Aleyna Ceyhan, İpek Erdinç, Nijat Tarverdiyev, Elif Toprak, İlayda Nur Güzel
Aleyna Ceyhan, İpek Erdinç, Nijat Tarverdiyev, Elif Toprak, İlayda Nur Güzel
Aleyna Ceyhan, İpek Erdinç, Nijat Tarverdiyev, Elif Toprak, İlayda Nur Güzel
Compressor
Work_reversible (kJ/kmol) 1068.336 kj/kmol
Work_actual (kJ/kmol) 1483.8 kj/kmol
Tout_reversible, oC 62.264 oC
Tout_actual, oC 76.75 oC
Heater
Q (kW) 7.556 kW
Utility type (Tin, Tout) °C Hot Oil (Tin: 270 °C Tout: 250 °C)
Utility amount (kg/s) 0.0134 kg/s
Vaporizer
Q (kW) 1136.675 kW
Utility type (Tin, Tout) °C Saturated Steam (Tin: 270 °C Tout: 250 °C)
Utility amount (kg/s) 24.927 kg/s
Adiabatic Mixer
T6 °C 103.67 °C
Furnace
Q (kW) 2434 kW
Relative humidity of air,% -
Excess air,% -
Utility amount (kg/s) CH4 (90%)
Reactor
Adiabatic Isothermal NonAdi&NonIso
Q (kW) -11505 kW
Utility type (Tin, Tout) °C Cooling Water
Utility amount (kg/s) 551.12 kg/s
Cooler
Q (kW) 1712.871 kW
Utility type (Tin, Tout) °C Cooling Water (Tin: 10 °C Tout: 80 °C)
Utility amount (kg/s) 5.844 kg/s
Partial Condenser
Q (kW) -8167538.478 kW
Operating Temperature, °C 26.08°C
V/F 0.727
Utility type (Tin, Tout) °C Cooling Water (5 °C,20 °C)
Utility amount (kg/s) 4.195
Distillation Column I
Reflux ratio 1.21
T13 (Tdew) °C 12.8°C
T14 (Tbubble) °C 210.63 °C
Total Condenser Reboiler
Q (kW) 7848.47 7790.62
Utility type (Tin, Tout) °C Cooling Water (5°C-
Hot Oil (270°C-250°C)
10°C)
Utility amount (kg/s) 373.74 141.31
Distillation Column II
Reflux ratio
T15 (Tdew) °C
T16 (Tbubble) °C
Total Condenser Reboiler
Q (kW)
Utility type (Tin, Tout) °C
Utility amount (kg/s)