Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

16 Product Specifications

Download as pdf or txt
Download as pdf or txt
You are on page 1of 4

884041954/16 | CS44Z3 WHT C6A 4/23 F/FTP RL

500M

CS44Z3 Category 6A F/FTP Cable, low smoke zero halogen, white jacket,
4 pair count, 1640 ft (500 m) length, reel

Product Classification
Regional Availability Asia    |   Australia/New Zealand    |   EMEA    |   Latin America

Portfolio NETCONNECT®

Product Type Twisted pair cable

General Specifications
Product Number CS44Z3

ANSI/TIA Category 6A

Cable Component Type Horizontal

Cable Type F/FTP (shielded)

Conductor Type, singles Solid

Conductors, quantity 8

Jacket Color White

Pairs, quantity 4

Transmission Standards ANSI/TIA-568.2-D    |   ISO/IEC 11801 Class EA

Dimensions
Cable Length 500 m   |   1,640.42 ft

Cable Length Tolerance ±5%

Diameter Over Conductor 1.168 mm   |   0.046 in

Diameter Over Jacket, nominal 7.01 mm   |   0.276 in

Jacket Thickness 0.61 mm   |   0.024 in

Conductor Gauge, singles 23 AWG

Cross Section Drawing


Page 1 of 4

©2021 CommScope, Inc. All rights reserved. All trademarks identified by ® or ™ are registered trademarks,
respectively, of CommScope. All specifications are subject to change without notice. See www.commscope.com for the
most current information. Revised: November 29, 2021
884041954/16 | CS44Z3 WHT C6A 4/23 F/FTP RL
500M

Electrical Specifications
Coupling Attenuation Type II

dc Resistance Unbalance, maximum 2%

dc Resistance, maximum 7.61 ohms/100 m   |   2.32 ohms/100 ft

Mutual Capacitance at Frequency 4.2 nF/100 m @ 1 kHz

Nominal Velocity of Propagation (NVP) 80 %

Operating Frequency, maximum 500 MHz

Operating Voltage, maximum 80 V

Remote Powering Fully complies with the recommendations set forth by IEEE 802.3bt (Type
4) for the safe delivery of power over LAN cable when installed according
to ISO/IEC 14763-2, CENELEC EN 50174-1, CENELEC EN 50174-2 or TIA
TSB-184-A

Segregation Class d

Transfer Impedance Grade 2

Page 2 of 4

©2021 CommScope, Inc. All rights reserved. All trademarks identified by ® or ™ are registered trademarks,
respectively, of CommScope. All specifications are subject to change without notice. See www.commscope.com for the
most current information. Revised: November 29, 2021
884041954/16 | CS44Z3 WHT C6A 4/23 F/FTP RL
500M
Electrical Cable Performance
CS CommScope
STD Refers to the standard value listed under Transmission Standards in the Electrical Specifications above
TYP Typical Electrical Performance
IL Insertion Loss (dB/100m) NEXT Near End Crosstalk (dB/100m)
ACR Attenuation to Crosstalk Ratio (dB/100m) PSNEXT Power Sum Near End Crosstalk (db/100m)
PSACR Power Sum Attenuation to Crosstalk Ratio (dB/100m) ACRF Attenuation to Crosstalk Ratio - Far End (dB/100m)
PSACRF Power Sum Attenuation to Crosstalk Ratio - Far End (dB/100m) RL Return Loss (dB)
TCL Transverse Conversion Loss (dB/100m) ELTCTL Equal Level Transverse Conversion Transfer Loss (dB/100m)

Freq. IL NEXT ACR PSNEXT PSACR ACRF PSACRF RL TCL ELTCTL


MHz
STD STD STD STD STD STD STD STD STD STD

1 2.1 75.3 73.2 72.3 70.2 68 65 20 40 35

4 3.8 66.3 62.5 63.3 59.5 56 53 23 34 23

8 5.3 61.8 56.4 58.8 53.4 49.9 46.9 24.5 31 16.9

10 5.9 60.3 54.4 57.3 51.4 48 45 25 30 15

16 7.5 57.2 49.8 54.2 46.8 43.9 40.9 25 28 10.9

20 8.4 55.8 47.4 52.8 44.4 42 39 25 27 9

25 9.4 54.3 45 51.3 42 40 37 24.3 26 7

31.25 10.5 52.9 42.4 49.9 39.4 38.1 35.1 23.6 25.1

62.5 15 48.4 33.4 45.4 30.4 32.1 29.1 21.5 22

100 19.1 45.3 26.2 42.3 23.2 28 25 20.1 20

155 24.1 42.4 18.4 39.4 15.4 24.2 21.2 18.8 18.1

200 27.6 40.8 13.2 37.8 10.2 22 19 18 17

250 31.1 39.3 8.3 36.3 5.3 20 17 17.3 16

300 34.3 38.1 3.9 35.1 0.9 18.5 15.5 16.8

350 37.2 37.1 -0.1 34.1 -3.1 17.1 14.1 16.3

400 40.1 36.3 -3.8 33.3 -6.8 16 13 15.9

500 45.3 34.8 -10.4 31.8 -13.4 14 11 15.2

Material Specifications
Conductor Material Bare copper

Insulation Material Polyolefin

Jacket Material Low Smoke Zero Halogen (LSZH)

Shield (Tape) Material Polyester/Aluminum shield

Mechanical Specifications
Pulling Tension, maximum 11.34 kg   |   25 lb

Environmental Specifications
Installation temperature 0 °C to +50 °C (+32 °F to +122 °F)

-20 °C to +60 °C (-4 °F to +140 °F) Page 3 of 4

©2021 CommScope, Inc. All rights reserved. All trademarks identified by ® or ™ are registered trademarks,
respectively, of CommScope. All specifications are subject to change without notice. See www.commscope.com for the
most current information. Revised: November 29, 2021
884041954/16 | CS44Z3 WHT C6A 4/23 F/FTP RL
500M
Operating Temperature -20 °C to +60 °C (-4 °F to +140 °F)

Acid Gas Test Method IEC 60754-2

EN50575 CPR Cable EuroClass Fire Performance Dca

EN50575 CPR Cable EuroClass Smoke Rating s2

EN50575 CPR Cable EuroClass Droplets Rating d2

EN50575 CPR Cable EuroClass Acidity Rating a1

Environmental Space Low Smoke Zero Halogen (LSZH)

Flame Test Method IEC 60332-3-24

Smoke Test Method IEC 61034-2

Packaging and Weights


Cable weight 48.499 kg/km   |   32.59 lb/kft

Packaging Type Reel

Regulatory Compliance/Certifications
Agency Classification
CENELEC EN 50575 compliant, Declaration of Performance (DoP) available
CHINA-ROHS Below maximum concentration value
ISO 9001:2015 Designed, manufactured and/or distributed under this quality management system
REACH-SVHC Compliant as per SVHC revision on www.commscope.com/ProductCompliance
ROHS Compliant

Page 4 of 4

©2021 CommScope, Inc. All rights reserved. All trademarks identified by ® or ™ are registered trademarks,
respectively, of CommScope. All specifications are subject to change without notice. See www.commscope.com for the
most current information. Revised: November 29, 2021