Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

3306 180KW PR

Download as pdf or txt
Download as pdf or txt
You are on page 1of 4

Generator 225 kV•A

1500 rpm
Set 50 Hz

Prime Power

Caterpillar is leading the power generation


marketplace with Package Generator Sets
engineered to deliver unmatched flexibility,
expandability, reliability, and cost-effectiveness.

Shown with
Optional
Equipment

FEATURES

■ COMPLETE, READY-TO-RUN SYSTEM ■ CAT ® 3306 DIESEL ENGINE


• Full-featured system includes: integral fuel • Reliable, rugged, durable design
tank base, exhaust silencer and flex, • Field-proven in hundreds of thousands of
charging alternator, batteries, battery rack applications worldwide
and cables, and main line circuit breaker
• Four-stroke-cycle diesel engine combines
• Fully operable upon delivery, just add fuel consistent performance and excellent fuel
and power cables economy with minimum weight
■ FULL RANGE OF ATTACHMENTS
• Wide range of bolt-on system expansion
attachments, factory designed and tested ■ CAT ® SR4B GENERATOR
• Designed to match performance and
■ SOUND ATTENUATED ENCLOSURE output characteristics of Caterpillar diesel
• Factory complete, ready-to-run (optional) engines
■ SINGLE-SOURCE SUPPLIER • Optimum winding pitch for minimum total
• Complete systems designed and built at harmonic distortion and maximum
Caterpillar ISO certified facilities efficiency
• Certified Prototype Tested with torsional • Segregated AC/DC, low voltage accessory
analysis box provides single point access to
accessory connections
■ WORLDWIDE PRODUCT SUPPORT
• Worldwide parts availability through the
Caterpillar dealer network
• With over 1,200 dealer outlets operating in
■ CAT ® CONTROL PANELS
166 countries, you’re never far from the • Three levels of controls, designed to meet
Caterpillar part you need. individual customer needs
• 99.5% of parts orders filled within • Common enclosure and wiring harness
48 hours. The best product support record equipped with quick disconnects allows
in the industry. easy retrofit
• Caterpillar dealer service technicians are • Switchgear conversion and
trained to service every aspect of your electromechanical panels provide
electric power generation system. accurate analog monitoring and metering
with basic system protection
• Preventive maintenance agreements
• Microprocessor based Electronic Modular
• The Cat Scheduled Oil Sampling (S•O•SSM) Control Panel (EMCP II and EMCP II+) use
program cost effectively detects internal digital gauges and true RMS monitoring
engine component condition, even the to provide advanced monitoring,
presence of unwanted fluids and metering, control, and protective relaying
combustion by-products capabilities. Fully compatible with
■ MEETS OR EXCEEDS INTERNATIONAL Caterpillar annunciators, and remote
communication and expansion modules.
SPECIFICATIONS: ABGSM TM3,
AS 1359, AS2789, BS4999, BS5000,
BS5514, DIN6271, DIN6280, EGSA101P,
IEC 34/1, ISO3046/1, ISO8528,
JEM1359, NEMA MG1-22, VED0530,
89/392/EEC, 89/336/EEC
225 kV•A GENERATOR SET

FACTORY INSTALLED STANDARD & OPTIONAL EQUIPMENT

SYSTEM STANDARD OPTIONAL


Air inlet modular air cleaner, single element dual element air cleaner
with dust evacuator heavy-duty air cleaner
service indicator air inlet shutoff

Cooling radiator with guard radiator duct flange


coolant drain line with valve jacket water heater with isolation valves
fan and belt guards low coolant level alarm and shutdown
Caterpillar Extended Life Coolant heat exchanger and expansion tank

Exhaust stainless steel exhaust flex with residential muffler


mating weld flange critical muffler
industrial grade muffler muffler mounting kit, through-wall
installation kit
engine exhaust guarding

Fuel primary fuel filter water separator


secondary fuel filter manual transfer pump
fuel priming pump automatic transfer systems,
fuel pressure gauge 3 configurations
flexible fuel lines low fuel level alarm and shutdown

Generator self excited permanent magnet excitation


class F temperature rise 2:1 Volts/Hz AVR
105° C (221° F) prime Digital Voltage Regulator (D.V.R.)
circuit breaker, IEC compliant D.V.R. with KVAR/PF control
3-pole with shunt trip space heater
reactive droop kit
oversize and premium generators
circuit breaker, IEC compliant, 4-pole with
shunt trip

Governor hydra-mechanical electronic isochronous and load sharing

Control panels EMCP II electromechanical auto start/stop panel


switchgear conversion
EMCP II+
system expansion modules

Lube lubricating oil manual sump pump


oil drain line with valves
fumes disposal

Mounting formed steel base with integral wide base with integral fuel tank
fuel tank, 8 hour capacity – minimum extended capacity fuel tank base
linear vibration isolators between skid base
base and engine-generator

Starting/ 45 amp charging alternator integral 5 amp battery charger


charging Energize To Run (ETR) fuel oversize batteries
shutoff solenoid ether starting aid
24 volt starting motor battery disconnect
batteries with rack and cables

Other enclosures – sound attenuated, weather


protective
automatic transfer switch
CE certification
225 kV•A GENERATOR SET

TECHNICAL DATA

225 kV•A/180 kW Prime Power Generator Set – 1500 rpm/50 Hz


Package Performance
Power rating @ 0.8 PF with fan kV•A 225
Power rating @ 0.8 PF with fan kW 180

Fuel Consumption
100% Load with Fan L/hr 51.1
75% Load with Fan L/hr 38.6

Cooling System
Ambient Air Temperature (Consult T.M.I.)
Designed for operation up to Deg C 50
Air Flow Restriction (After Radiator) kPa .06
Standard Radiator Arrangement Data
Air Flow (Max @ Rated Speed) m3/min 319
Engine Coolant Capacity with Radiator L 68.9
Engine Coolant Capacity without Radiator L 15.9

Exhaust System
Combustion Air Inlet Flow Rate m3/min 13.7
Exhaust Gas Stack Temperature Deg C 571
Exhaust Gas Flow Rate m3/min 41.0
Exhaust Flange Size — (Internal Diameter) mm 152
System Backpressure (Max. Allowable) kPa 6.7
Heat Rejection
Heat Rejection to Coolant (Total) kW 111
Heat Rejection to Exhaust (Total) kW 192
Heat Rejection to Atmosphere from Engine kW 48
Heat Rejection to Atmosphere from Generator kW 16.8

Deration: Generator set is designed to operate in ambient temperatures up to 50° C (122° F) and at higher
altitudes. Please consult factory for available outputs.

CAT® 446 FRAME GENERATOR CAT® 3306 TA ENGINE


SPECIFICATIONS SPECIFICATIONS
Type . . . Self excited, static regulated, brushless I-6, 4-Stroke-Cycle Watercooled Diesel
Construction . . . . Single bearing, close coupled Bore — mm (in) . . . . . . . . . . . . . . . . . . . . 121 (4.75)
Three phase . . . . . . . . . . . . 12 lead reconnectable Stroke — mm (in). . . . . . . . . . . . . . . . . . . . 152 (6.0)
Insulation. . . . . . . . . . Class H with tropicalization Displacement — L (cu in). . . . . . . . . . . . 10.5 (638)
and antiabrasion Compression ratio . . . . . . . . . . . . . . . . . . . . . . . 15:1
Enclosure . . . . . . . . . . . . . . . . . . . . . Drip proof IP22 Aspiration. . . . . . . . . . Turbocharged-Aftercooled
Alignment . . . . . . . . . . . . . . . . . . . . . . . . . Pilot shaft
Overspeed capability . . . . . . . . . . . . . . . . . . . 150% CAT® CONTROL PANEL
Wave form . . . . . . . . . . . . Less than 5% deviation
24 Volt DC Control
Paralleling capability . . . . . . . . . . . . With optional
NEMA 1, IP22 enclosure
droop transformer
Electrically dead front
Voltage regulator . . . . . . . . 3-phase sensing with
Lockable hinged door
Volts-per-Hertz
Generator instruments meet ANSI C-39-1
Voltage regulation Less than ±1/2% (steady state)
Terminal box mounted
Less than ± 1% (no load to full load)
Single location customer connector point
Voltage gain. . . . . Adjustable to compensate for
EC compliant — segregated AC/DC connection
engine speed droop and line loss
TIF . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Less than 50
Consult your Caterpillar dealer for available
THD . . . . . . . . . . . . . . . . . . . . . . . . . . . . Less than 5%
voltages.
225 kV•A GENERATOR SET

PRIME POWER GENERATOR SET PACKAGE — TOP VIEW

FUMES
DISPOSAL

OIL FILTER FUEL


CONTROL PANEL AIR INLET DRAIN

ELECTRICAL
STUB-UP FUEL FILL FUEL OIL DRAIN
FILTER COOLANT
DRAIN
EXHAUST

PACKAGE DIMENSIONS
Length mm 3800
Width mm 1100
Height mm 1930
Shipping Weight kg 3070

Note: General configuration not to be used for


installation. See general dimension
drawings for detail.

RATING DEFINITIONS AND CONDITIONS


Prime — Output available with varying load for Fuel rates are based on fuel oil of 35° API (16° C
an unlimited time. Prime power in accordance or 60° F) gravity having an LHV of 42 780 kJ/kg
with ISO8528. 10% overload power in (18 390 Btu/lb) when used at 29° C (85° F) and
accordance with ISO3046/1, AS2789, DIN6271, weighing 838.9 g/liter (7.001 lbs/U.S. gal.).
and BS5514 available on request.
Additional ratings may be available for specific
Ratings are based on SAE J1349 standard customer requirements. Consult your Caterpillar
conditions. These ratings also apply at representative for details.
ISO3046/1, DIN6271, and BS5514 standard
conditions.

Materials and specifications are subject to change without notice. The International System of Units (SI) is used in this publication.
LEHX7024-02 Printed in U.S.A. © 1998 Caterpillar Inc.
All rights reserved.

You might also like