16 Product Specifications
16 Product Specifications
16 Product Specifications
500M
CS44Z3 Category 6A F/FTP Cable, low smoke zero halogen, white jacket,
4 pair count, 1640 ft (500 m) length, reel
Product Classification
Regional Availability Asia | Australia/New Zealand | EMEA | Latin America
Portfolio NETCONNECT®
General Specifications
Product Number CS44Z3
ANSI/TIA Category 6A
Conductors, quantity 8
Pairs, quantity 4
Dimensions
Cable Length 500 m | 1,640.42 ft
©2021 CommScope, Inc. All rights reserved. All trademarks identified by ® or ™ are registered trademarks,
respectively, of CommScope. All specifications are subject to change without notice. See www.commscope.com for the
most current information. Revised: November 29, 2021
884041954/16 | CS44Z3 WHT C6A 4/23 F/FTP RL
500M
Electrical Specifications
Coupling Attenuation Type II
Remote Powering Fully complies with the recommendations set forth by IEEE 802.3bt (Type
4) for the safe delivery of power over LAN cable when installed according
to ISO/IEC 14763-2, CENELEC EN 50174-1, CENELEC EN 50174-2 or TIA
TSB-184-A
Segregation Class d
Page 2 of 4
©2021 CommScope, Inc. All rights reserved. All trademarks identified by ® or ™ are registered trademarks,
respectively, of CommScope. All specifications are subject to change without notice. See www.commscope.com for the
most current information. Revised: November 29, 2021
884041954/16 | CS44Z3 WHT C6A 4/23 F/FTP RL
500M
Electrical Cable Performance
CS CommScope
STD Refers to the standard value listed under Transmission Standards in the Electrical Specifications above
TYP Typical Electrical Performance
IL Insertion Loss (dB/100m) NEXT Near End Crosstalk (dB/100m)
ACR Attenuation to Crosstalk Ratio (dB/100m) PSNEXT Power Sum Near End Crosstalk (db/100m)
PSACR Power Sum Attenuation to Crosstalk Ratio (dB/100m) ACRF Attenuation to Crosstalk Ratio - Far End (dB/100m)
PSACRF Power Sum Attenuation to Crosstalk Ratio - Far End (dB/100m) RL Return Loss (dB)
TCL Transverse Conversion Loss (dB/100m) ELTCTL Equal Level Transverse Conversion Transfer Loss (dB/100m)
31.25 10.5 52.9 42.4 49.9 39.4 38.1 35.1 23.6 25.1
155 24.1 42.4 18.4 39.4 15.4 24.2 21.2 18.8 18.1
Material Specifications
Conductor Material Bare copper
Mechanical Specifications
Pulling Tension, maximum 11.34 kg | 25 lb
Environmental Specifications
Installation temperature 0 °C to +50 °C (+32 °F to +122 °F)
©2021 CommScope, Inc. All rights reserved. All trademarks identified by ® or ™ are registered trademarks,
respectively, of CommScope. All specifications are subject to change without notice. See www.commscope.com for the
most current information. Revised: November 29, 2021
884041954/16 | CS44Z3 WHT C6A 4/23 F/FTP RL
500M
Operating Temperature -20 °C to +60 °C (-4 °F to +140 °F)
Regulatory Compliance/Certifications
Agency Classification
CENELEC EN 50575 compliant, Declaration of Performance (DoP) available
CHINA-ROHS Below maximum concentration value
ISO 9001:2015 Designed, manufactured and/or distributed under this quality management system
REACH-SVHC Compliant as per SVHC revision on www.commscope.com/ProductCompliance
ROHS Compliant
Page 4 of 4
©2021 CommScope, Inc. All rights reserved. All trademarks identified by ® or ™ are registered trademarks,
respectively, of CommScope. All specifications are subject to change without notice. See www.commscope.com for the
most current information. Revised: November 29, 2021