DDM-3020 Diameter Gauge
DDM-3020 Diameter Gauge
DDM-3020 Diameter Gauge
,Ltd
Suzhou Newlead Augmented Intelligence Equipment Co.Ltd
2
No2401,Jingchang Tech park, Suzhou city,JiangSu province,China
008618913191585 jerrypro@qq.com www.newleadgroup.com
│ │
│ │
│ │
Power socket Comm interface
Figure1-2 Diameter gauge panel Figure1-3 Power socket and comm interface
2 Mounting
2.1 Mounting position
DDM-3020 Diameter Gauge may be mounted either before or after the cooling trough when it is used with
the wire and cable production line. When the Gauge is mounted before the cooling trough, optimal control
can be achieved due to in-time feedback resulting from short distance from the Gauge to the extruder. But
the measurement at this position is usually somewhat larger than the actual diameter because the plastic
melt has not been solidified and the measurement is the diameter of the hot-state wire or cable; for this
reason, the set nominal shall be increased appropriately. When the Gauge is mounted after the cooling
trough, the measurement will be more accurate because it reflects the actual diameter. But the control effect
becomes worse due to large control lag. Besides, the tested wire or cable shall be wiped dry otherwise the
water film on the surface of the wire or cable will affect adversely the measuring accuracy. In actual
operation, the set nominal shall be increased appropriately according to the water content of the tested
object.
Indicator flashes, indicating that the difference between the measured diameter and nominal exceeds
Indicator is bright, indicating that the current operating mode is nominal display/setting
Indicator is bright, indicating that the current operating mode is tolerance display/setting
Indicator is bright, indicating the feedback control is on in the normal operation mode and feedback
Indicator flashes, indicating the feedback control is frozen in the normal operating mode and
Indicator is bright, indicating that the digital display is used for lump & neck alarm count in the
4
No2401,Jingchang Tech park, Suzhou city,JiangSu province,China
008618913191585 jerrypro@qq.com www.newleadgroup.com
normal operating mode and lump & neck parameter display/setting in the parameter setting mode.
Indicator flashes, indicating presence of non-reset lump & neck alarm output.
Indicator is bright, indicating that the current operating mode is parameter display/setting
Indicator is bright, indicating that the LEB displays the location of the tested object in the
measuring range.
(2) When lump & neck detection is enabled, press【Lump & neck key】when the measured diameter is
displayed to indicate the lump & neck alarm count for ca. 20s. Display format:mark for lump & neck
alarm count“ ” followed by a 4-digit decimal number, which indicates the detected alarm count in
the range of 0000~9999. If 9999 is exceeded,the number 9999 will flash. For example, for a current
alarm count of 25, the following will be displayd:
Press 【Lump & neck key】once more when the lump & neck alarm count is displayed to clear the
lump & neck alarm count and return to the measured diameter display mode.
To sum up, the digital display is used only to display the measured diameter when lump & neck
detection is disabled. It is used to diaplay the measured diameter or lump & neck alarm count when
lump & neck detection is enabled. Conversion from one display mode to another is shown below:
Fault cause:The tested object is at a location too high exceeding the upper limit of the measuring
range.
Fault removal:Lower the wire pulley or raise the diameter measuring head so that the tested wire
or cable is located within the measuring range of the Gauge.
Fault cause:The tested object is at a location too low exceeding the lower limit of the measuring
range.
Fault removal:Raise the wire pulley or lower the diameter measuring head so that the tested wire
or cable is located within the measuring range of the Gauge.
Fault cause 1:The lens is irradiated directly by an external strong light (e.g. sunlight).
Fault removal 1:Block any external strong light.
Fault cause 2:Displacement of the light source or lens system
Fault removal 2:Contact the after-sales department of Shanghai On-Line.
Fault cause 1:Lens of the Gauge is badly polluted by dust etc resulting in partially blocked light
emmission
Fault removal 1:Same as for fault(1).
Fault cause 2:The tested object is transparent (e.g. glass tube) or more than one tested object in the
measuring range.
Fault removal 2:Use the Gauge that can measure transparent object or more than one tested object
at the same time.
Fault cause:The tested object is too thin(below φ0.5mm)and located so far away from the centre
(too near to the dust cover) that proper imaging by the optical system is not possible.
Fault removal:Locate the tested object at the centre(keeping equal distance from the dust cover at
either side as far as possible).
Fault cause:Loose connection between the main board and display panel
Fault removal:Contact the after-sales department of Shanghai On-Line
8
No2401,Jingchang Tech park, Suzhou city,JiangSu province,China
008618913191585 jerrypro@qq.com www.newleadgroup.com
(9) Fault message:
(10)Fault message:
(11)Fault message:
(12)Fault message:All segments of the LEB display and the feedback control indicator flash
simultaneously.
4 Parameter display/setting
The parameter display mode is used to view the individual parameters. While the parameter setting mode is
used to change the existing parameter value and save the new parameter value. The parameters for
DDM-3020 Diameter Gauge can be classified into three types, i.e., working parameters, feedback control
parameters and system parameters. Press 【Parameter key】in the normal operation mode or abnormal
alarm mode to enter directly the working parameter display mode. Password is necessary to enter the
feedback control parameter or system parameter display/setting mode. Conversion among the normal
operation mode(or abnormal alarm mode), parameter display mode and parameter setting mode is shown
below:
9
No2401,Jingchang Tech park, Suzhou city,JiangSu province,China
008618913191585 jerrypro@qq.com www.newleadgroup.com
4.1 Working parameter
The working parameter menu contains nominal diameter, tolerance(or positive tolerance, negative
tolerance), lump & neck limit(or lump & neck positive limit, lump & neck negative limit), lump & neck
detection time, feedback parameter password and system parameter password.
Press 【Parameter key】in the normal operation mode or abnormal alarm mode to enter the working
parameter display mode. The first parameter in the menu (i.e., nominal diameter) will be displayd
immediately. Press 【Increase key】 to display the previous parameter in the menu. Press 【Decrease key】
to display the next parameter in the menu.
The parameters in the menu vary with different setting of tolerance setting type, lump & neck limit setting
type and feedback control mode.
┌──────┐
│ Nominal diameter │
└──────┘
┌──────┐ ┌──────┐
│ Tolerance │ │ Positive tolerance │
└──────┘ └──────┘
┌──────┐
│ Negative tolerance │
└──────┘
L & N limit setting type=0 L & N limit setting type =1 L & N limit setting type=2
┌──────┐ ┌──────┐
│ L & N limit │ │L & N positive limit │
└──────┘ └──────┘
┌──────┐
10
No2401,Jingchang Tech park, Suzhou city,JiangSu province,China
008618913191585 jerrypro@qq.com www.newleadgroup.com
│L & N negative limit │
└──────┘
┌──────┐
│L & N detection time│
└──────┘
Feedback control mode=0 Feedback control mode=1, 2, 3
┌──────┐
│Feedback parameter password│
└──────┘
┌──────┐
│System parameter password│
└──────┘
Note:(1) When tolerance setting type=1,the positive and negative tolerances are equal. They are
combined into one single parameter tolerance.
(2) When lump & neck limit setting type=0,lump & neck detection is disabled. At this time, no
parameters relating to lump & neck detection will appear in the working parameter menu.
(3) When lump & neck limit setting type=1,the lump & neck positive and negative limits are
equal. They are combined into one single lump & neck limit.
(4) When feedback control mode=0,feedback control is disabled. At this time, no feedback
parameter password will appear in the working parameter menu, namely, the feedback control
parameter menu cannot be entered.
Let us take two examples to explain the content of the working parameter menu in different conditions and
related operating procedures. In the following chart, “↑” indicating “press 【Increase key】”, “↓”
indicating “press 【Decrease key】”,the key above a horizontal line indicating operation from left to right,
the key under a horizontal line indicating operation from right to left, the final “……” indicating return to
the first option of the menu.
(1)Tolerance setting type=1, lump & neck limit setting type=0, feedback control mode=1(factory
default):
↑↓
│ ┌──────┐ 【Shift key】 ┌──────┐
└ ←──────── │System parameter password│─────→ │ Password input │
【Parameter key】 └──────┘ └──────┘
↑↓
(2)Press【Shift key】to enter the nominal setting mode,the first digit on the display “0” flashes.
(3)Press【Shift key】,the second digit “0” flashes. Press【Increase key】4 times to change “0” into “4”.
(4)Press【Shift key】,the third digit “0” flashes. Press【Increase key】 8 times (or press【Decrease
key】 2 times)to change “0” into “8”.
(5)Press【Parameter key】to save the change and return to the nominal display mode.
(6)If it is necessary to set another parameter,press【Increase key】or【Decrease key】to locate this
parameter. Otherwise press【Parameter key】to return to the normal operation mode.
The first digit “ ̄” in the above indication is the mark for single tolerance.
(3)Press【Shift key】to enter the tolerance setting mode”. The second digit on the display “0” flashes.
(4)Press【Shift key】,the third digit “0” flashes. Press【Increase key】once to change “0” into “1”.
(5)Press【Shift key】,the fourth digit “1”flashes. Press【Increase key】once to change “1” into “2”.
(6)Press【Shift key】,the fifth digit “5” flashes. Press【Increase key】 5 times to change “5” into “0”.,
(7)Press【Parameter key】to save the change and return to the tolerance display mode.
(8)If it is necessary to set another parameter,press【Increase key】or【Decrease key】to locate this
parameter. Otherwise press【Parameter key】to return to the normal operation mode.
The first digit “ ̄” in the above indication is the mark for positive tolerance.
(3)Press 【Shift key】to enter the positive tolerance setting mode. The second digit on the display “0”
flashes.
(4)Press【Shift key】,the third digit “0” flashes.
(5)Press【Shift key】,the fourth digit “1” flashes.
(6)Press【Shift key】,the fifth digit “5” flashes. Press【Decrease key】5 times to change “5” into ”0”.
(7)Press【Parameter key】to save the change and return to the positive tolerance display mode.
(8)If it is necessary to set another parameter,press【Increase key】or【Decrease key】to locate this
parameter. Otherwise press【Parameter key】to return to the normal operation mode.
The first digit “ ” in the above indication is the mark for negative tolerance.
(3) Press【Shift key】to enter the negative tolerance setting mode. The second digit on the display “0”
flashes.
(4)Press【Shift key】,the third digit “0” flashes.
(5)Press【Shift key】,the fourth digit “0” flashes. Press【Decrease key】once to change “0” into”9”.
(6)Press【Parameter key】to save the change and return to the negative tolerance display mode.
(7)If it is necessary to set another parameter,press【Increase key】or【Decrease key】to locate this
parameter. Otherwise press【Parameter key】to return to the normal operation mode.
The first two digits “d ̄” in the above indication are the mark for single lump & neck limit.
(3) Press【Shift key】to enter the lump & neck limit setting mode. The third digit on the display “0”
flashes.
(4)Press【Shift key】,the fourth digit “0” flashes. Press【Increase key】twice to change “0” into ”2”.
(5)Press【Shift key】,the fifth digit “5” flashes. Press【Decrease key】5 times to change “5” into ”0”.
(6)Press【Parameter key】to save the change and return to the lump & neck limit display mode.
(7)If it is necessary to set another parameter,press【Increase key】or【Decrease key】to locate this
parameter. Otherwise press【Parameter key】to return to the normal operation mode.
The first two digits “d ̄” in the above indication are the mark for lump & neck positive limit.
(3)Press【Shift key】to enter the setting mode of lump & neck positive limit. The third digit on the display
“0” flashes.
(4)Press【Shift key】,the fourth digit “2” flashes. Press【Decrease key】twice to change “2” into ”0”.
(5)Press【Shift key】,the fifth digit “5” flashes. Press【Decrease key】5 times to change “5” into ”0”.
(6)Press【Parameter key】to save the change and return to the display mode of lump & neck positive limit.
(7)If it is necessary to set another parameter,press【Increase key】or【Decrease key】to locate this
parameter. Otherwise press【Parameter key】to return to the normal operation mode.
The first two digits “d ” in the above indication are the mark for lump & neck negative limit.
(3)Press 【Shift key】to enter the setting mode of lump & neck negative limit. The third digit on the
display “0” flashes. Press【Increase key】once to change “0” into ”1”.
(4)Press【Shift key】,the fourth digit “2” flashes. Press【Decrease key】twice to change “2” to ”0”.
(5)Press 【Parameter key】to save the change and return to the display mode of lump & neck negative
limit.
(6)If it is necessary to set another parameter,press【Increase key】or【Decrease key】to locate this
parameter. Otherwise press【Parameter key】to return to the normal operation mode.
The first two digits “dt” in the above indication are the mark for lump & neck detection time.
(3)Press【Shift key】to enter the setting mode of lump & neck detection time. The last digit on the display
“5” flashes. Press【Decrease key】4 times to change “5” into “1”.
(4)Press【Parameter key】to save the change and return to the display mode of lump & neck limit.
(5)If it is necessary to set another parameter,press【Increase key】or【Decrease key】to locate this
parameter. Otherwise press【Parameter key】to return to the normal operation mode.
(3)Press 【Shift key】to enter the input mode of feedback parameter password. The first “-” after “F”
becomes a flashing “0”. Press【Increase key】once to change “0” into “1”.
(4)Press 【Shift key】,the second “-” becomes a flashing “0”. Press【Increase key】 twice to change
“0” into “2”.
(5)Press 【Shift key】,the third “-” becomes a flashing “0”. Press【Increase key】 3 times to change
“0” into “3”.
(6)Press【Shift key】,the fourth “-” becomes a flashing “0”. Press【Increase key】 4 times to change
“0” into “4”.
(7)Press【Parameter key】to confirm the input. When a correct password is input, the system enters the
feedback parameter menu. When a wrong password is input, the system returns to the normal
operation mode.
(3)Press【Shift key】to enter the input mode of system parameter password. The first “-” from the left
becomes a flashing “0”. Press【Increase key】7 times(or press【Decrease key】 3 times)to change
“0” into “7”.
(4)Press【Shift key】,the second “-” becomes a flashing “0”. Press【Increase key】 4 times to change
“0” into “4”.
(5)Press【Shift key】,the third “-” becomes a flashing “0”. Press【Increase key】 6 times to change “0”
into “6”.
(6)Press【Shift key】,the fourth “-” becomes a flashing “0”. Press【Increase key】8 timesto change “0”
into “8”.
(7)Press【Shift key】,the fifth “-” becomes a flashing “0”. Press【Increase key】 3 times to change “0”
into “3”.
(8)Press【Parameter key】to confirm the input. When a correct password is input, the system enters the
system parameter menu. When a wrong17password is input, the system returns to the normal
No2401,Jingchang Tech park, Suzhou city,JiangSu province,China
008618913191585 jerrypro@qq.com www.newleadgroup.com
operation mode.
┌────────┐
│Input feedback parameter password│
└────────┘
│
【Parameter key】│
┌─────────────┤
│Wrong password │Correct password
↓ ↓
┌──────┐ ┌────────┐ 【Shift key】 ┌────────┐
│Normal operation
mode│ ←──── │ PI coefficient display│ ←───→ │PI coefficient setting│
└──────┘【Parameter key】└────────┘ 【Parameter key】 └────────┘
↑ ↑↓
│ ┌────────┐ 【Shift key】 ┌────────┐
└──────── │Feedback control mode display│←───→ │Feedback control mode setting│
【Parameter key】└────────┘ 【Parameter key】└────────┘
↑↓
When the feedback control mode = 2(advanced feedback control mode for extruder control)or = 3
(advanced feedback control mode for capstan control),the feedback parameter menu has the structure as
follows::
┌────────┐
│Input feedback parameter password│
└────────┘
│
【Parameter key │
┌─────────────┤
│Wrong password │Correct password
↓ ↓
┌──────┐ ┌───────┐ 【Shift key】 ┌───────┐
│Normal operation
mode│ ←──── │Rated line speed display│←────→ │Rated line speed setting│
└──────┘【Parameter key】 └───────┘ 【Parameter key】 └───────┘
↑ ↑↓
│ ┌───────┐ 【Shift key】 ┌───────┐
├←────────│ Wire diameter display │←────→ │ Wire diameter setting │
│【Parameter key】 └───────┘ 【Parameter key】└───────┘
│ ↑↓
│ ┌───────┐ 【Shift key】 ┌───────-┐
├←────────│Self rectification18display │ ←──-─→ │ Self rectification
No2401,Jingchang Tech park, Suzhou city,JiangSu province,China
008618913191585 jerrypro@qq.com www.newleadgroup.com
ready/operation│
│【Parameter key】 └───────┘ 【Decrease key】└──────-─┘
│ ↑↓
│ ┌───────┐ 【Shift key】 ┌───────┐
├←────────│ Wire travel length display │←────→ │ Wire travel length setting │
【Parameter key】 └───────┘ 【Parameter key】 └───────┘
│ ↑↓
│ ┌───────┐ 【Shift key】 ┌───────┐
├←────────│ Integral coefficient display │←────→ │ Integral coefficient setting │
【Parameter key】 └───────┘ 【Parameter key】 └───────┘
│ ↑↓
│ ┌───────┐ 【Shift key】 ┌───────┐
├←────────│ Proportional coefficient display │←────→ │ Proportional coefficient setting
│ 【Parameter key】 └───────┘ 【Parameter key】 └───────┘
│ ↑↓
│ ┌─────────┐
├←──────── │Rectified nominal diameter display│
【Parameter key】 └─────────┘
│ ↑↓
│ ┌──────────┐
├←──────── │Rated main machine given voltage display│
【Parameter key】 └──────────┘
│ ↑↓
│ ┌────────┐ 【Shift key】┌────────┐
└←──────│Feedback control type display│←─── │Feedback control type setting│
【Parameter key└────────┘ 【Parameter key】└────────┘
↑↓
4.2.1 Setting procedures for feedback control parameter
The general procedures for setting feedback control parameter is as follows:
(1)Input the correct feedback parameter password(see 4.1.9). Press 【Parameter key】to confirm the
input and enter the feedback parameter menu.
(2)Press【Increase key】or【Decrease key】to locate the corresponding parameter.
(3)Press【Shift key】to enter the parameter setting mode.
(4)Press【Increase key】or【Decrease key】and【Shift key】to change the parameter value.
(5)After the change has been made,press【Parameter key】to save the change and return to the parameter
display mode.
(6)If it is necessary to set another feedback control parameter,press【Increase key】or【Decrease key】
to locate the parameter. Otherwise press【Parameter key】to return to the normal operation mode.
(3)Press 【Shift key】to enter the setting mode of proportional-integral coefficient. The second digit on
the display “1” flashes.
(4)Press【Shift key】,the third digit “5” flashes. Press【Increase key】 3 times to change “5” into “8”.
(5)Press【Shift key】,the fourth digit “1” flashes.
(6)Press【Shift key】,the fifth digit “5” flashes. Press【Decrease key】 5 times to change “5” into “0”.
(7)Press 【Parameter key】to save the change and return to the display mode of proportional-integral
coefficient.
(8)If it is necessary to set another feedback control parameter,press【Increase key】or【Decrease key】
to locate the parameter. Otherwise press【Parameter key】to return to the normal operation mode.
(3)Press【Shift key】to enter the setting mode of feedback control type. At this time all the 4 letters NAnu
flash simultaneously.
(4)Press【Increase key】to change NAnu into Auto (automatic). For autmatic control, the following
indication appears:
The letter U in the above indication is the mark for rated line speed.
Setting procedures:See 4.2.1.
The letter d in the above indication is the mark for conductor diameter
Setting procedures:See 4.2.1.
(2)Press 【Shift key】 in the self rectification display mode to enter the self rectification ready mode
where,
Indicators are bright. The measured diameter flashes on the digital display. All segments of
the LEB display are dark. Once the system enters 21this mode,it will not quit it automatically. It is only
No2401,Jingchang Tech park, Suzhou city,JiangSu province,China
008618913191585 jerrypro@qq.com www.newleadgroup.com
possible to manualy press 【Increase key】 to enter the self rectification operation mode or press
【Decrease key】to return to the self rectification display mode.
(3)Press【Increase key】in the self rectification ready mode to enter the self rectification operation mode
where,
Indicators are bright. The measured diameter flashes on the digital display. The feedback
control output is displayd on the LEB display. After self rectification has been completed, the system will
save automatically the result of rectification and return to the normal operation mode. At the same time, it
will turn on automatically diameter feedback control. Press【Decrease key】during self rectification to stop
the operation and return to the self rectification display mode.
“L―” in the above indication is the mark for wire travel length.
“―” in the above indication is the mark for rectified nominal diameter
“EU―” in the above indication is the mark for rated main machine given voltage.
┌────────┐
│Input system parameter password│
└────────┘
│
【Parameter key】│
┌───────────── ┤
│Wrong password │Correct password
↓ ↓
┌──────┐ ┌────────┐ 【Shift key】 ┌────────┐
│Normal operation
mode│ ←──── │Comm work mode display │←───→ │Comm work mode setting│
└──────┘【Parameter key】└────────┘ 【Parameter key】└────────┘
↑ ↑↓
│ ┌────────┐ 【Shift key】 ┌────────┐
<Note 1> ├←───────-│External comm mode display │←───→ │External comm mode setting│
│ 【Parameter key】└────────┘ 【Parameter key └────────┘
│ ↑↓
│ ┌────────┐ 【Shift key】 ┌────────┐
├←───────-│ Slave machine address display │←───→│ Slave machine address setting
│
│【Parameter key】└────────┘ 【Parameter key└────────┘
│ ↑↓
│ ┌────────┐ 【Shift key】 ┌────────┐
├←───────-│ Comm baud rate display │←───→│ Comm baud rate setting │
【Parameter key】 └────────┘ 【Parameter key】 └────────┘
│ ↑↓
│ ┌────────┐ 【Shift key】 ┌────────┐
├←───────-│ Data frame format display │←───→│ Data frame format setting │
【Parameter key】└────────┘ 【Parameter key】└────────┘
│ ↑↓
24
No2401,Jingchang Tech park, Suzhou city,JiangSu province,China
008618913191585 jerrypro@qq.com www.newleadgroup.com
│ ┌────────┐ 【Shift key】┌────────┐
<Note2> ├←───────- │Feedback work mode display│←───→ │Feedback work mode setting│
│【Parameter key】└────────┘ 【Parameter key】└────────┘
│ ↑↓
│ ┌────────┐ 【Shift key】 ┌────────┐
├←───────-│Feedback para password display│────→ │Feedback para password setting│
【Parameter key└────────┘ 【Parameter key】└────────┘
│ ↑↓
│ ┌────────┐ 【Shift key】 ┌────────┐
├←───────-│Tolerance setting type display│────→ │Tolerance setting type setting│
【Parameter key】└────────┘ 【Parameter key】└────────┘
│ ↑↓
│ ┌────────┐ 【Shift key】┌────────┐
<Note2> ├←───────- │Lump & neck limit type display│←───→│Lump & neck limit type setting│
│【Parameter key】└────────┘ 【Parameter key】└────────┘
│ ↑↓
│ ┌────────┐ 【Shift key】 ┌────────┐
<Note2> ├←───────-│Gauge measuring mode display│←───→ │Gauge measuring mode setting│
│【Parameter key】└────────┘ 【Parameter key】└────────┘
│ ↑↓
│ ┌────────┐ 【Shift key】 ┌────────┐
├←───────- │Data refresh rate display│←───→ │Data refresh rate setting│
│【Parameter key】 └────────┘ 【Parameter key】└────────┘
│ ↑↓
│ ┌────────┐ 【Shift key】┌────────┐
<Note2> ├←───────-│Display resolution display│←───→ │Display resolution setting│
│【Parameter key】└────────┘ 【Parameter key】└────────┘
│ ↑↓
│ ┌────────┐ 【Shift key】 ┌────────┐
<Note2> ├←───────-│ Data correction display │←───→ │ Data correction setting │
│ 【Parameter key】└────────┘ 【Parameter key】└────────┘
│ ↑↓
“Fdb” in the above indication is the mark for feedback work mode.
Setting procedures: See 4.3.1.
“F” in the above indication is the mark for feedback parameter password.
Setting procedures: See 4.3.1.
““LUP”” in the above indication is the mark for setting type of lump & neck detection limit.
Setting procedures: See 4.3.1.
27
No2401,Jingchang Tech park, Suzhou city,JiangSu province,China
008618913191585 jerrypro@qq.com www.newleadgroup.com
4.3.7 Gauge measuring mode
Application:This parameter is used to determine the work mode of gauge measurement. The setting
depends on the Gauge configuration. Only when the Gauge has the function of measuring transparent body
can the parameter be set at 11.
Numeric area:10=Normal measuring mode,11=Transparent body measuring mode.
Display format:Suppose the pre-set measuring mode is 10(normal measuring mode),the corresponding
indication will be as follows::
“NN” in the above indication is the mark for gauge measuring mode.
Setting procedures: See 4.3.1.
“dr” in the above indication is the mark for display data refresh rate.
Setting procedures:In order to set the display data refresh rate at 10 indication/s,proceed as follows::
(1)Input the correct system parameter password (see 4.1.10). Press 【Parameter key】to confirm the
input and enter the system parameter menu.
(2)Press【Increase key】or【Decrease key】to locate the parameter display data refresh rate.
(3)Press【Shift key】to enter the parameter setting mode. The last two digits “2.5” flash.
(4)Press【Increase key】3 times to change “2.5” into“10”.
(5)Press【Parameter key】to save the change and return to the parameter display mode.
(6)If it is necessary to set another system parameter,press【Increase key】or【Decrease key】to locate
the parameter. Otherwise press【Parameter key】to return to the normal operation mode.
28
The indicator is bright.
No2401,Jingchang Tech park, Suzhou city,JiangSu province,China
008618913191585 jerrypro@qq.com www.newleadgroup.com
“ddu” in the above indication is the mark for display resolution.
Setting procedures: See 4.3.1.
“dc” in the above indication is the mark for display data correction.
Setting procedures:In order to change the original display data correction “0” into “-12”,proceed as
follows::
(1)Input the correct system parameter password (see 4.1.10). Press 【Parameter key】to confirm the
input and enter the system parameter menu.
(2)Press【Increase key】or【Decrease key】to locate the parameter display data correction.
(3)If the setting is allowed,press 【Shift key】 to enter the parameter setting mode. The third digit “0”
flashes.
(4)Press【Decrease key】to change “0” into “-”.(if the original digit is “-”,press 【Increase key】
to change “-” into “0”).
(5)Press【Shift key】, the fourth digit “0” flashes. Press【Increase key】once to change “0” into “1”.
(6)Press【Shift key】,the fifth digit “0” flashes. Press【Increase key】twice to change “0” into “2”.
(7)Press【Parameter key】to save the change and return to the parameter display mode.
(8)If it is necessary to set another system parameter,press【Increase key】or【Decrease key】to locate
the parameter. Otherwise press【Parameter key】to return to the normal operation mode.
dbr” in the above indication is the mark for digital display brightness.
“u ” in the above indication is the mark for software/hardware version number of the Gauge.
“AL” in the above indication is the mark for alarm output configuration.
Setting procedures: See 4.3.1.
(1)5-digit LED digital display is used to display the measured diameter or fault message.
In normal operation, the measured diameter is displayd, which is equal to that displayd on the panel of
the Gauge
When the Gauge is faulty, the fault message is displayd, which is equal to that displayd on the panel of
the Gauge. For details, see 3.6.
When the communication with the Gauge is abnormal, the following is displayed:
31
No2401,Jingchang Tech park, Suzhou city,JiangSu province,China
008618913191585 jerrypro@qq.com www.newleadgroup.com
(2)10-segment LEB (light-emitting bar) display is used to display the diameter feedback control
output.
When all the 10 segments are dark, the diameter feedback control is turned off.
When the central two segments are bright, the diameter feedback control is turned on but the output is
very small(near 0).
Beginning from the midpoint, when the segment(s) to the left is(are) bright, the diameter feedback
control output is negative; when the segment(s) to the right is(are) bright, the diameter feedback control
output is positive. The more number of segments are bright, the greater the output will be. When feedback
control output is saturated, the 5 segments on the left flash (indicating saturation in the negative direction)
or the 5 segments on the right flash (indicating saturation in the positive direction).
All the 10 segments flash simultaneously indicates abnormal operation of the Gauge or feedback control
parameter error.
(3)AL indicator (red):A bright indicator indicates that the alarm relay acted and thus the alarm contacts
are closed. A dark indicator indicates that the alarm relay did not act and thus the alarm contacts are open.
(4)CM indicator (green):A bright indicator indicates that the external control switch is open, enabling
feedback control. A dark indicator indicates that the external control switch is closed, disabling feedback
control.
9 10 11 12 13 14 15 16
1 2 3 4 5 6 7 8
L N AL1 AL2 SG SA SB SR
Figure 5-2 Terminal arrangement(back view)
32
No2401,Jingchang Tech park, Suzhou city,JiangSu province,China
008618913191585 jerrypro@qq.com www.newleadgroup.com
Termminal No. Name Description
──────────────────────────────────────
1 L Phase wire of power supply(220VAC)
2 N Neutral of power supply(220VAC)
3 AL1 Alarm contact output(the internal realy contacts are closed at alarm)
4 AL2 Alarm contact output (AL1 is connected to AL2 at alarm)
5 SG RS-485 comm interface:Signal ground
6 SA RS-485 comm interface:Bus A
7 SB RS-485 comm interface:Bus B
8 SR RS-485 comm interface:Terminal to connect the resistance for termination
impedance match
9 ─ Not used
10 K1 Signal to disable diameter feedback control(feedback control is disabled
when K1 is connected to K2,)
11 K2 Signal to disable diameter feedback control
12 10V -10V, 5mA voltage output(used for the basic mode of feedback control)
13 VIN Given voltage input(signal end:-10V~+10V)
14 GIN Given voltage input(ground end:0V)
15 GOT Control voltage output(ground end:0V)
16 VOT Control voltage output(signal end:-10V~+10V)
──────────────────────────────────────
5.1.4 Mounting and wiring
DSP-3A Monitor employs a 48 mm×96 mm standard instrument chassis. In order to mount the monitor, a
44 mm(h)×92 mm(w)rectangular hole shall be cut on the control cabinet panel. Then the monitor shall
be inserted into the hole from the front and fixed on the cabinet panel with the enclosed screws.
.
33
No2401,Jingchang Tech park, Suzhou city,JiangSu province,China
008618913191585 jerrypro@qq.com www.newleadgroup.com
Figure 5-4 Wiring diagram 1:Only diameter display
34
No2401,Jingchang Tech park, Suzhou city,JiangSu province,China
008618913191585 jerrypro@qq.com www.newleadgroup.com
Figure 5-6 Wiring diagram 3: Basic mode of feedback control
Wiring discription:
(1)Connect pin ① and ② at the communication interface of the Diameter Gauge to the terminal 7 and 6
of DSP-3A Monitor respectively using a twisted pair having copper conductor size not samller than 0.5
mm2 and characteristic impedance of 120 Ω.
(2)The signal ground(pin ── terminal 5)may be the shield of the twisted pair or another wire. The
signal ground may be omitted with short bus length (up to 50m) and weak field interference.
(3)If DSP-3A Monitor is the last peripheral equipment on the RS-485 communication bus, terminal 7
shall be connected to terminal 8(connection of the resistance for termination impedance match).
(4)The external alarm may be alarm lamp, buzzer or electric bell with operating voltage of 220VAC.
(5)Terminal 10 and 11 of the Monitor are used to turn on/off diameter feedback control in the automatic
mode(see 4.2.3): When they are disconnected, feedback control is enabled. When they are connected,
feedback control is disabled. Generally, they are connected to the normally closed auxiliary contacts of the
contactor in the main circuit of the motor under control or to the feedback control switch on the control
cabinet panel.
(6)Terminal 12, 13 and 14 of the Monitor shall be connected to a potentiometer for adjusting the
feedback control output amplitude. DSP-3A Monitor has a dedicated potentiometer in its accessories,
which may be connected to these terminals.
(7)Terminal 15 and 16 of the Monitor are for feedback control output. They shall be connected in series
to the high end of the motor speed regulating potentiometer(i.e., the end where the max given voltage is
present). The procedures are as follows: Locate the high end of the speed regulating potentiometer. Cut
off the wire connected to this end to produce two cut ends A and B. If the feedback signal is to control
the extruder, end A shall be connected to terminal 15 and end B to terminal16. If the feedback signal is
to control the capstan, end A shall be connected to terminal 16 and end B to terminal 15.
(1)The integral coefficient is the first two digits of the the parameter. Effective numeric area: 01~30.
The integral coefficient determines the speed at which to eliminate the diameter deviation during the
feedback control process. The greater the coefficient is, the faster the diameter deviation will be eliminated.
But too fast elimination of the diameter deviation will result in unsteady system. Conversely, the smaller
the coefficient is, the slower the diameter deviation will be eliminated and the steadier the system will be.
For this reason, the value of the integral coefficient shall be selected considering both speed and stability.
Generally, the integral coefficient can be determined by the following procedures:
Suppose the line speed during normal operation V(m/min)= V/60(m/s)and the wire travel length from the
extruder head to the Gauge is L(m),then the time it takes for the wire to travel from the extruder head to
the Gauge T = 60×L÷V(s).
Therefore,
Integral coefficient = 30÷(2×T+1)= 30÷(120×L÷V +1)
This is the theoretic value of the integral coefficient. In practical application, this value must be modified
appropriately based on the commissioning.
【Example 1】The line speed V=600m/min. The diameter gauge is mounted after the capstan. The length of
the cooling trough is 6m. The length of the wire wound on the capstan wheel is 8m. Then the wire travel
length L=6+8=14m. 36
No2401,Jingchang Tech park, Suzhou city,JiangSu province,China
008618913191585 jerrypro@qq.com www.newleadgroup.com
Therefore,
Integral coefficient = 30÷(120×L÷V +1)= 30÷(120×14÷600 +1)=7.9
The integral coefficient after rounding=8.
【Example 2】 The line speed V=100 m/min. The diameter gauge is mounted before the cooling trough
and 0.5m from the extruder head. Then the wire travel length L=0.5m.
Therefore,
Integral coefficient = 30÷(120×L÷V +1)= 30÷(120×0.5÷100 +1)=18.75
The integral coefficient after rounding=19
(2)The Proportional coefficient is the last two digits of the the parameter. Effective numeric area: 01~
25.
The proportional coefficient determines the size of the proportional in the feedback control output. Its
value can be calculated using the following equition:
Proportional coefficient = 25×(D2 — d2)÷ D2
Where,
D=Insulation diameter,d=Conductor diameter before extrusion. In practical application, this value
must be modified appropriately based on the commissioning.
【Example 3】Suppose the conductor diameter d=1.5 mm and the insulation diameter D=2.2 mm,then
Proportional coefficient = 25×(2.22 — 1.52)÷ 2.22 = 13.4
The proportional coefficient after rounding=13
5.2.5 Commissioning
After the Gauge and Monitor have been mounted and the wiring has been completed, commission the
feedback control system with the following procedures:
(1)Set the related parameters according to 5.2.1—5.2.4. Be sure to set the feedback control work mode at
manual mode during the commissioning.
(2) Take a sample wire having diameter slightly larger than the nominal(For example, if the nominal is
set at 2mm,take a sample wire having diameter of 2.1~2.4mm). Start the line and make it run at low
speed. Mount the above sample wire on the guide pulley of the Gauge. Press【Increase key】to turn on
feedback control.
(3)Observe the line operation. If the feedback control system controls the extruder, the screw shall turn at
a lower speed. If the feedback control system controls the capstan, the capstan wheel shall turn at a higher
speed. If the observed speed variation is contrary to the above mentioned, exchange the two wires
connected to Terminal 15 and 16 of the Monitor.
(4)Press 【Decrease key】to turn off feedback control. Start the line and make it run at normal speed until
the wire diameter becomes stable and slightly larger37than the set nominal. Press【Increase key】to turn on
No2401,Jingchang Tech park, Suzhou city,JiangSu province,China
008618913191585 jerrypro@qq.com www.newleadgroup.com
diameter feedback control. Observe the variation of wire diameter.
(A)If the wire diameter approaches the set nomial fast and steadily without obvious fluctuation, the
commissioing is finished.
(B)If the wire diameter approaches the set nomial slowly taking a long time, increase the proportional
coefficient.
(C)If the wire diameter fluctuates sharply without reaching a steady value, decrease the proportional
coefficient.
Adjust the proportional coefficient with the a.m. method to achieve a good feedback control effect.(If good
effect can not be achieved by adjusting the proportional coefficient, adjust appropriately the the integral
coefficient)
(5)After commissioning, set the feedback control work mode at auto mode if necessary.
38
No2401,Jingchang Tech park, Suzhou city,JiangSu province,China
008618913191585 jerrypro@qq.com www.newleadgroup.com
(3)Input the system parameter password “74683”. The exact procedures are as follows:
Press 【Shift key】,the first “―” from the left on the digital display becomes a flashing “0”. Press
【Increase key】 or 【Decrease key】 to change “0” into “7”. Press 【Shift key】again,the first digit
indicates “7” while the second “―” becomes a flashing“0”. Press【Increase key】or【Decrease key】to
change “0” into “4”. Change the remaining three “―”’s into the required number in the same way and
press【Parameter key】.
(4)The system enters the system parameter display mode, where the first displayd parameter is the
communication work mode:
The first two digits indicating “C―” on the above indication are the mark for the communication work
mode. The last three digits indicate the corresponding parameter value. “Con” stands for the peripheral
equipment interface mode while “rtu” stands for the Modbus RTU protocol mode.
(5)In order to change the communication work mode,press 【Shift key】to enter the system parameter
setting mode. At this time the last three digits flash. Press【Increase key】or【Decrease key】to change the
value:Press【Increase key】 to change the original “Con” into “rtu”. Conversely, press【Decrease key】
to change the original “rtu” into “Con”.
(6)After the change has been made,press 【Parameter key】 to save the change and return to the system
parameter display mode.
(7) If it is not necessary to change another parameter,press【Parameter key】once more to return to the
normal operation mode.
(8) If it is necessary to change another parameter, press【Increase key】or【Decrease key】in the system
parameter display mode to locate the parameter to be changed. Then press 【Shift key】to enter the system
parameter setting mode to make the change.
The first two digits in the above indication “CA” is the mark for slave machine address. The last two digits
“01” are the corresponding parameter value.
(3)Press 【Shift key】to enter the system parameter setting mode. At this time, the third digit “0” flashes.
Press【Increase key】or【Decrease key】to change its value.
(4)After the change has been made, press【Shift key】,the fourh digit “1” flashes. Press【Increase key】
or【Decrease key】to change its value. 39
No2401,Jingchang Tech park, Suzhou city,JiangSu province,China
008618913191585 jerrypro@qq.com www.newleadgroup.com
(5) After the change has been made,press 【Parameter key】to save the change and return to the system
parameter display mode.
(6) If it is not necessary to change another parameter,press【Parameter key】once more to return to the
normal operation mode.
(7) If it is necessary to change another parameter, press【Increase key】or【Decrease key】in the system
parameter display mode to locate the parameter to be changed. Then press【Shift key】to enter the system
parameter setting mode to make the change.
The first two digits in the above indication “Cb” is the mark for communication baud rate. The last three
digits “19.2” are the corresponding parameter value.
(3)Press 【Shift key】to enter the system parameter setting mode. At this time, the last three digits “19.2”
flash simultaneously. Press【Increase key】or【Decrease key】to change its value.
(4)After the change has been made,press【Parameter key】to save the change and return to the system
parameter display mode.
(5) If it is not necessary to change another parameter,press【Parameter key】 once more to return to the
normal operation mode.
(6) If it is necessary to change another parameter, press【Increase key】or【Decrease key】in the system
parameter display mode to locate the parameter to be changed. Then press 【Shift key】to enter the system
parameter setting mode to make the change.
The first two digits in the above indication “CC” is the mark for communication data bit and parity check
systeme. The last three digits “E81” are the corresponding parameter value.
(3)Press 【Shift key】to enter the system parameter40setting mode. At this time, the last three digits “E81”
No2401,Jingchang Tech park, Suzhou city,JiangSu province,China
008618913191585 jerrypro@qq.com www.newleadgroup.com
flash simultaneously. Press 【Increase key】or【Decrease key】to change the value. The Modbus RTU
protocol allows three options as follows: E81(8 data bits, 1 stop bit and even parity check), o81(8 data bits,
1 stop bit and odd parity check)and N82(8 data bits, 2 stop bits and no parity check).
(4)After the change has been made,press【Parameter key】to save the change and return to the system
parameter display mode.
(5) If it is not necessary to change another parameter,press【Parameter key】once more to return to the
normal operation mode.
(6) If it is necessary to change another parameter, press【Increase key】or【Decrease key】in the system
parameter display mode to locate the parameter to be changed. Then press【Shift key】to enter the system
parameter setting mode to make the change.
Note:
(1)End A and B of each equipment shall be connected using a twisted pair having copper conductor size
not samller than 0.5 mm2 and characteristic impedance of 120 Ω.
(2)The signal ground(wire G)may be the shield of the twisted pair or another wire. The signal ground
may be omitted with short bus length (up to 50m) and weak field interference.
(3)The last peripheral equipment on the bus (peripheral equipment 5 in the above Figure) must be
connected to a resistance for termination impedance match. Each peripheral equipment has in its interior
this resistance. The only thing to do is to connect it to the related terminal according to the operating
directions. Except for the last peripheral equipment, no other peripheral equipment on the bus shall be
connected to the resistance for termination impedance match.
If normal communication is not possible between the Gauge and peripheral equipment when they are
properly connected, check if the system parameter communication work mode is set at “Con”. For details,
see 6.1.1. 41
No2401,Jingchang Tech park, Suzhou city,JiangSu province,China
008618913191585 jerrypro@qq.com www.newleadgroup.com
6.2.1 Commonly used peripheral equipment
The peripheral equipment produced or being developed by Shanghai Online includes the following:
(1) DSP-3A Monitor, for remote display of the measured diameter and implementation of diameter
feedback control.
(2)DSP-3S/DSP-3D large remote display(single /double side display), in which large LED digitron is
used to display the measured diameter for ease of monitoring
(3)COM-3S serial communication adapter.
The first two digits in the above indication “C—” is the mark for external communication (adapter work)
mode. This parameter is set in a similar way as that for the communication work mode in 6.1.1. But it has
no Con(peripheral equipment interface)mode.
42
No2401,Jingchang Tech park, Suzhou city,JiangSu province,China
008618913191585 jerrypro@qq.com www.newleadgroup.com
6.3 Modbus RTU mode
6.3.1 General description of the protocol
The data communication by DDM-3020 Diameter Gauge employs the Modbus serial link protocol. It is a
master/slave protocol. The diameter gauge as a slave equipment can only accept the request and command
by the master equipment(e.g., industry computer, PLC etc)and make response. At one time, only one
master point (also called master machine) and one or more slave points (also called slave machine,max
number 247 ) are connected to the same serial bus. Modbus communication is always initiated by the
master point. A slave point will not send out data until it receives a request from the master point. A slave
point will never communicate with another slave point. The master point will initiate only one Modbus
transaction at one time.
Note 1: For short communication distance(≤ 50m),the signal ground may be not connected.
Note 2: The communication interface of the Gauge can provide a DC power supply of 15V 50mA to the
outside to be used as a small capacity power supply for isolater-converter etc. When this kind of power
supply is used, short circuit and overload shall be avoided to protect the power module in the Gauge.
Note 3: As DDM-3020 Diameter Gauge is provided with a 120Ω resistance for termination impedance
match and polarity bias circuit inside the communication interface, it must be used as a termination of the
RS-485 bus. The other end of the bus shall be also connected to a 120Ω resistance for termination
impedance match.
Note 2: Indicating the current work mode of the Gauge. The binary bits have the meaning as follows:
Bit 0=1:Absence of tested object Bit 1:(Reserved)
Bit 2=1:Tested object too high Bit 3=1:Tested object too low
Bit 4=1:Multiple wires Bit 5=1:Lens badly polluted
Bit 6=1:Inteference by ambient stray light Bit 7=1:Absence of measuring light
Bit 8=1:Gauge locked(over 31 inputs of wrong password).
Bit 9=1:Software fault Bit 10=1:Hardware fault
Bit 11=1:Internal system fault Bit 12=1:Panel commuincation fault
Bit 15-13:Reserved
Note 3: Indicating the current alarm mode of the Gauge. The binary bits have the meaning as follows:
Bit 0=1:Alarm for too thick tested wire Bit 1=1:Alarm for too thin tested wire
Bit 2=1:Lump & neck defects detected during the current work cycle(100ms)
Bit 7-3:Reserved
Bit 8=1:Too thick alarm(hold) Bit 9=1:Too thin alarm(hold)
Bit 10=1:Lump & neck alarm(hold) Bit 11-14:Reserved
Bit 15: External alarm contacts output(0=open,1=closed).
48
No2401,Jingchang Tech park, Suzhou city,JiangSu province,China
008618913191585 jerrypro@qq.com www.newleadgroup.com
Note 4 Indicating the operating mode of the feedback control system. The binary bits have the meaning
as follows:
Bit 1-0: Feedback operating mode(00=turn-off,01=self rectification,10=frozen,11=turn-on)
Bit 2=1:Positive output saturated Bit 3=1:Negative output saturated
Bit 6=0: Manual work mode, Bit 6=1: Auto work mode
Bit 7=1:Feedback control parameter error
Note 10: Used to set the behavour of the external alarm contacts. The binary bits have the meaning as
follows:
Bit 0:Diameter out-of-positive-tolerance alarm
Bit 1:Diameter out-of-negative-tolerance alarm
Bit 2:Lump & neck alarm(hold, manual re-set needed)
Bit 3:Reserved
Bit 4:Abnormal operation by the Gauge
Bit 5:Abnormal feedback control(output saturation and feedback control parameter error)
Bit 6:Absence of tested object
Bit 7:Diameter out-of-tolerance alarm(hold, manual re-set needed)
Bit 15-8: Reserved
When a binary bit=1 and the abnormalury represented by it is detected by the Gauge, the external
output alarm contacts will be closed. When a binary bit=0, the abnormalury represented by it will be
ignored by the Gauge.