Catalogue Export 2020 GB - 906131100 - BD
Catalogue Export 2020 GB - 906131100 - BD
Catalogue Export 2020 GB - 906131100 - BD
6 expert measurement
companies in one Group
Portable Electrical measuring Sensors and control Metrology and Optical sensors for Measurement of agri-
instrumentation for instruments and solutions for industrial regulatory testing. quality control in the food product quality
measuring electrical supervision solutions for processes Measurement services laboratory and on in- using fluorescence and
and physical quantities demanding industries (noise, air, water) line processes Infrared processes
and environments
contents
Multimeters
• Clamp multimeters. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
• Multimeters. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
TESTERS
• LED voltage tester. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
• Digital testers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
PHYSICAL MEASUREMENTS
• Contact thermometers. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
• Thermo-hygrometers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
• Measurement of CO2 / Temperature / Humidity . . . . . . . . . . . . . . . . . . . . . . . . . . 12
• Luxmeters. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
• Thermo-anemometers. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
ELECTROCHEMISTRY
• pH and temperature testers. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
• Conductivity meter. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
• Portable pH-meter. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
THERMOGRAPHY
• DiaCAm2 thermal cameras . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Oscilloscopes
• Portable oscilloscopes. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
Current measurements
• AC and AC/DC current measurements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
• Measurements with oscilloscopes. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
• Ammeters with flexible sensors. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
• Flexible current sensors. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41
Accessories
• Measurement leads, protection and transport accessories . . . . . . . . . . . . . . . . . 42
1000 V IP
CAT IV 54
4
F201 F203 F205 F401 F403 F405 F407 F603 F605 F607
Reference P01120921 P01120923 P01120925 P01120941 P01120943 P01120945 P01120947 P01120963 P01120965 P01120967
Specifications
Clamping diameter Ø 34 mm Ø 48 mm Ø 60 mm
Display LCD Backlit LCD Backlit LCD Backlit LCD
Resolution 6,000 counts 10,000 counts 10,000 counts
Number of values displayed 1 1 3 1 3
TRMS
TRMS TRMS TRMS TRMS TRMS TRMS TRMS
Type of acquisition [AC, AC+DC]
[AC] [AC]/DC [AC] [AC]/DC [AC, AC+DC]/DC [AC]/DC [AC, AC+DC]/DC
/DC
Autorange function Yes Yes Yes
Automatic AC/DC detection Yes Yes Yes
Aac 0.15 to 600 A (900 A peak) 1 000 A 2 ,000 A (3 ,000 A peak)
Adc 0.15 to 900 A peak 1,500 A peak 3, 000 A
0.15 to 600 A 1,000 A 2,000 A
Aac+dc
(900 A peak) (1,500 A peak) (3,000 A peak)
Best accuracy 1 % R + 3 counts 1 % R + 3 counts 1 % R + 3 counts
Vac 0.15 to 1,000 A (1,400 A peak) 1 ,000 V 1, 000 V
Vdc 0.15 to 1,400 V 1, 400 V 1 ,400 V
0.15 to
1,000 A 1,000 A
Vac+dc 1,000 V (1,400
(1,400 A peak) (1,400 A peak)
V peak)
Best accuracy 1% R + 3 cts 1 % R + 3 counts 1 % R + 3 counts
Frequency of V / I Yes / Yes
Resistance 60 kΩ 100 kΩ 100 kΩ
Audible continuity Adjustable from 1 Ω to 599 Ω Adjustable from 1 Ω to 999 Ω Adjustable from 1 Ω to 999 Ω
Diode test (semi-conductor junction) Yes Yes Yes
Adapter Yes Yes Yes
Single-phase and total three-phase
Yes Yes Yes
power values
°C: -60.0 to
temperature °C: -60.0 to +1,000.0 °C / °F: °C: -60.0 to +1,000.0 °C / 1,000.0 °C /
(K type) -76.0 to +1,832 °F °F: -76.0 to +1,832 °F °F: -76.0 to
+1,832 °F
active (W) Yes Yes Yes
reactive Var (Q1) Yes Yes Yes
apparent (VA) Yes Yes Yes
PF / DPF Yes / No Yes / - Yes / Yes Yes / - Yes / Yes
Harmonic analysis THDf / THDr Yes / Yes Yes / Yes Yes / Yes
Frequency analysis 25th order 25th order
Phase rotation (2-wire method) Yes Yes Yes
Functions
Overcurrent measurement Yes Yes Yes
Motor Inrush Yes Yes Yes
Load evolution (TrueInrush) Yes Yes Yes
Hold Yes Yes Yes
Min / MAX Yes Yes Yes
Peak+ / Peak- Yes Yes Yes Yes Yes
RELative ∆X Yes Yes Yes
Differential ∆X / X(%) Yes Yes Yes
Auto Power Off Yes Yes Yes
Data recording Yes Yes
Communication interface Bluetooth Bluetooth
Electrical safety according to IEC 61010 600V CAT IV 1, 000 V CAT IV - 1, 000 V CAT III 1 ,000 V CAT IV - 1 ,000 V CAT III
Power supply 1 x 9 V LF22 4 x 1.5 V AA 4 x 1.5 V AA
Dimensions / Weight 78 x 222 x 42 mm / 340 g 92 x 272 x 41 mm / 600 g 111 x 296 x 41 mm / 640 g
Warranty 3 years
Multifix bag
120 x245 x 60 mm (F200 series) x1 x1 x1 x1
120 x320 x 60 mm (F400/F600 series)
5
Multimeters
TRMS AC/DC and AC/DC/AC+DC
digital multimeters
600 V IP
CAT III 54
MTX 203 MTX 204
Reference MTX203-Z MTX204-Z
Display 6000 cts 6 000 cts
Acquisition TRMS AC/DC TRMS AC/DC/AC+DC
Measurement rate 2 meas./second
Autorange / Deactivatable Yes / Yes
Ranges 6 V / 60 V / 600 V
V DC Typical accuracy 0.2 % + 2 cts
Resolution 0.01 V to 1 V 0.001 V
Ranges 6 V / 60 V / 600 V / 750 V 0.6 to 750 V
V AC Resolution 0.001 V to 1V 0.5% + 4 cts
Bandwidth 1 kHz
VLow AC (low impedance Ranges 6 V / 60 V / 600 V / 750 V 0.5% + 4 cts
+ low-pass filter) Resolution 0.001 V to 1 V 0.001 V
Ranges
V AC + DC
Resolution 1% + 4 cts
600 µA / 6 mA / 60 mA /
Ranges 600 μA / 60 mA / 6 A
600 mA / 6 A / 10 A
A DC 0.1 µA to 0,01A 0.1 µA
Resolution
600 µA / 6 mA / 60 mA /
Ranges 600 μA / 60 mA / 6 A
A AC 600 mA / 6 A / 10 A
Resolution 0.1 µA to 0.01A 0.1μA
Ranges 600 μA / 60 mA / 6 A
A AC + DC
Resolution 0.1μA
Ranges 600 / 6 k / 60 k / 600 k / 6 M / 60 MW
Resistance
Resolution 0.1 W to 0.01 MW
Audible continuity Yes 600 Ω
Frequency and duty cycle 2Hz to 1kHz
Diode test Yes
Ranges No 2Hz to 1kHz
Hz
Resolution 0.001 Hz
Ranges 1nF/10nF/100nF/10µF/100µF/1mF/10mF/100mF
Capacitance
Resolution 0.001 nF to 10 µF
Ranges -55°C to +1200°C No
T°
Resolution 0.1 °C No
Hold Yes
Min / Max (100 ms) No Yes
Differential (DX) / Relative (DX/X%) measurement No Yes
Auto power-off Yes (deactivatable)
Power supply 2 x 1.5 V AA
Dimensions / weight 170 x 80 x 50 mm / 320g
6
ASYC IV digital
multimeters range
IP
67
MTX 3290 MTX 3291 *
Reference MTX3290 MTX3291
7
Multimeters
600 V IP
CAT IV 54
CA 5273 CA 5275 CA 5277
Reference P01196773 P01196775 P01196777
Display 2 x 6,000 counts, backlit
Bargraph 61 + 2 elements, bi-mode (full scale / central zero)
Acquisition TRMS AC /DC TRMS AC / DC / AC+DC
Measurement rate 5 measurements / second
Autorange / Deactivatable Yes / Yes
Automatic AC /DC detection Yes No
Ranges 600 mV / 6 V / 60 V / 600 V / 1,000 V 60 mV / 600 mV / 6 V / 60 V / 600 V / 1,000 V
V DC Typical accuracy 0.2 % + 2 cts 0.09 % + 2 cts
Resolution 0.1 mV to 1 V 0.01 mV to 1 V
Ranges 600 mV / 6 V / 60 V / 600 V / 1,000 V 60 mV / 600 mV / 6 V / 60 V / 600 V / 1,000 V
V AC Resolution 0.1 mV to 1 V 0.01 mV to 1 V
Bandwidth 40 Hz to 3 kHz 40 Hz to 10 kHz
VLow AC ((Low impedance Ranges 600 mV / 6 V / 60 V / 600 V / 1,000 V
+ Low-pass filter) Resolution 0.1 mV to 1 V
Ranges 60 mV / 600 mV / 6 V / 60 V / 600 V / 1,000 V
V AC + DC
Resolution 0.01 mV to 1 V
Ranges 6 A / 10 A (20 A / 30 s) 6,000 µA / 60 mA / 600 mA / 6 A / 10 A (20 A / 30 s)
A DC 0.001 A to 0.01 A 1 µA to 0.01 A
Resolution
Ionization current; 0.2 µA to 20.0 µA
Ranges 6 A / 10 A 6,000 µA / 60 mA / 600 mA / 6 A / 10 A (20 A / 30 s)
A AC
Resolution 0.001 A to 0.01 A 1 µA to 0.01 A
Ranges 6,000 µA / 60 mA / 600 mA / 6 A / 10 A (20 A / 30 s)
A AC + DC
Resolution 1 µA to 0.01 A
8
Digital multimeters NEW
IP
PRODUCTS
1000 V 600 V CEI
CAT III CAT IV 61010-2-033 67
Accessories
• raphical colour MTX 329X calibration software. . . . . . . . . . . . .
G > HX0059B
• Kit of 4 Ni-MH batteries. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . > HX0051B
• MTX 328X and MTX 329X external charger (4 batteries included). . > HX0053B
• MTX DMM digital multimeter transport kit. . . . . . . . . . . . . . . . . . > HX0052B
• Graphical colour DMM transport kit. . . . . . . . . . . . . . . . . . . . . . . > HX0052C
State at delivery
• CA 5292, CA 5292BT and CA 5293, CA 5293BT: delivered with a bag,
4 x NIMH 2400mAH 1.5V rechargeable batteries, 1 charger, 1 red 1.5m
straight/straight cable, 1 black straight/straight cable, 1 red CAT IV 1 kV
test probe, 1 black CAT IV 1kV test probe, 1 USB optical cable + SX-DMM
software, 1 user's manual on CD, 1 SCPI programming commands manual
and 1 start-up guide on paper
9
testers
Voltage Absence Tester Digital testers
(VAT)
1000 V IP
CAT IV 65
CA 773 600 V IP
Reference P01191773 CAT III 54
Display LEDs + Backlit digital display CA 757
Voltage detection Reference P01191757
State at delivery
• CA 773 delivered with 1 User's Manual in 5 languages, 2 x 1.5 V LR06/AA
Replacement parts for CA 757
batteries, 1 set of removable test probes Ø 2 mm with crystal safety cap, 1 CAT III/IV red/black test probes.................................... P01102152Z
probe protector, 1 Velcro strap. Ø 2 mm CAT II red/black test probes........................... P01102153Z
Ø 4 mm CAT II red/black test probes........................... P01102154Z
Velcro strap x 5............................................................ P01102113
Accessories & replacement parts for CA 773: 1.5 V LR3/AAA alkaline battery(x 1).............................. P01296032
Bag compatible with MultiFix accessories,
CAT IV test probes for VAT...................................................................... P01102123Z 120 x 200 x 60............................................................. P01298074
Ø 2 mm test probes for VAT.................................................................... P01102124Z MultiFix mounting accessory........................................ P01102100Z
Ø 4 mm test probes for VAT.................................................................... P01102125Z MA101-250 current sensor for CA 757........................ P01120591
Probe protector for VAT........................................................................... P01102126Z
IP2X CAT IV test probes for VAT.............................................................. P01102127Z
IP2X Ø 4 mm test probes for VAT............................................................ P01102128Z
MultiFix bag, 120 x 320 x 60 mm............................................................. P01298076
10
PHYSICAL MEASUREMENTS
Logger contact thermometers
> J, K, T, N, E, R and S
thermocouples (CA 1821 & CA 1822)
> Pt100 and Pt1000
resistive probes (CA 1823)
> Compact and magnetized
for fixed or portable use
> Can record up to 1 million points
State at delivery
Products delivered with carrying bag, batteries,
1 USB cable, 1 measurement report and quick
startup guide (complete user's manual and Data
Logger Transfer software available from the
Chauvin Arnoux website)
Automatic
Data Logger report
generation
Transfer,
the software Exportable
in Word
for analysing format
This simplifies editing
your data and archiving.
11
PHYSICAL MEASUREMENTS
Thermo-hygrometers CO2 ,Temperature and Humidity Logger
CA 1246
Reference P01654246
Relative Humidity range 3.0 to 98.0 %RH
Relative Humidity 10 to 90 %RH: ± (2 %RH ± 1 ct)
accuracy outside that range: ± (4 %RH ± 1 ct)
Temperature range - 10.0 to +60.0°C
10 to 40°C: ± (0.5°C ± 1 ct)
Temperature outside that range: ± (0.032 x (T-25) ± 1 ct) /
accuracy T= temperature in °C
Dew point range and Dew point: - 20.0 to +60.0 °Ctd
accuracy Accuracy: 1.5°C CA 1510 CA 1510 black
Functions Min., Max., HOLD, Alarms Reference P01651011 P01651010
Manual start/stop on the product
Recording Programmed recording Recording intervals Customizable from 1 minute to 2 hours
Visual alert when threshold definable Storage More than 1 million points
via Data Logger Transfer is overrun
Alarms Recording can be triggered Buzzer and units Yes / °C or °F
on the alarm threshold Backlighting Yes
1,000 hrs (portable mode) / 3 years when recording / Hold / Min Max
Battery life (measurements every 15 minutes) Dimensions / Weight 125 x 65.5 x 32 mm / 190 g with batteries
Ingress protection IP54 Batteries: 2 x 1.5V LR6
or rechargeable battery
Casing equipped with a magnet, a wall-mount
Power supply Mains connection possible
Mounting system and a slot for suspending the product. with mains adapter/
Compatible with the Multifix accessory. micro USB supplied as standard
Dimensions / weight 187 x 72 x 32 mm / 260 g
2 possible communication modes:
Bluetooth wireless link and USB link.
Interfaces The product is then recognized
as a USB key for simple file transfers
12
Thermo-anemometers Luxmeters
CA 1227 CA 1110
Reference P01654227 Reference P01654110
Air speed/ 0.1 to 200,000 lx
Vane with optical detection Measurement range 0.01 to 18,580 fc
flow-rate sensor
Air speed range 0.25 m/s to 35.0 m/s (49.0 to 6890.0 fpm) Accuracy in standard mode
Air speed accuracy ± 3 % of reading ± 4 cts Incandescent lamp ± 3 % of reading
Air flow-rate range 0 to 2,999 m3/h LED ± 6 % of reading (3,000 K and 6,000 K)
13
ELECTROCHEMISTRY
IP
CA 10001 watertight pH/temperature tester 65 pH Redox °C °F
pH Temperature
> Automatic, extremely easy calibration at
Reference P01710015 3 points: saves time!
Measurement range 0.00 – 14.00 pH 0,0 – 60.0 °C > Detection of temperature-compensated pH values (ATC)
32.0 – 140.0 °F
Resolution 0.01 pH 0.1 °C / 0.1 °F State at delivery
Error ± 0.1 pH ± 1 °C / ± 2 °F Two CR2032 3V batteries, one electrode storage flask, one
multilingual User's Manual, one verification certificate.
Calibration Automatic; 1, 2 or 3 points ; stored buffers
Interchangeable electrode No
Accessories
Power supply /Life span 2 x CR2032 3V batteries / >100 hours
pH 4.01 buffer solution (NIST)*, 125 mL..............................P01700106
Auto power-off After 20 min without activity
pH 7.00 buffer solution (NIST)*, 125 mL..............................P01700107
Dimensions/weight 227 x 36 x 20 mm / 65 g
pH 10.01 buffer solution (NIST)*, 125 mL............................P01700109
Operating range / 0 to +50°C, max. Relative Set of 3 plastic beakers.......................................................P01710056
80%
Environment Storage range -10 to +50°C, max. Relative * Delivered with a quality certificate guaranteeing compliance with the
Humidity 90% NIST (National Institute of Standards and Technology) and DIN 19266
Warranty 1 year standards.
CA 10141
Reference P01710020
Measurement range (instr. alone) 0,050 µS/cm to 500,0 mS/cm
Resolution (R) 0.001 to 0.1 (depending on range)
Intrinsic uncertainty (instr. alone) ± 0.5% ± R
TDS
Measurement range (instr. alone) 0.001 mg/l to 499,9 g/l
Resolution (R) 0.001 to 0.1 (depending on range)
Intrinsic uncertainty (instr. alone) ± 0.5% ± R
Resistivity
Measurement range (instr.alone) 2.000 Ω.cm to 19.99 MΩ.cm
CA 10141 Resolution (R)
Intrinsic uncertainty (instr. alone)
0.001 to 0.01 (depending on range)
± 0.5% ± R
conductivity meter Salinity
Measurement range (instr. alone) 2.0 to 42.0 psu
Resolution (R) 0.1
Measurement parameters: Intrinsic uncertainty (instr. alone) ± 0.5% ± R
Temperature
conductivity, TDS Measurement range (instr. alone) - 10 to + 120°C (14 to 248°F)
(Total Dissolved Solids), Resolution (R) 0.1 °C (0.1°F)
resistivity, salinity, Intrinsic uncertainty (instr. alone) < 0.4°C (<0.7°F)
Available reference temperature 20/25 °C (68/77°F)
temperature (°C or °F) 1 point, 6 predefined conductivity reference
Calibration standards (user-modifiable); Possibility of
resetting to default calibration
IP
TDS
Temperature compensation
67
Conductivity Resistivity
Automatic (ATC) or manual (MTC) linear,
Temperature compensation mode non-linear
Conductivity sensor
Salinity
°C °F Type
XCP4ST1 (supplied), 4-pole conductivity
sensor with built-in temperature sensor
(Pt 1000)
Connector 8-pin DIN, 1 m cable
Data storage
CA 10141 state at delivery Memory > 100,000 measurements
CA 10141 delivered in site-proof hard case with: 1 x 4-pole conductivity 8-pin DIN (adapters for BNC, S7 and Jack
Sensor input
cell with built-in XCP4ST1 temperature probe, 4 x 1.5 V LR06 batteries, available as an option)
1 protective sheath mounted on the instrument, 1 x 1408 μS/cm Communication interface Type B micro-USB (USB device), 12 Mbit/s
conductivity solution, 1 plastic beaker,1 USB – micro USB cable, 1 Power supply
wrist strap Number – Type 4 x 1.5 V AA or LR06 alkaline batteries
Auto power-off After 3, 10 or 15 min without use (adjustable)
14
CA 10101 watertight portable pH-meter
The CA 10101's extra-wide, multi-display LCD screen makes it particularly
comfortable to read and it offers storage on request of more than 100,000 time/
date-stamped measurements (PC software included)
IP
67
SPECIFICATIONS Measurement parameters
Reference P01710010
pH -2.00 to 16.00 pH*
Measurement range Redox ±199.9 mV -1999 to -200 and +200 to +1999 mV
(instrument only)
Temperature -10.0 to +120.0°C / 14.0 to 248.0°F
pH 0.01 pH
Resolution (R) Redox 0.1 mV 1 mV
Temperature 0.1 °C / 0.1 °F
Intrinsic uncertainty of the pH ± 0.01 pH ± r
instrument (without the Redox ± 0.1 mV ± r ± 1 mV ± r
electrode) Temperature < 0.4°C / < 0.7°F
pH Automatic, up to 3 points, 3 groups of predefined reference solutions (modifiable)
Calibration
Redox Automatic, 1 point, two predefined reference solution values (modifiable)
Temperature compensation Automatic (ATC) or manual (MTC), -10°C to +120°C (14°F to 248°F)
XRGST1 (supplied): pH combination electrode with built-in temperature
pH sensor (Pt1000) and 8-pin DIN connector
Electrode
XRPTST1 (option): ORP combination electrode with built-in temperature
Redox sensor (Pt1000) and 8-pin DIN connector
Date and time Yes
Data storage
Data storage > 100,000 measurements
State at delivery
1 CA 10101 pH-meter delivered in a site-proof case with 1 XRGST1 pH combination electrode with built-in temperature sensor, 4 AA or LR6
alkaline batteries, 1 protective sheath mounted on the instrument, 2 ready-to-use buffer solutions (compliant with NIST/DIN) with pH 4.01
and 7.00, 2 plastic beakers, 1 USB - micro USB cable, 1 wrist strap, quick start-up guides (one per language).
15
THERMOGRAPHY
CA 1950 and CA 1954 thermal cameras,
the perfect match between performance and technology!
Strengths
> Exceptional battery life
> Rapidity: startup in 3 seconds
> An emissivity table which can be enhanced as
required
> Possibility of renaming the images and
thermograms per site
> Recording and storage of the configurations
according to the applications
> Voice annotations to record your comments
directly on the image
> Connectivity with current clamps and
multimeters: all the measurements necessary
simultaneously
> Bluetooth™ communication
> CamReport analysis and report creation software
> Built-in slide-down protective cover
APPLICATIONS
Detect any thermal faults quickly & simply!
Mechanical inspections
Electrical inspections Thermal inspections Radiator inspections
Construction
16
CA 1950 CA 1954
Reference P01651901 P01651904
Detector 80 x 80 120 x 160
Sensitivity (NETD) 80 mK @ 30 °C (0.08 °C @ 30 °C)
Temperature range -20 °C to +250 °C
Accuracy ±2 °C or ±2 % of reading
Field of view 20° x 20° 28 ° x 38 °
IFOV (spatial resolution) 4.4 mrad 4.1 mrad
Focusing Fixed
Real image Yes
Measurement tools 1 manual cursor, automatic Min-Max detection, temperature profile, isotherm
State at delivery
CA 1950 and CA 1954 delivered in site-proof case with 4 NiMH batteries
and 1 battery charger, 1 micro SD HD card, 1 USB cable, 1 Bluetooth
earpiece, the CAmReport software on CD ROM, User's Manuals and a
measurement report.
THE BEST
SOFTWARINEG
CAmReport software included FOR ANALYS !
THERMOGRAMS
CA The CAmReport software is supplied as standard
1950 with the CA 1950 & CA 1954 cameras.
It offers all the functions needed for reliable analysis of your measurement results:
CA
1954 Strengths
• Cursors (automatic display of the temperature at the chosen point)
• Thermal profile (automatic display of the Min/Max/Avg temperatures
of the line)
PDF • A square or circle for zone analysis
• Results tables quickly and automatically display all the
information/analytical tools for the thermogram
• Polygons and polylines for more precise analysis of certain zones
in the thermogram
• User-enhanceable emissivity table supplied as standard
Reports are created automatically using the
• Ready-to-use, customizable report templates various templates available
17
ELECTRICAL TESTING AND SAFETY
CA 6528 digital insulation tester
CA 6528
Reference P01140838
Voltage
Measurement range / resolution 1-700V / 1V
Accuracy / input impedance ±1.2% reading ± 1pt in AC+DC ; ±1% reading ± 1 ct in DC / 25 MΩ
Operating frequency DC; 30-440 Hz
Insulation
Test voltage 250-500-1000 V
Range at maximum test voltage 11 GΩ
Measurement range 250 V : 50 kΩ - 4,2 GΩ / 500 V : 100 kΩ - 4.2 GΩ / 1,000 V : 200 kΩ - 11 GΩ
50 kΩ - 3.999 / 1kΩ; (0.2)1 3.6-39.99 MΩ / 10 kΩ;
Measurement range / resolution 36-399.9 MΩ / 100 kΩ; 360-4,200 MΩ / 1 MΩ; (1kV) 3.6 - 11.00 GΩ / 10 MΩ
0.05-399.9 MΩ: ±1.5% reading ± 10 cts; 360 -4,200 MΩ: ±4% reading ± 10pt; ±4%
Accuracy reading ± 5 cts (at 1,000V); 3.6-11 GΩ: ±10% reading ± 10 cts
Timer (min:s) 10 s to 39 min 59 s
Alarms 1 threshold / test voltage
Continuity
Measurement range 0.02 Ω - 40 Ω (200 mA)
Accuracy / Open-circuit voltage ±1.2% reading ±3 cts / 6 VDC < U < 9 VDC
Measurement current ≥ 200 mA (up to 2 Ω)
Continuity thresholds (fast beep) 2Ω/1Ω
Cable compensation up to 5 Ω
Resistance NEW
Measurement range / resolution
Accuracy
1 -399.9 Ω / 0.1 Ω -360-2 999 Ω / 1 Ω - 3.60-39.99 kΩ / 10 Ω - 36.0-420.0 kΩ / 100Ω
±1.2% reading ± 3 cts PRODUCT*
General specifications
Display 2 x 4,000 cts
Power supply / Auto power-off 6 x LR 6 or AA batteries / 10 min, deactivatable
1,000 measurements: at 1 MΩ @ 1 kV (5 s ON / 25 s OFF) ;
1000 V 600 V
Battery life >3,000 continuity measurements (5 s ON / 25 s OFF) at 1 Ω CAT III CAT IV
Dimensions / weight / IP rating 218 x 95 x 63 mm / 760 g / IP 40
EMC / Electrical safety IEC 61326-1 / IEC 61010-1. IEC 61010-2-030 and IEC 61010-2-034 / 600V CAT IV
Compliance with standards IEC 61557 parts 1. 2. 4 and 10 IP
40
State at delivery Accessories and replacement parts
CA 6528 delivered in a hands-free bag containing: 2 safety leads - 1 red
Set of red and black 1.5 m safety leads......................................P01295289Z
*Available soon
and 1 black, 1 red crocodile clip, 1 black test probe, 1 protective sheath
Red + black crocodile clips.........................................................P01295457Z
mounted on the instrument, 6 x LR6 or AA batteries, 1 safety datasheet,
Red + black test probes..............................................................P01295454Z
1 quick start-up guide, 1 verification certificate
Continuity rod..............................................................................P01102084A
18
CA 6422 and CA 6424
Earth/ground testers
600 V IP
CAT IV 65
IEC
61557
NEW
P DUCTS*
R O
CA 6422 CA 6424
Reference P01127012 P01127014
Voltage (UHE)
Range - 0.1-600V
Resolution - 0.1V
Accuracy - ± ( 1% reading + 1 ct)
2P resistance
Range 0.05-99.99 Ω / 80.0-999.9 Ω / 0.800-9.999 kΩ / 8.00-50.00 kΩ
Resolution 0.01 Ω / 1 Ω / 10 Ω / 100 Ω
Accuracy ± ( 2% reading + 10 ct) / ± ( 2% reading + 2 cts) / ± ( 2% reading + 1 ct) / ± ( 2% reading + 1 ct)
Cable compensation - up to 5 Ω
3P earth/ground resistance
Range 0.5 Ω - 2.000 kΩ 0.5 Ω - 50.00 kΩ
Resolution 0.01 Ω / 0.1 Ω / 1 Ω 0.01 Ω / 0.1 Ω / 1 Ω/ 10 Ω
Accuracy ±(1% reading + 10 cts) / ±(1% reading + 2 cts) / ±(1% reading + 1 ct)
Measurement frequency 128 Hz or 256 Hz
Open-circuit voltage ± 10 V peak
Measurement mode One-shot or permanent
Data storage RE registers @ 62%; RE @ 52%; RE @ 72%
Calculation of the average - calculation of the average and % deviation in relation to the average
RH stake resistance measurement
Range - 0.05-9.999 kΩ / 8 - 49.99 kΩ
Resolution - 1 Ω / 10 Ω
Accuracy - ±(10% reading + 1 ct)
USE voltage measurement No
Range - 0.10 - 99.99 VAC / 80.0 - 600 VAC
Resolution - 0.01 V / 0.1 V
Accuracy - ±(2% reading + 2 cts) ±(2% reading + 2 cts)
Current resistance (via optional G72 clamp)
Range 0.5 – 999.9 mA / 0.800-9.999 A / 8.00-60.00 A
Resolution 0.1 / 1 / 10 mA
Accuracy ±(1% reading + 4 cts) / ±(1% reading + 2 cts)
Display 206-segment backlit Custom LCD
Measurement mode R 2P (Ω), R 3P (Ω) V, I, R 2P (Ω), R 3P (Ω)
Power supply 6 x LR 6 or AA batteries 6 NiMH rechargeable batteries, charging time approx. 6 hrs
Charger - Internal via mains / USB adapter supplied
Automatic power-off - Deactivatable
Battery life > 2000 x 3P measurements at 100 Ω > 1,500 3P earth measurements at 100 Ω
Dimensions / weight 223 x 126 x 70 mm / 1 kg
Environment Operation: -10 to +50°C / Storage: -40 to + 70 °C (without batteries or rechargeable batteries)
Protection Up to 600 V on any of the 3 input terminals
*Available soon
19
Testing and electrical safety
Installation tester
Test the electrical safety of your installations
Measurement current: 12 mA • 1 to 19 Ω • 20 to 39 Ω
40 to 2,000 Ω / 1 Ω / ±(2 cts) • ±(15 % R + 3 cts) •
NO TRIP mode (Zs (L-PE) only)
± (5 % R + 2 cts)
20
Installation testers
600 V IP
CAT III 53
CA 6116N CA 6117
BONDING / RESISTANCE
I > 200 mA / 39.99 Ω / 0.01 Ω / ± (1.5 % of reading + 2 cts)
I rated / Range / Resolution 12 mA / 39.99 Ω and 399.9 Ω / 0.01 and 0.1 Ω /± (1.5 % of reading + 5 cts) with buzzer
Range/ Resolution / Accuracy 4 kΩ / 1 Ω / ±(1.5 % of reading + 5 cts) • 40 kΩ - 400 kΩ / 10 Ω - 100 Ω / ±(1.5 % of reading + 2 cts)
ISOLATION
Rated voltage Utest : 50 /100 / 250 / 500 / 1,000 V DC
Range / Basic accuracy 0.01 MΩ to 2 GΩ / 10 kΩ to 1 MΩ / ±(5 % of reading + 3 cts)
Short-circuit current ≤ 3 mA
EARTH
3P earth 0.50 Ω to 40 Ω / 0.01 Ω / ±(2 % of reading + 10 cts) • 40 Ω to 15 kΩ / 0.1 Ω to 1 Ω / ±(2 % of reading + 2 cts )
Range / Resolution / Accuracy 15 kΩ to 40 kΩ / 10 Ω / ±(10 % of reading + 2 cts )
Others Resistance measurement of RH & RS auxiliary stakes (up to 40 kΩ)
Ufk Compliant with SEV 3569
1P SELECTIVE EARTH
0.50 Ω to 39.99 Ω - 40 Ω to 399.9 Ω / 0.01 Ω – 0.1 Ω / ±(10 % of reading + 10 cts) (ISel via clamp)
Range / Resolution / Accuracy
LOOP IMPEDANCE (Zs (L-PE) and Zi (L-N or L-L) – 1P LIVE EARTH
LIVE EARTH
90 to 500 V / 15.8 to 17.5 Hz - 45 to 65 Hz
Installation voltage / frequency
High current TRIP mode Max. test current: 7.5 A
Zs (L-PE) & Zi (L-N or L-L) (0.050) 0.100 Ω to 0.5 Ω / 0.001 Ω / ± (10 % of reading + 20 cts) • 0.5 Ω to 3.999 Ω / 0.001 Ω / ± (5% of reading + 20 cts)
Range / Resolution / Accuracy 3.999 to 39.99 Ω / 0.01 Ω / ± (5 % of reading + 2 cts) • 40.0 Ω to 399.99 Ω / 0.1 Ω / ± (5% of reading + 2 cts)
NO TRIP mode Test current: 6 mA – 9 mA – 12 mA (as required) • 0.20 Ω to 0.99 Ω / 0.01 Ω / ± (15 % of reading + 10 cts)
1.00 to 1.99 Ω / 0.01 Ω / ± (15 % of reading + 3 cts) • 2.00 to 39.99 Ω / 0.01Ω / ± (10 % of reading + 3 cts)
(Zs (L-PE) only) 40.00 Ω to 399.9 Ω / 0.1 Ω / ± (5 % of reading + 2 cts) • 400 to 3,999 Ω / 1 Ω / ± (5 % of reading + 2 cts)
Calculation of short-circuit current Ik
Fault and short-circuit current: 0.1 A to 20 kA
(PFC (Zs)) , I Sc PSCC (Zi)
Table of integrated fuses Yes
Voltage drop ∆V%(Zi) -40 % to +40 %
Others Measurement of the resistive and inductive components of the impedances Zs and Zi
TYPE AC and A RCDs
Installation voltage / Frequency 90 V to 500 V / 15.8 Hz to 17.5 Hz and 45 Hz to 65 Hz
6/30/100/300/500/650/1000 mA (90 V - 280 V) or variable 6/10/30/100/300/500 mA (280 V - 550 V) or variable
I∆n
Ramp and pulse test
No Trip test At ½ I∆n – Duration: 1,000 ms or 2,000 ms
Ramp mode 0.2 to 0.5 x I∆n (Uf) / 0.3 x I∆n to 1.06 x I∆n in increments of 3.3 % x I∆n
Tripping time measurement: Range / 0.2 to 0.5 x I∆n (Uf) / 0.5 x I∆n / 2 x I∆n (selective) / 5 x I∆n
Resolution / Accuracy Pulse: 0 to 500 ms / 0.1 and 1 ms / 2 ms, Ramp mode (10) to 200 ms / 0.1 ms / 2 ms
TYPE B RCDs
Installation voltage / frequency 90 V to 280 V / 15.8 Hz to 17.5 Hz and 45 Hz to 65 Hz
I∆n: ramp / pulse 2 x I∆n 6/10/30/100/300/500 mA
6/10/30/100 mA with 4 IΔn pulse
pulse 4 x I∆n Duration: 150 ms in 4 x I∆n or 300 ms with 2 x I∆n
Test in ramp mode 0.2 x I∆n to 2.2 x I∆n
Tripping time: 2 x I∆n I∆N ≤ 200 mA : 2.2 x 2 x I∆n
I∆N > 200 mA : 1.1 x 2 x I∆n
4 x I∆n I∆N ≤ 100 mA : 2.2 x 4 I∆N
OTHER MEASUREMENTS
Current via C177A clamp 5.0 mA to 199.9 A (C177A)
Current via MN77 clamp (1 mA*) 5.0 mA to 19.99 A
Voltage 0 to 550 VAC/DC / DC and 15.8 to 450 Hz
Frequency 15.8 to 500 Hz
Phase sequence 20 to 500 VAC
Active power 0 to 110 kW single--phase - 0 to 330 kW three-phase - Simultaneous display of voltage and current waveforms
Harmonics Voltage and current / up to 50th order / THD-F /THD-R
GENERAL SPECIFICATIONS
Display Large 5.7” backlit colour graphical LCD screen, 320 x 240 points
Storage/Communication 1,000 tests / via USB for data transfer and report creation
Power supply / Battery life Lithium-ion rechargeable battery rated 10.8 V 5.8 AH / up to 30 hours
Dimensions / weight 280 x 190 x 128 mm / 2.2 kg
Ingress protection / EMC IP 53 / IK04 / IEC 61326-1
Electrical safety IEC 61010 -1 – 600 V CAT III – 300 V CAT IV – IEC 61557
* if a voltage is connected to the instrument
State at delivery
• CA 6116N • CA 6117:
1 tester delivered with a carrying bag, 1 type-2 mains power pack / charger,
1 Li-Ion battery pack, 1 USB A/B cable 1.50 m long, 1.80 m, with ferrite,
References
1 three-point cable - 3 safety leads (red, blue and green), 3 test probes,
Ø 4mm (red, blue and green), 3 crocodile clips (red, blue and green), • CA 6116N EURO Contrôleur...........P01145455 X*
2 elbowed-straight safety leads, 3 m (red and black), 1 three-point Euro mains • CA 6117 EURO Contrôleur..............P01145460 X*
cable, 1 x 2P EURO mains cable, 1 remote-control probe, 1 wrist strap,
1 scratch-proof film mounted on the instrument, 1 x 4-point hands-free strap,
* version GB : X = A, version IT : X = B,
ICT data export software on CD-ROM, 6 operating manuals on CD
version CH : X = C, version US : X = D
(one per language), 1 safety datasheet in 20 languages.
21
Electrical Testing and Safety
Insulation and Continuity Testers
Discover our new range:
> Test voltage from 10 V
to 1,000 V / 200 GΩ
> Manual, Lock, Timer and
PI / DAR Ratios modes
> Visual Pass / Fail: red / green
> 200 mA / 20 mA continuity with
active protection without fuses
> Measurement of V (TRMS & DC),
F, Ω, kΩ, C and cable length
> ΔRel mode & configurable alarms
> Storage of measurements in memory
CA 6522, CA 6524,
CA 6536 CA 6532 CA 6534
CA 6526
"Special & ESD" "Telecommunications" "Industrial Maintenance" "Electronics"
applications applications applications applications
With a variable test voltage • Insulation tests at 50 V Periodic insulation tests on Thanks to its wide test-voltage
from 10 V to 100 V in 1 V or 100 V installations and equipment help range from 10 V to 500 V,
increments, this model is • Specific functions: to prevent incidents by setting this model covers the specific
intended for special measurement of resistance, up preventive maintenance requirements of the electronics
applications in sectors such as capacitance, leakage designed to detect ageing and industries, for both low-current
avionics, space and defence, current and AC voltage. premature deterioration of their applications and power stages.
which often require • Measurement of insulation characteristics: Its measurement range is from
a low test voltage and the difference in resistance • Measurement of insulation 2 kΩ to 50 GΩ.
strict adherence to between 2 wires in a pair over a programmed duration
the programmed value. by using the ΔREL function. • Alarms and Pass/Fail indicator
With appropriate electrodes, • Display of the length of light (CA 6526)
the 10 V and 100 V test the line being tested, • PI and DAR ratios to determine
voltages can also be used thanks to programming the quality of the insulation,
for electrostatic discharge of the linear capacitance with the advantage of not
applications. in nF/km. being significantly influenced
by the temperature
• Storage in memory to compare
the measurement histories
®
Remote control probe software
The remote control probe is an accessory specially developed ®
software, with its Megohmmeter Transfer
to make your insulation tests in the field simpler and quicker. module, automatically recognizes the instrument when it is
• Insulation measurement can be triggered with connected to the PC and opens the corresponding menu.
a single press on the probe’s yellow button. This tree-structure menu offers users direct access to the data
• Equipped with a torch function, this probe effectively recorded in the instrument and its configuration.
lights the point of measurement. The other functions available are:
• Thanks to the tester’s backlit screen, • Activation of remote tests
the measurement results are visible • Real-time display
at all times, including in places with • DAR and PI references
poor lighting. • Graphical plot of the tests
• Generation of measurement reports
Reference P01102092A Reference P01102095
22
CA 6522 CA 6524 CA 6526 CA 6532 CA 6534 CA 6536
P01140836 /
Reference P01140822 P01140824 P01140826 P01140832 P01140834 P01299974
Application Industrial Maintenance Telecom Electronics / ESD Specials & ESD / Kit ESD
Voltage
Measurement range / Resolution 0.3V - 399.9 V / 0.1 V; 400V-700V / 1V
Accuracy / Input impedance +/- (3% + 2cts) / 400 kΩ
Operating frequency DC; 15.3 - 800 Hz
Frequency
Measurement range / Resolution / 15.3 Hz- 399.9 Hz / 0.1 Hz / +/- (0.5% + 2cts) ;
Accuracy 400-800 Hz / 1 Hz / +/- (1% +1ct)
Insulation
10 - 25 - 100 - 250 10 to 100V in
Test voltage 250-500-1,000V 50 - 100 - 250 - 500 - 1 000 V 50 - 100 V
- 500 V 1V increments
Range at maximum test voltage 40 GΩ 200 GΩ 20 GΩ 50 GΩ 20 GΩ
Compliance with IEC 61557-2 standard 2 GΩ 2 GΩ 2 GΩ
Measurement range: 10 V 2 kΩ - 1 GΩ 2 kΩ - 2 GΩ
25 V 5 kΩ - 2 GΩ (UN/5) kΩ -
50 V 10 kΩ - 10 GΩ 10 kΩ - 10 GΩ (UN/5) GΩ
100 V 20 kΩ - 20 GΩ 20 kΩ - 20 GΩ 20 kΩ - 10 GΩ 20 kΩ - 20 GΩ
250 V 50 kΩ - 10 GΩ 50 kΩ - 50 GΩ 50 kΩ - 25 GΩ
500 V 100 kΩ - 20 GΩ 100 kΩ - 100 GΩ 100 kΩ - 50 GΩ
1,000 V 200 kΩ - 40 GΩ 200 kΩ - 200 GΩ
Variable test voltage 10 V to 100 V
10(1) - 999 kΩ and 1.000 - 3.999 MΩ / 1 kΩ; 4.00 - 39.99 MΩ / 10 kΩ; 40.0 - 399.9 MΩ / 100 kΩ;
Measurement range / resolution
400 - 3999 MΩ / 1 MΩ; 4.00 - 39.99 GΩ / 10 MΩ ; 40.0 - 200 GΩ / 100 MΩ
Accuracy ± (3 % + 2 cts)(2) ± (3 % + 2 cts)(3)
Test voltage (I < 1 mA) - 0 % + 20 % ± 0.5 V
Display of test voltage ± (3 % + 3 cts) ± (3 % + 3 cts)
Display of test current / resolution 0.01 μA - 39.99 μA / 10 nA ; 40.0 - 399.9 μA / 100 nA; 0.400 - 2.000 mA/ 1 μA
Accuracy of test current ± (10 % + 3 cts)
PI/DAR ratios 10 mn / 1 mn - 1 mn / 30 s
Timer (min:s) 0:00 - 39:59
Discharge time (at 25 V) < 2 s/µF
Alarms 2 fixed thresholds + 1 programmable threshold
Continuity
Range for continuity measure- 0.00 Ω – 10.00 Ω
0.00 Ω – 10.00 Ω (200 mA); 0.0 – 100.0 Ω (20 mA)
ment (200 mA)
Accuracy / Open-circuit voltage ± (2 % + 2 cts) / ≥ 6 V
Measurement current -0%+4%
Continuity thresholds (quick beep) 2 Ω fixed 2 Ω, 1 Ω,2Ω, 1Ω, programmable threshold
Compensation of cables up to 9.99 Ω
Resistance
Measurement range 0 - 3999 Ω / 1 Ω; 4.00 kΩ – 39.99 kΩ / 10 Ω / ± (3 % + 2 cts)
/ Resolution / Accuracy 40.0 kΩ – 399.9 kΩ / 100 Ω; 400 kΩ - 1000 kΩ / 1 kΩ / ± (3 % + 2 cts)
Capacitance
0.1 nF - 399.9 nF / 0.1 nF
Measurement range / resolution 400 nF - 3999 nF / 1 nF
4.00 µF - 10.0 µF / 10 nF
Accuracy ± (3 % + 2 cts)
Line length 0 - 100 km
General specifications
Display 2 x 4,000 cts + logarithmic bargraph
Storage 300 measurements 1,300 measurements
Communication Bluetooth® Classe II
Power supply / Automatic shutdown 6 x LR6(AA) batteries / 5 min , deactivatable
Battery life 1,500/2,500/6,000 measurements (4): UN x 1 kΩ @ UN (5s ON / 55 s OFF); 3,000 continuity measurements (5s ON / 55 s OFF)
Dimensions (hxwxd) / Weight / IP rating 211 x 108 x 60 mm / 850 g / IP 54 / IK 04
EMC / Electrical safety IEC 61326-1 / IEC 61010-1 and IEC 61010-2-030, 600V CAT IV
Compliance with standards IEC 61557 parts 1, 2, 4 and 10
(1) : 2 kΩ for CA 6532 - CA 6534 - CA 6536 – (2): to be added: 10 V: 1% per 0.1 GΩ ; 25 V: 0.4% per 0.1GΩ ; 50 V: 2% per GΩ; 100 V: 1% per GΩ; 250 V : 0.4% per GΩ; 500 V: 0.2% per GΩ;
1,000 V: 0.1% per GΩ – (3): 10%/UN is added per 100 MΩ – (4): depending on the model.
Accessories and Continuity rod . . . . . . . . . . . . . . . . . . . . . . . . P01102084A 2 wire grips (red and black) . . . . . . . . . . . . . P01102053Z
23
Electrical Testing and Safety
600 V
CAT IV
Insulation
testers
Insulation 50 / 100 / 250 / 500 / 1,000 VDC 500/1,000/ 2,500 / 5,000 VDC + variable from 50 V to 5,100 VDC (10 or 100 V increments)
Range 2 kΩ to 4 TΩ 10 kΩ to 10 TΩ
Alarms yes
Chronometer yes
Backlighting yes
Dataview® Dataview®
PC software no no no
(option) (option)
24
Digital insulation
testers
> Wide measurement range
from 10 kΩ to 30 TΩ
- 5 mA charging current
- Large backlit LCD screen with
digital display, bargraph and
R(t)+u(t), i(t) and i(u) graphs
- Automatic calculation of
DAR / PI / DD / ΔR (ppm/V) ratios
> 3 filters to optimize
measurement stability
IP
54 CA 6550 CA 6555
Reference P01139705 P01139706
Voltage 10 kV 15 KV
25
Electrical Testing and Safety
Earth and resistivity
testers
State at delivery
Earth and resistivity kit (100 m kit)
•C
A 6460 : delivered with 8 x 1.5 V LR6 batteries and 1 operating
Ref.: P01102024
manual in 5 languages
Compartment bag with space for tester
•C
A 6462: delivered with 1 mains lead for recharging and containing: 4 "T"-shaped rods, 4 coils of
1 operating manual in 5 languages cable (100 m red, 100 m blue, 100m green,
• CA 6470N: delivered with 1 external mains charger, data export 30 m black), 1 green 10 m cable reeler,
software + optical / U SB communication lead, 5 operating manuals 1 mallet, 5 x Ø 4 mm lug/banana plug adapters
(one per language) on C D-ROM, 5 simplified operating manuals,
Standard 3P-method earth kit
each in a different language, 5 descriptive labels, each in a
different language 50 m kit Ref.: P01102021
• CA 6471: delivered with 1 external mains charger, data export Carrying case containing: 2 “T”-shaped rods, 2 coils of cable
software + optical / USB communication lead, 2 C182 clamps (50 m red, 50 m blue), 1 green 10 m cable reeler, 1 mallet,
with 2 safety leads, 5 operating manuals (one per language) 5 x Ø 4 mm lug/banana plug adapters
on CD-ROM, 5 simplified operating manuals, each in a different 100 m kit Ref.: P01102022
language, 5 descriptive labels, each in a different language, Carrying case containing: 2 “T”-shaped rods, 2 coils of cable
1 carrying bag. (100 m red, 100 m blue), 1 green 10 m cable reeler, 1 mallet,
5 x Ø 4 mm lug/banana plug adapters
Accessories
CA 6471 For the CA 6471 and CA 6470N
• MN82 clamp (diam. 20mm) • Dataview report generation software . . . . . . . . . . . . . . . . . . P01102095
(delivered with 1 x 2m cable for ES terminal connection) . . P01120452 • Adapter for recharging on vehicle cigarette lighter . . . . . . . P01102036
• C182 clamp (diam. 20mm) • Optical / RS communication cable . . . . . . . . . . . . . . . . . . . P01295252
(delivered with 1 x 2m cable for ES terminal connection) . . P01120333 • GB mains power cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . P01295253
• Set of 10 fuses - F 0.63 A – 250 V – 5x20 mm – 1.5 kA . . . AT0094
• Adapter for charging battery from the mains . . . . . . . . . . . . P01102035
• Battery pack . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . P01296021
• Optical / USB communication cable . . . . . . . . . . . . . . . . . . HX0056-Z
26
Protective earth cable Current
injection
rod RH
Auxiliary electrode
Earth and resistivity tester with adapter
for pylon earth measurements
H
ES
High-voltage E
C.A 6472
lines
Reference 3
potential 4
C.A 6474
State at delivery
• CA 6472: delivered with mains adapter + 2P mains plug for battery recharging on mains, data export
Earth and
software + optical / USB communication cable, 2 x C182 clamps, 2 safety leads, 5 operating manuals (one
per language) on CD-ROM, 5 simplified operating manuals (one per language), 5 identification labels (one Resistivity
per language), 1 bag. Kit (100m Kit)
• CA 6474: delivered with an accessories bag containing 1 connection cable, 6 BNC/BNC cables 15 m see page 16
long, 4 flexible current sensors (AmpFlex®) 5 m long, 1 set of 12 identification rings for AmpFlex®, 2 cables
(5 m green, 5 m black) with safety plugs on winder, 5 spade lug/Ø 4 mm banana plug adapters, 3 clamps,
1 calibration loop, 5 operating manuals and 5 specification labels, each in a different language.
Accessories
CA 6472 • et of 12 AmpFlex® identification rings . . . . . . . . . . . . . . . . .
S P01102045
• MN82 clamp (diam. 20mm) • Set of 3 adjustable clamps . . . . . . . . . . . . . . . . . . . . . . . . . . P01102046
(delivered with 1 x 2m cable for ES terminal connection) . . . P01120452 • 5 m green cable for CA 6474 (E terminal connection). . . . . . P01295291
• C182 clamp (diam. 20mm) • 5 m black cable for CA 6474 (ES terminal connection) . . . . . P01295292
(delivered with 1 x 2m cable for ES terminal connection) . . . P01120333 • Spade lug/Ø 4 mm banana plug adapters . . . . . . . . . . . . . . P01102028
• Calibration loop . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . P01295294
• AmpFlex® flexible current sensors:
For the CA 6472 and CA 6474 : other lengths available on request
•C A 6472 – CA 6474 connection cable . . . . . . . . . . . . . . . . . . P01295271
• 15 m BNC / BNC cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . P01295272
• 5 m AmpFlex® flexible current sensor for CA 6474. . . . . . . . P01120550
27
Electrical testing and safety
600 V 100 V
CAT IV CAT IV
Earth clamps IP 150 V
and loop testers 40 CAT III
CA 6416 CA 6417 CA 6418
Reference P01122015 P01122016 P01122018
Discover the CA 6418 Specifications
oblong-headed earth Loop ohmmeter Measurement ranges (Ω) / Resolution (Ω) / Accuracy
clamp Display on 1,500 counts Display on 1,200 counts
0.010 to 0.099 / 0.001
0.010 to 0.099 / 0.001 / ±1.5 % ±0.01 Ω ±1.5% R* ±0.01 Ω
0.10 to 0.99 / 0.01 /
0.10 to 0.99 / 0.01 / ±1.5 % ±2 r ±1.5 % R ±2 r
1.0 to 49.9 / 0.1 / ±1.5 % ±r 1.0 to 49.9 / 0.1 / ±1.5 % R ±2r
50.0 to 99.5 / 0.5 / ±2 % ±r 50.0 to 149 / 1 / ±2.5 % R ±2r
100 to 199 / 1 / ±3 % ±r 150 to 245 / 5 / ±5 % R ±2r
200 to 395 / 5 / ±5 % ±r 250 to 440 / 10 / ±10 % R ±2r
400 to 590 / 10 / ±10 % ±r 450 to 640 / 10 / ±15 % R ±2r
600 to 1,150 / 50 / Approx. 20 % 650 to 1200 / 50 / ±20 % R ±2r
1,200 to 1,500 / 50 / Approx. 25 %
Measurement frequency 2,083 Hz / Translation frequency Measurement frequency
Frequency 50, 60, 128 or 2,083 Hz 2,083 Hz
Measurement ranges µH) / Resolution / Accuracy
Loop inductance
measurement 10 to 100 / 1 / ±5 %±r
100 to 500 / 1 / ±3 %±r
Contact voltage Measurement ranges (V) / Resolution (V)
(calculation) 0.1 to 4.9 / 0.1
5.0 to 49.5 / 0.5
50.0 to 75.0 / 1
Ammeter 0.5 to 9.995 mA / 50 µA /
0.200 to 0.999 mA / 1 μA / ±2 % ±50 μA
Measurement ranges (A) / ±2 % R ±200 μA
Resolution (A) / Accuracy 10.00 to 99.90 mA / 100 µA /
Display on 4,000 counts 1.000 to 2.990 mA – 3.00 to 9.99 mA / 10 μA / ±2 % ±50 μA ±2 % R ±r
100.00 to 299.0 mA / 1 mA /
10.00 to 29.90 mA – 30.0 to 99.9 mA / 100 μA / ±2 % ±r ±2 % R ±r
0.300 to 2.990 A / 10 mA /
100.0 to 299.0 mA – 0.300 to 0.990 A / 1 mA / ±2 % ±r ±2 % R ±r
3.00 to 20.00 A / 100 mA /
1.000 to 2.990 A – 3.00 to 39.99 A / 10 mA / ±2 % ±r ±2 % ± r
Setup
Modes Standard or advanced Standard
Alarms Configurable on Z, V and A Configurable on Z and I
Buzzer Active
HOLD Manual or automatic PRE-HOLD
Auto power-off Active / Inactive
General specifications
Display 152-segment OLED. Active area 48 x 39 mm
ø 32 mm - LxH : 30 x 40 mm /
Max. clamping diameter Ø 35 mm 20 x 55 mm
Data storage 300 date-stamped measurements 2,000 date-stamped measurements 300 date-stamped measurements
Communication Bluetooth class 2
Power supply 4 x 1.5 V, LR6 (AA) alkaline batteries or 4 x Ni-MH batteries
Battery life 1,440 x 30-second measurements 2,440 x 30-second measurements
Calibration Automatic at startup
CEI 61010 100 V CAT IV,
Electrical safety IEC 61010 600 V CAT IV
150 V CAT III
Ingress protection IP40
Dimensions 55 x 95 x 262 mm 56 x 106 x 300 mm
State at delivery Weight Approx. 935 g with batteries Approx. 1.2 kg with batteries
R = Reading, r = resolution
• CA 6416 : 1 clamp delivered in a carrying case with 4 x 1.5 V batteries, 1
CD-Rom containing the User's Manual in 5 languages, 1 wrist strap
• CA 6417 : 1 clamp delivered in a carrying case with 4 x 1.5 V batteries, 1
CD-Rom containing the User's Manual in 5 languages and the GTT software with
simplified driver, 1 wrist strap
• CA 6418 : 1 clamp delivered in a carrying case with 4 x 1.5 V batteries, 1
CD-Rom containing the User's Manual in 5 languages, 1 wrist strap, 1 quick
startup guide, 1 multilingual safety datasheet, 1 inspection certificate
Accessories
• L1 calibration loop . . . . . . . . . . . . . . . . . . . . . . . . . . P01122301
C
• DataView . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . P01102095
• Hard case . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . P01298080
• Two foam inserts for CA 6418 . . . . . . . . . . . . . Please contact us
28
Locate hidden cables
Transmitter Receiver
300 V
CAT III
CA 6681 LOCAT-N
Reference P01141626
CA 6681E transmitter
Screen LCD screen with display of functions and bargraph
Output signal frequency 125 kHz
External voltage measurement range 12 to 600 VAC/DC
Functions Digital coding of signals for easy signal identification, selection of transmission signal code, torch function
Power supply 9 V battery
Dimensions 190 x 89 x 42.5 mm
Weight 420 g with battery
Electrical safety 300 V CAT III
CA 6681R receiver
Screen Backlit LCD with display of functions and bargraph, transmission code, receiver and transmitter battery-charge status
Detection Depth
> Single-pole application 0 to 2 m
> Two-pole application 0 to 0.5 m
> Simple looping line Up to 2.5 m
Identification of mains voltage Approximately 0 to 0.4 m
Functions Automatic shutdown, automatic or manual adjustment of reception sensitivity, torch function
Power supply 6 x 1.5 V AAA batteries
Dimensions 241.5 x 78 x 38.5 mm
Weight 360 g with batteries
State at delivery
• CA 6681 LOCAT-N: delivered in a hard case with 1 set of red/black 4 mm isolated
banana leads (straight male / elbowed male), 1 set of 2 crocodile clips, 1 stake for earthing,
1 x 9 V battery, 6 x 1.5 V AAA batteries, 1 measurement adapter for B22 socket (bayonet),
1 adapter for E14 socket (screw-in), 1 mains socket adapter and 1 operating manual in
5 languages.
29
TESTING AND ELECTRICAL SAFETY
Micro-ohmmeters IP 50 V
> 4-wire measurement method 53 CAT III
> Test current up to 10 A
> Resolution 0.1 to 1 μΩ CA 6240 CA 6255
Low resistance measurement
Reference P01143200 P01143221
CA 6292
Reference P01143300
Test current Programmable from 20 to 200 A
Resistance 0.1 µW to 2 mW 2 to 200 mW 200 mW to 1 W
Resolution 0.1 µW (200 A max) 10 µW (25 A max to 200 mW) 1 mW ( 5 A max to 1 W)
Output voltage 10 VAC: 4.2 V @ 200 A / 220 VAC: 8.6 V @ 200 A
Maximum load
100 VAC: 20 mW @ 200 A / 220 VAC: 42 mW @ 200 A
resistance
> Constant test at 100 A Measurement method 4 Kelvin-type connection terminals
Test mode Normal or Both Sides Grounded (BSG)
and up to 120 s at 200 A
Test duration Adjustable from 5 to 120s @200 A / unlimited below 100 A
> Test current up to 200 A Data storage Up to 8,000 measurement results
> Resistance from 0.1 μΩ to 1 Ω Interface USB 2.0
> Safe measurements: Software DataView®
Both Sides Grounded (BSG) method Power supply 100 to 240 VAC – 50/60 Hz
Dimensions 502 x 394 x 190 mm
> Storage of up to 8,000 Weight Approx. 13 kg
measurement results Storage temperature -10 °C to +70 °C
Humidity 95% RH
IP
54 BSG
Protection Protected against overvoltages, short-circuits and voltage surges on output terminals
Ingress protection IP54
Electrical safety IEC 61010-1
State at delivery
CA 6292 delivered with:
a case containing 1 set of 2 x 6 m Kelvin leads (red / black) with adjustable-clamp
connections, 1 green earth cable 3m long with crocodile clip, 1 USB cable 1.5m long,
1 fuse T 15 A 250V mounted in the instrument, 1 European mains power cable, 1 user's
manual in 5 languages on CD-ROM,1 CD-ROM containing the DataView software.
30
Ratiometer
> Transformation ratio measurement on
power, voltage and current transformers
> Storage of up to 10,000 measurement
results
IP
53
DTR 8510
Digital ratiometer for transformers
Reference P01143200
Range of ratios (VT) Automatic: 0.8000 to 8,000:1
Range of ratios Accuracy (% of reading)
0.8000 to 9.9999 ± 0.2 %
Accuracy (VT) 10.000 to 999.99 ± 0.1 %
1000.0 to 4999.9 ± 0.2 %
5000.0 to 8000.0 ± 0.25 %
Range of ratios (TC) Autoranging: 0.8000 to 1000.0
Accuracy (TC) ± 0.5 % of reading
VT mode: 32 Vrms max
Excitation signal
CT mode: Auto level 0 to 1 A, 0.1 to 4.5 Vrms
Excitation current display Range: 0 to 1,000 mA; Accuracy: ± (2 % R + 2 mA)
Excitation frequency 70 Hz
Alphanumeric LCD, 2 lines of 16 characters with adjustment of contrast and
Display
backlighting. Easy to read in both daytime and nighttime conditions
Available languages French, English, Spanish, Italian, German, Portuguese
Measurement method According to IEEE Std C57, 12.90™ standard
Power supply Two rechargeable batteries: 12 V, NiMH, 1650 mAH
Battery life Up to 10 hrs in continuous operation, low-battery warning
Battery charger Universal input (90 to 264 Vrms), smart charger
Charging time < 4 hours for full charge
Storage 10,000 tests
Date / time Power supplied by dedicated battery, real-time clock
Communication USB 2.0, optical isolation, 115.2 kB
Software Delivered with DataView® analytical software
Dimensions / Weight 272 x 248 x 130 mm / 3.7 kg
Connection XLR connectors
Leads Screened H and X leads, length 4.6 m (15 ft),equipped with colour-coded crocodile clips
Casing Rugged polypropylene casing, UL 90 V0
Vibrations IEC 68-2-6 (1.5 mm at 55 Hz)
Shocks IEC 68-2-27 (30 G)
Falls IEC 68-2-32 (1 m)
IP 40 with cover open as per EN 60529
Protection rating
IP 53 with cover closed as per EN 60529
Safety EN 61010-1, 50 V CAT IV; pollution degree 2
State at delivery
DTR 8510 delivered with:
Delivered with a carrying bag containing 1 set of 4.6 m leads with crocodile clips, 1 external battery charger with mains power cable, 1 USB cable,
1 NiMH battery datasheet, 1 operating manual and DataView software on CD-Rom
31
Power, energy, disturbances
Power analysers for three-phase networks
> 5 voltage inputs & 4 current inputs
> Inrush mode over 10 minutes
> Calculation of distorting power IP
67
1000 V 600 V 3U 4U IP CEI EN
CAT III CAT IV 4I 4I 53 61000-4-30 50160
State at delivery
• CA 8336 • CA 8333 - CA 8331 - Models without sensors: Qualistar+ analyser delivered with a
bag for accessories, 5 voltage cables 3 m long with 4 mm banana connections, 5 crocodile clips,
a set of 12 coloured elements for identifying cables and inputs, an anti-scratch film to protect the
screen (mounted), a USB cable, a mains power cable, a mains power pack, a safety datasheet, a CD
containing a multilingual user's manual and a CD containing the PC data retrieval software (Power
Analyzer Transfer).
• CA 8436 - 1 bag No. 22, 1 IP67 mains cable, 1 USB cable, 5 x 4 mm banana voltage cables 3
m long, 5 crocodile clips, 1 set of colour-coded rings/inserts for identifying the cables and inputs, 1
anti-scratch screen-protection film (mounted) , 1 safety datasheet, 1 CD-ROM containing the Power
Analyser Transfer PC data recovery software.
32
Software Accessories for all Qualistar+ models
Reference P01102150
Storage tool
Reeling Box
winder for stowing
For transferring data onto a PC and communicating in real time measurement cables
via USB.
Supplied with the Qualistar+ models
Reference P01102149
is compatible with other Chauvin Arnoux® products: MA193 MA193 MA196 A193 A193 A196
• CA 8220 & CA 8230 power analysers -250 -350 -350 -450 -800 -450
• F407 and F607 multimeter clamps
• and other measuring instruments Reference P01120580 P01120567 P01120568 P01120526B P01120531B P01120554
Minimum required operating system: Windows® 7, 8 and 10. Indice IP 67 - - yes - - yes
Measure-
100 mA to 10 kAac
Reference P01102095 ment range
Clamping Ø Ø 70 mm Ø 100 mm Ø 100 mm Ø 140 mm Ø 250 mm Ø 190 mm
/ length / 250 mm / 350 mm / 350 mm / 450 mm / 800 mm / 610 mm
33
Power, Energy, Disturbances
Power and Energy Loggers
> Single-phase, split-phase and three-phase installations
> Installation without cutting off the mains power supply
> Bluetooth, Ethernet and USB Communication
> Automatic recognition of the sensors connected
> Recording on SD card
IP 1000 V 600 V
54 CAT III CAT IV
PEL102 PEL103
Standard reference P01157152 P01157153
Reference with 3 MA 193 current sensors P01157150 P01157151
Display Without With triple digital display
Installation types Single-phase, split-phase, three-phase with or without neutral, and many other specific configurations
Number of channels 3 Voltage inputs / 3 Current inputs (neutral current calculated)
Measurements
Network frequency DC, 50 Hz, 60 Hz & 400 Hz
Voltage (Measurement ranges/ Best accuracy) 10.00 to 1000 V AC/DC / +/- 0.2 % + 0.5 V
Current (depending on sensors)
from 5 mAAC to 10 kAAC / 50 mADC to 1,4 kADC / ±0.5 %
(measurement ranges / best accuracy)
Calculated measurements
Ratios Up to 650,000 V / up to 25,000 A
Power 10 W to 10 GW / 10 var to 10 Gvar / 10 VA to 10 GVA
Energy Up to 4 EWh / 4 EVAh / 4 Evarh (E = 1018 )
Phase cos φ, tan φ, PF
Harmonics Up to 50th order
Additional functions
Phase order Yes
Min / Max Yes
Mounting Magnet, hook
Recording
Sampling / Acquisition rate / Aggregation 128 samples/period - 1 measurement/s – from 1 min to 60 min
Storage SD Card, 8 GB (SD-HC Card up to 32 GB)
Communication Ethernet & Bluetooth
Power supply 110 V - 250 V (+10 %, -15 %) @ 50-60 Hz & 400 Hz
Safety IEC 61010 600 V CAT IV – 1,000 V CAT III
Mechanical specifications
Dimensions 256 x 125 x 37 mm without sensor
Weight 900 g 950 g
Casing IP54 , ETL
34
Power and energy logger
> Ideal for mounting on electricity poles
> All-terrain shockproof casing resistant
to UV light and high temperatures
> Self-powered by its voltage inputs up to 1,000 V
> Continuous recording at 200 ms intervals
> Measurements in compliance with IEEE 1459
1000 V IP
CAT IV 67
PEL 105
Reference P01157155
Display With backlit triple digital display
Type of installation Single-phase, split-phase, three-phase with or without neutral and many other specific configurations
Number of inputs 5 voltage inputs, 4 current inputs
Number of channels 4 voltage channels, 4 current channels
Measurements
Network frequency DC, 50 Hz, 60 Hz and 400 Hz
Voltage (measurement ranges / best accuracy) 10.00 V to 1,000 VAC @ 50/60 Hz, or 600 VAC @ 400 Hz / 1,000 VDC
Current (depending on sensors) 5 mAAC to 10 kAAC / 50 mADC to 1.4 kADC
(measurement ranges / best accuracy)
Calculated measurements
Ratio Up to 650,000 V / up to 25,000 A
Power 20 W to 10 GW / 20 var to 10 Gvar / 20 VA to 10 GVA
Energy Up to 4 EWh / 4 EVAh / 4 Evarh (E = 1018)
Phase cos φ, tan φ, PF
Phase sequence Automatic selection of the phase sequence
Harmonics Up to the 50th order
Additional functions
Phase sequence Indication of valid connection
Min / Max On all quantities
Recording
Sampling rate/ Acquisition rate / Aggregation 128 samples/period - 5 measurements/s - from 1 min to 1 hr
Storage SD card, 8 GB (up to 32 GB with SD-HC card)
Communication Ethernet, Bluetooth, Wifi and USB
Power supply Self-powered internally from 94 to 1,000 V @ 50-60 Hz & 400 Hz / DC
Safety IEC 61010 1,000 V CAT IV
Mechanical specifications
Dimensions 245 x 270 x 180 mm
Weight < 4 kg
Protection IP 67
Reference P01102149
35
PORTABLE OSCILLOSCOPES
Portable oscilloscopes with isolated channels
600 V IP
CAT III 54
OX 5022 OX 5042
Bandwidth 20 and 40 MHZ
36
On-site oscilloscopes
with isolated channels Scan this code
To find out more about the
Scopix IV - 5 instruments in 1: 600 V IP Scopix® offering:
> oscilloscope
> FFT
CAT III 54
> multimeter
> logger & harmonic analyser
> wattmeter
General specifications
LCD colour screen 5.7/7/3.5" 7" 7" 7" 7"
Soft calibration with 100% "closed casing" • • • •
State at delivery 1 SCOPIX IV oscilloscope delivered in a carrying bag, 1 PA40W-2 power pack / charger and one 2P EURO mains cable, 1
Li-Ion battery pack, 1 stylus, 1 Ethernet cable, 1 USB cable, 2 safety cables (red, black), 2 x Ø 4 mm test probes (red, black),
SCOPIX IV 2 or 4 voltage probes depending on models, 1 μSD card (8 GB), 1 USB/ μSD adapter, 1 hand strap, 1 PROBIX BANANA,
1 USB installation procedure for use of the ScopeNet data export software on CD-ROM, 1 pdf User's Manual on CD (>5
languages), 1 startup guide on paper and 1 safety datasheet in 20 languages.
State at delivery SCOPIX BUS delivered in a bag with 1 mains adapter/charger, 1 LI-ION battery pack, 1 stylus, 2 x 1/10 Probix HX0130
probes, 1 x Ø4 mm Probix banana adapter, 1 set of cables + Ø4 mm banana test probe, 1 Ethernet cable, 1 USB cable,
SCOPIX BUS 1 μSd card (8 GB) with SD Card adapter, HX0190 and HX0191 bus connection boards, 1 CD-Rom containing the User's
Manual, Programming Manual and SX-BUS 2.0 software.
37
Current Measurement Scan this code
for further
information about
AC and AC/DC current measurement the clamps:
(oscilloscopes)
• Female sockets ø 4 mm
• Automatic DC zero
• Typical accuracy
• Very low current
• Medium current
• BNC connector
• High current
• Low current
(input/output)
• Voltage
• Current
--- DC
• ~ AC
Series Model To order
• ...
35 mm MINI 01 2 to 150 A • 0.15 A AC • 1,000/1 • 48 Hz... 500 Hz ≤ 2.5 % P01051101Z
34 mm 130,4 mm
MINI 102 0.05 A - 200 A • 0.2 Aac • 1,000/1 48 Hz...10 kHz ≤ 1% P01106102
46 mm
Ø16 mm
MINI 103 0.1 A - 200 A • 0.2 V AC • 1 A / 1 mV 48 Hz...10 kHz ≤ 1.5% P01106103
Ø 21mm
MN08 0.5 to 240 A • 0.2 A AC • 1,000/1 40 Hz... 10 kHz ≤ 1 % P01120401
18,5
mm
MN09 0.5 to 240 A • 0.2 A AC • 1,000/1 40 Hz... 10 kHz ≤ 1 % P01120402
• • •
31 mm
C148 1 to 600 A
1 to 1,200 A
• 5 A AC • 500/5
1,000/5
• 48 Hz... 1 kHz ≤ 1 % P01120307
≤1%
1 mA to 1.2 A 1 A/1 V ≤ 0.7 %
0.01 to 12 A 10 A/1 V
99 mm
C173 0.1 to 120 A • 1 V AC • 100 A/1 V
10 Hz... 3 kHz ≤ 0.5 % P01120309
≤ 0.3 %
1 to 1,200 A 1,000 A/1 V ≤ 0.2 %
D30CN 1 to 3,600 A • 1 A AC • 3,000/1 • • 30 Hz... 5 kHz ≤ 0.5 % P01120064
48 mm
m
310 m
Ø64 mm 310 mm
D36N 1 to 3,600 A • 3 A AC • 3,000/3 • • 30 Hz... 5 kHz ≤ 0.5 % P01120055A
1 mA to 4.5 A DC 4.5 V DC
15
mm
K1 1 mA to 3 A RMS
1 mA to 4.5 A peak
• • 3 V RMS
4.5 V peak
• 1 mA/1 mV DC... 2 kHz ≤1% P01120067A
m
1m
11
5 mA to 2 A DC 2 V AC
1 A/1 V DC... 2 kHz ≤2%
Ø 11,8 mm E6N 5 mA to 1.5 A AC
20 mA to 80 A AC/DC
• • 1.5 V AC
0.8 V AC/DC
• 1 A/10 mV DC... 8 kHz ≤4%
P01120040A
20 mm
(1) The higher value corresponds to 120% of the max. rated value (2) Reshaping of AC signal by diodes (3) Lead + electronic unit with Ø 4 mm safety plugs, 19 mm spacing, for K series
38
AC/DC current measurement
Input(1) Output / Connections Specific features
(oscilloscopes)
• Power measurements
• Transformation ratio
ø 4 mm safety plug
• Automatic zero DC
• Typical accuracy
• Very low current
• Medium current
• BNC connector
overvoltages
• High current
• Low current
(frequency in Hz)
(low phase shift)
• Bandwidth
• Cables +
input/output)
• Current
• Voltage
--- DC
• ~ AC
Series Model To order
•O
• ...
Ø 30 mm
or 2 x Ø 24 mm
0.5 to 400 A AC
PAC15 0.5 to 600 A DC • • 600 mV
AC/DC • 1 A/1 mV • DC... 30 kHz ≤ 2 % P01120115
224 mm
0.5 to 40 A AC
≤ 1.5 %
• • •
0.5 to 60 A DC 600 mV AC/DC 1 A/10 mV
PAC16 0.5 to 400 A AC 600 mV AC/DC • 1 A/1 mV
• DC... 30 kHz
≤2%
P01120116
0.5 to 600 A DC
0.5 to 40 A AC
1 A/10 mV ≤ 1.5 %
AC/ PAC17
0.5 to 60 A DC
0.5 to 400 A AC • • • 600 mV peak
600 mV peak
• 1 A/1 mV
• DC... 30 kHz
≤2%
P01120117
97 mm
DC 0.5 to 600 A DC
Ø 39 mm
or 2 x Ø 25 mm
or 2 x (50x5) mm
PAC25 0.5 to 1000 A AC
0.5 to 1400 A DC
• • 1.4 V AC/DC • 1 A/10 mV
• DC... 30 kHz ≤ 4 % P01120125
236,5 mm
0.5 to 100 A AC
PAC26 0.5 to 150 A DC
0.5 to 1000 A AC
• • 1.5 V AC/DC
1.4 V AC/DC • 1 A/10 mV
1 A/1 mV • DC... 30 kHz
≤ 1.5 %
P01120126
≤4%
0.5 to 1400 A DC
0.5 to 100 A AC
≤ 1.5 %
PAC27
0.5 to 150 A DC
0.5 to 1000 A AC
• • 1.5 V peak
1.4 V peak • 1 A/10 mV
1 A/1 mV • DC... 30 kHz
≤4%
P01120127
97 mm 0.5 to 1400 A DC
(oscilloscopes)
• Female sockets ø 4 mm
• Automatic DC zero
• Typical accuracy
• Very low current
• Medium current
• BNC connector
• High current
• Low current
(input/output)
• Voltage
• Current
DC
• ~ AC
0.1 A to 60 A peak
MN60 0.5 A to 600 A peak • 6 V peak • 1 A / 100 mV
1 A / 10 mV
40 Hz to 40 kHz
≤2%
≤ 1.5 %
P01120409
1 A to 90 A peak 1 A / 10 V
10 V A AC
AC
D38N 1 A to 900 A peak
1 A to 9,000 A peak
• 0.1 V AC • 1 A / 1 mV
1 A / 0,1 mV
30 Hz to 50 kHz ≤ 2 % P01120057A
MA200 5 Hz to 1 MHz
30-300/3
(35 cm)
5 A … 4,500 A peak • 4.5 V peak • 1 mV / A phase shift at
1 kHz ≤ 1.5°
≤1%
+ 0.3 A
P01120572
0.05 A to 10 A peak
E3N 1 A to 100 A peak • • 1 V peak • 1 A / 10 mV
1 A / 1 mV
DC to 100 kHz
≤3%
≤4%
P01120043A
AC/
DC MH60 0.01 A - 140A peak • • 0.01 A -
• 10 mV/A • DC to 1 MHz ≤ 1.5 % P01120612
140A peak
(1) The higher value corresponds to 120 % of the max. rated value (2) Lead + electronic unit with Ø 4 mm safety plugs with 19 mm spacing for the AmpFLEX series
39
Current Measurement
AC current measurement
MA400D, MA4000D
600 V
CAT IV TRMS
Automatic DC zero
Alternating current
(frequency in Hz)
Typical accuracy
Very low current
Medium current
Direct current
High current
Low current
Bandwidth
Current
Voltage
300 A
3A
OFF
OL
On
3 A : 1000 mV /A
30 A : 100 mV /A
300 A : 10 mV /A
3000 A : 1 mV /A
A 110
AC CURRENT PROBE
600 V CAT IV
1000 V CAT III
L1 L2 L3
30 A
300 A
L2 L3
L3
L2
L1
OFF
OL
On
30 A : 100 mV /A
300 A : 10 mV /A
3000 A : 1 mV /A
A 130
AC CURRENT PROBE
L1 L3
600 V CAT III
L2
40
MiniFlex® flexible probes for AC current
MA110, MA130 MA200
Other dimensions:
Other dimensions: contact us
contact us
Automatic DC zero
Alternating current
(frequency in Hz)
Typical accuracy
Very low current
Medium current
Direct current
overvoltages
High current
Low current
phase shift)
Bandwidth
Current
Voltage
output)
300 A
3A
3000 A
10 mV/A 10 Hz .. 20 kHz
0.5 A .. 3,000 A 1 mV/A 10 Hz .. 20 kHz
OFF
OL
On
3 A : 1000 mV /A
30 A : 100 mV /A
300 A : 10 mV /A
3000 A : 1 mV /A
MA 110
AC CURRENT PROBE
600 V CAT IV
1000 V CAT III
3000 A
OFF
OL
L3
P Auto Power Off
On
30 A : 100 mV /A
300 A : 10 mV /A
3000 A : 1 mV /A
MA 130
AC CURRENT PROBE
L1 L3
L2
600 V CAT III
41
DATA PROCESSING SOFTWARE
Power quality Scan this code
& installation supervision to find out more
about DataView's
performance features
Functions
> Configuration of all the functions of instruments
connected to a PC or via Bluetooth
> Recovery of the recorded measurement data
> Backup of measurement files
> Opening of saved files
> Processing and creation of reports (EN50160)
> Export into an Excel spreadsheet
> Export in .pdf format
> Database management
Additional info
The Dataview® software
> Automatically recognizes the instrument connected
when it is connected to the PC and opens
the corresponding menu. Users then have direct access
Reference P01102095
to the configuration and to the saved data
> Includes a large number of predefined report templates
for quick generation in compliance with the applicable
standards. Users can create their own models
to fit their needs and add their own comments directly
42
Index
… by function
A D M
Accessories: DataView® software p.42 Megohmmeters (see Insulation testers)
• Ø 4 mm banana connections p.38 Digital ammeters with flexible sensor p.40 Micro-ohmmeters p.30
• transport (soft cases, hard cases, bags) p.38 Digital insulation testers p.20-21
• protection (soft cases, hard cases, bags) p.38 Digital tester p.10
O
On-site digital oscilloscopes p.36-37
AC current miniclamps p.38
AmpFlex® p.29
E P
Earth and resistivity kit p.27
AmpFlex® clamps p.29 pH-meter p.15
Earth/ground and resistivity testers p.26
ASYC IV digital multimeters p.08 pH-tester p.14
Earth/ground and resistivity testers with adapter
Power Analyser Transfer software p.33
C for pylon earth measurements p.27
Power and energy loggers p.34
Cable locator p.25 Earth/ground testers p.19
Clamp meters: Electrical power analysers for three-phase networks p.32-33 R
• AC current clamps p.29-30
• AC/DC current clamps p.25-31
F Ratiometer
Reeling box
p.31
p.33
Flexible current sensors p.40-41
• digital clamp multimeters p.04-05
• earth/ground clamps and loop tester p.24 I T
Testers p.10
CO2 / Temperature / Humidity measurement p.12 Installation testers p.16-17
Thermal cameras p.16-17
Conductivity meter p.14 Insulation and continuity testers p.18-19
Thermo-anemometers p.13
Contact thermometers p.11
L Thermo-hygrometers p.12
Luxmeters p.13 TRMS digital multimeters p.06
V
Voltage detector p.10
… by product
A E
A110/130 Flexible current sensors p.40 Earth/ground and resistivity kit p.27
A193-450/A193-800 AmpFlex® clamp meters p.34 E3N AC/DC current clamp p.34
A196 AmpFlex® clamp meters p.34
AmpFlex® Flexible current sensors p.40 F
F201/203/205 Digital clamp multimeters p.04-05
B F401/403/405/F407 Digital clamp multimeters p.04-05
Banana connection accessories Ø 4 mm p.42
F603/605/F607 Digital clamp multimeters p.04-05
C J
C100 to C173 AC AC current clamps p.38
C193 AC current clamp p.34 J93 AC/DC current clamp p.34
CA 1110
CA 1227
Luxmeters
Thermo-anemometers
p.13
p.13
K
K1/K2 AC/DC current clamps p.38
CA 1246 Thermo-hygrometers p.12
CA 1510 CO2 - Temperature – Humidity logger p.12 M
CA 1821/1822/1823 Logger contact thermometers p.11 MA 100 Flexible current sensors p.37
CA 1950/1954 Thermal camera p.16-17 MA193 AC current clamps p.29-30
CA 1821/1822/1823 Logger contact thermometers p.11
MA 200 Flexible current sensors p.39
CA 1950/1954 Thermal camera p.16-17
CA 5273/5275/5277 TRMS multimeters p.08 MA400D/MA4000D Flexible current sensors p.36
CA 6011 Installation tester p.18 MINI 01/02/03/05/09/102/103 AC current clamps p.38
CA 6116N/6117/6133 Installation testers p.20-21 MN60 AC current clamp p.39
CA 6240/6250 Micro-ohmmeters p.26 MN 08 to MN 89 AC current clamps p.38
CA 6292 Micro-ohmmeters p.30 MN93/93A AC current clamps p.34
CA 6416/6417 Earth clamp meters and loop testers p.28 MTX 203/204 TRMS digital multimeters p.06
CA 6422/6424 Earth/ground tester p.19 MTX 3290/3291/3292/3293 Digital multimeters p.07
CA 6460/6462/6470N/6471 Earth/ground and resistivity testers p.26
CA 6472/6474 Earth/ground and resistivity testers with O
adapter for pylon earth measurement p.27 OX 5022/5042 On-site digital oscilloscopes p.36
CA 6505 Digital insulation tester p.21
OX 9302-BUS/9062/9102/9104/9304 On-site oscilloscopes p.37
CA 6522/6524/6526/6532/6534/6536 Insulation and continuity testers p.22-23
CA 6528 Insulation tester p.18 P
CA 6541/6543/6545/6547/6549 Digital insulation testers p.24 PAC15/16/17/25/26/27 AC/DC current clamps p.39
CA 6550/6555 Digital insulation testers p.25 PAC93 AC/DC current clamps p.34
CA 6681 Cable locator p.29
PEL 102/103/105 Power and energy loggers p.34
CA 757 Digital tester p.10
Power Analyser Transfer Software p.33
CA 773 Voltage Absence Tester p.10
CA 8331/8333/8336/8436
Electrical power analysers for three-phase
networks p.32-33
R
Reeling Box Cable reeler p.29
CA 10001 pH tester p.14
CA 10101 pH-meter p.15 Y
CA 10141 Conductivity meter p.14 Y1N AC current clamp p.34
D Y7N AC current clamp p.35
DataView® software p.38
D30CN / D36N AC current clamps p.34
D38N AC current clamp p.34
DTR 8510 Single-phase ratiometer p.31
43
ELECTRICAL TESTING AND SAFETY
NEW