Machine-Room-Less Elevator: in Compliance With The Standards of EN81-20 and EN81-50
Machine-Room-Less Elevator: in Compliance With The Standards of EN81-20 and EN81-50
Machine-Room-Less Elevator: in Compliance With The Standards of EN81-20 and EN81-50
“Made in Fujitec”
By providing people with the safe and reliable elevators that
Fujitec manufactures in-house, Fujitec is building trust with
people around the world.
By manufacturing safe and reliable elevators,
we are building trust with people around the world.
Fujitec’s “Global Common Components” are used in
the REXIA brand. The quality of components, such
as traction machines, elevator controllers, and
operating fixtures, is controlled through Fujitec’s
integrated system of global quality management.
Elevators with the same high quality will be provided
by Fujitec’s global production base under the
concept of “Made in Fujitec”.
2
Product Concept
Ecology
In REXIA elevators, the gearless traction machines
with a permanent magnetic synchronous motor
assure low power consumption. Also, the electric
power regenerative unit equipped between the
elevator controller and the power supply saves the
electrical energy consumption in the building.
Fujitec contributes to global society by providing for
ecology-conscious products, reflecting on them 70
years of knowledge and technologies accumulated
through the manufacturing of elevators.
Comfort Design
Under Fujitec’s universal designs, newly adopted
buttons for elevator operating fixtures are highly
visible and tactually recognizable, and the numbers
and letters shown on aesthetically refined displays
can be easily seen and read.
Also, various styles for the decoration of elevator
interior and landing floors provide the passengers
with a superb and comfortable riding experience.
3
Contents
Ecology 9
Comfort Design 11
Car Design 13
Ceiling Design 23
Options 24
Entrance Design 25
EN81-70 Requirements 26
Hall Fixtures 29
630
Work by Others 36
800
1000
Global Operations 38
1200
1275
1350
1600
1800
2000
4
Safety & Reliability
An elevator operation system with multiple microcomputers makes maximum use of a “Distributed Control System.” Hall indicators,
car operating boards, and control panels incorporate high-performance microcomputers. These independent microcomputers
analyze elevator operating conditions utilizing self-diagnostic functions and implement immediate control of elevator operations.
Also, data transmission buses between microcomputers increase data processing capability.
15
comprehensively calculates passenger waiting time
10
based on extrapolated data of probable future passengers,
5
how many passengers will come to a certain floor when a
0
hall call is registered and/or how many passengers will 6:00 9:00 12:00 15:00 18:00 21:00
Time
come to a certain floor when no hall call is registered. Conventional Group Supervisory Control System
This comprehensive analysis reflects whole building traffic Virtual Passenger Optimization Method
conditions for efficient elevator operation control as well as * The graph shows the results of a simulation to reproduce the daily traffic in an actual high-rise condominium having
three elevator units and 33 stops.
5
- Destination Floor Guidance System -
Elevator Operating System with EZSHUTTLE Low Zone Mid Zone High Zone
Passengers are waiting in front of the Each group of passengers can ride
elevators indicated on the entry terminals. in the elevator bound for its destination.
Before Elevator’s Arrival At the Time of Passengers’ Riding
GSC System
A B C A B C
Intelligence
Computer
Neuro GSO
Multi-Beam Sensor
Multi-beam Sensor emits multiple infrared beams, creating an
invisible curtain covering the entire doorway. If any of the beams
is interrupted, the closing doors will stop and reopen.
This function results in a significantly higher detection rate of a
passenger and/or an object in the doorway.
6
Safety & Reliability
For Passengers
1 Prevention of the Occurrence of
the Ascending Elevator’s Overspeed
(ACOP: Ascending Car Overspeed Protection)
In order for the ascending elevator not to overspeed, the elevator system is
equipped with ascending car overspeed protection means.
7
For Maintenance Staff
1 Refuge Space on Car Roof
and Clearance in Headroom
The layout of elevator equipment on car roof
and overhead space complies with the
requirements of EN81-20. Due to this
compliance, refuge space is increased for the
safety of maintenance staff.
For details of the full requirements, see the official document of EN81-20 and EN81-50.
8
Ecology
In addition, REXIA’s small machines require less motor capacity and power consumption compared to
conventional elevators. The differences are shown below.
9
LED Lights on Car Ceiling
Fujitec’s adoption of energy-efficient, long-lasting LED
downlights for car ceiling light saves energy, and leads to the
preservation of environment.
Control Gearless
Power Supply
Panel Machine
10
Comfort Design
The latest human engineering technologies are reflected on the REXIA elevators.
As the function of man-machine interface, tactile characters and letters are
adopted for the buttons on the elevator operating boards and the elevator call
buttons in the hall fixtures. Also, the devices and functional systems for the
creation of comfort for the elevator passengers are equipped in the elevator.
11
Tactile Letters and Characters
for Operating Buttons
Standard
Tactile letters and characters are adopted for the elevator operating buttons. They are raised
from the surface of the buttons in order for a passenger to recognize the assigned function for
each button. Their unique design functions as a friendly interface between the passengers and
the elevators.
IONFUL
(Plasmacluster™* ION Generating Device)
Optional
VONIC
(Automatic Voice Announcement System)
Optional
12
Car Design
13
Color Variation
For Car Ceiling
5AABJ001 5AABJ002 5AABJ003
Design 1
CT-GS01
Ceiling with LED downlights
Car Ceiling
Steel Sheet with Paint Finish
Color: Light Gray (5AABJ003)
Car Panel Stainless Steel with Hairline Finish
Return Panel Stainless Steel with Hairline Finish
Car Transom Stainless Steel with Hairline Finish
Car Door Stainless Steel with Hairline Finish
PVC Tiles with 2-mm Thickness
Car Floor
Color in the image: Light Gray (L52)
Car Sill Extruded Aluminum
COB-GS02
Car Operating Board
Stainless Steel with Hairline Finish
Ventilation Fan With Two Air vents
15
Design 2
CT-GC03
Ceiling with indirect lighting LED downlights
Car Ceiling
Steel Sheet with Paint Finish
Color: Ivory (5AABJ002)
Steel Sheet with Paint Finish
Car Panel Color: Gold (5AABJ011)
Stainless Steel with Hairline Finish
Return Panel Stainless Steel with Hairline Finish
Car Transom Stainless Steel with Hairline Finish
Steel Sheet with Paint Finish
Car Door
Color: Gold (5AABJ011)
PVC Tiles with 2-mm Thickness
Car Floor
Color: Brown (L56)
Car Sill Extruded Aluminum
COB-GS01
Car Operating Board
Stainless Steel with Hairline Finish
Side: Stainless Steel with Hairline Titanium-Gold-Finished (CPH-GC04)
Handrail
Rear: Stainless Steel with Hairline Finish (CPH-GC01)
16
Car Design
Design 3
CT-GC02
Ceiling with indirect lighting LED tubes
Car Ceiling
Steel Sheet with Paint Finish
Color: Light Gray (5AABJ003)
Car Panel Stainless Steel with Mirror Finish
Return Panel Stainless Steel with Mirror Finish
Car Transom Stainless Steel with Mirror Finish
Car Door Stainless Steel with Mirror Finish
PVC Tiles with 2-mm Thickness
Car Floor
Color: Light Gray (L52)
Car Sill Extruded Aluminum
COB-GC01
Car Operating Board
Stainless Steel with Hairline Finish
17
Design 4
CT-GC02
Ceiling with indirect lighting LED tubes
Car Ceiling
Steel Sheet with Paint Finish
Color: White (5AABJ001)
Stainless Steel with Etching Finish
Car Panel
Pattern: PH-103C
Return Panel Stainless Steel with Hairline Finish
Car Transom Stainless Steel with Hairline Finish
Stainless Steel with Etching Finish
Car Door
Pattern: PH-103C
PVC Tiles with 2-mm Thickness
Car Floor
Color: Medium Gray (L53)
Car Sill Extruded Aluminum
COB-GC02
Car Operating Board
Stainless Steel with Hairline Finish
Mirror Upper-side Full-width Mirror
18
Car Design
Design 5
CT-GC01
Ceiling with indirect lighting LED lamps
Car Ceiling
Steel Sheet with Paint Finish
Color: Ivory (5AABJ002)
Steel Sheet with Paint Finish
Car Panel
Color: Ivory (5AABJ004) & Ocean Blue (5AABJ009)
Steel Sheet with Paint Finish
Return Panel
Color: Ivory (5AABJ004)
Steel Sheet with Paint Finish
Car Transom
Ocean Blue (5AABJ009)
Steel Sheet with Paint Finish
Car Door
Ocean Blue (5AABJ009)
PVC Tiles with 2-mm Thickness
Car Floor
Color: Black (L54)
Car Sill Extruded Aluminum
COB-GC01
Car Operating Board
Stainless Steel with Hairline Finish
19
Design 6
CT-GC01 with ventilation fans, Ceiling with indirect lighting LED lamps
Car Ceiling
Steel Sheet with Paint Finish, Color: White (5AABJ001)
Stainless Steel with Etching Finish
Side Panels:
Pattern: PH-313
Car Panel at the Center: Full-Height Mirrored Stainless Steel
Rear Panels: at the Sides: Stainless Steel with Etching Finish
Pattern: PH-313
Return Panel Stainless Steel with Hairline Finish
Car Transom Stainless Steel with Hairline Finish
Car Door Stainless Steel with Etching Finish, Pattern: PH-313
Car Floor PVC Tiles with 2-mm Thickness, Color: Light Brown (L55)
Car Sill Extruded Aluminum
Car Operating Board COB-GC02, Stainless Steel with Hairline Finish
Handrail Stainless Steel Plate with Hairline Finish (CPH-GC02)
Mirror Full-Height Mirror Panel flush with Car Panel
20
Color and Pattern Variations
21
For Car Panel, Return Panel, Car Door, Car Transom,
Jamb, Landing Door and Landing Transom;
Paint Finish (Semi-gloss finish)
5AABJ004 5AABJ005 5AABJ006 5AABJ007 5AABJ008 5AABJ009 5AABJ010 5AABJ011
Ivory Light Gray Beige Sakura Light Green Ocean Blue Silver Gold
Note:
(1) Actual colors may differ from the image. (2) The dimensions of an actual pattern differ from the image. (3) The scale of an actual design differs from the image.
22
Ceiling Design
Standard Optional
Air vent*4
CT-GC01 *1 CT-GC03 *2
Lighting: Indirect Lighting LED Lamps Lighting: Indirect Lighting LED Downlights
Panel: Paint Finish Panel: Paint Finish
Emergency Exit*3 Emergency Exit*3
Air vent*4
Note:
*1. Clear Ceiling Height: 2350mm, Top Ceiling Height: 2350mm
*2. Clear Ceiling Height: 2250mm, Top Ceiling Height: 2400mm
*3. Emergency exit (Required). Applicable for the above ceiling designs.
*4. Two Air vents added when Car Ventilation Fan is applied (Optional Specification)
23 *5. When the car interior width is greater than 1650mm, the acrylic ceiling will be divided into four sheets instead of two.
Options
Handrail
Stainless Steel with Hairline Finish
Pipe Handrail with curved ends Pipe Handrail with straight ends Flat-plate Handrail with curved ends
Titanium-Gold-Finished Pipe Handrail with Titanium-Gold-Finished Pipe Handrail with Titanium-Gold-Finished Flat-plate Handrail with
curved ends straight ends curved ends
Mirror
Standard Wall-Mounted Mirror Upper-side Full-width Mirror Full-height Mirror Panel flush with Car Panel
Standard
Optional
Optional
25
EN81-70 Requirements
700mm
Buttons
1100mm
2. Maximum height between the floor
level and the centerline of the
highest button is 1100mm.
1. For TYPE 1,
the required minimum width of
entrance is 800 mm.
2. For TYPE 2,
900-mm width is recommended for
the entrance.
3. For TYPE 3,
1100-mm width is recommended for
the entrance.
Min. 1400mm
Min. 1400mm
800mm
900mm 1100mm
26
Car Operating Boards
Standard Optional
With standard car With ten-key car With standard car With ten-key car
call buttons call buttons call buttons call buttons
27
Car Position Indicator Button
Tactile
Note:
1. Car Operating Boards satisfy the requirements of EN81-70.
2. Some floor names and alphabet letters are not applicable for the indication of
a destination floor.
3. The incorporation of key switch on the Car Operating board (COB) is Optional.
4. For Center-opening doors; when entering the car; Car Operating Board on the
right hand side
5. For Side-opening doors; Car Operating Board on the closing jamb side.
28
Hall Fixtures
Standard Optional
29
Hall indicator Hall Lantern
Faceplate Stainless Steel with Hairline Finish
HLL-GS01
HIN-GS01 * *
1, 3
Simplex Operation, Duplex
Elevator Operation Operation, and Group
Operation
With Inclined Rim at Bottom
Faceplate Design
Simplex Operation, Duplex Operation, and Group End
Elevator Operation
Operation
Faceplate Design With Inclined Rim at Side Ends
Note:
*1. The requirements by EN81-70 are satisfied. *4. The incorporation of key-switch is Optional
*2. The requirements by EN81-70 are not satisfied. *5. The hall fixtures at the bottom floor have a box behind its faceplate.
*3. Some floor names and alphabet letters are not applicable. 30
Specification Details
Main Specifications
Note: *For application range other than the above, please contact our local office for detail.
31 *The above specifications may change without prior notice.
1. Elevator Operation Control System
For One Elevator: Landing calls in the direction in which the elevator is traveling are served sequentially. After all the
1-Car Selective Collective Operation landing calls are served, landing calls in the opposite direction will be served. When there are no
(: Simplex Collective Operation) incoming calls, the elevator stops and stays at the last served floor.
For Two Elevators in a Bank: Two selective-collective-operation elevators work together in one group. Landing calls are served
2-Car Selective Collective Operation by either elevator that can respond first. When there are no calls, one will be on standby at the
(: Duplex Collective Operation) main floor; the other will stay at the last served floor.
For Two to Eight Elevators in a Bank: The operation of more than two elevators in a bank is controlled by a group supervisory system
Group Control Operation which calculates passenger waiting time in advance based on the accumulated traffic data, such
For 2 to 8 Elevator in a bank as passenger travel patterns and passenger volume at each floor, etc.
Functions and
Details ●: Standard / ■: Optional
Specific-Purpose Operations, etc.
In the event that an elevator floor isn't leveled with the landing
Automatic Releveling floor, the Automatic Releveling function will initiate and make the ●
elevator floor flush with the landing floor.
During the night time when the elevator doesn’t receive any car
Night-Time Self-Checking
and hall calls, the system will move the elevator and check the ●
Operation
mechanical brake conditions automatically.
Functions and
Details ●: Standard / ■: Optional
Specific-Purpose Operations, etc.
When an elevator does not receive any car- or hall- calls for a
Automatic Return to Main Floor certain period of time, the Automatic Return to Main Floor
●
(for Group Control Operation) function makes the elevator go to the lobby or a predetermined
floor and waits in standby for passengers to board.
If the car doors are held open over a given period of time, the
Door Nudging Door Nudging function will close them slowly with an audible ●
alarm.
Efficient-Operation
Functions
When a traveling car is fully loaded, it will bypass floors where hall
calls are registered. Those hall calls will be assigned to another
Load Bypass ■*
available elevator.
*For Group Control Operation, Load Bypass is originally furnished
Wrong Car-Call Register In case a passenger presses the wrong car call button,
●
Cancellation this mistake can be cancelled by pushing the same button twice.
Functions and
Details ●: Standard / ■: Optional
Specific-Purpose Operations, etc.
Battery-Powered Automatic In the event of a power failure, a compact battery power source
■
Landing Operation (LANDIC) will move the car to the nearest available floor.
Door Opening Failure Rescue When an elevator fails to open the doors at a landing floor, it will
●
Operation move to the next available floor and open them.
CCTV-Camera Cables For a CCTV camera, video-signal cables between the hoistway
(between car and elevator control ■
and control panel are available.
panel)
Elevator Operation Supervisory Through an elevator operation supervisory panel, the statuses of
Equipment for Panel (such as watching board, elevator operation can be monitored and the elevator operation ■
Building Security, console panel, etc.) controlled.
etc.
1. When a temperature reaches at 40 ºC (104 ºF), the relative humidity does not go beyond 50%.
2. In the year’s most humid month(s), relative humidity shall be kept lower than 90 % and the temperature lower than 25ºC (77 ºF).
Relative Humidity
3. Dew condensation prevention measures shall be taken, if there are the possibilities that condensation form inside and on
electrical equipment.
Allowable Error of Voltage Value The allowable error of voltage value is 7 % above and below the rated voltage.
30 meter or less 0 to 25 mm or less (Hoistway tolerance: 0 to 25mm or less on one side, 0 to 25mm or less in total)
more than 30 m up to 60 m or less 0 to 35 mm or less (Hoistway tolerance: 0 to 25mm or less on one side, 0 to 35mm or less in total)
more than 60 m 0 to 50 mm or less (Hoistway tolerance: 0 to 25mm or less on one side, 0 to 50mm or less in total)
For Hoistway
1. Construct solid-state, fire-proof elevator hoistway.
2. Cut out landing walls for Fujitec’s installation of elevator operating fixtures and elevator equipment.
3. Do wall finishing work by filling cement between jambs and landing walls.
4. Do wall finishing work by filling cement between landing fixtures and landing walls.
5. Give water-proofing and drainage treatment in elevator pit including the installation of pumping equipment.
When hoistway is constructed with bricks, put steel lintels in its walls for Fujitec’s installation of rail brackets. The steel lintels must be completely
8. fixed inside the walls. The vertical height of the lintel is required to be 300 mm or more. For details, see the relevant drawings.
When an elevator traveling distance from a floor to the next is more than 11 m, make an opening on the hoistway wall
9. between the floors and install emergency exit doors in the opening for passenger evacuation.
10. It is advised that there is no human access to the space below the hoistway pit.
11. When the bottom of a hoistway pit is deeper than the required level, add backfill concrete up to the required level.
12. Provide and install a pit ladder based on the layout drawings.
13. Provide and install a power switching / distributing board in the hoistway.
Provide and install electrical pipes, wires, and leads in the hoistway. They shall be extended from the power
14. switching / distributing board to the controller, machine, and their related apparatuses.
Provide and install all of electricity supply apparatuses (inclusive of pipes, leads, wires, etc.) on various routes from the
15. building’s electricity supply system to the hoistway, landing floors and Fujitec-designated locations.
16. Install air ventilator(s) and/or air conditioner(s) in order to keep the hoistway temperature between 5 ºC (41 ºF) and 40 ºC (104 ºF).
Install lighting equipment of 30 watt or more at 7-meter intervals inside the hoistway with 0.5-meter clearance at the top and bottom of the hoistway.
18. The lighting intensity is required to be 50 lux or more at the car-top working platform and at the 1-meter high position above the pit bottom.
19. Make holes in the walls of a hoistway for Fujitec’s installation of machine support beams and fill concrete into the gap between the walls and the fixed beams.
20. Cut out landing walls and install emergency operation panels for Fujitec’s emergency access to and operation of elevator machine and brake.
21. Install machine lifting hooks and / or beams on the hoistway’s ceiling slabs. The required lifting load capability is stated on the relevant installation drawings.
Others
1 Ground-fault circuit interrupter and current leakage alarm are required to be protected against current-harmonic distortion.
2 Lay building’s telecommunication lines 500 mm away from the electric feeder lines for elevator system.
6 Provide a storage room in order to stock elevator parts and installation materials.
7 Do not place any tools and materials not related to elevators in the hoistway.
36
Global Operations
EAST ASIA
HUASHENG FUJITEC ELEVATOR CO., LTD.
SHANGHAI HUASHENG FUJITEC ESCALATOR CO., LTD.
FUJITEC SHANGHAI SOURCING CENTER CO., LTD.
FUJITEC SHANGHAI TECHNOLOGIES CO., LTD.
FUJITEC (HK) CO., LTD.
FUJITEC KOREA CO., LTD. ,
FUJITEC TAIWAN CO., LTD.
EUROPE
FUJITEC UK LTD.
JAPAN
MIDDLE EAST
FUJITEC SAUDI ARABIA CO., LTD. FUJITEC PACIFIC, INC.
FUJITEC CO.,LTD. UAE (DUBAI) OFFICE
FUJITEC EGYPT CO., LTD.
SOUTH ASIA
FUJITEC SINGAPORE CORPN. LTD.
FUJITEC INC. (PHILIPPINES)
FUJITEC (MALAYSIA) SDN. BHD.
P.T. FUJITEC INDONESIA
FUJITEC INDIA PRIVATE LTD.
FUJITEC VIETNAM CO., LTD.
FUJITEC (THAILAND) CO., LTD.
FUJITEC LANKA PRIVATE LTD.
FUJITEC MYANMAR CO., LTD.
FUJITEC AMERICA, INC. Big Wing (Japan) Big Step (Japan) FUJITEC INDIA PRIVATE LTD.
37
In the 1960’
…S
and sought for global development of its business. Since then, we have helped
… Production Base
build cities all over the world and continue to develop our business aggressively
NORTH AMERICA
FUJITEC AMERICA, INC.
FUJITEC CANADA, INC.
HUASHENG FUJITEC SHANGHAI HUASHENG FUJITEC FUJITEC KOREA CO., LTD. FUJITEC TAIWAN CO., LTD.
ELEVATOR CO., LTD. ESCALATOR CO., LTD.
38
REX180132AS
Machine-Room-Less Elevator
■ Planning
■ Standard Dimensions
■ Power Supply Data
Standard (Left Side of the Narrow Jamb) Standard (Right Side of the Narrow Jamb)
Optional (Left Side of the Wide Jamb) Optional (Right Side of the Wide Jamb)
2
Planning
EOP Floor
The Other Floors except Bottom Terminal Floor and EOP Floor
3
Standard Hole Plan at landing to comply with EN81-70 Requirments;
-With optional landing fixtures (Box type fixtures)
All Floors except EOP Floor
EOP Floor
4
Planning
EOP Floor
The Other Floors except Bottom Terminal Floor and EOP Floor
5
Standard Hole Plan at landing (non-EN81-70) ;
-With optional landing fixtures (Box type fixtures)
All Floors except EOP Floor
EOP Floor
6
Standard Dimensions
WIDE CAR
Pit reaction
Maximum Car Inside Opening Hoistway Pit Depth Overhead (kN)
Capacity Speed Opening
Travel AxB WxH XxY P OH R3 R4
(kg) (m/s) Type R1 R2
(mm) (mm) (mm) (mm) (mm) (mm)
short-term short-term short-term long-term short-term long-term
1 1350 4150
2 1530 4450
1 1430 4150
2 1720 4450
1200 1.75 90 2CO 1800 x 1500 1100 x 2100 1530 4350 151 126 129 119 0 131
2560x1790
2 1680 4450
1350 1.75 90 2CO 2000 x 1500 1100 x 2100 2690x1790 1650 4350 163 135 132 121 0 133
2 1800 4450
2 1760 4450
2790x2200
2.5 2220 4690
2 1810 4450
3060x2300
2.5 2260 4690
Note:
1. Hoistway Tolerance;
- Horizontal dimensions : Refer to WORK BY OTHERS.
- PIT Depth : +50 ~ 0 (plus 50 ~ minus 0)
- Travel : +100 ~ 0 (plus 100 ~ minus 0)
2. The data shown in the table above considers following elevator specificaitons;
- Travel: Max. travel (see the table above), Non seismic, Hoistway of X x Y (see the table above for X and Y) enclosed by wall (i.e. single hatch).
- 2350mm clear height car with CT-GS01, 25mm marble floor recess (by other), COB-GC01, CPH-GC02, Upper-side Full-width Mirror.
- Without counterweight safety, without metal duct.
Please contact our local office for details because the data may vary depending on elevator specifications, elevator shaft configuration,
and also local code (for example, seismic zone).
3. EN Fire door can be provided with the enlargement of Hoistway dimensions: X+50 and Y+20. (See the table above for X and Y)
4. The size of car with *4 corresponds with minimum car dimensions for Type 3 lift specified by EN81-70.
7
Plan for wide car
8
Standard Dimensions
DEEP CAR
Pit reaction
Maximum Car Inside Opening Hoistway Pit Depth Overhead (kN)
Capacity Speed Opening
Travel AxB WxH XxY P OH R3 R4
(kg) (m/s) Type R1 R2
(mm) (mm) (mm) (mm) (mm) (mm)
short-term short-term short-term long-term short-term long-term
1 1290 3750
1.5 1370 3870
450 90 2S 1000 x 1200 800 x 2100 1630x1630 84 75 82 78 0 85
1.75 1420 3950
2 1490 4050
1 1290 3750
2000 1.75 90 2S 1500 x 2700 1200 x 2100 2210x3060 1620 4350 208 167 168 154 0 164
2 1760 4450
9
Plan for narrow car
10
Power Supply Data
Note:
1. The data shown above may vary based on elevator specification arrangement.
2. Earthling wires shall be arranged and installed based on local elevator code requirement.
11 3. The data shown above is when power supply is 400Vac, 50Hz.
Memo
12
13
REX180132AS