FTU-200 Series Catalog - M
FTU-200 Series Catalog - M
FTU-200 Series Catalog - M
www.pnctech.co.kr
FTU
FTU-P200
Pole-mounted Load Break Switch Control
FTU-R200
Automatic Circuit Recloser Control
Our high technology doesn’
t allow even 1% tolerance of error.
PNC Technologies is a company that creates an increasingly convenient world as it is a group of technology
specialists who pursue innovations for human comfort and who are geared towards service maintenance,
upholding clients and proven safety through impeccable verification and testing, and creating reliable state
-of-the-art digital technological powers.
FTU-R200 FTU-P200
Automatic Circuit Recloser Controller Pole-mounted Load Break Switch Controller
Key Features
• Integrated multi-functions on new microprocessor based platform - Fault detection & Protection, Metering, Control,
Status monitoring, Power quality monitoring.
• Directional protection, Negative sequence protection, SEF and lots of built-in over-current protection curves including IEC,
ANSI/IEEE, Recloser curves and customized curves.
• Multi-port, multi-protocol communication support (DNP3.0, DNP3.0 over TCP/IP, IEC60870-5-101/104), modem control &
dial-up function for SCADA.
• DNP3.0 subset level 3 with information index mapping & class assignment.
• Large size memory for load profiling, event and fault recording. Available Disturbance waveforms with COMTRADE format.
• Intelligent power supply & battery charger with built-in self-diagnosis & test function.
- Easy maintenance through separated module design with simple CAN interface.
• Customized supports for special user-required functions and firmware upgradable at site.
Hardware
RTU
• Dual Processor : CPU(ARM9) + DSP
• 16-bit A/D converter
• Non-volatile memory : FRAM(1 Mbytes), Flash ROM (2 Mbytes)
• HMI : LCD 20 characters * 4 lines with LED backlight, Buttons, LEDs
• 10 Contact inputs, 4/6 Digital Outputs (Electrical isolation) : Configurable
• 2 channel 4~20mA TD inputs
• RS232C, ETHERNET, RS232C/RS485
Controller
• Battery charger with test circuit
• Power supply for FTU and modem
• LBS Motor driving
• CAN interface
Control box
• Step down transformer (AC220V/30V)
• Lead acid battery (12V*2, 18Ah-Standard)
• Modem space
• IP54
Main functions
Metering
• 128 Samples per cycle
• Galvanic isolation through Aux. CT & Aux. PT
• Secondary of 1000:1 CT ~ 12.5A, Up to 200% of rated voltage
• Currents(A,B,C,N), Voltages(A,B,C/R,S,T) : RMS, Phasors, Sequence components, Harmonics
• Power : Apparent(kVA), Active(kW), Reactive(kVar), Power factor
• Energy : 4-quadrant metering, import / export active energy, inductive / capacitive reactive energy.
• Frequency
• Demand Profile
• Report value by deadband
Status monitoring
• 10 Contacts input : Open, Closed, Lock, Gas low, Door open, etc.
- Opto-isolation
- Delay timers for de-bouncing of each contact input
- Configurable : Name, Interlock condition, Inverted status
• Controller status (battery & battery charger test result)
- External AC power loss
- Battery low, Battery Fail, Battery overvoltage, Battery Charger Fail, Grounded battery
- Battery voltage
• Control Status
- Operator place : Local/Remote
- Control Lock
- Recloser On/Off, Protection On/Off, Ground Protection On/Off Function Status
- Fault indicators, PQM status, Live Line(source, load side), Phase sync., Reclosing status
- Under voltage status, Under frequency status, Self-diagnostics status, etc.
- Analog Hi/Low alarm
Control
• 4 contacts output, 2 high-speed outputs
- Open(Trip), Close, Spares
- Configurable : Name, Pulse width
A
Protection
• Fault passage indicator
• 3-stage over current protection (directional or non-directional) Current[A]
- Fast and delayed TC trip elements for phase and earth fault Parameters of TC curve
- 67 types of built-in TC Curves (IEC, ANSI, Recloser curves) and 4 Customized TC
Curves - Definite time over-current element
- Definite time HCT (High Current Trip)
• Negative sequence over-current protection Max Torque Angle
• Sequence coordination
• Open line detection Angle (+30°)
Event/Fault Recording
• SOEs are stored on non-volatile memory with 1ms time-stamp
• Event history buffers are categorized by group
- I/O Events, Function Events, System Events
- Fault current Events, Fault Location
- PQM Events
- Demand I,P,Q
- Daily Max. I,P,Q
- Counter : Switch open, Fault, Restart
• Fault waveform recording
- 8 faults, 6 PQM waveforms can be stored on non-volatile memory
- 1 Manual triggered waveform
- 128 samples/cycle, 40 cycles
- Waveforms are stored as COMTRADE file format
Auxiliary functions
• Self-diagnosis
• CAN interface with controller
• PC software for setting & maintenance
• Waveform evaluation software
• Firmware upgradable at site Example of waveform evaluation
Typical Application
Technical Data
For FTU-R200 only: -Setting Group Change on VT Automation Open • Detection Time 0.1~60.0 sec (step : 0.1sec)
-Setting Group Restoration Time from Live-Live
Current Unbalance
System Configuration • Detection Level 0~100 % (step : 1 %)
I/O • Detection Time 0.1~60.0 sec (step : 0.1sec)
• DI Debounce Time 10~500 msec (step : 5 msec)
• DO Pulse Width 10~30000 msec (step : 10 msec) Sag
• Detection Level 0.50~0.99 pu (step : 0.01)
AC Rating • Detection Time 0.5~10.0 cycle (step : 0.5cycle)
• Line Configuration Y-G/DELTA
• System Frequency 50 or 60 Hz Swell
• Rated Voltage (L-L) 1.00~40.00 kV (step : 0.01 kV) • Detection Level 1.01~1.50 pu (step : 0.01)
• Reference Voltage (L-N) 1.00~30.00 kV (step : 0.01 kV) • Detection Time 0.5~10.0 cycle (step : 0.5 cycle)
• Reference Phase A/B/C
• CT Ratio (1A nominal) 1~5000 (step : 1) Interruption
• Detection Level 0.10~0.49 pu (step : 0.01)
• CT Direction FWD/REV
• Detection Time 0.5~10.0 cycle (step : 0.5cycle)
• NCT Ratio (1A nominal) 1.0~5000.0 (step : 0.1)
• NCT Direction FWD/REV
Voltage THD Alarm
• Phase Rotation A-B-C/A-C-B
• Alarm Level 0.5~100.0 % (step : 0.1%)
• Detection Time 0.2~60.0 sec (step : 0.2sec)
Waveform Trigger
• Sample Record Frequency 16/32/64/128 Samples per cycle
Current THD Alarm
• Pre-1st Cycle 1~10 cycle
• Alarm Level 0.5~100.0 % (step : 0.1%)
• Post 2nd Cycle 1~10 cycle
• Detection Time 0.2~60.0 sec (step : 0.2sec)
• Pre-2nd Trigger cycle 1~20 cycle
Reset Annunciator
Frequency
• Measuring range 45~65 Hz
Battery Test
• Accuracy ±0.02 Hz
Protection Function Blocking
• Reclosing / Protection (All) / Earth Protection (Earth & SEF) Energy
• A-phase, B-phase, C-phase and 3-phase
• Rollover 16-bit counter : kWh, kVARh(Import & Export)
HMI • Accuracy ±4%
Harmonics
LCD 20characters * 4 lines, LED backlight
• Ia, Ib, Ic, In and I3ph THD (%)
• Source-side Va, Vb, Vc and V3ph THD (%)
LED
• 2nd ~31st Harmonics (A, kV) Ia, Ib, Ic, In, Va, Vb, Vc
• Switch status Open. Closed, Gas low
Remote, Recloser Enable, Protection Enable,
• Control status VOC (Value Of Change)
Ground Enable, Control Lock, Select
Live line (Source/Load), FPI A/B/C/N/SEF, UV A/B/C,
• Function status
Sync. Fail, Reclosing Ready/Progress/Lockout
• Comm. status
Tx,Rx,RTS (SCADA Port), Ethernet Link, Recording
Active Tx, Rx (protection data)
• System status CPU Run, Error
Events
• Power supply status • Time tag 1ms time resolution
Ext. Power, Batt. Low, Batt. Fail, Charger Fail
• I/O events (1023) / Functional events (20000) / System events (255)
Button MENU/UP/DOWN/ENTER, REMOTE,
CONTROL LOCK, SELECT, OPEN, CLOSED, Communication Events (255) / Fault events (1023) / PQM events (255)
RESET, RECLOSER ENABLED, PROTECTION Demand I,V,P,Q Events (6143) / Daily Peak I,V,P,Q events (1023)
ENABLED, GROUND ENABLED, BATTERY / Energy & Peak Demand Profile (63)
TEST, LAMP TEST (Configurable)
Counter
Measurements • FTU Restart Count, Switch Trip (Open) Count
• Fault Count (A / B / C / N), Total Fault Count
Current
• RMS (A) & Phase Angle (Deg) a, Ib, Ic, In, I1, I2 Fault/PQM Waveform
• True RMS (A) Ia, Ib, Ic • Up to 15 waveforms are stored.(128 samples/cycle, 40 cycles)
• Data can be stored as COMTRADE file format.
• Accuracy ±1% or 1A (2~600A), ± 3% (600~12,000A)
• Reading Range 2~12,000A (External CT Ratio 1,000:1)
Protocols
LBS or Recloser Interface • DNP 3.0 (Level 3) or IEC60870-5-101
• Basically, FTU-P200 and FTU-R200 have 2 receptacles for MS
Connectors on the enclosure bottom. (3-pin cable for external AC
power input & 37-pin control cable for switch interface) Control cable Baud Rate
pins include 3 CT s analog inputs for currents, 6 PT s analog inputs for • 1200 ~ 19200 bps
source-side (A/B/C) and load-side (R/S/T) voltages, digital inputs for
status monitoring, and digital outputs for control.
This original interface configuration can be customized for external Connector Type
CT/PT connections.
• DB9 Male
Heater 25W
(optional) Power Consumption
Bottom View
DOOR
20 250 450
PACKING
BODY
"A" "A"
SECTION "A"-"A"
INTERNAL PANEL
0°
12
750
690
430
650
DOOR
22
90
50
MODEM CABLE
VENTILATOR
POWER RECEPTACLE
CONTROL RECEPTACLE
RØ SØ TØ
CT Protection Board
IA Ia A A
MODEM (out of supply)
1000:1 B B RS232 CABLE(out of supply)
CT1 C C
IB Ib 1 : F.G
1000:1
D D FRAME GROUND 2 : F.G CN1 3 1
CN1
CT2 3 : DC+ (POWER) 4 2
IC Ic 4 : DC-
1000:1
CT3 1 : DI2(C)
IN In 2 : DI4
3 : DI6
4 : DI7 7 1
S4 VR Vr H H
5 : DI9 8 2
S5 VS Vs J J
6 : COM2 CN2 9 3
CN2
7 : DI1(O) (STATES) 10 4
8 : DI3 11 5
S6 VT Vt K K 9 : DI5
Voltage Calibration Board
12 6
10 : COM1
11 : DI8
POWER Board 12 : DI10
1 : DO1+
S1 VA Va E E JP4
(CAN)
OPEN- 6
2 : DO1-
1 OPEN 3 : DO2+
2 CLOSE 3 1 CLOSE+ 5
S2 VB Vb F F 3 6 4 : DO2-
3 DI_COM 4 2 BATT- 4 9 1
JP6 2 5 5 : DO4+
4 DI_COM OPEN+ 3
6 : DO4- 10 2
S3 VC Vc G G (DI) 1 4 CLOSE- 2
7 : PO2+ 11 3
BATT+ 1
8 : PO2- CN3 12 4
(F.GND)
9 : DO1+ (CONTROL) 13 5
CN3
FG Vcom P P FRAME GROUND
JP5 4 BAT."-" 4 10 : DO1- 14 6
AC.GND 11 : DO2+
R R 1 DC.GND 1 3 BAT."+" 3 15 7
F.GND F.GND 2 CL/OP 2 J4 BATTERY 2 12 : DO2- 16 8
2
AØ BØ CØ 3 DC.GND 3 1 START 1
13 : DO3+
4 CL/OP 4 14 : DO3-
15 : PO1+
Close/Open Control(+24V) S S
(DO) 2 D.GND 2
16 : PO1-
J3 +24V 1
T T 1 1
1 : VA
(FTU PWR) 2 : VB 2
MO 3 : VC 3
r r 1 AC 30V 1 2 D.GND 2
J2 J1 4 : Vabc COM CN4 4
DC.GND s s 2 AC 30V 2 1 +12V 1
5 : VR (VOLTAGE) 5
CN4
(MODEM PWR) 6 : VS 6
Handle Lock U U 7 : VT 7
MLS Handle Lock_COM F.GND 8 : Vrst COM 8
GAS V V
1
1 : IA
PS GAS_COM X X 2 : IB 2
3 : IC CN5 3
CN5
Close a a 4 : ICOM (CURRENT) 4
Close/open_COM b b
5 : 3IO+ 5
M1 6 : 3IO- 6
Open c c
Close d d
1 2 DOOR S/W
M2
Close/open_COM e e NC COM
3 4
Open f f
POWER
BATTERY START
SWITCH
J4
+24V m m
DC.GND n n 1 4
FUSE 30A
+ 1
BATTERY
24V/26Ah J5
P.T(200VA) -
V I
+ COM +
POWER_IN(AC230V) 230V
FUSE(3A)
A : AC1 30V
B : AC2 0V
FTU-R200
MECHANISM 37P RECEPTACLE CONTROL BOX FTU-R200
RS232C
/485 RS232C TCP/IP CAN TD
AØ BØ CØ
CT Protection Board
IA Ia A A
1000:1 B B
CT_AØ C C MODEM (out of supply)
IB Ib RS232 CABLE(out of supply)
D D
1000:1 1 : F.G
CT_BØ 2 : F.G CN1 3 1
CN1
IC Ic
3 : DC+ (POWER) 4 2
1000:1 4 : DC-
CT_CØ
IN In
1 : DI2(C)
VA Va E E 2 : DI4
POWER BOARD 3 : DI6
4 : DI7 7 1
VB Vb F F 8 2
5 : DI9
6 : COM2 CN2 9 3
CN2
VC Vc G G
(CAN) 7 : DI1(O) (STATES) 10 4
Voltage Calibration Board
8 : DI3 11 5
9 : DI5 12 6
10 : COM1
11 : DI8
4 12 : DI10
BAT."-" 4
3 BAT."+" 3
VR Vr H H J4 1 : DO1+
2 BATTERY 2
2 : DO1-
VS Vs J J 1 START 1
3 : DO2+
4 : DO2-
9 1
VT Vt K K 2 D.GND 2 5 : DO4+
J3 6 : DO4- 10 2
1 +24V 1
11 3
7 : PO2+
(FTU PWR) 8 : PO2- CN3 12 4
CN3
Vcom L L 1 AC 30V 1 2 D.GND 2 9 : DO1+ (CONTROL) 13 5
J2 J1 10 : DO1- 14 6
AC_GND
2 AC 30V 2 1 +12V 1
11 : DO2+ 15 7
N N (MODEM PWR)
F.GND F.GND F.GND 12 : DO2- 16 8
13 : DO3+
14 : DO3-
15 : PO1+
Close Control(+24V) P P 16 : PO1-
Open Control(+24V) R R
1
1 : VA
2 : VB 2
GAS LOW U U
CL OP PS GAS LOW_COM V V
3 : VC 3
4 : Vabc COM CN4 4
CN4
5 : VR (VOLTAGE) 5
Handle Lock W W 6 : VS 6
MLS Handle Lock_COM X X 7 : VT 7
8 : Vrst COM 8
Close a a
1 : IA 1
Close/open_COM b b 2
M1 2 : IB
Open c c 3 : IC CN5 3
CN5
4 : ICOM (CURRENT) 4
Close d d 5 : 3IO+ 5
6 : 3IO- 6
Close/open_COM e e
M2
Open f f
OP CL 1 4
POWER
SWITCH
1
FUSE 30A
+
P.T(100VA)
J5
-
POWER_IN(AC230V) 230V
FUSE(3A) BATTERY V I
A : AC1 30V 24V/26Ah + COM +
B : AC2 0V
Sales Office
Address : 6F, Kwangmyung B/D, 189, Ogeum-ro, Songpa-gu, Seoul, 05642 Korea
Tel: +82-2-2240-8106 Fax: +82-2-2240-8188
http://www.pnctech.co.kr