Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

Twin Coil Relays TCR and TCR-F

Download as pdf or txt
Download as pdf or txt
You are on page 1of 5

Twin relays

Twin coil relays TCR and TCR-F

Powertrain Chassis Safety Security Body Driver Convenience


Systems Systems Information
Features
- Special relay for motor
polarity reversal
- Optimized assembly
- High switching capacity

Typical applications
- Seat adjustment motors
- Window motors
- Sunroof motors
- Central locking mechanisms
- Mirror adjustment
- Steering column adjustment Car Industry
- Retractable headlamps
- Power antenna

Truck
Industry

Other
Industry
78A_3d01 / 78F_3d01

Design Conditions
Sealed; All parametric, environmental and
sealing in accordance endurance tests are performed
with IEC 68; according to EIA Standard RS-407-A
immersion cleanable: at standard test conditions unless
protection class IP 67 otherwise noted:
to IEC 529 (EN 60 529) 23 °C ambient temperature,
20-50% RH, 29.5 ± 1.0" Hg
Weight (998.9 ±33.9 hPa).
Approx. 0.67 oz. (19 g) PCB version
Approx. 0.88 oz. (25 g) version with
quick connect terminals

Nominal voltage
12 V

Terminals
PCB terminals, for assembling in
printed circuit boards
Quick connect terminals

484
All specifications subject to change. Consult Tyco Electronics AMP GmbH for latest specifications.
Twin relays

Twin coil relays TCR and TCR-F

Dimensional drawing Mounting holes


Version with PCB terminals View of the terminals (Bottom view)

.049
(1.25) 8 x Ø .053 ±.002
(1.35 ±0.05)

The nip-off-pin may be .075 ±.008


removed after soldering (1.9 ±0.2)
and washing .011 ±.008 .492
(for ventilation) (2.8 ±0.2) .354 ±.008 (12.5)
(9 ±0.2) .071 ±.012
(1.8 ±0.3)
Assembly and Nipp-off-pin .935
.689 ±.008 positioning aid 1.063 ±.008 ECR0592-A
(23.75)
(17.5 ±0.2) (27.0 ±0.2) .065 ±.012
(1.65 ±0.3)
.567 ±.012 .488 ±.008
(14.4 ±0.3) (12.4 ±0.2)

Terminals tinned
.024 ±.004
(0.6 ±0.1) .130 ±.008 .118 ±.008*)
ECR0591-2
(3.3 ±0.2) (3 ±0.2)
*) additional tin tops
max .039 inch (1 mm)

Version with quick connect terminals

.768 ±.012 1.102 ±.012


(19.5 ±0.3) (28 ±0.3)

.689 1.063
(17.5) (27) Nipp-off pin

Assembly and
positioning aid
.768 ±.012
(19.5 ±0.3)
.236
(6)

.433 ±.020 .386 ±.020


(11 ±0.5) (9.8 ±0.5)
.331
(8.4) .248 ±.004 .110 ±.004
.031 ±.002 (6.3 ±0.1) (2.8 ±0.1)
(0.8 ±0.05)
.329
.661 ±.006 (8.35) .142
(16.8 ±0.15) (3.6)
.705 ±.006 ECR1661-R
(17.9 ±0.15)

Quick connect terminal similar to ISO 8092-1

View of the terminals (Bottom view)


.661 ±.006
.331 ±.006 (16.8 ±0.15)
(8.4 ±0.15)

.142 ±.006
.329 ±.006 (3.6 ±0.15)
(8.35 ±0.15)

.705 ±.006 ECR1662-Z

(17.9 ±0.15)

485
All specifications subject to change. Consult Tyco Electronics AMP GmbH for latest specifications.
Twin relays

Twin coil relays TCR and TCR-F

Contact data
Contact configuration 2 Changeover contacts/
2 Form C
Contact material AgNi0.15
Circuit symbol
(see also Pin assignment)

Max. switching voltage 15 VDC


Max. switching current NC/NO
On1) 30 A/45 A
Off 30 A/40 A
Limiting continuous current2)
at 23 °C 30 A
at 85 °C 30 A
Voltage drop (initial) at 10 A Typ. 30 mV
Increase in coil temperature at 10 A load Typ. 6 °C
Mechanical endurance (without load) > 106 operations
Electrical endurance1) > 2 x 105 operations at 20 A, 12 V
1) The values apply to a resistive load or inductive load with suitable spark suppression.
2) At 50% ON period, max. make time 15 sec
Note: A Zener diode or a resistor is recommended for coil suppression.

Load limit curve

Load limit curve ^


= no stationary arc

Pin assignment
2 changeover contacts/
2 form C (H bridge)

PCB Version Quick connect version

Important: Check polarity

The two make contacts


cannot be closed
simultaneously.

88.1 86 31 85 88.2 15
ECR2213-M

486
All specifications subject to change. Consult Tyco Electronics AMP GmbH for latest specifications.
Twin relays

Twin coil relays TCR and TCR-F

Coil data
Available for nominal voltages 12 VDC
Nominal power consumption of the unsuppressed coil at nominal voltage 1.3 W
Test voltage winding/contact 500 VACrms
Upper limit temperature for the coil 155 °C
Maximum ambient temperature range1) – 40 to + 85 °C
Max. switching rate without contact loading 20 Hz
Operate time2) Typ. 4 msec
Release time3) Typ. 3 msec
1) See also operating voltage diagram
2) Measured at nominal voltage without coil suppression unit
3) Measured with zero volts applied (for unsuppressed relays after having been energized at nominal coil voltage)

N.B.
A low resistive device in parallel to the relay coil slows down the armature movement
and reduces the lifetime caused by increased erosion and/or higher risk of contact tack welding.

Tolerance range of the release voltage as a function of the load current


ECR2214-V
5

4,5
Release voltage [V]

4
MIN
3,5

2,5

1,5
MAX
1

0,5

0
0 10 20 30 40
Load current [A]

Operating voltage range

Does not take into account


the temperature rise due to
the contact current
E = pre-energization

487
All specifications subject to change. Consult Tyco Electronics AMP GmbH for latest specifications.
Twin relays

Twin coil relays TCR and TCR-F

Mechanical data
Cover retention1)
pull 200 N (45 lbs)
push 200 N (45 lbs)
Terminals1)
Pull force 100 N (22.5 lbs)
Push force 100 N (22.5 lbs)
Resistance to bending, force applied to front 10 N (2.25 lbs)2)
Resistance to bending, force applied to side 10 N (2.25 lbs)2)
Torsion 0.3 Nm
Enclosure
Sealed Sealed relay is suitable for immersion cleaning of PCB assembly or conformal coating.

1) Only version with quick connect terminals


2) Values applied 2 mm from the end of the terminal. When the force is removed, the terminal must not have moved more than 3 mm

Operating conditions
Temperature range, storage -40 °C to 155 °C
Test Relevant standard Testing as per Dimension Comments
Climatic cycling with condensation EN ISO 6988 20 cycles Storage 8/16 h
Temperature cycling IEC 68-2-14 Na 20 cycles – 40/+ 85 °C (dwell time 1 h)
Damp heat
cyclic IEC 68-2-30 Db, Variant 1 9 cycles Upper air temperature 55 °C
constant IEC 68-2-3 Ca 56 days
Corrosive gas IEC 68-2-42 – 10 days
IEC 68-2-43 10 days
Vibration resistance IEC 68-2-6 (sine pulse form) up to 200 Hz No change in the
acceleration > 18 g switching state > 10 µsec
Shock resistance IEC 68-2-27 (half-sine pulse form) 6 msec No change in the
acceleration, depending on position 30 … 280 g switching state > 10 µsec
Solderability1) IEC 68-2-20 Ta, Method 1 Aging 3 (4 h/155 °C)
Dewetting
Resistance to soldering heat1) IEC 68-2-20 Tb, Method 1A 10 sec ± 1 sec
with thermal screen
Sealing IEC 68-2-17 Qc, Method 2 1 min / 70 °C
1) Only PCB version

Ordering information
Part number (Replace *
with “Coil designator”) Contact Contact
TCR arrangement material Enclosure Terminals
V23078-C1*-A303 2 Form C AgNi0.15 Sealed Printed circuit
V23078-F1*-A303 2 Form C AgNi0.15 Sealed Quick connect
V23078-L1*-A303 2 Form C AgNi0.15 Sealed Printed circuit

Coil versions
Coil Rated coil Coil resistance Must Must Allowable overdrive
designator voltage +/- 10% operate voltage release voltage (VDC)
TCR (V) (Ω) (VDC) (VDC)1) at 23 °C2) at 85 °C2)
002 12 107 6.9 2.6 21.6 15.6
1) See also tolerance range of the release voltage as a function of the load current, page 487
2) Allowable overdrive is stated with no load current flowing through the relay contacts and minimum coil resistance.

Standard delivery pack (orders in multiples of delivery pack)


PCB version: 500 pieces
Quick connect version: 665 pieces
Silent version: 500 pieces

488
All specifications subject to change. Consult Tyco Electronics AMP GmbH for latest specifications.

You might also like