Qctech A Software: Operation Manual
Qctech A Software: Operation Manual
Qctech A Software: Operation Manual
QCTech A Software
Operation Manual
Index
Charper 1 Install Software 3
1-1Computer
1-2 Install
1-3 Warning
Charper 2 Program 6
2-1 Start
2-2 Manual
2-3 Tools
2-4 Condition
2-5 Curve
1
OPERATION MANUAL
2-6 Table
2-7 Update
2-8Controlling Button
Charper 3 Function Manual 11
3-1 File
3-2 Edit
3-3 View
3-4 Test
3-5 Data
3-6 Hardware
3-7 Tools
1. CPU:PentiumII 233
2. RAM :256MB
3. VGA :At least 800 x 600 full color
4. HardDisk:Software 20MB. Suggestion above 20G Byte
5. CD ROM:Above 40X for installing the software
6. System:Window 98、Window 2000、Window NT、Window XP
7. Others:Monitor,Keyboard, Mouse,Printer,Floppy
2
OPERATION MANUAL
1-2 Install
Put the QCTech CD into the CD ROM, choose manual “START” / “RUN”. Open “\QC Setup.exe
” . For example, if the CD ROM is on D Disk, key in D:\QCSetup.exe. Press “Yes” to start
installing. Follow up the wizard process as below:
1. Figure 1-1, press [Next]
Figure 1-1
Figure1-2
3. Figure1-3
3.1. Brower:can choose the address for the software
3
OPERATION MANUAL
3.2. Next
3.3. Back
3.4. Exit
Figure 1-3
Figure 1-3
4. Press Install, Finish. See Figure 1-4
5. Figure 1-5, 1-6 press [Yes] or [OK] to complete the installation
Figure 1-4
Figure 1-4
4
OPERATION MANUAL
Figure 1-5
Figure 1-6
1-3 Warning
1. Adjust the window on 800×600
2. Don’t use any Screen Saver program
3. Turn off every saving-power system including System, Monitor and Hard Disc incase any
dangerous situation.
Charpter 2 Program
2-1 Start
It will need to key in password when enter QCTechA. See Figure 2-1. Usually, this will be
“qctech” when shipped. Password can be changed to number or letter. It’s the same of capital or
character.
Password
Yes
Password
No
Figure 2-1 Password
Manual Update
Tools
5
OPERATION MANUAL
Curve
Controlling
Button
2-2 Manual
1. File New
Open…
Save
Save As…
Import File
Export Export Test
Data…
Export
Result
Table…
Exprot
Curve…
6
OPERATION MANUAL
Print
Print Preview
Exit
2. Edit Delete
Undo
3. View Multi Curve
Language English
Taiwan
4. Test Method…
Return…
Preload…
Stop…
Materials…
5. Data Unit
Display
Curve
Table
Report
6.Hardware Calibration…
Communication…
Machine…
Loadcell…
Extensometer…
7. Tools Password…
Dictionary…
Load setting…
Save setting…
8. Help About QCTech A
2-3 Tools
1. :New
2. :Open
3. :Save
4. :Print
5. :Multi
6. :English
7
OPERATION MANUAL
7. :Taiwan
8. :Method
9. :Return
10. :Preload
11. :Stop
12. :Materials
13. :Unit
14. :Display
15. :Curve
16. :Table
17. :Report
2-4 Condition
Figure 2-3 Show the current condition information including X coordinate, Y coordinate, testing
type and Speed.
Test Test
Figure 2-3 Type Speed
2-5 Curve
Data is from testing result as below:
1. Update testing process result.
2. Not under test process and [Multi Curve] is not under selected, there will show the marked
testing result.
3. Not under test process and [Multi Curve] is under selected, there will show the testing result
which has marked「*」. If there is no testing result being marked「*」,there will show the lateset
test.
2-6 Table
Show testing result. See Figure 2-4
8
OPERATION MANUAL
2-7 Update
Testing update information, max 5 sets. Every of them have three parts as Figure 2-5. Select
from [Data]→「Display」.
1. :Controll the direction up of cross-head. Speed from slow to fast. Releaseing this button the
2. :Controll the direction down of cross-head. Speed from slow to fast. Releaseing this button
9
OPERATION MANUAL
6. :Start test
3-1 File
[File] function is almost the same as other Microsoft program
10
OPERATION MANUAL
7. [Export Result Table]:Can transfer the testing data to Excel file. Select from [Export] →[Export
Result Table] and save with a name.
8. [Export Curve]:Transfer testing curve to .bmp. Select from [Export] →[Export Curve] and save
with a name.
9. [Print]
10. [Print Preview]
11. [Exit]:Close QCTech program
3-2 Edit
For deleteing testing result or call back the deleteing result.
1. [Delete]:Select the data to delete.
2. [Undo]:Call back the deleteing data. Max previous 5 sets
3-3 View
1. [Multi Curve]:Please see 2-5 Curve and Figure 3-1,3-2
2. [Language]:English/Taiwan
11
OPERATION MANUAL
3-4 Test
1. [Method]:Including Item, Material , Speed, Method, Start, Exit…..etd.. See Figure 3-3
12
OPERATION MANUAL
Tensile:Tensileing test
Compression:Compression test
Peel:Adhesion test
Tear:Tearing test
Shear:Shearing test。
3pt Flexture:Fix two point of the material ,and compress the pressure on the
middle. The testing length can be setted by [settings…]. See figure 3-5.
3. [Preload]:Read the value above this preload when test. See figure 3-8.
16
OPERATION MANUAL
3-5 Data
1. [Unit]:See Figure 3-10.
2. [Data Display]:Select the update information (Figure 2-2 QCTech A Main Screen). See
Figure 3-11 Display.
18
OPERATION MANUAL
3. [Table]:Setup the Table information (Figure 2-2 QCTech A Main Screen).See Figure 3-13.
4. [Report]:Setup the form for printing. See Figure 3-14 and preview Figure 3-15
19
OPERATION MANUAL
20
OPERATION MANUAL
3-6 Hardware
Including Calibration, Communication, Machine, Loadcell and Extensometer. There will need
to key in password first.
1. [Calibration] →[Loadcell]:Loadcell is a sensitive voltage signal part , and the relation between
voltage and load is as Figure 3-16 . Voltage and load isn’t a linear relation. For better correction,
separate the force unit to 4 parts to calibrate and compute the parameter in formula. The
formula is combined with several formulas. For better correction, the calibration should be start
with zero to force. Force should be closed symmetry and be calibrated. Please use the same
parameter range of force if it can’t work. See Figure 3-17.
1.1. [Loadcell]:Select a loadcell to calibrate
1.2. [Force]:update force value
1.3. [Parameter]
1.4. [Zero]:Zeroize the force value
1.5. :Controlling the cross-head
21
OPERATION MANUAL
1.6. Method:
1.6.1. Press [Zero]. Put some pressure on the loadcell with a tool. Adjust the parameter by
adjusting button key in the right pressure.
1.6.2. No load under loadcell. Repeat the step except press zero.
1.6.3. For more correct calibration, adjust several load rang step as 1.6.1. The best step is
from zero to other range and the middle of them.
1.6.4. Positive number parameter could be the same as negative, so if the calibration isn’t
done in both number, you may key in the same parameter.
Force
Calibration Value
Actual Value
Votage
3-7 Tools
1. [Password]:For entering the software. See Figure 3-22
24
OPERATION MANUAL
25