MICRO SWITCH Flame-Proof Limit Switches: GXS Series
MICRO SWITCH Flame-Proof Limit Switches: GXS Series
MICRO SWITCH Flame-Proof Limit Switches: GXS Series
1180
FEATURES
• II 2 G Ex d IIC T6, II 2 D Ex tD A21 IP66 T85°C
• KEMA 00 ATEX 2103 X, IEC Ex KEM 10.0039X
• Conforms to EN60079-0, EN60079-1, EN61241-0,
EN61241-1
• CE marked
GXA • EN50041 mounting compatible (GXA Series)
Series GXE
Series • EN50047 mounting compatible (GXE Series)
• Rugged zinc die-cast housing with epoxy coating
• Pre-wired, 5 m of cable
DESCRIPTION • Bottom exit cable ONLY
The GXS Series flame-proof limit switches are designed • Double insulated switch element with snap-action
specifically for use in hazardous applications. The GXS basic switch
enclosure is epoxy sealed and has an environmental
protection of IP66 as per IEC/EN 60529. The entire GXS Series Category Flammable Protection Requirements
complies with the European Directive on Equipment and atmospheres required for equipment
Protective Systems Intended for Use in Potentially Explosive 2 Medium risk High Equipment is ca-
Atmospheres (94/9/EC) commonly referred to as the ATEX of an explosive pable of operat-
atmosphere ing safely under
Directive.
occurring a single fault
Gas = Zone 1 condition (ib) or
VALUE TO CUSTOMERS Dust = Zone 21 alternatively, one
• Flameproof protection or more types
• Meets product design and quality systems requirements of of protection is
ATEX 94/9/EC used.
For example, ‘d’,
• Standard European mounting of 30 mm x 60 mm (GXA
‘e’, ‘p’, etc.
Series) or 20 mm to 22 mm (GXE Series)
3 Low risk of Normal Equipment
• Suitable for difficult operating environments
an explosive for safe use in
• Fast and easy to install atmosphere normal operation,
• Epoxy-sealed cable and basic switch in a limit switch body occurring typically (Ex n)
• External earth connection not required Gas = Zone 2 equipment
• Change over (SPDT), 3 wire device, 1NC/1NO Dust = Zone 22
Table 1. Specifications
Characteristic Parameter
Mechanical life up to 2 million operations
Degree of protection IP66, EN 60529
Operating temperature @ 3 A -20 °C to 75 °C [-4 °F to 167 °F]
Operating temperature @ 4 A -20 °C to 60 °C [-4 °F to 140 °F]
EN60079-0, EN60079-1, EN61241-0, EN61241-1
II 2 G Ex d IIC T6, II 2 D Ex tD A21 IP66 T85°C
Standards/approvals
KEMA 00 ATEX 2103 X; IEC Ex KEM10.0039X, NEPSI Ex
(X indicates special conditions for safe use, see certificates for details)
AC15, DC13
1NC/1NO change over contacts
Electrical rating
Double insulated switch element
No internal or external earth connection
Contact material silver
Harmonised Cenelec cable, HO5VV-F, 3-core x 0,75 mm2
Black (BK) - common
Cable/body Grey (GY) - NC
Brown (BN) - NO
Epoxy-sealed cable and body
Shock 50 g, IEC 60068-2-27
Vibration 10 g, IEC 60068-2-6
GXA # 1 A A 3
or
GXE
Actuator Side Lever Head
Switch Type Cable Length Circuitry Type Roller Material Orientation
GXA Series Silver contacts, Side rotary, Lever to front or
Hazardous 5 5 meter cable 1 snap action A1 fixed roller lever A Plastic plunger parallel
to mtg surface
Area Side rotary,
A2 adjustable B Steel 3 Lever to right
Limit Switch roller lever
Side rotary,
Hazardous
B Pin plunger 5 Lever to rear
Area
Roller plunger
Limit Switch
C Roller plunger 6 perpendicular to
mtg surface
D Roller arm
2 sensing.honeywell.com
MICRO SWITCH Flame-Proof Limit Switches, GXS Series
Operate Force or
Operate Point
Torque [max.]
Total Travel
Differential
Catalog Descrip-
Actuator Type
Pretravel
Listing tion
Position
Travel
Free
Bar Chart
0° 29° 85°
Side rotary with fixed 38,1 mm FP OP TT
0,33 Nm Black-Gray (NC) >
GXA51A1B [1.50 in] lever & Ø19 mm x 6,4 mm Black-Brown (NO) < 0° ref. 29° 29° 85° 7°
[2.9 in lb]
[Ø0.75 in x 0.25 in] steel roller 7° DT
Operate Force or
Operate Point
Torque [max.]
Total Travel
Differential
Catalog Descrip-
Actuator Type
Pretravel
Listing tion
Position
Travel
Free
Bar Chart
0° 26° 75°
Side rotary with fixed 46,5 mm 0,25 Nm FP OP TT
Black-Gray (NC) >
GXE51A1A [1.83 in] lever & Ø19 mm x 6,0 mm [2.21 Black-Brown (NO) < 0° ref. 26° 26° 75° 8°
[Ø0.75 in x 0.24 in] nylon roller in-lb] 8° DT
0° 26° 75°
Side rotary with fixed 46,5 mm 0,25 Nm FP OP TT
Black-Gray (NC) >
GXE51A1B [1.83 in] lever & Ø19 mm x 6,0 mm [2.21 Black-Brown (NO) < 0° ref. 26° 26° 75° 8°
[Ø0.75 in x 0.24 in] steel roller in-lb] 8° DT
4 sensing.honeywell.com
MICRO SWITCH Flame-Proof Limit Switches, GXS Series
70,0
[2.75] 38,1
[1.50]
102,9
[4.05]
75,0 60,0
[2.95] [2.36]
30,0 [1.18]
42,0 [1.65]
Figure 3. GXA Series Side Rotary Figure 4. GXA Series Pin Plunger Figure 5. GXA Series Roller Plunger
Adjustable Dimensions Dimensions Dimensions
(refer to Figure 2 for additional (refer to Figure 2 for additional (refer to Figure 2 for additional
measurements) measurements) measurements)
Ø19,1 mm Plunger Roller
[Ø0.75 in] diameter diameter
10,0 mm Ø12,4 mm
[0.39 in] [Ø0.49 in] 48,0 mm
[1.89 in]
35,0 mm 30,5 mm 43,5 mm
[1.38 in] [1.20 in] [1.71 in]
38,1 mm to 91,5 mm
[1.5 in to 3.60 in]
Adjustment
20 mm
[0.79 in]
46,6
60,0 [1.83]
13,8 [2.36]
3,0
[0.54] [0.12]
28 2X conduit plug
[1.10]
4,0 (supplied unfitted)
[0.16]
52,0 [2.05] 2,5 [0.10] 30,0 [1.18]
57,0 [2.24]
65,0 [2.56]
Figure 8. GXE Series Side Rotary Figure 9. GXE Series Roller Plunger Figure 10. GXE Series Roller Lever
Adjustable Dimensions mm [in] Dimensions mm [in] Dimensions mm [in]
(refer to Figure 6 for additional (refer to Figure 6 for additional (refer to Figure 6 for additional
measurements) measurements) measurements)
42,0 42,0 42,0
40,0
[1.65] [1.65] 40,0 [1.65] 40,0
[1.57]
22,0 22,0 [1.57] 22,0 [1.57]
20,0 [0.79] [0.87] [0.87] [0.87]
20,0 20,0
Ø12,4 [0.79] Ø12,4 [0.79]
Ø19,1 [Ø0.49] [Ø0.49]
[Ø0.75]
39,5
70° 70° 3,0 [1.56]
3,0
min. min. [0.12]
[0.12]
34,0 to 79,0
[1.34 to
3.11]
3,0
[0.12]
15,0
[0.59]
6 sensing.honeywell.com
ADDITIONAL MATERIALS
m WARNING
PERSONAL INJURY
The following associated literature is available at
DO NOT USE these products as safety or emergency stop
sensing.honeywell.com: devices or in any other application where failure of the
• Product range guide product could result in personal injury.
• Product application-specific information Failure to comply with these instructions could result in
– Guide to Hazardous Location Approvals: MICRO SWITCH death or serious injury.
Hazardous Area Limit Switches
– MICRO SWITCH Hazardous Area Limit Switches brochure m WARNING
MISUSE OF DOCUMENTATION
• The information presented in this product sheet is for
reference only. Do not use this document as a product
installation guide.
• Complete installation, operation, and maintenance
information is provided in the instructions supplied with
each product.
Failure to comply with these instructions could result in
death or serious injury.
Warranty/Remedy
Honeywell warrants goods of its manufacture as being free
of defective materials and faulty workmanship. Honeywell’s
standard product warranty applies unless agreed to
otherwise by Honeywell in writing; please refer to your order
acknowledgement or consult your local sales office for specific
warranty details. If warranted goods are returned to Honeywell
during the period of coverage, Honeywell will repair or replace,
at its option, without charge those items it finds defective.
The foregoing is buyer’s sole remedy and is in lieu of all
other warranties, expressed or implied, including those of
merchantability and fitness for a particular purpose. In no
event shall Honeywell be liable for consequential, special,
or indirect damages.
Authorized Distributor
Honeywell:
GXE51A1B GXE51B GXE51C GXA51A1B GXA51A2B GXA51C GXE51A4J GXE51A2B GXA51B GXE51D