996543500 Query: Maxford.energy@gmail.com http://www.maxfordbd.com
(Building -2), Shahjadpur, Gulshan, Dhaka. Plight: 01308633783 General: maxford.bd@gmail.com facebook.com/maxfordbd
SERVICING
AND
MAINTENANCE
Suite # 13E, 13th floor, Confidence Center Hotline:01996543500 Query: Maxford.energy@gmail.com http://www.maxfordbd.com
(Building -2), Shahjadpur, Gulshan, Dhaka. Plight: 01308633783 General: maxford.bd@gmail.com facebook.com/maxfordbd
BASIC ARRANGEMENTS OF MAJOR COMPONENTS
This part is to introduce to our customer the Major components of an Elevator and how they are
placed. So that, customer may have a clear concept about elevator operation.
Suite # 13E, 13th floor, Confidence Center Hotline:01996543500 Query: Maxford.energy@gmail.com http://www.maxfordbd.com
(Building -2), Shahjadpur, Gulshan, Dhaka. Plight: 01308633783 General: maxford.bd@gmail.com facebook.com/maxfordbd
Technical Specifications.
Our product range comprises both traction and hydraulic lifts for the
transportation of passengers, cars as well as small and heavy freight.
Traction MR.
Features:
▶ Speed up to 2 m/sec
▶ Travel up to 100m
Suite # 13E, 13th floor, Confidence Center Hotline:01996543500 Query: Maxford.energy@gmail.com http://www.maxfordbd.com
(Building -2), Shahjadpur, Gulshan, Dhaka. Plight: 01308633783 General: maxford.bd@gmail.com facebook.com/maxfordbd
MAIN PARAMETERS
Type of lift Passenger Lift
Load 450 KG
Driving System Traction type geared AC VVVF (Variable Voltage Variable Frequency - which is
an advanced electronic technology for smooth travelling, comfort on stopping and
reduced cost resulting from low power consumption drive)
Suite # 13E, 13th floor, Confidence Center Hotline:01996543500 Query: Maxford.energy@gmail.com http://www.maxfordbd.com
(Building -2), Shahjadpur, Gulshan, Dhaka. Plight: 01308633783 General: maxford.bd@gmail.com facebook.com/maxfordbd
MOTOR
Traction Machine VVVF GEARLESS, 4.2 KW
Description
Greek market - Exports to 10% - 90% from 70% - 30% in 2008! Russia and Great Britain are the top
exporting markets while some of the main markets Ever since its establishment, DOPPLER has been
setting high goals which led to a strong and profound presence on the global map and products in more
than 60 countries. With its high quality in production and its competitive prices, DOPPLER is
increasingly “lifting” and has succeeded to form its ratio of the are Northern Europe, Balkan countries
and CIS states. In 2010, DOPPLER entered into North and South Africa, the Middle Eastern countries
(GCC), India, Iraq, Pakistan and Australia. DOPPLER is also planning to expand its activities both in
Central Africa and South America.
Suite # 13E, 13th floor, Confidence Center Hotline:01996543500 Query: Maxford.energy@gmail.com http://www.maxfordbd.com
(Building -2), Shahjadpur, Gulshan, Dhaka. Plight: 01308633783 General: maxford.bd@gmail.com facebook.com/maxfordbd
SHAFT
Construction Concrete / Brick wall.
Shaft Size (W) 1549mm (w) ×1905 (D) mm.
(As Required).
Suite # 13E, 13th floor, Confidence Center Hotline:01996543500 Query: Maxford.energy@gmail.com http://www.maxfordbd.com
(Building -2), Shahjadpur, Gulshan, Dhaka. Plight: 01308633783 General: maxford.bd@gmail.com facebook.com/maxfordbd
Cabin
Type As per catalog
**These are the standard measurements. Actual dimension will be based on the measurement of shaft.
Cabins.
Elevating in style
Suite # 13E, 13th floor, Confidence Center Hotline:01996543500 Query: Maxford.energy@gmail.com http://www.maxfordbd.com
(Building -2), Shahjadpur, Gulshan, Dhaka. Plight: 01308633783 General: maxford.bd@gmail.com facebook.com/maxfordbd
Handrails.
HR3 HR4
Corners.
Suite # 13E, 13th floor, Confidence Center Hotline:01996543500 Query: Maxford.energy@gmail.com http://www.maxfordbd.com
(Building -2), Shahjadpur, Gulshan, Dhaka. Plight: 01308633783 General: maxford.bd@gmail.com facebook.com/maxfordbd
Car Door
Entrance One
Landing door
Open style Straight , automatic sliding, center, 2 panel
Door size Type Doppler: width 700 x height 2300 or (as required)
Door frame Door frames normal, inox satin antimagnetic 304 : 10 pieces,
**These are the standard measurements. Actual dimension will be based on the measurement of shaft.
Suite # 13E, 13th floor, Confidence Center Hotline:01996543500 Query: Maxford.energy@gmail.com http://www.maxfordbd.com
(Building -2), Shahjadpur, Gulshan, Dhaka. Plight: 01308633783 General: maxford.bd@gmail.com facebook.com/maxfordbd
Doors.
Fully Automatic Sliding Car & Landing Doors
Suite # 13E, 13th floor, Confidence Center Hotline:01996543500 Query: Maxford.energy@gmail.com http://www.maxfordbd.com
(Building -2), Shahjadpur, Gulshan, Dhaka. Plight: 01308633783 General: maxford.bd@gmail.com facebook.com/maxfordbd
Operation Panel
Button Square / round push button
Indicator Dot matrix indicator
Emergency Lighting Yes
Intercom Intercom 3 phones 1 speaker
Emergency Button Yes
Car Operating Panel Column, doppler, inox st.st satin 441 included:
Kind of display : LCD
Lighting : BLUE
Arrows
Overload
Full load indication
Door open
Door close
Fan switch
Emergency light
Landing Operating Main floor : wall mounted dplw, inox satin antimagnetic 304,
Panel One button up, without arrows, without display, serial, blue,1 pieces
Upper floor : wall mounted dplw, inox satin antimagnetic 304,
One button down, without arrows, without display, serial, blue,1 pieces
Lop on wall
Hall lantern: 2 pieces
No entry: 1 pieces
Suite # 13E, 13th floor, Confidence Center Hotline:01996543500 Query: Maxford.energy@gmail.com http://www.maxfordbd.com
(Building -2), Shahjadpur, Gulshan, Dhaka. Plight: 01308633783 General: maxford.bd@gmail.com facebook.com/maxfordbd
Others
Over speed governor Dynatech Vega φ200 24v, Vega tension φ200
Suite # 13E, 13th floor, Confidence Center Hotline:01996543500 Query: Maxford.energy@gmail.com http://www.maxfordbd.com
(Building -2), Shahjadpur, Gulshan, Dhaka. Plight: 01308633783 General: maxford.bd@gmail.com facebook.com/maxfordbd
The GEFRAN Inverters designed for new installations and
upgrades, are the ideal system for a wide range of applications, Suitable for Hydraulic and Traction lifts ▶ Up to 64 stops
including very low rise (home lifts) or very high rise (skyscrapers) Parallel, cabin serial, cabin & landings serial communication
Internal 3-phase and thermistor monitoring circuits ▶ Real-time
clock & date Internal Door Bridging controller for hydraulic
applications Two doors independent control ▶ Voice Announcer
▶ Emergency Rescue Operation In conformity with EN81-70,
EN81-72 (firefighter lifts standard), EN81-73 Special software for
lift access security
Suite # 13E, 13th floor, Confidence Center Hotline:01996543500 Query: Maxford.energy@gmail.com http://www.maxfordbd.com
(Building -2), Shahjadpur, Gulshan, Dhaka. Plight: 01308633783 General: maxford.bd@gmail.com facebook.com/maxfordbd
RECO+ (Kinetic Energy Recovering System)
Suitable for:
Traction lifts driven by inverter ▶ Synchronous & Asynchronous motors ▶ New
installations & modernizations Standard models could be used for lift ups to
1.000kg and for travel up to 70m ▶ Unique Emergency Rescue Function
TALK2LIFT
Talk2Lift can be adjusted on the electronic board of any elevator cabin.
The cabin holds an “extra button” which upon pressing prompts the passenger to
pronounce their destination.
A wide variety of facades makes it easy to match any elevator cabin
Suite # 13E, 13th floor, Confidence Center Hotline:01996543500 Query: Maxford.energy@gmail.com http://www.maxfordbd.com
(Building -2), Shahjadpur, Gulshan, Dhaka. Plight: 01308633783 General: maxford.bd@gmail.com facebook.com/maxfordbd
Safety Feature
Distance The car and hoist way door distance minimum 30mm.
Guide Rail Special T-shaped solid steel guide rails for car and hollow for counter weight. Diameter 10mm
for Car and 16mm hollow for counter weight. The rails will be fixed with guide rail brackets and
clamps.
Ropes Hoisting ropes of the lift will be provided with bright steel wire rope with safety factor of at least
14. The over speed governor rope will be bright steel wire rope with fiber core having safety
factor of at least 8.
Speed The safety will be operated by a speed governor located at the top of the hoist way and connected
to the safety gear through a continuous steel rope. If any unusual acceleration causes the
governor &
governor cuts off the power of control panel and grasp the governor rope & activates
Safety gear emergency safety gear.
Buffer Hydraulic buffer energy absorbing type will be provided at the bottom of the shaft. If the car
should travel beyond the lowest floor. The buffer reduces the shock of touching cabin &
counterweight frame.
Evacuation During a power failure the car will move automatically by ARD to the nearest higher or lower
landing door to facilitate evacuation of passengers.
Over-load If the car is the overloaded the car will not start and necessarily indicate overload condition by
control sounding buzzer.
Battery A trickle charge battery for 30 minute service provide for emergency light, Alarm & intercom.
Main switch As motor protection and also to disconnect main power supply of motor.
Pre-limit When magnetic contactor fails to take slow speed to top or bottom floor, pre-limit switch helps to
switch take slow speed landing.
Final-limit Final limit switch will cut off main power of motor and stop all function of lift.
switch
Phase Failure If any phase of the main power supply is cut off, for the safety of the lift & it’s passenger this
Protection protection switch does not provide power supply to control circuit and the lift does not start.
Phase If the phase is changed by any external subject such as PDB etc. for the safety of the lift & it’s
Reversal passenger this protection switch cut off the main power supply to the control circuit and the lift
does not start.
protection
Suite # 13E, 13th floor, Confidence Center Hotline:01996543500 Query: Maxford.energy@gmail.com http://www.maxfordbd.com
(Building -2), Shahjadpur, Gulshan, Dhaka. Plight: 01308633783 General: maxford.bd@gmail.com facebook.com/maxfordbd
Functions
STANDARD OPTIONS
1 Automatic opening in commanded floor
2 Door hold open time
3 Automatic door opening
4 Door close button quick close
5 Door open button
6 Hall call door reopen
7 Automatic light and fan timer
8 Setup of service floor
9 Attendant control priority
10 Floor indicator
11 Direction indicator
12 Lock service in car
13 No opening out of door zone
14 Light screen protection
15 Overload protection
16 Terminal switch over the travel protection
17 Emergency call in car
18 Intercom
19 Emergency lighting
20 Phase loss protection
21 Over speed protection
22 Motor over heat protection
23 With driver operation
24 Inspection travel
25 Over load Alarm
26 Defect auto diagnosis
27 Landing call trim button
28 Door opening time adjustable
29 Main switch
Suite # 13E, 13th floor, Confidence Center Hotline:01996543500 Query: Maxford.energy@gmail.com http://www.maxfordbd.com
(Building -2), Shahjadpur, Gulshan, Dhaka. Plight: 01308633783 General: maxford.bd@gmail.com facebook.com/maxfordbd
The works below are not included in the elevator installation work and should be carried out by the building
contractors in accordance with our drawing, relevant international or local codes.
• Construction of lift shaft, machine room and shaft ceiling according to layout drawings. Shaft steel
structure and shaft cladding to be supplied and designed by others, if required.
• One Front wall at the main landing is not to be constructed until after all elevator materials are
located in the hoist way. Remaining front entrance walls shall not be constructed until after door
frames and sills are in place. If front walls are poured concrete bearing wall, rough openings are to be
provided to accept entrance frames and filled in after frames are set. Rough opening shall be suit the
elevator contractor.
• Plumb-line tolerance over the whole hoist way must not exceed +30 mm
• Final civil work/Finishing work of the landing doors and any others civil jobs if required.
• Any type of breaking of civil work will be done by the building owner or civil contractor.
• Cooling system of machine room and hoist way, temperature must be between Maximum 45 degree
& Minimum 5 degree.
• Lighting and socket out let in machine room.
• A three phase, four wire electrical feeder system with an equipment grounding conductor terminating
in the machine room, size of the feeder and grounding to suit elevator power characteristics.
• Supply of the main switch, MCCB, DB box adequate earth line.
• Electrical power in machine room for installation. The electrical power line should be 380 volts, 3
phases up to machine room; circuit breaker will be 40 amps.
• Permanent power supply 2 week after start of installation for trial & run.
• Lockable store for keeping installation materials.
• Water facility in the premise for using for installation people cleanness.
• Security of the installation people in the area and security material.
• Supply and installation of fall-prevention plate at the hoist entrance.
• Provision of ladder in case deep pit.
• Provision of fire extinguisher in the machine room.
Suite # 13E, 13th floor, Confidence Center Hotline:01996543500 Query: Maxford.energy@gmail.com http://www.maxfordbd.com
(Building -2), Shahjadpur, Gulshan, Dhaka. Plight: 01308633783 General: maxford.bd@gmail.com facebook.com/maxfordbd
WHAT ACTUALLY YOU ARE GETTING FROM MAXFORD?
Please take the right decision for the sake of your project’s safety and perfection.
Thank you.
From - Maxford Team
FB: facebook.com/maxford.energy
Suite # 13E, 13th floor, Confidence Center Hotline:01996543500 Query: Maxford.energy@gmail.com http://www.maxfordbd.com
(Building -2), Shahjadpur, Gulshan, Dhaka. Plight: 01308633783 General: maxford.bd@gmail.com facebook.com/maxfordbd