EGCS maintenance manual

介于设备使用中,偶尔会出现一些小故障,为了
客户在使用阶段出现问题能够快速效率的解决问题,
现做了如下相关维护要点:
Because of the equipment failures will
occasionally occur when the equipment is in use,
we make the following maintenance requirements
for solving problem more effectively:

after-saleservice@zeme-china.com 1
浙江浙能迈领环境科技有限公司 EGCS maintenance manual

第一部分 EGCS 设备报警消除

EGCS device alarm elimination

一. SO2/CO2 超过设定值(特定排放海域≥4.3,一般排放海域≥21.7)
I. SO2/CO2 exceeds the current standard (special areas≥4.3, common
areas≥21.7)
1. 如果船舶在开式模式下投入 PID 运行,硫碳比一直无法满足正常数
值,循环泵会撤出 PID 控制,循环泵频率会加到最大至 60HZ
1. If the vessel is in open loop mode, carbon ratio in exhaust gas
cannot reach the satisfied value, and the circulation pump runs
under full load amps for X minutes, the system will automatically
shift from open loop to close loop.
2. 当循环泵增大至最大频率运行一段时间后,硫碳比仍然无法达标的
情况下,则需要人为主动降低主机负荷或者船员选择将重油转换低硫油
2. When system converts to close loop, the carbon dioxide value
is still below the standard, it is necessary to manually reduce
the load of main engine, or use low sulphur fuel oil instead.
3. 联系 ZEME 售后人员对系统进行排查
4. Contact ZEME after-sales for system investigation.
二、MGPS 报警
1.到本地检查控制箱的铜棒铝棒显示值是否正常,铜棒的电流值设定为
1.3A,铝棒的电流值设定为 0.8A
三、洗涤后烟气温度
II. The gas temperature out of the scrubber
洗涤后烟气温度 TT103 温度高于 80 度,延时 15 秒,二级报警,当烟气
温度高于 100 度,延时 15 秒,一级报警,紧急停机。
1. If the temperature is higher than 80 delay 30s, an H value alarm
would be sounded, if the temperature is higher than 100, delay 30s,
an HH value alarm would be sounded and shut down the EGCS
2. 当出现此温度报警时,首先确认洗涤塔入口前烟气温度 TT102 是否
过高,由于原船设备导致的烟气温度过高,需要停止烟气继续进入洗涤
塔,排查出原船设备问题
1. If high temperature alarm alerts, firstly, check whether the
temperature of exhaust gas, before filling into scrubber, is
unmorally high. If the high temperature is caused by the equipments
from shipowner, gas needs be stopped entering the scrubber until
troubleshot.
3. 确认预喷淋后烟气温度 TT101 温度是否正常,正常情况下预喷淋后
温度 TT101 为 50 度左右,然后检查预喷淋管路压力表及洗涤母管压力变
送器、压力表、流量计显示是否正常,确认预喷淋及主喷淋层的水量是

2 after-saleservice@zeme-china.com
EGCS maintenance manual 浙江浙能迈领环境科技有限公司

否充足,如因压力不够导致的温度高,则需要确认是否喷头堵塞导致或
者是海底门滤器堵塞。
4. Check pressure transmitter and pressure gauge on spray
pipeline; confirm the quantity of water in pre-spray layer. If high
temperature is due to insufficient pressure, it is necessary to
examine nozzle blocking.
三、洗涤塔入口烟气压力
洗涤塔入口烟气压力 PT103 高于 2600pa,会触发二级报警

四、洗涤塔压差报警
III. Differential pressure alarm of scrubber
洗涤塔烟气入口压力减去洗涤塔出口压力 PT103-PT104:压差高报警为
2600Pa,压差高高停机为 2800Pa。
The differential pressure between inlet and outlet of scrubber:
high differential pressure alarm is 2600Pa, and high-high
differential pressure alarm, which pause the engine, is 2800Pa.
1. 洗涤塔压差高于 2200pa,延时 30 秒,系统会自动进入洗涤塔差压高
冲洗程序。
1. If the differential pressure of the scrubber is higher than 2400
PA, and lasts for 30 second, the system will automatically open
washing system.
2. 当反复冲洗洗涤塔压差报警仍然无法消除,则需要确认除雾器是否
堵塞严重
2. If the alarm cannot be removed after repeated flushing, then
check whether the demister is blocked seriously.
3. 确认烟气进口以及烟气出口的压力传感器探头是否干净,探头被烟
垢堵塞会导致传感器不准确误报警
3. Both probes of pressure transmitter in inlet and outlet of
exhaust gas are supposed to be clean, as if probes are blocked by
dirt, they will alarm inaccurately.

二. 密封风机出口压力
IV. Outlet Pressure of seal fan
密封风机出口压力 PT102 低压切换为 1.2Kpa,压力低报警为 1.2Kpa.当
PT102 的压力低于 1.2Kpa 时,会启动备用风机。
Low pressure alarm of the seal fan is 1.2Kpa, and the low-low
pressure alarm is 1Kpa.
1. 当密封风机压力低于 1.2Kpa 时,系统会自动运行备用风机;如果备
用风机打 开后,压力仍然没法满足,则需要人为现场勘查风机机械
部分
1. When pressure of the seal fan is less than 1.2Kpa, system will
open boost fan; if the pressure still cannot meet the standard even

after-saleservice@zeme-china.com 3
浙江浙能迈领环境科技有限公司 EGCS maintenance manual

after turning on boost fan, the mechanical part of the fans should
be inspected manually.
2. 检查密封风机总管路上压力表值是否正常,排除压力传感器是否故

2. Check the value of pressure gauge on the process line, excluding
the failures on pressure transmitter.
3. 确认烟气挡板的状态,如果烟气排大气和进洗涤塔的挡板都开着,
会导致压力 上不来,说明挡板门卡住
3. Check the damper of exhaust gas. If both dampers, one touching
with the air and another connecting with scrubber, are open in the
meantime, it will cause low pressure in scrubber, implicating
dampers are stuck.

五. 洗涤塔液位高、液位高高
V. High and high-high liquid level of scrubber LS101、LS102
注:洗涤塔本体安装了三个液位报警,最下面的一个是洗涤塔液位报警,
只作为普通的液位报警,中间一个是洗涤塔液位高报警,最上面的一个
洗涤塔液位高高报警,上面两个浮球均为一级报警,任一一个触发都导
致洗涤塔停机。如果系统不停机,会导致洗涤塔内的水继续增长倒灌入
辅机以及主机内部,对设备的损坏是巨大的!
Note: Two liquid level alarms are installed in the scrubber. Both
of them are first alert. Once any of them is triggered, scrubber
will shut down immediately, or the water in scrubber will
continuously grow, and pour back into the auxiliary engine and main
engine, this will result in catastrophically damage on equipments.
1.洗涤塔系统运转前,一定要确认排舷外的手动阀 HMV02、03、04 是打
开状态
六.洗涤水喷淋母管压力
VI. Pressure of praying process line
只有在洗涤塔系统在运行中,洗涤塔喷淋母管压力低报警才会触发,PLC
已经设定了自动模式下最低循环泵频率
Low pressure alarm of spraying pipeline occurs while scrubber
operates with the lowest frequency circulation pump.
1. 检查循环泵的吸入压力是否有真空,确认无管路无漏气
1. Check the status of circulation pump avoiding vacuum, ensure
there is no pipeline leakage.
2. 检查洗涤水进口液压阀 HMV01 是否是全开状态
2 Electric valve ELV01 or ELV02 at the suction of circulation
pump is turning on.
3. 确认海底门滤器是否堵塞,观察海水滤器前后压力表的差值
3. Ensure the sea chest filter is not blocked; observe the
differential pressure switch alarm.

4 after-saleservice@zeme-china.com
EGCS maintenance manual 浙江浙能迈领环境科技有限公司

七 洗涤水温度高
VII.High temperature of washwater
洗涤水温度高报警为 40℃
High temperature alarm of washwater is 80℃(176℉).
1. 开式循环下温度高,说明海底门过来的水温就高,所以开式情况一
般不会出现洗涤水高温情况
1. High temperature of washwater in open loop is caused by the high
temperature water coming from sea chest; generally speaking,
temperature will not be alarmed under open loop system.

八.洗涤水流量
VIII. Flow of washwater
洗涤水流量低于 250 m³/h 会触发洗涤水流量低报警,直接导致脱硫效果
下降。
1. 检查循环泵的出口压力是否正常
2. 检查洗涤水进口液压阀 HMV01 是否是全开状态
3.检查主喷淋层每一层的喷淋层压力表是否有压力

十.仪用压缩空气压力
X. Pressure of instrument control compressed air
仪用压缩空气接入原船的控制空气系统,正常情况下压力变送器显示为
700Kpa,仪控压缩空气压力低报警为 450Kpa,
Low pressure alarm of instrument control compressed air is 450Kpa,
which will impact the system.
1. 确认原船空气瓶是否有气,到仪控压缩空气管路的阀是否打开
1. Compressed air machine is in good working conditions.
2. 确认原船空气是否正常
2. Normal status of compressed air.
注:压缩空气低压会导致 CMES 系统无法正常工作,导致挡板门无法正
常速度开关,导致系统程序进行不下去,所以一定要确保压缩空气的正

Note: Low pressure of compressed air will influence the function
of CMES system, and then dampers cannot switch within common speed.
Therefore, it is essential to check the status of compressed air
for preventing the system arrests.

十一.水质分析单元故障
XI. Faults in treated water sampling & analysis unit
开式: PAH>20µg/L(水质前减去水质后)
Open loop: PAH > 20 g/L (UWSA unit minus TWSA unit)

after-saleservice@zeme-china.com 5
浙江浙能迈领环境科技有限公司 EGCS maintenance manual

混合式:PAH>850µg/L(水质前减去水质后)
Hybrid: PAH > 850 g/L (UWSA unit minus TWSA unit)
浊度>23NTU(水质前减去水质后)
Turbidity > 23NTU (UWSA unit minus TWSA unit)
处理后 PH<2.8
After treatment, PH < 2.8
1. 水质分析单元流量低报警
1. Low flow alarm of TWSA unit
确认原船吃水是否高于 10 米,如果高于 10 米,会导致水排不出去,因
水质分析单元内部有调压阀,压力只有 1 公斤。外面吃水高于 10 米,会
导致压强高于 1 公斤,导致水质分析单元水排不出来而没有流量。可以
适当的调整吃水,如果工况不满足调整,可以临时把水质分析单元出口
管拆掉,让水正常流通即可
Check the draught of the vessel; if it is higher than 10 meters,
the water cannot be drained out because of the compression valve
in the TWSA unit, with only 1 kg-pressure. As long as the draught
is higher than 10 meters, the pressure will exceed 1 kg, and then
flow of water in TWSA unit is hard to discharge overboard. If
conditions are not satisfied with the adjustment of draught,
temporarily remove TWSA unit, allowing regular flow rate in units.

确认水质分析单元内部 Y 型滤网是否堵塞,可以拆开进行清洗
Check Y-strainer blocking, disassemble it for sanitation.
2. 水质不达标报警(PH,PAH,浑浊度超标)
2. Alarm of water quality (PH, PAH, turbidity exceed standard)
检查循环泵是否自动满负荷运转
Check whether the circulation pump runs at full load
automatically
检查舷外阀是否全开,保证流速
Check whether the overboard valves are fully open with normal
flow rate.

十二.循环泵电流
XII. Circulation pump electricity
循环泵高电流报警为>320A
High current alarm of circulation pump is over 320A
1. 检查各循环泵吸口阀是否全开状态
1. Turn on each suction valves of circulation pump.
2. 检查泵本体自身是否发烫,确认叶轮是否卡死
2. Check whether the pump itself is heated, as well as stuck
impellers.
3. 检查循环舱水是否低液位

6 after-saleservice@zeme-china.com
EGCS maintenance manual 浙江浙能迈领环境科技有限公司

3. Check low liquid level of recycle tank.


十三. PLC 系统运行不起来
XIII. Failures on PLC system.
1. 检查泵就地遥控按钮的应急停是否复位
1. Reset the local emergency stop of metering pump.
2. 检查海水滤器压差是否报警
2. Check alarms of differential pressure transmitter of sea water.
3. 检查各个设备的烟气主挡板门和烟气旁通挡板门,保证一个是开
的,一个是关的
3. Check main gas damper and bypass damper of all equipment,
ensuring one of these is open and the other is closed.
4. 检查舷外阀指示是否为打开状态
4. Examine whether the overboard valve is open
5. 检查 PLC 控制箱应急停是否复位
5. Reset emergency stop of PLC system.
6. 检查开式模式下所有的阀门,挡板,水质分析仪,CMES 系统无报警
6. Check all valves, dampers, water sampling & analysis units and
CMES system under open loop system.
7. 检查闭式模式下所有的阀门,挡板,水质分析仪,CEMS 系统,废水
处理装置,循环舱液位,滤液箱液位,氢氧化镁舱液位,储存箱液位无
报警
7. Check all valves, dampers, water sampling & analysis units, CEMS
system, water treatment equipment, as well as liquid level of
recycle tank, filter tank, Mg(OH)2 tank, holding tank under close
loop system.
8. 检查开式以及闭式模式下的阀门都是打开状态
8. Check whether all valves are turning on in both open loop and
close loop.
9. 检查 PLC 控制屏上模式是否在自动状态下
9. Check the automatic mode on the PLC control panel.
10. 检查氢氧化镁围堰液位,洗涤塔围堰液位,洗涤塔高高液位是否被
触发
10. Inspect whether the cofferdam liquid level of Mg(OH)2 ,
scrubber, and high liquid level of scrubber are triggered.

十四.挡板门故障或者挡板门无法正常操作
XIV. Failures or abnormal operation of dampers.
1. 检查挡板门压缩空气是否正常
1. Check compressed air of dampers.
2. 检查挡板门压缩空气是干燥的
2. Ensure the compressed air of dampers is dry.
3. 挡板门转到手动操作,手动开关确认阀门是否卡死

after-saleservice@zeme-china.com 7
浙江浙能迈领环境科技有限公司 EGCS maintenance manual

3. Switch to manual operation; manually examine whether the valve


is stuck.
4. 挡板门调压阀处压力表压力是否满足,如果低于 5 公斤,但是原船压
力正常,则需要调整调压阀压力,正常工作压力要高于 6 公斤
4. If pressure gauge at the compression valve of dampers shows the
value is less than 5 kg, but that of the original vessel is
appropriate, then adjust the pressure of compression valve over
6kg.
5. 如挡板门手动可以操作,压缩空气也都正常,那么确认电磁阀是否正
常供电,确认电磁阀是否损坏
5. If dampers can be operated manually and the compressed air is
normal, then confirm whether the solenoid valve is powered without
problem.

十五. 电动阀门出现故障或者无法正常操作
XV. Failure or abnormal operation of electric valves
1. 检查电动阀门电源是否正常
1. Check the power supply of electric valve.
2. 检查电动阀门就地操作是否可以开关,确认其是不是卡死
2. Check whether the switch of electric valve local process is
blocked.
3. 检查电动阀门遥控和就地转换开关是否在遥控状态
3. Check whether the electric valve and the switch of electric
valve local process can be remotely controlled.
4. 检查驱动头和电动阀门
4. Check the motor and electric valve.

十六. 舱室液位高
XVI. High liquid level of tank.
循环舱液位高:液位高报警会导致系统无法运行,那么就需要手动把舱
室内的水排至正常液位
High level of recycle tank: High liquid level alarm will stop the
system, which needs manually pump out water in tank to the normal
liquid level.
1. 手动打开循环舱到循环泵吸口的 STSV31 手动蝶阀
1. Switch on STSV31 manual butterfly valve from recycle tank to
the circulation pump.
2. 手动打开循环泵入口电动阀 ELV02
2. Manually turn on ELV02 at the inlet of the circulating pump.
3. 手动打开排海电动阀 ELV21
3. Manually open ELV21
4. 手动选择任一一台循环泵并启动泵开式排水,排水过程中观察循环舱

8 after-saleservice@zeme-china.com
EGCS maintenance manual 浙江浙能迈领环境科技有限公司

的液位,液位正常,关闭泵并复位上述阀门
5. Select any one of the circulation pumps, and start drainage with
open loop. Observe the liquid level of the recycle tank as water
draining out. Close the pump and reset all valves until the liquid
level changes to normal condition.

十七. 缓存箱液位高:缓存箱液位高只能人为的选择外排或者不外排,首先
要确认其是否在可排放海域
XVII High liquid level of holding tank: To solve high liquid level
of holding tank, it can only be selected to discharge overboard or
not, first of all, inspect whether it is emission control area.
1. 驾驶室分显板“非美国海域”是否被激活状态
1. "Non-geographic sea areas of United States" is activated on
panel of operator cabin.
2. 循环箱液位是否满足排放高度
2. Recycle tank satisfies the discharge height
3. 处理后水质分析单元是否在工作状态并且没有报警
3. TWSA unit is in working conditions without alarm.
4. 点击控制面板上缓存箱水外排模式,则系统会自动开阀以及开泵开
式排水
4. Open overboard discharge mode of holding tank on control panel,
then the system will automatically switch on the valve and
discharge water by open loop system.

十八. CEMS 故障排查


XVIII. CEMS troubleshoot
1. CEMS 温度高报警:需要确认 CEMS 房间环境温度如何
CEMS High Temperature Alarm: Check the ambient temperature
of CEMS.
2. CEMS 出现维护报警:检查控制空气压力是否低压,低压会导致系统
故障
Failures alarm of CEMS: Check whether the low air pressure
causes system failure.
3. CEMS 有时候会出现流量低报警,说明滤器堵了
CEMS sometimes has a low flow alarm, indicating that the filter
is blocked

after-saleservice@zeme-china.com 9
浙江浙能迈领环境科技有限公司 EGCS maintenance manual

第二部分:CEMS 一般维护

Part two: general CEMS maintenance

一.连接 SOPAS 软件

Connect to the SOPAS software

1. 用电脑登录 https://www.sick.com/cn/en/ 网站,在搜索栏里面输入“SOPAS


ENGINEERING TOOL”,选择“SOPAS ENGINEERING TOOL 2020(PORTABLE-VEESION)”
软件进行下载
Use a computer to log on to https://www.sick.com/cn/en/ website, in the search
bar enter "SOPAS ENGINEERING TOOL", select "SOPAS ENGINEERING TOOL
(PORTABLE - VEESION) 2020" software to download

10 after-saleservice@zeme-china.com
EGCS maintenance manual 浙江浙能迈领环境科技有限公司

2. 用一根网线连接电脑和设备端口
Connect the computer to the device port with a network cable

松开分析仪四个螺丝,打开门,可以看到连接网线的端口
Loosen the analyzer's four screws, open the door, and see the port connecting the
network cable

after-saleservice@zeme-china.com 11
浙江浙能迈领环境科技有限公司 EGCS maintenance manual

3. 下载安装之后,点击桌面的 SOPAS 快捷菜单进入系统


After downloading and installing, click the shortcut menu of SOPAS on the
desktop to enter the system

12 after-saleservice@zeme-china.com
EGCS maintenance manual 浙江浙能迈领环境科技有限公司

4. 添加搜索到的设备 DEFOR,BCU 到目录,(双击进入)


Add the searched device DEFOR,BCU to the directory, (double-click to enter)

after-saleservice@zeme-china.com 13
浙江浙能迈领环境科技有限公司 EGCS maintenance manual

5. 登录 Service,密码 hidden
Login: Service
password :hidden

14 after-saleservice@zeme-china.com
EGCS maintenance manual 浙江浙能迈领环境科技有限公司

6. 登录 DEFOR,点击 DIAGNOSIS,查看加热 4 温度,确认这个温度是多少度,一般


温 度 是 在 60-62 度 , 如 果 温 度 低 于 60 度 , 就 会 来 维 护 报 警
(Defor-diagnosis-meaters-heater4)
Log in DEFOR, click DIAGNOSIS, check the temperature of heating 4, and confirm
the temperature of heating 4. Generally, the temperature is 60-62 degrees. If the
temperature is lower than 60 degrees, an alarm will be
maintained.(Defor-diagnosis-meaters-heater4)

after-saleservice@zeme-china.com 15
浙江浙能迈领环境科技有限公司 EGCS maintenance manual

7.修改误差范围,默认+0.5/-0.5(进入 Factary settings-contral circuit 4),修改


heatering
Modify the range by default +0.5/-0.5 (enter Factary settings-contral circuit 4) to
modify heatering

16 after-saleservice@zeme-china.com
EGCS maintenance manual 浙江浙能迈领环境科技有限公司

8.修改结束之后,确认维护报警是否消除
After the modification, confirm whether the maintenance alarm is eliminated

9. 保存文件,附带 CEMS 分析仪上面的 PN/SN,发邮件给我


Save the file and email me,The serial number of the analyzer is attached

after-saleservice@zeme-china.com 17
浙江浙能迈领环境科技有限公司 EGCS maintenance manual

二.CEMS 问题诊断

CEMS problem diagnosis

1. 进入 SOPAS 软件之后,会出现 BCU,DEFOR 等目录,选择一个 BCU 目录后登陆


After entering SOPAS software, BCU,DEFOR and other directories will
appear. Select a BCU directory and log in

2. 登陆密码 password
用户名 The user name:SERVICE
密码 password :HIDDEN

18 after-saleservice@zeme-china.com
EGCS maintenance manual 浙江浙能迈领环境科技有限公司

3. 进入之后,双击图框进入子菜单
After entering, double-click the graph box to enter the submenu

after-saleservice@zeme-china.com 19
浙江浙能迈领环境科技有限公司 EGCS maintenance manual

4. “BCU-DIAGNOSIS-LOGBOOK”可以确认详细的问题,主要确认状态在 ON 的
The "bcu-diagnostic-logbook" identifies the problem in detail, primarily
identifying the state “ON”

5. 接着可以查看具体的项目清单对比什么问题
And then you can look at the list of specific items and what are the questions

20 after-saleservice@zeme-china.com
EGCS maintenance manual 浙江浙能迈领环境科技有限公司

after-saleservice@zeme-china.com 21
浙江浙能迈领环境科技有限公司 EGCS maintenance manual

22 after-saleservice@zeme-china.com
EGCS maintenance manual 浙江浙能迈领环境科技有限公司

after-saleservice@zeme-china.com 23
浙江浙能迈领环境科技有限公司 EGCS maintenance manual

24 after-saleservice@zeme-china.com
EGCS maintenance manual 浙江浙能迈领环境科技有限公司

after-saleservice@zeme-china.com 25
浙江浙能迈领环境科技有限公司 EGCS maintenance manual

三.CEMS 设备一般维护

General maintenance of CEMS equipment

1. CEMS 一般需要半个月校准一次,校准所用的标气需要有校准证书,船上需
要保证足够的校准气
CEMS generally needs to be calibrated once every half a month. The standard
gas used for calibration needs to have a calibration certificate, and the ship needs
to ensure sufficient calibration gas
2. 标气的型号
Standard gas model

3. 校准步骤
Calibration procedure
调零前的准备 Preparation before zero adjustment
将压力调节阀连接到氮气瓶上。
将氮气瓶连接到配电单元内电磁阀 KK1 的 P 口。
逆时针旋转关闭压力调节阀。
打开氮气瓶的阀门。
Connect the pressure regulating valve to the nitrogen gas bottle.
Connect the nitrogen bottle to port P of solenoid valve KK1 inside the
distribution unit.
Turn counterclockwise to close the pressure regulating valve.
Open the valve of the nitrogen gas bottle.

3.2 登录
菜单 » 登录 » Auth.操作员 » 密码: HIDE + 保存
Login
Menu→Login→Auth. operator→password: HIDE→Save

3.3 使用氮气瓶对 SO2 或 CO2 进行零点调整(因为氮气瓶内没有 SO2 和


CO2)

26 after-saleservice@zeme-china.com
EGCS maintenance manual 浙江浙能迈领环境科技有限公司

Zero Point adjustment for SO2 or CO2 with nitrogen gas bottle (Because there
is no SO2 and CO2 inside the nitrogen bottle)
Menu→Adjustments→Adjustment→SO2/CO2→Zero point adj.→Automatic?
→press Back→Zero point adj Start?→press “Enter”→Turn clockwise to open the
pressure regulating valve slowly and make sure the outlet pressure is less than 0.5
bar→press “MEAS” to go to the measuring screen→Adjust the flowmeter and
make the flow shown in the screen around 60L/H and stable→press “Menu” to go
back to the adjustment screen and wait for SO2 or CO2 value to be stable around 2
minutes→press “Enter” to measure for around 1 minute→press “Enter” to
calculate and the adjustment is finished.

3.4 标准气体调整前的准备工作
Preparation before reference point adjustment

将调压阀连接到 SO2 和 CO2 混合气瓶上。


将 SO2 和 CO2 混合气瓶连接到配电单元内电磁阀 KK1 的 P 口。
逆时针旋转关闭压力调节阀。
打开氮气瓶的阀门。
Connect the pressure regulating valve to the SO2 and CO2 mixture gas bottle.
Connect the SO2 and CO2 mixture gas bottle to port P of solenoid valve KK1
inside the distribution unit.
Turn counterclockwise to close the pressure regulating valve.
Open the valve of the nitrogen gas bottle.

3.5 SO2 和 CO2 混合气瓶对 SO2 或 CO2 的参考点调节


Reference point adjustment for SO2 or CO2 with SO2 and CO2 mixture gas
bottle
Menu → Adjustments → Adjustment → SO2/CO2 → Reference pt. adj. →
Automatic?→press “Back”→Reference pt. Start?→press “Enter”→Turn clockwise
to open the pressure regulating valve slowly and make sure the outlet pressure is less
than 0.5 bar→press “MEAS” to go to the measuring screen→Adjust the flowmeter
and make the flow shown in the screen around 60L/H and stable→press“Menu”to
go back to the adjustment screen and wait for SO2 or CO2 value to be stable around
2 minutes→press “Enter” to measure for around 1 minute→press “Enter” to
calculate and the adjustment is finished.
4. 取样探头滤器的维护
Maintenance of sampling probe filter

after-saleservice@zeme-china.com 27
浙江浙能迈领环境科技有限公司 EGCS maintenance manual

28 after-saleservice@zeme-china.com
EGCS maintenance manual 浙江浙能迈领环境科技有限公司

5. 取样气体内滤棉更换步骤
Sampling gas internal filter cotton replacement procedure

6. 常用备件更换清单
Replacement list of common spare parts

图示 一年 两年 五年
(One (Two (Five
PN Description EN 描述 (graphic
year years years
)
) ) )

207580
hose pump spare parts set 泵软管 2x 4x 10x
6

207396 Microfilter, complete


完整的微过滤器 4x 8x 20x
1 MARSIC200

after-saleservice@zeme-china.com 29
浙江浙能迈领环境科技有限公司 EGCS maintenance manual

531331
Water trap 脱水器 1x 2x 5x
7

208845 PTFE TFM, 泵中 PTFE 阀门备


\ 1x 2x
7 a set of valves for pump 件

207579 Sample gas pump


样气泵 230V \ 1x 2x
3 premounted, 230 V

207579 Sample gas pump


样气泵 115V \ 1x 2x
4 premounted, 115 V

532943
Glass fibre filter 0,1 µm 探头过滤器 4x 8x 20x
0

30 after-saleservice@zeme-china.com
EGCS maintenance manual 浙江浙能迈领环境科技有限公司

第三部分:水质分析仪

Part three: water quality analyzer

Malfunction and Maintenance

Cleaning and Upkeep


Before the sensors are validated, the TriBox3 must be set to service

mode so that the measured values are held at the outputs and there

are no malfunctions or incorrect values transferred.

To start service mode, select "Sensor" at the top right of the main menu and
then select "Sensor check" (bottom left).

after-saleservice@zeme-china.com 31
浙江浙能迈领环境科技有限公司 EGCS maintenance manual

1 General Information
1.1 Some contents of this manual require special warning, vigilance and attention.

Please read and follow these instructions carefully to avoid personal injury and

equipment damage. Some special parts can only be maintained by professional

technicians.

1.2 EGC Water Analyzer Unit (WAU) is an integrated water quality monitoring

system produced by German company TriOS, which is specially designed for

online water quality monitoring of ship flue gas desulfurization system and is in

accordance with resolution MEPC.259 (68).

1.3 To keep the WAU in normal working condition, users need to clean, maintain

and calibrate/verification the sensors, clean and maintain the flow cells

regularly.

1.4 When the device is in use, the power input should be stable, the use

environment should meet the installation requirements and the grounding


should be good less than 5Ω.

1.5 When the device is stopped for a long time, please ensure that the pH sensor is

flooded with water to avoid sensor failure due to longterm dry conditions.

1.6 Sensor storage: It should be placed in a dry and dark environment, ambient
temperature 5 ℃ ~ 45 ℃ and prevent heavy objects from being squeezed.

Notice: The measuring part of the pH sensor must be filled with a saturated

potassium chloride solution, which needs to be checked regularly to ensure the

content of the preservation solution.

1.7 Replace O-rings on each sensor regularly to prevent leaks.

32 after-saleservice@zeme-china.com
EGCS maintenance manual 浙江浙能迈领环境科技有限公司

2 Sensor Installation
Make certain that every sensor is assigned to a COM port on the TriBox3.

The assignment is

 COM Port 1: enviroFlu

 COM Port 2: TTurb

 COM Port 3: TpH-D

 COM Port 4: Flow rate sensor (this is already connected by the

manufacturer)

and is explained in detail in the following chapters.

2.1 enviroFlu

Follow the steps of the instructions on the following pages to install the enviroFlu in

the FlowCell.

1. Remove the pressure ring of the FlowCell with the O-ring by removing the four

screws with a 4 mm Allen key.

after-saleservice@zeme-china.com 33
浙江浙能迈领环境科技有限公司 EGCS maintenance manual

2. Remove the clamp bracket with a 6mm Allen key. To attach the cables of the

sensors, you can use the plastic brackets on the front and back panels.

3. First slide the pressure ring onto the enviroFlu and then the O-ring. Next, insert

the enviroFlu into the FlowCell, as shown in the figure below. The device is then

inserted into the FlowCell up to the groove of the bracket. Make sure that the

sealing ring is in the correct position and is undamaged. The correct O-rings

(sealing rings) can be obtained from TriOS.

4. When the enviroFlu is positioned correctly, reattach the clamp bracket and

tighten the screws.

34 after-saleservice@zeme-china.com
EGCS maintenance manual 浙江浙能迈领环境科技有限公司

5. The sensor is connected to COM Port 1 of the TriBox3.

2.2 TTurb

Follow the steps below to install the TTurb turbidity sensor into the FlowCell.

1. Remove the pressure ring from the Flow Cell. It can easily be loosened by hand.

2. First push the O-ring (which is attached to the Flow Cell in the bag) onto the

TTurb. Next insert the TTurb into the Flow Cell.

3. Position the TTurb along the groove, then move the pressure ring over the cable,

from the plug to the sensor, and attach it to the Flow Cell.

4. When the TTurb has been positioned correctly, tighten the pressure ring by

hand (without using a tool).

5. The sensor is connected to COM port 2 of the TriBox3.

2.3 TpH-D

Follow the steps below to install the TpH-D pH sensor in the FlowCell. The TpH-D

after-saleservice@zeme-china.com 35
浙江浙能迈领环境科技有限公司 EGCS maintenance manual

should only be installed when water will very soon be directed into the FlowCell. If

this is not the case, you should leave the sensor in the delivery container to keep it

moist.For the function test, it is sufcient to connect the sensor only to COM Port 3

at frst. After the function test, the sensor can be installed in the FlowCell according

to these instructions.

1. Remove the pressure ring from the FlowCell. It can easily be loosened by hand.

2. First push the O-ring (which is attached to the FlowCell in the bag) onto the

TpH-D. Next insert the TpH-D into the FlowCell.

3. As soon as the TpH-D is attached to the FlowCell, move the pressure ring over

the cable, from the plug to the sensor, and attach it to the FlowCell.

4. When the TpH-D has been positioned correctly, tighten the pressure ring by

hand (without using a tool).

5. The sensor is connected to COM Port 3 of the TriBox3.

36 after-saleservice@zeme-china.com
EGCS maintenance manual 浙江浙能迈领环境科技有限公司

3 Calibration
Calibration by the user is only intended by the manufacturer to be carried out on

the TpH-D pH sensor. The enviroFlu and the TTurb should be cleaned, maintained

and validated regularly.

For validation or calibration, the sensors must frst be removed and cleaned. Please

refer to Chapter 4 Cleaning and Upkeep. We recommend carrying out maintenance

and validation of the sensors at the following time intervals.

Name Specification Replacement Remarks


O-ring for PAH sensor 68×5 NBR Max. 6 months
O-ring for Tturb sensor 36×2.5 NBR Max. 6 months
O-ring for pH sensor 28×2.5 NBR Max. 6 months

3.1 Guided Validation

Before the sensors are validated, the TriBox3 must be set to service mode so that

the measured values are held at the outputs and there are no malfunctions or

incorrect values transferred. To start service mode, select "Sensor" at the top right

of the main menu and then select "Sensor check" (bottom left).

after-saleservice@zeme-china.com 37
浙江浙能迈领环境科技有限公司 EGCS maintenance manual

Service mode is started with the "Service mode" button (top left). The background

colour of the button changes from blue to red, and the buttons for the sensors

become activated. As soon as the service mode is activated, the fve LEDs on the

front of the TriBox3 flash.

38 after-saleservice@zeme-china.com
EGCS maintenance manual 浙江浙能迈领环境科技有限公司

1. When EGCS system is shut down, cut off the water flow (close ball valve taps on

the underside of the cabinet).

2. Stop water feed from the user.

3. Let water drain from the FlowCells.

3.2 Validation of the enviroFlu

1. Inject enough pure water or distilled water into the clean PAH FlowCell.( About

0.5L)

2. The PAH sensor is installed in the FlowCell correctly to obtain the measured

value, which is in the range of 0 ~ 20ppb, so it can be judged that it works

normally.

after-saleservice@zeme-china.com 39
浙江浙能迈领环境科技有限公司 EGCS maintenance manual

3. Fully secure the sensor and end the validation for PAH sensor.

3.3 Validation of the TTurb

For the TTurb, a one-point validation is used for the slope.

Start the validation of the TTurb by clicking on "Turbidity Sensor".

1. Release the pressure ring of the FlowCell (1).

2. Remove the TTurb (2) from the FlowCell.

3. Remove the sealing ring (3) of the TTurb (2), store in a safe place.

40 after-saleservice@zeme-china.com
EGCS maintenance manual 浙江浙能迈领环境科技有限公司

4. As described in Chapter 4, rinse the sensor with clean water (not seawater) and

clean the measuring window with a soft paper towel and acetone or spirits.

5. Add the turbidity standard solution (400FNU) to the container, start the

validation.

6. Enter the value of your measuring solution ("Edit", enter value, "Ok") and click

"Continue" to go on.

7. After the test of the measured value stability, "Sample" is activated. The

validation point is recorded with "Sample" as the average of 16 measurements.

This step can be repeated by clicking on "Sample" again. Click "Continue" to

after-saleservice@zeme-china.com 41
浙江浙能迈领环境科技有限公司 EGCS maintenance manual

confirm the result.

8. The value calculated for the scaling is now displayed and is then confirmed by

clicking "Continue".

9. You will be informed as to whether the calculated scaling is OK. By clicking

"Continue", you confrm that the sensor is still functioning properly with the

factory default settings and you keep the default settings.

42 after-saleservice@zeme-china.com
EGCS maintenance manual 浙江浙能迈领环境科技有限公司

10. Click "Finish" to fnish the validation of the TTurb.

3.4 Calibration of the TpH-D

1. Select "pH Sensor" to start the calibration.

after-saleservice@zeme-china.com 43
浙江浙能迈领环境科技有限公司 EGCS maintenance manual

2. An installed wizard guides you through the calibration process step-by-step. At

the top edge of the display, you can always see which step is currently being

carried out. After you have read the instructions on the frst page, click

"Continue" to move on.

3. The two buffers(pH7 and pH4) are injected into the corresponding labeled

solution bottle,each solution bottle was filled with 180ml buffer.

4. On the next page, you will see the instruction again that the sensor must be

cleaned before you continue. To clean the sensor, rinse it with water and then

place it in the pH 7 buffer solution.

44 after-saleservice@zeme-china.com
EGCS maintenance manual 浙江浙能迈领环境科技有限公司

5. Allow stabilization for at least fve minutes. Use "Edit" to enter the pH value that

matches the temperature of the buffer solution and click "OK" to confrm. Then

click "Continue" to go on.

6. After the test of the measured value stability, "Sample" is activated. The pH

value is recorded with "Sample" as the average of 16 measurements. This step

can be repeated by clicking on "Sample" again. The "Continue" button is

activated as soon as the measurement is finished.

after-saleservice@zeme-china.com 45
浙江浙能迈领环境科技有限公司 EGCS maintenance manual

7. Click "Continue" to confirm the result.

8. Click "Finish" to confirm finalization of the calibration.

9. pH 4 calibration for pH sensor using the same operation as above. Finally click

"Finish" to confirm finalization of the calibration.

46 after-saleservice@zeme-china.com
EGCS maintenance manual 浙江浙能迈领环境科技有限公司

10. Remove the pH sensor from the buffer solution and rinse it with distilled /

deionized water. When the calibration is finished, you should reinstall the TpH-D.

Remove the mounting bracket from the sensor plug. Carefully reinsert the

sensor back into the FlowCell and tighten the pressure ring by hand.

3.5 Stop service mode and resume operation

1. Close the drain of the TTurb FlowCell.

2. Activate water inflow.

3. Check both FlowCells for leaks.

4. Deactivate "Service mode" (The colour of the button changes from red to blue;

the buttons for the sensors become inactive; the TriBox3 LEDs no longer light

up).

after-saleservice@zeme-china.com 47
浙江浙能迈领环境科技有限公司 EGCS maintenance manual

5. In the menu, click on "Display" to check if all the sensors are functioning

properly again. Wait five minutes to check if all the sensors are recognized. Take

a look at the measured values. If everything is functioning properly, you can

finally finish the maintenance process.

4 Cleaning and upkeep


4.1 Preparation

1. Before cleaning and upkeep, the TriBox3 must be set to service mode so that the

measured values are held at the outputs and there are no malfunctions or

incorrect values transferred.

2. The following tools may be used:

a. Dishcloth: used for the cleaning of flow cell, sensor housing and water

stains.

b. Soft cloth or sponge: used for wiping stains if the test window of sensor is

too dirty. To prevent scratches on the test window glass that can affect the

sensor measurement accuracy, please be very careful.

c. Tie band: 2 tie bands, 3×100mm, used for fixing turbidity flow cell and pH

flow cell after cleaning.

48 after-saleservice@zeme-china.com
EGCS maintenance manual 浙江浙能迈领环境科技有限公司

d. Brush: used for cleaning stains on the inner wall of PAH flow cell.

e. Allen wrench: used for removing flow cells, 6mm and 4mm will be used.

f. Scissors: used for cutting the tie bands.

g. Container: used for holding clear water for flushing sensors and flow cells.

3. Power off the water quality monitoring system.

4. Close the inlet and outlet valves on the pipeline connected to the water quality

monitoring system.

after-saleservice@zeme-china.com 49
浙江浙能迈领环境科技有限公司 EGCS maintenance manual

5. Lay the dishcloth on the bottom of the cabinet to absorb the leaking water

during the disassembly of the flow cell, then remove the inlet and outlet hoses

of each flow cell.

4.2 Cleaning and upkeep for PAH sensor

1. Remove the cable connector of the PAH sensor from the controller.

2. Use a 6mm allen wrench to loosen the clip holding the PAH sensor.

50 after-saleservice@zeme-china.com
EGCS maintenance manual 浙江浙能迈领环境科技有限公司

3. Use a 4mm allen wrench to loosen the cover on the top of the PAH flow cell,

remove the PAH sensor and put it on a safe place.

after-saleservice@zeme-china.com 51
浙江浙能迈领环境科技有限公司 EGCS maintenance manual

52 after-saleservice@zeme-china.com
EGCS maintenance manual 浙江浙能迈领环境科技有限公司

4. Use a 4mm allen wrench to remove the PAH flow cell from the mounting plate

and place it on a safe place.

5. Use a brush to clean the PAH flow cell, then rinse the PAH flow cell with clean

water for 2 to 4 times depending on the pollution level.

after-saleservice@zeme-china.com 53
浙江浙能迈领环境科技有限公司 EGCS maintenance manual

6. When cleaning the measurement window of PAH sensors, we need to be very

careful to prevent scratching the window glass and affecting the measurement

accuracy. Normally, we do not clean the measurement window but the sensor

housing. But if the measuring window is very dirty, we must clean it: wet the

soft cloth or sponge with water, then carefully wipe the measuring window, and

finally use water to wash the measuring window to finish cleaning.

54 after-saleservice@zeme-china.com
EGCS maintenance manual 浙江浙能迈领环境科技有限公司

7. Reinstall the cleaned PAH flow cell.

8. Reinstall the cleaned PAH sensor.

after-saleservice@zeme-china.com 55
浙江浙能迈领环境科技有限公司 EGCS maintenance manual

4.3 Cleaning and upkeep for pH and Turbidity sensors

1. Remove the cable connector of the pH sensor from the controller.

2. Turn the thread on the upper part of the pH flow cell, remove the lock nut, take

out the pH sensor and put it in a safe place.

56 after-saleservice@zeme-china.com
EGCS maintenance manual 浙江浙能迈领环境科技有限公司

3. Remove the cable connector of the turbidity sensor from the controller.

4. Turn the thread on the upper part of the pH flow cell, remove the lock nut, take

out the pH sensor and put it in a safe place.

5. Cut the tie bands of the fixed pins at the back of the pH and turbidity flow cell

with scissors, draw out the fixed pins, remove the whole flow cell assembly and

put it in a safe place.

after-saleservice@zeme-china.com 57
浙江浙能迈领环境科技有限公司 EGCS maintenance manual

6. Use a 6mm allen wrench to separate the pH and turbidity flow cell components

for thorough cleaning. Clean the separated flow cell parts with a brush and rinse

with clean water for 2-4 times depending on the pollution level.

7. When cleaning the measurement window of turbidity sensors, we need to be

very careful to prevent scratching the window glass and affecting the

measurement accuracy. Normally, we do not clean the measurement window

but the sensor housing. But if the measuring window is very dirty, we must clean

it: wet the soft cloth or sponge with water, then carefully wipe the measuring

window, and finally use water to wash the measuring window to finish cleaning.

58 after-saleservice@zeme-china.com
EGCS maintenance manual 浙江浙能迈领环境科技有限公司

8. We only need to clean the housing of pH sensor, it is strictly forbidden to

perform any cleaning operation on the measurement part.

9. Assemble the cleaned pH and turbidity flowcell into a unit and reinstall it.

after-saleservice@zeme-china.com 59
浙江浙能迈领环境科技有限公司 EGCS maintenance manual

10. Fix the two fixed pins of the flowcell assembly with tie bands.

11. Reinstall the cleaned pH and turbidity sensor.

60 after-saleservice@zeme-china.com
EGCS maintenance manual 浙江浙能迈领环境科技有限公司

after-saleservice@zeme-china.com 61
浙江浙能迈领环境科技有限公司 EGCS maintenance manual

4.4 Restoration

1. Restore the connection lines of each flow cell.

2. Restore the inlet and outlet valves on the pipeline connected to the water

quality monitoring system.

3. Power on the water quality monitoring system and wait for 3 minutes to confirm

whether the system is in normal operation. If so, the cleaning and maintenance

work is finished.

62 after-saleservice@zeme-china.com
EGCS maintenance manual 浙江浙能迈领环境科技有限公司

5 Customer Service
If you have problems with the EGC Water Analyzer, please contact our customer

service.

Guohuan Lvyuan customer service

Technical support contact:

qualitydepartment01@cqghly.com

Telephone: +86-23-6231 8206

TriOS customer service

Technical support contact:

support@trios.de

Telephone: +49 (0) 4402 69670 - 0

Fax: +49 (0) 4402 69670 – 20

For quick help, please send us the device or sensor ID number, consisting of letters

and numbers by e-mail.

Add the turbidity standard solution (400FNU) to the container, start the validation.

after-saleservice@zeme-china.com 63
浙江浙能迈领环境科技有限公司 EGCS maintenance manual

11. Enter the value of your measuring solution ("Edit", enter value, "Ok") and click

"Continue" to go on.

12. After the test of the measured value stability, "Sample" is activated. The

validation point is recorded with "Sample" as the average of 16 measurements.

This step can be repeated by clicking on "Sample" again. Click "Continue" to

confirm the result.

64 after-saleservice@zeme-china.com
EGCS maintenance manual 浙江浙能迈领环境科技有限公司

13. The value calculated for the scaling is now displayed and is then confirmed by

clicking "Continue".

14. You will be informed as to whether the calculated scaling is OK. By clicking

"Continue", you confrm that the sensor is still functioning properly with the

factory default settings and you keep the default settings.

after-saleservice@zeme-china.com 65
浙江浙能迈领环境科技有限公司 EGCS maintenance manual

15. Click "Finish" to fnish the validation of the TTurb.

5.1 Calibration of the TpH-D

11. Select "pH Sensor" to start the calibration.

66 after-saleservice@zeme-china.com
EGCS maintenance manual 浙江浙能迈领环境科技有限公司

12. An installed wizard guides you through the calibration process step-by-step. At

the top edge of the display, you can always see which step is currently being

carried out. After you have read the instructions on the frst page, click

"Continue" to move on.

13. The two buffers(pH7 and pH4) are injected into the corresponding labeled

solution bottle,each solution bottle was filled with 180ml buffer.

14. On the next page, you will see the instruction again that the sensor must be

cleaned before you continue. To clean the sensor, rinse it with water and then

place it in the pH 7 buffer solution.

after-saleservice@zeme-china.com 67
浙江浙能迈领环境科技有限公司 EGCS maintenance manual

15. Allow stabilization for at least fve minutes. Use "Edit" to enter the pH value that

matches the temperature of the buffer solution and click "OK" to confrm. Then

click "Continue" to go on.

16. After the test of the measured value stability, "Sample" is activated. The pH

value is recorded with "Sample" as the average of 16 measurements. This step

can be repeated by clicking on "Sample" again. The "Continue" button is

activated as soon as the measurement is finished.

68 after-saleservice@zeme-china.com
EGCS maintenance manual 浙江浙能迈领环境科技有限公司

17. Click "Continue" to confirm the result.

18. Click "Finish" to confirm finalization of the calibration.

19. pH 4 calibration for pH sensor using the same operation as above. Finally click

"Finish" to confirm finalization of the calibration.

20. Remove the pH sensor from the buffer solution and rinse it with distilled /

deionized water. When the calibration is finished, you should reinstall the TpH-D.

Remove the mounting bracket from the sensor plug. Carefully reinsert the

sensor back into the FlowCell and tighten the pressure ring by hand.

after-saleservice@zeme-china.com 69
浙江浙能迈领环境科技有限公司 EGCS maintenance manual

5.2 Stop service mode and resume operation

6. Close the drain of the TTurb FlowCell.

7. Activate water inflow.

8. Check both FlowCells for leaks.

9. Deactivate "Service mode" (The colour of the button changes from red to blue;

the buttons for the sensors become inactive; the TriBox3 LEDs no longer light

up).

10. In the menu, click on "Display" to check if all the sensors are functioning

properly again. Wait five minutes to check if all the sensors are recognized. Take

a look at the measured values. If everything is functioning properly, you can

finally finish the maintenance process.

6 Cleaning and upkeep


6.1 Preparation

6. Before cleaning and upkeep, the TriBox3 must be set to service mode so that the

measured values are held at the outputs and there are no malfunctions or

incorrect values transferred.

7. The following tools may be used:

70 after-saleservice@zeme-china.com
EGCS maintenance manual 浙江浙能迈领环境科技有限公司

h. Dishcloth: used for the cleaning of flow cell, sensor housing and water

stains.

i. Soft cloth or sponge: used for wiping stains if the test window of sensor is

too dirty. To prevent scratches on the test window glass that can affect the

sensor measurement accuracy, please be very careful.

j. Tie band: 2 tie bands, 3×100mm, used for fixing turbidity flow cell and pH

flow cell after cleaning.

k. Brush: used for cleaning stains on the inner wall of PAH flow cell.

l. Allen wrench: used for removing flow cells, 6mm and 4mm will be used.

m. Scissors: used for cutting the tie bands.

n. Container: used for holding clear water for flushing sensors and flow cells.

8. Power off the water quality monitoring system.

after-saleservice@zeme-china.com 71
浙江浙能迈领环境科技有限公司 EGCS maintenance manual

9. Close the inlet and outlet valves on the pipeline connected to the water quality

monitoring system.

10. Lay the dishcloth on the bottom of the cabinet to absorb the leaking water

during the disassembly of the flow cell, then remove the inlet and outlet hoses

of each flow cell.

6.2 Cleaning and upkeep for PAH sensor

72 after-saleservice@zeme-china.com
EGCS maintenance manual 浙江浙能迈领环境科技有限公司

9. Remove the cable connector of the PAH sensor from the controller.

10. Use a 6mm allen wrench to loosen the clip holding the PAH sensor.

after-saleservice@zeme-china.com 73
浙江浙能迈领环境科技有限公司 EGCS maintenance manual

11. Use a 4mm allen wrench to loosen the cover on the top of the PAH flow cell,

remove the PAH sensor and put it on a safe place.

74 after-saleservice@zeme-china.com
EGCS maintenance manual 浙江浙能迈领环境科技有限公司

12. Use a 4mm allen wrench to remove the PAH flow cell from the mounting plate

and place it on a safe place.

13. Use a brush to clean the PAH flow cell, then rinse the PAH flow cell with clean

water for 2 to 4 times depending on the pollution level.

after-saleservice@zeme-china.com 75
浙江浙能迈领环境科技有限公司 EGCS maintenance manual

14. When cleaning the measurement window of PAH sensors, we need to be very

careful to prevent scratching the window glass and affecting the measurement

accuracy. Normally, we do not clean the measurement window but the sensor

housing. But if the measuring window is very dirty, we must clean it: wet the

soft cloth or sponge with water, then carefully wipe the measuring window, and

finally use water to wash the measuring window to finish cleaning.

76 after-saleservice@zeme-china.com
EGCS maintenance manual 浙江浙能迈领环境科技有限公司

15. Reinstall the cleaned PAH flow cell.

16. Reinstall the cleaned PAH sensor.

after-saleservice@zeme-china.com 77
浙江浙能迈领环境科技有限公司 EGCS maintenance manual

6.3 Cleaning and upkeep for pH and Turbidity sensors

12. Remove the cable connector of the pH sensor from the controller.

13. Turn the thread on the upper part of the pH flow cell, remove the lock nut, take

out the pH sensor and put it in a safe place.

78 after-saleservice@zeme-china.com
EGCS maintenance manual 浙江浙能迈领环境科技有限公司

14. Remove the cable connector of the turbidity sensor from the controller.

15. Turn the thread on the upper part of the pH flow cell, remove the lock nut, take

out the pH sensor and put it in a safe place.

16. Cut the tie bands of the fixed pins at the back of the pH and turbidity flow cell

with scissors, draw out the fixed pins, remove the whole flow cell assembly and

put it in a safe place.

after-saleservice@zeme-china.com 79
浙江浙能迈领环境科技有限公司 EGCS maintenance manual

17. Use a 6mm allen wrench to separate the pH and turbidity flow cell components

for thorough cleaning. Clean the separated flow cell parts with a brush and rinse

with clean water for 2-4 times depending on the pollution level.

18. When cleaning the measurement window of turbidity sensors, we need to be

very careful to prevent scratching the window glass and affecting the

measurement accuracy. Normally, we do not clean the measurement window

but the sensor housing. But if the measuring window is very dirty, we must clean

it: wet the soft cloth or sponge with water, then carefully wipe the measuring

window, and finally use water to wash the measuring window to finish cleaning.

80 after-saleservice@zeme-china.com
EGCS maintenance manual 浙江浙能迈领环境科技有限公司

19. We only need to clean the housing of pH sensor, it is strictly forbidden to

perform any cleaning operation on the measurement part.

20. Assemble the cleaned pH and turbidity flowcell into a unit and reinstall it.

after-saleservice@zeme-china.com 81
浙江浙能迈领环境科技有限公司 EGCS maintenance manual

21. Fix the two fixed pins of the flowcell assembly with tie bands.

22. Reinstall the cleaned pH and turbidity sensor.

82 after-saleservice@zeme-china.com
EGCS maintenance manual 浙江浙能迈领环境科技有限公司

after-saleservice@zeme-china.com 83
浙江浙能迈领环境科技有限公司 EGCS maintenance manual

6.4 Restoration

4. Restore the connection lines of each flow cell.

5. Restore the inlet and outlet valves on the pipeline connected to the water

quality monitoring system.

6. Power on the water quality monitoring system and wait for 3 minutes to confirm

whether the system is in normal operation. If so, the cleaning and maintenance

work is finished.

84 after-saleservice@zeme-china.com
EGCS maintenance manual 浙江浙能迈领环境科技有限公司

第四部分 洗涤塔的一般维护
Equipment Maintenance spares reqiresd for
S.no. Work description
name interva maintenance
Scrubber
洗涤塔
入口保温层
every 12 修复保温层
1 Inlet
months Repair the insulation
insulation
管口连接螺
栓 紧固螺栓
every 3
2 Every Tighten the bolt
months
nozzle’s
bolts
塔支座与弹
性支承连接
螺栓
The
connect every 3 紧固螺栓
3
between months Tighten the bolt
Lug
support
and elastic
support
塔外表面腐 情况不严重的,局部补焊并进
蚀、磨损情 行局部打磨、酸洗;情况严重
况 的联系迈领制定修补方案。
Corrosion If the situation is not serious,
every 12
4 and wear partial repair welding shall be
months
condition of carried out, then grinding and
external pickling; If the situation is
surface of serious, contact with the
scrubber ZEME to make a repair plan

after-saleservice@zeme-china.com 85
浙江浙能迈领环境科技有限公司 EGCS maintenance manual

1)视破损情况进行局部修复,
材料使用 1mm 厚 S32205
1) Local repair shall be
carried out according to the
除雾器 every 6
5 damage, and the material
Demister months
shall be 1mm thick S32205
2)人工清洗除雾器堵塞区域
2) Manually clean the
blocked area of the demister
1)紧固喷嘴 洗涤塔主喷淋喷嘴
1)Tighten the nozzle with spray layers of
nozzle every 3 wrench. scruber 1-1/4'
6
喷嘴 months 2)拆下喷嘴清洗后重新安装 (quantity:1)spray
2)Remove the nozzle clearly layers of scruber 1 '
and reinstall it after cleaning. (quantity:2)
1)紧固螺栓
1)Tighten the bolt
2)视破损情况修补反应盘,材
料使用 3mm 厚 S32205,需整
Unform 块更换的请联系迈领
every 3
7 Flow Plate 2) Repair the uniform flow
months
均流反应盘 plate according to the
damage, the material is 3mm
thick S32205. Please contact
the ZEME if you need to
replace the whole block.
塔内腐蚀情 局部焊缝处进行补焊,焊接使
况 用 S32205
every 12
8 Corrosion partial repair welding shall be
months
condition in carried out, S32205 for
scrubber welding

86 after-saleservice@zeme-china.com
EGCS maintenance manual 浙江浙能迈领环境科技有限公司

第五部分 阀门的一般维护
General maintenance of valves
EGCS 不管开式或者混合式,都会使用一些电动阀门来确保设备
的正常运行,我们的系统主要使用的阀门一般包括 QT 型智能一
体化机型、非侵入式智能机型阀门电动装置,ETM 型智能一体化
机型
EGCS, whether open or hybrid, will use some electric valves to
ensure the normal operation of the equipment. The main valves
used in our system generally include QT intelligent integrated model,
non-invasive intelligent valve electric device and ETM intelligent
integrated model
5.QT 型执行机构 QT actuator

外观
Appearance

5.1 行程限位开关的调整
★电动前的注意事项:
电装首次运行时,必须确认电机的转动方向是否正确,若不正确可能对电装造成损坏(即必
须保证电机电源相序正确)。
(1)先转动手轮,手动将阀门运行至“开--关”中间位置,然后进行开或关的操作,以检查阀门
电动时的运行方向是否正确。
----输出轴顺时针转动(面向开度窗):阀门关闭。
----输出轴逆时针转动(面向开第窗):阀门打开。
(2)若阀门转动方向与上述的正确方向相反,应立即停止操作,并应再次检查接线(需改变电
机与电源相序的连接)。
★Adj ustment of stroke limit switch
tentioAtn before actuating: When electric actuator is operated for the first time, you must verify the
correctness of motor rotation direction, i.e. correct phase-sequence connection of motor power supply
must be ensured; otherwise, the actuator may be damaged.
1 First, turn the hand wheel to run the valve to the middle position between “Open” and “Close”, and
then conduct “open” and “close” operation to check whether the running direction is correct when
actuating.
-------Output shaft turns clockwise (facing openness window): the valve is closed.
--------Output shaft turns counterclockwise (facing openness window): the valve is opened.
2 If the valve turns in the direction opposite to the above correct direction, operation should be
immediately stopped, and wiring should be checked again. (Phase-sequence connection of the motor to
the power supply should be changed.)

5.2 “关”向限位开关的设定
以上准备就绪后将进行如下调整:
(1) 拉动手—电动切换手柄至手动位置后,顺时针转动手轮,使阀门至全关位置。
(2) 用“L”扳手,松动下部凸轮上的螺钉(关方向的限位开关)见下图。

after-saleservice@zeme-china.com 87
浙江浙能迈领环境科技有限公司 EGCS maintenance manual

(3) 调整凸轮,使之与下部的微动开关接触(刚好听到卡哒声),然后紧固螺钉。
(4) 接通电源,按下“开”向按钮,反方向运行某个角度,然后再向“关”方向运行,以检查阀门
“关”方向限位是否准确。
重复几次达到要求为止。
5.2 Setting of “Close” direction limit switch
After the above preparation is completed, perform the adjustment as follows:
1 Pull the manual-electric switching handle to “Manual” position, and then turn the hand wheel
clockwise to set the valve to the fully closed position.
2 Loose the screw on the cam at the bottom with “L” spanner as shown in the diagram below (“Close”
direction limit switch)
3 Adjust the cam to make it contact with the lower micro switch, when hear a click, fasten the screw.
4 Turn on the power, press the pushbutton for “open” direction. After the valve has run for an angle in
reverse direction, let it run in “close” direction, so as to check if the valve has an exact limit in “close”
direction. Repeat this step several times so that relevant requirement is met.

5.3 “开”向限位开关的设定
(1) 拉动手—电动切换手柄至手动位置后,逆时针转动手轮,使阀门至全开位置。
(2) 用“L”扳手,松动上部凸轮上的螺钉(开方向限位开关)见下图。
(3) 调整凸轮,使之与上部的微动开关接触(刚好听到卡哒声),然后紧固螺钉。
(4) 接同电源后,按下“关”向按钮,反方向运行即向“开”方向运行,以检查阀门“开”方向限位
是否准确。重复几次达到要求为止。
(5) 阀门的开、关位置可经过数次调整以达到与阀门的开、关位置一致。

5.3 Setting of “Open” direction limit switch


1 Pull the manual-electric switching handle to “Manual” position, and then turn the hand wheel
counterclockwise to set the valve to the fully opened position.
2 Loose the screw on the cam at the top with “L” spanner as shown in the diagram below (“Open”
direction limit switch).
3 Adjust the cam to make it contact with the upper micro switch, when hear a click, fasten the screw.
4 Turn on the power, press the pushbutton for “close” direction. After the valve has run for an angle in
reverse direction, let it run in “open” direction, so as to check if the valve has an exact limit in “open”
direction. Repeat this step several times so that relevant requirement is met.
The open and close of the valve are adjusted for several times so that its open or close position is fully
accorded with.

注:序号 1:上部凸轮----用于开方向限位的凸轮,
The upper cam --- for position limit on the open direction.
序号 2:下部凸轮----用于关方向限位的凸轮。
the lower cam --- for position limit on the close direction

5.4 机械限位螺栓
(1) 出厂时,装置上的两机械限位螺钉已调好并紧固,无特殊需要,用户不须松动。
(2) 如遇必须调整限位螺钉时,应首先确定该螺钉所限制的阀门位置。当阀门右旋为关时,右

88 after-saleservice@zeme-china.com
EGCS maintenance manual 浙江浙能迈领环境科技有限公司

侧为关限位螺钉,左侧为开限位螺钉(当箱罩开度窗向上,面对限位螺钉调整端面) 。
(3) 当调好阀门极限位置(或所需位置)时,先向内旋入限位螺钉至与扇形蜗轮端面相接触,
而后再退回 0.5~1 圈(使之成为行程限位或过转矩的安全保护)。最后将限位螺钉外端
的防松螺母可靠拧紧,至此限位调整完毕。
5.4 Mechanical stop screw
1 When the product is delivered, the two mechanical stop screws on the device have been adjusted and
fastened, which should not be loosened without special need.
2 If adjustment of the stop screws cannot be avoided, you should firstly determine the position of the
valve where the valve will be stopped by the screw. If the valve is closed by turning rightwards, the
close-direction stop screw is on the right side and the open-direction stop screw on the left side (when
the openness window on the case shield is upward, face the stop screw and adjust the end face).
3 When an end position (or required position) of the valve is set, firstly, screw in the stop screw to
make it contact with the end face of the segment worm gear, then turn back by 0.5-1 turn (to form a
stroke limit or over-torque protection for safety), finally, fasten the loosened nut located on external
end of the stop screw, thus adjustment of position limit has been finished.
5.5 转矩开关
正常情况下,不必对转矩开关重新设置或调整,因为在产品发货前已在工厂进行了设置,
以达到电装的额定转矩。
若遇必须调整转矩开关时,请与生产厂联系。
5.5 Torque switch
Normally, you need not to reset or adjust the torque switch because the product has been set
before it leaves factory in order to guarantee the rated torque of the electric actuator.
If torque switch has to be adjusted, please contact the manufacturer.

警告:转矩开关的设置,须使用特殊的精密仪器,以保护电装及阀体。必须重新设置或调整转
矩时,若事先不与生产厂家联系,其质量将不会得到保证。
Warning: When setting torque switch, special precision instrument must be used in order to
protect both the actuator and valve. In case re-setting or adjustment of torque cannot be avoided,
you must contactthe manufacturer in advance, failing to do so, the setting or adjustment quality
would not be guaranteed.

5.6 机械故障
△ 在拉动手—电动切换手柄后,用手轮驱动阀门,检查手—电动切换是否灵敏可靠。
△检查机械开度指示器的动作及指示是否正确。
△若手轮转不动,阀门堵塞,需拆下修理阀门。
△若手动运转正常,无干扰,而阀杆不动作,需检查阀杆接头连接是否可靠。
若阀门可用手轮驱动,再检查电气部分
5.6Mechanical troubles
△ ●Drive the valve using hand wheel after pulling manual-electric switching handle to check if
manual-electric switching is sensitive and reliable or not.
△ ●Check if action and indication of mechanical openness indication are correct.
△ ●If the hand wheel can’t be turned or valve is blocked, remove and repair the valve.
△ ●If the manual operation is normal and there is no interference, but the valve stem doesn’t function,
check if connection of adaptor of valve stem is secure.
△ ●If the valve can be driven using hand wheel, check electrical troubles next.

5.7 电气故障
先检查控制器动作,然后检查电装动作。
△检查主电源及控制电源、继电器、熔丝及所有指示灯、开关是否正常。
△ 若控制有问题,检查确定是否更换相关零件,若电气元件无问题,再检查电装。
△检查电机,如有问题可更换。
△若微动开关出现故障,则需要调整或更换。
△其它电气故障,可以通过更换相关元件解决。
5.7Electrical troubles
Check action of the controller, and then action of the actuator.
●Check if main power supply, control power, relay, fuse, all indication lamps and switches are

after-saleservice@zeme-china.com 89
浙江浙能迈领环境科技有限公司 EGCS maintenance manual

functional or not.
●If there is any trouble with control, check and determine if relevant parts should be replaced with new
ones. If no problem is found with electric components, check the actuator next.
●Check motor, and replace it with new one in case of any problem.
●If trouble occurs with micro switch, replace relevant components with new ones.

5.8 红外线遥控器(非侵入式智能型配件)
Infrared remote control (non-invasive intelligent accessories)

此阀门配备遥控器,可以使用遥控器操作并且做相关的校准
This valve is equipped with a remote control, which can be used for operation and related
calibration

Remote
Icon Function Comment
appearance

Switch Switch mode,or Back to main or last state

Confirm Save data.

Decrease Decrease value

Increase Increase value

Close Send a lose command

Open Send a open command

5.9 操作说明 Operating instruction


红色旋钮为方式钮:现场/停止/远方之间切换,或在设定状态实现参数的保存或确定(从停
位旋到现场)和退出(从停位旋到远方)。
The red knob is the mode button: switch between “Local”“ / Stop”“Remote”
/ . Save or determine
the parameters (from "Stop" to "Local") and exit (from "Stop" to "Remote") when setting the status.
黑色旋钮为操作钮:在现场模式进行开阀或关阀,或在设定状态进行加减设置。现场旋钮操
作时,短时间作用为现场点动模式,当操作钮有效作用时间超过 3 秒后进入现场保持模式,再次
操作黑色旋钮或将红色旋钮旋到停止,即停止动作。
The black knob is the operation button: open or close the valve in the “Local” mode. Add or
subtract settings in the setting state.
5.9.1 行程的设定(先确定电动执行器的转向和力矩接线正确)
Common Settings
关位标定 Full close
停止位置旋操作钮至关闭约 3 秒钟,等到 LCD 显示“全关 行程 设定”
时松开操作钮显示上次关位值,将方式钮旋到现场,当“全关”闪烁表示进入关
位标定(如图 4)。通过操作钮执行开关阀,调整到关位后将方式钮旋到停
止再旋回到现场进行关位确定。方式钮由停止旋至远方则直接退出行程标定。
Turn Mode-knob to the "stop" state. Keep Operation-knob turned "colse" for
3 seconds until the "Fully Close" "Travel" "Set" character starts to flash on the LCD and then release
Operation-knob. The data displayed at this time is the last closed full value. Rotate Mode-knob to the
"Local" state, and when the "Fully Close" character begins to flash, it indicates that it has entered Fully
Close Set (Figure 4). Operate the actuator to the fully closed position with the Mode-knob. Rotate
Mode-knob to the "Stop" state, and then rotate back to the "Local" state to determine "FullyClose". In
the process of setting, if Mode-knob is rotated from “Stop” to “Remote”, the stroke setting will be

90 after-saleservice@zeme-china.com
EGCS maintenance manual 浙江浙能迈领环境科技有限公司

directly exited.

开位标定 Fully Open


停止位置旋操作钮至打开约 3 秒钟,等到 LCD 显示“全开 行程 设定”
时松开操作钮显示上次开位值,将方式钮旋到现场,当“全开”闪烁表示进入
开位标定(如图 5)。通过操作钮执行开关阀,调整到开位后将方式钮旋到
停止再旋回现场进行开位确定。方式钮由停止旋至远方则直接退出行程标
定。
Turn Mode-knob to the "Stop" state. Operation-knob is turned "Open" for 3 seconds until the LCD
displays "Fully Open", "Travel", "Set", and Operation-knob is released. At this time, the last full open
data is displayed. Rotate Mode-knob to the "Local" state, and when the "Fully Open" character begins
to flash, it indicates that the full open setting is entered (see Figure 5). The actuator is moved to the
fully open position by the Operation-knob knob, then the Mode-knob is rotated to the "Stop" state, and
then rotated back to the "Local" state for the opening position determination. If you rotate Mode-knob
from "Stop" to "Remote", you will exit the trip setting directly.

5.9.2 常见问题处理方法
Problem and Solution
故障现象 处理方法
Problem Solution
通电显示屏和指示灯不显 电源未接入或电压过低 2、模块内连接线松动 4、电路坏
示 The power cable is not connected or the voltage is too low. 2.
LCD and LED are not The connection cable inside the module is loose. 4. The circuit is
displayed broken.
通电现场和远控均不动作 故障保护 2、电机坏或卡死 3、电路坏
Both Local and remote control 1, fault protection 2, the motor is broken or stuck 3, the circuit
do not operate is broken
现场工作正常远控不动作 远控信号给定异常 2、旋钮板坏或没在远方 3、电路坏
Local work normally remote 1. The remote control signal is given an abnormality. 2. The
control does not work knob board is bad or not in the distance. 3. The circuit is broken.
现场不动作但远控工作正 旋钮板坏或没在现场模式 2、操作钮未旋到位 3、电路坏
常 Local does not work but the 1. The knob board is broken or not in the field mode. 2. The
remote control works normally. operation button is not in place. 3. The circuit is broken.
能开不能关或能关不能开 力矩线接错或开路 2、电机坏或堵转或接线错 3、电路坏
Can OPen not close, or can close 1. The torque line is connected incorrectly or open circuit 2. The
can not be open motor is broken or blocked or the wiring is wrong. 3. The circuit is
broken.
无控制信号通电即动作 控制信号实际有或丢信动作 2、设为两线控制 3、电路坏
No control signal is 1. The control signal actually has or loses the signal action. 2.
energized Sets the two-wire control. 3. The circuit is broken.
中间位置能动作到限位不 力矩开关接线反 2、电机坏或接线开路 3、电路坏
动 The middle position can move 1. The torque switch is reversed. 2. The motor is broken or the
to the limit without moving wiring is open. 3. The circuit is broken.
动作方向反 电机接线反 2、阀位标定反 3、正反作用设反 4、信号反
Action direction 1. The motor wiring is reversed. 2. The valve position is
reversed. 3. The positive and negative effects are reversed. 4. The
signal is reversed.
无输出电流或时有时无 接线错或接触不良 2、电位器或编码器故障 3、电路坏
No output current or 1. Wrong wiring or poor contact 2. Potentiometer or encoder
sometimes no failure 3. Circuit is broken
反馈电流偏大偏小或不变 编码器故障或与传动齿轮啮合不好 2、标定错 3、电路坏
Feedback current is too small or 1. The encoder is faulty or not well meshed with the
constant transmission gear. 2. The calibration is wrong. 3. The circuit is
broken.
遥控器无反应 电池电压低或装错 2、遥控未对准显示窗口 3、遥控器坏
Remote control does not 1. The battery voltage is low or incorrectly installed. 2. The

after-saleservice@zeme-china.com 91
浙江浙能迈领环境科技有限公司 EGCS maintenance manual

respond remote control is not aligned with the display window. 3. The remote
control is broken.
显示故障且“输入缺相”闪 The input power supply is out of phase or the terminal is not
Display failure and "Input" tightened.
"Phase-Lack" flash 2. The circuit board is broken.
显示“故障”且“缺相”闪 输出缺相 2、电机坏 3、电机接未接好 4、电路板坏
Show "Erorr" and 1, the output phase loss 2, the motor is broken 3, the motor is
"Phase-Lack" flash not connected well 4, the circuit board is broken
显示“故障”且“过热”闪 电机过热或堵转或坏 2、电机温度传感器坏 3、电路坏
Show "Erorr" and 1. The motor is overheated or blocked or broken. 2. The motor
"Overheat" flash temperature sensor is broken. 3. The circuit is broken.
显示“故障”且“开过载”或 执行器选小了,启动力矩不足 2、力矩线未接好 3、行程设
“关过载”闪 定不正确 4、堵转或电机坏 5、电路坏
Show "Erorr" and "Open 1. The actuator is selected to be small, the starting torque is
Override" or "Close Override" insufficient. 2. The torque line is not connected. 3. The stroke setting
flash is incorrect. 4. The stall or the motor is broken. 5. The circuit is
broken.
动作正常但阀位显示不变 电位器或编码器坏 2、电位器或编码器线松动 3、电路坏
Normal operation but the valve 1. The potentiometer or encoder is broken. 2. The potentiometer
position is unchanged or encoder line is loose. 3. The circuit is broken.
阀到位后电装电机不停 行程设定错误 2、电位器或编码器异常 3、电路坏
After the valve is in place, 1. The stroke setting is wrong. 2. The potentiometer or encoder
the electric motor does not stop. is abnormal. 3. The circuit is broken.
显示丢信 4—20mA 信号源异常 2、接线错误或松动 3、电路坏
Show "signal lost" 1, 4-20mA signal source is abnormal 2, wiring error or loose 3,
the circuit is broken

11. EMT 智能电动执行器机构


EMT Intelligent Electric Actuator
一.显示面板介绍
本执行器 LCD 显示屏由主屏和副屏(用户选配)组成。在正常工作时只显示主屏。当系统供电电源被断
开时,系统通过内置的电池供电,此时只显示副屏。通过副屏可以查看当前阀门的开度信息。下图为主屏
及显示面板界面
The LCD display of this actuator is composed of the main screen and the secondary screen
(user optional). Only the main screen is displayed when working properly. When the system
power supply is disconnected, the system is powered by the built-in battery, and only the
secondary screen is displayed at this time. The current valve opening information can be viewed
through the secondary screen. The following image is the main screen and the Display panel
interface. 5
1

2
Stop 6
3
Torque:0
7

4 8
50.0%
Power phase missing 9

图中区域所指示的意义如下: 1
The meaning of the indicated area in the figure is as follows:

92 after-saleservice@zeme-china.com
EGCS maintenance manual 浙江浙能迈领环境科技有限公司

1 区: 当前控制信号指示 6 区: 设定器信号接收显示区
Zone Current control signal indication Zone Set Point signal Reception display area
1: 6:
2 区: 力矩值 7 区: 指示 LED 灯
Zone Torque value Zone Indication LED light
2: 7:
3 区: 红色 LED 灯 8 区: 当前阀位
Zone Red LED Lights Zone current valve position
3: 8:
4 区: 绿色 LED 灯 9 区: 红外遥控接收区
Zone Green LED Lights Zone Infrared remote-control receiving area
4: 9:
5 区: 电池电量显示 10 系统故障状态指示区
Zone Battery level display 区: System fault status indication area
5: Zone
10:

二、遥控器(设定器)介绍
Introduction of Remote control (Set Point)

上 Up 向上移动一条菜单或栏目 Move up a menu or column


下 Down 向下移动一条菜单或栏目 Move down a menu or column
确认 Confirm 确认参数或进入下级菜单 Confirm parameters or go to sub-menu
返回 Back 返回上级菜单或栏目(当有可清除故障时可手动清除故障)
Return to the parent menu or column (It can be cleared manually when
the fault can be cleared)
减 Decrease 减小/调整当前参数 Decrease/Adjust Current parameters
加 Add 增加/调整当前参数 Add/Adjust Current parameters
关 OFF 向执行器发送关阀命令 Send off valve command to actuator
开 ON 向执行器发送开阀命令 Send open valve command to actuator

三、操作介绍 Operation introduction


执行器电器罩有两个旋钮,分别是方式旋钮和操作旋钮。
就地电动操作执行器时,需要将方式旋钮旋到“就地”状态。通过操作旋钮(默认是点动式控制,可以
修改成保持式)或遥控器(保持式控制,不可修改)可以实现对执行器的开、关动作。当需要在远程控制执行
器时,请将执行器方式旋钮旋至“远程”状态。方式旋钮旋至“停止”状态时,将禁止所有电动操作(ESD
“超越停止”除外)。
The Actuator appliance Hood has two knobs, namely the mode knob and the operating knob. When the
actuator is electrically operated in place, the mode knob needs to be screwed to the "in place" state. Through the

after-saleservice@zeme-china.com 93
浙江浙能迈领环境科技有限公司 EGCS maintenance manual

Operation Knob (the default is the point-action control, which can be modified into a holding type) or remote
control (holding control, non-modifiable) can be implemented on the actuator opening and closing action. When
you need to remotely control the actuator, turn the actuator mode knob to the "remote" state.
When the mode knob is turned to "stop", all electric operations (except ESD "beyond Stop") will be banned.
四、系统设置
在“就地”或“停止”状态下长按确认键 3 秒可以进入系统菜单。进入菜单后任意界面 5 分钟内

*系统菜单* *01 基本设置* *1.2 开方向*


01.基本设置 01.关方向 开阀方式: 限
02.指示反馈 02.开方向 位
03.高级设置 03.力矩旁路 开 力 矩:
系统查询
无操作,则退出菜单。菜单中所有参数均可以在不输入密码进行查看。系统初级密码为 311,可以修改“01.
基本设置”和“02.指示反馈”中的数据参数。输入一次正确的密码后,如果没有退出系统菜单,修改
其他参数也不需要再次输入密码。以下将实例讲解如何进入设置并修改“开阀方式”。将执行器方式
旋钮旋到就地或停止状态,按确认键 3 秒进入系统菜单。按选中 01.基本设置 按确认键 进入。按
向下键 选中 02.开方向,按确认键 进入 1.2 开方向。再按确认键 进入修改开阀方式参数。
此时调出一个需要“输入密码”界面

*1.1 关方向* *1.1 关方向* *1.2 开方向*


请输入密 请输入密 开阀方式: 限

00 31 位
开 力 矩:
按加键 、减键 调整当前数字,按向上键 、向下键 选中当前输入的数字位。输入正确密码后,

按确认键 。此时跳转到修改开阀方式选项,通过 调整修改当前参数。此时若按返回键 则直

接返回,没有保存参数。若按确认键 ,标题栏会出现红色“已存”提示,然后再返回,表示参数已经

保存。
Press and hold the confirm key in the "in place" or "Stop" state for 3 seconds to enter the
system menu. After entering the menu, any interface will not operate within 5 minutes, then exit
the menu. All parameters in the menu can be viewed without entering a password. The system
primary password is 311, you can modify the data parameters in "01. Basic Settings" and "02.
Indicate feedback". After entering the correct password once, if you do not exit the system menu,
modify the other parameters and do not need to enter the password again.
Below is an example on how to do the settings.
To rotate the actuator mode knob to the in-place or stop state, press the confirm key for 3
seconds to enter the system menu. Press to select 01. Basic Settings press the Confirm key to
enter. Press the DOWN ARROW key to select 02. Turn on direction, press the Confirm key

* System Menu* *01 Basic Settings* *1.2 Turn on


direction*
01.Basic Settings 01.Turn Off direction
02.Instruction feedback 02.Turn on direction Mode: Limit
03.Advanced Settings 03.Torque Sideway Torque: 100%
to enter 1.2 Turn on direction. Then press the Confirm key to enter the modified open valve
mode parameter.
Then a screen is shown to “input password”.
Press add key , minus key to adjust the current number, press UP ARROW , DOWN arrow

94 after-saleservice@zeme-china.com
EGCS maintenance manual 浙江浙能迈领环境科技有限公司

to select the current input digits. After entering the correct password, press the Confirm key .
At this point jump to modify the open valve mode option, modify the current parameters by
adjusting . If you press the return key at this point, you return directly without saving the
parameters. If you press the Confirm key , the title bar will appear red "saved" prompt, and
then return, indicating that the parameter has been saved.

1 基本设置
1.1 关方向
关阀方向
设置关闭阀门时的输出旋转方向。使用手轮,手动操作执行器以确定阀门关闭方向。
初次设置行程限位时应先确保阀门输出方向正确,使用时须根据实际情况调整!
顺时针(默认)—执行器顺时针旋转关闭阀门。
逆时针 —执行器逆时针旋转关闭阀门。
关阀方式 *1.1 关方向*
限位(默认)—即行程。阀门朝关方向运行时,到达设定的关
限位位置后停止运行。 关阀方向: 顺时针
力矩 —阀门朝关方向运行时,到达设定关限位时不停,一
直运行到设定的关力矩值才停机。
关阀方式: 限位
关力矩 关 力 矩: 100%
执行器关阀力矩值可设定额定力矩的 40%~100%范围之间。
当力矩达到设定值阀门停止运行。若同一方向连续 3 次达到
关 限 位: 3000
设定值,则显示关力矩故障。
关限位
未选中前,显示的是保存的数据,当输入正确的密码选中数据时,显示的是当前阀门的绝对位置。在设置
关限位前,务必确保“关阀方向”正确。若要执行电动操作,请将方式旋钮旋至“就地”状态!
设置限位时,必须将执行器连接至阀门。用遥控器或旋钮关阀键将阀门移至全关位置,按确定键保存关限位
数据。 关限位和开限位之间的输出转数最小值为 2.5 圈(总圈数在“开限位”中可查看),否则不能正常运行。
1.2 开方向
开阀方式 *1.2 开方向*
限位(默认)—即行程。阀门朝开方向运行时,到达设定的开
限位位置后停止运行。
力矩 —阀门朝开方向运行时,到达设定的开限后不停,一
开阀方式: 限位
直运行到设定的开力矩值才停机。 开 力 矩: 100%
开力矩 开 限 位: 2000
执行器开阀力矩值可设定额定力矩的 40%~100%范围之间。
当力矩达到设定值阀门停止运行。若同一方向连续 3 次达到 圈数:1000
设定值,则显示开力矩故障。
开限位
若要执行电动操作,请将方式旋钮旋至“就地”状态!设置限位时,必须将执行器连接至阀门。用设定器或
旋钮开阀键将阀门移至全开位置,按确定键保存开限位数据。 关限位和开限位之间的输出转数最小值为
2.5 圈,否则不能正常运行。
圈数
指的是关限位和开限位数据的差值,此参数不可设置。设定的
圈数必须要大于 2 圈。 *1.3 力矩旁路*
1.3 力矩旁路
在设定的旁路行程范围内,执行器输出力矩允许达到额定力
开阀旁路: 禁用
矩的 150%,打开粘滞型的阀门。 开向行程: 0-95%
在设定的旁路行程外,执行器继续按照设定的力矩值保护。
开阀旁路 关阀旁路: 禁用
禁用(默认)—开方向旁路功能关闭 关向行程: 5-100%
启用 — 开方向旁路功能打开
开向行程
“开阀旁路”启用时,开向行程 0%-95%(默认)区间内,关力矩旁路生效。力矩旁路位置可设置为:0%~ N%(0
≤N≤95)。
关阀旁路

after-saleservice@zeme-china.com 95
浙江浙能迈领环境科技有限公司 EGCS maintenance manual

禁用(默认)—关方向旁路功能关闭
启用 — 关方向旁路功能打开
关旁行程
“关阀旁路”启用时,关向行程 5%-100%(默认)区间内,关力矩旁路生效。力矩旁路位置可设置为:N%~ 100%(5
≤N≤100)。

1.1 OFF
shutoff valve Direction
Sets the direction of output rotation when the valve is closed. Using the Handwheel, manually
operate the actuator to determine the valve
closing direction.
When setting the travel limit for the first time, it *01 Limit Switch Settings*
is supposed to ensure that the valve output
direction is correct, and the use must be adjusted 01.Turn Off direction
according to the actual situation! 02.Turn On direction
Clockwise(Default)— The actuator Clockwise
03.Torque sideway
rotates to close the valve.
Counterclockwise actuator closes the valve counterclockwise.
Valve off Mode
Limit switch(Default)— That is, the journey.
When the valve is running in the direction of *1.1 Turn Off direction *
shutdown, it will stop running when it reaches the
set Limit switch position. Direction: Clockwise
Torque - When the valve runs in the direction of
closing, it does not stop when it reaches the Limit Mode: Limit
switch and does not stop until the set value of Torque: 100%
closing torque.
Limit: 3000
OFF Torque
The valve closing torque of the actuator can be set between the 40%~100% range of the
rated torque. When the torque reaches the set point, the valve stops running. If the setting value
is reached 3 times continuously in the same direction, the turn off torque fault is displayed.
Valve off limit
Before unchecked, the saved data is displayed, and when the correct password is entered, the
absolute position of the current valve is displayed. Before setting up Limit switch, make sure that
the "turn off valve" is correct. To perform electric operation, please turn the way knob to "on the
spot" condition.

When setting Limit switch, the actuator must be connected to the valve. Move the valve to
the fully closed position with the remote controller or the knob key, and press the OK button to
save the shut-off Limit switch data. The minimum output revolution between a switch on Limit
and a switch on Limit is 2.5 turns (the total number of turns is visible in the "open Limit switch"),
otherwise it will not work properly.
1.2 ON
Valve On Mode *1.2 Turn ON direction *
Limit switch(Default)— The journey. When the valve is
running in ON direction, it will stop running when it Mode: Limit switch
reaches the set open Limit switch position. Torque: 100%
Torque - When the valve is running in the open direction,
Limit: 2000
it does not stop until it reaches the set opening limit and
does not stop until the set opening torque. Cycles: 1000
Moment of opening
The valve opening torque of the actuator can be set between the 40%~100% range of the rated
torque. When the torque reaches the set point, the valve stops running. If the setting value is
reached 3 times continuously in the same direction, the open torque fault is displayed.

96 after-saleservice@zeme-china.com
EGCS maintenance manual 浙江浙能迈领环境科技有限公司

Valve off limit


To perform electric operation, please turn the way knob to "on the spot" condition. When setting
Limit switch, the actuator must be connected to the valve. Move the valve to the full open
position with the setter or knob open key. Press OK to save the open Limit switch data. The
minimum output revolutions between Limit switch and Limit switch are 2.5 cycles,
otherwise they will not function properly.

Circles
Refers to the difference between Limit switch and Limit switch data. This parameter can not be
set. The number of cycles to be set must be greater than 2 cycles.1.3 Torque bypass
The output torque of the actuator can reach 150% of the rated torque within the set bypass
stroke, while the viscous valve is opened.
After setting the bypass stroke, the actuator continues to be protected according to the set
torque value.
1.3. Valve On bypass *1.3 Torque sideway *
1.4. OFF(Default)—Turn OFF the Sideway function
1.5. ON — Turn ON the bypass function On sideway OFF
1.6. Turn On Travel On Travel 0-95%
1.7. When the “valve bypass” is activated, the turn
OFF sideway OFF
off torque bypass will take effect in the
open stroke 0%-95% (Default) interval. The OFF Travel 5-100%
torque bypass position can be set to: 0%~
N% (0≤ N ≤95).
1.8. Valve OFF bypass Disabled (Default) - off by directional bypass function.
1.9. Enabled - turn on the bypass function to turn
on. *02 Instruction Feedback *
1.10. Turn OFF Travel
1.11. “Turning off the valve bypass” will enable 01.Relay Groups
the turn off torque bypass to take effect in 02.Local display
the 5%-100% (Default) interval. The torque
03.Simulation Feedback
bypass position can be set to: N%~ 100% (5
≤N ≤100).

三、常见故障及排查措施
The Common Failures and Troubleshooting Database
故障现象 可能原因 排查措施
Failure Possible Causes Root Cause Validations
Phenomenon
显示“电源缺相” 三相电源缺相 检查执行器电源进线处线路是否有缺相;中
No phase with Phase loss of three phase 间线路是否接好
Power supply power supply Check whether there is phase missing in the
power supply line of the actuator, and whether
the intermediate line is connected properly.
显示“开过力矩” 开阀过程中执行器过力矩 如正常使用中出现此现象,适当调整大当前
Torque exceed Over torque of actuator during 力矩(参考 3.1.2 开方向—力矩)
limits valve opening process If there is such a phenomenon in normal
operation, adjust the large current torque
properly (refer to 3.1.2 open direction torque).
显示“关过力矩” 关阀过程中执行器过力矩 如正常使用中出现此现象,适当调整大当前
Valve exceed Over torque of actuator during 力矩(参考 3.1.1 关方向—力矩)
torque limits valve turning off process If there is such a phenomenon in normal

after-saleservice@zeme-china.com 97
浙江浙能迈领环境科技有限公司 EGCS maintenance manual

operation, adjust the large current torque


properly (refer to 3.1.2 OFF direction torque).

显示“编码器停 执行器箱体内部输出轴和编 打开电器罩检查编码器耦合情况;电机是否


转”Encoder stop 码器未耦合;或电机未转 损坏
The inner output shaft of the Turn on the electrical cover and check the
actuator box is not coupled encoder coupling. Or the motor damaged.
with the encoder, or the motor
is not rotating.
显示“编码器故 编码器接线端子脱开 开盖检查编码器连线是否接好
障” Encoder terminal disconnect Open the lid and check if the encoder is
Encoder stop connected properly.
显示“转向错误” 阀门运行方向与设定方向相 重新设置行程
Wrong turn 反 The direction of valve Reset travel
directions operation is opposite to the
setting direction
显示“信号丢失” 未接收到远方模拟控制信号 检查线路中是否有正确的模拟信号,正负极
Signal missing Remote analog control signal is 是否接反。
not received. Check whether there is a correct analog signal
in the circuit and whether the positive and
negative poles are reversed.
参 数 故 障 行程设定出错 重新设定行程
Parameters issues Wrong travel settings Reset travel
远方控制信号无 查看执行器是否显示出现其他故障
法控制 红色旋钮是否旋到远程
No control with 检查控制回路是否接好
remote controlled 检查执行器参数联锁控制
signal Check if the executor is showing any other
faults.
Does the red knob turn to remote?
3.Check whether the control circuit is properly
connected.
4.Check the interlock control of actuator
parameters.

98 after-saleservice@zeme-china.com