Suto S461 en 22-1
Suto S461 en 22-1
Suto S461 en 22-1
S461
Ultrasonic Flow Meter
for Liquids (Clamp-On)
Transducers
flow TF TR
www.suto-itec.com
S461 TECHNICAL DATA
Measurement General data
Flow Configuration
Accuracy 1.0 % o. RDG +-0.01 m/s Wireless S4C-US App for mobile phones
Selectable units
Metric: m/s, m³/h, m³/min, l/min, m³ Display
Imperial:ft/min, cfm, cfs, USG/min, IG/min, bbl/min 2.4” color (640 x 480) graphic display, 1 touch
Size/Resolution
Measuring range 0 ... 12 m/s button
Repeatability 0.2 % of reading Data Logger
Sensor Ultrasonic sensor Storage 8 Mio. values
Sampling rate 5 samples / sec Material
Turndown ratio 50:1 Main Casing PC + ABS
Response time (t90) 0.1 sec UT-S: Industrial synthetic plastics
Sensor
Consumption UTH-S: Aluminum
Metric: m³, l Miscellaneous
Selectable units
Imperial: cf, IG, UG, bbl 2 x M12 D code (4 pole): transducer
Temperature Electrical connection
2 x M12 (5 pole): Signals/Supply. (8-pole x-coded)
Accuracy 0.5 °K for TCP
2 x M8 (4 pole): Pt1000 (Energy Meter Version)
Selectable units Metric: °C. Imperial: °F
Protection class Main casing: IP65. Sensors: IP68
Measuring range -40 ... +130 °C
Approvals CE, RoHS, FCC
Sensor Pt1000
Weight 1.2 kg
Energy Flow
Main unit: 124 x 102 x 70 mm
Metric: GJ/h, kJ/h, kcal/h
Selectable units Dimensions UT-S sensor: 64 x 30 x 27 mm
Imperial: MBtu/h, Btu/h
UTH-S sensor: 68 x 34 x 34 mm
Energy Operating conditions
Metric: GJ, kJ, kcal, kWh, MWh
Selectable units All acoustically conductive liquids with less than
Imperial: Mbtu, Btu Fluids
10 % gaseous
Signal / Interface & Supply Medium temperature -40 ... +130 °C
Analog output (Option) Main unit: 0... +50 °C
Signal 4 ... 20 mA (4-wire), isolated Ambient temperature UT-S sensor: 0... +80 °C
Scaling 0 ... max flow, freely adjustable UTH-S sensor: -40... +130 °C
Load max. 250 Ohm Ambient humidity < 99 % rH
Update rate 300 msec Storage temperature -30 ... +70 °C
Pulse output (Option) Transport temperature -30 ... +70 °C
Signal Switch output, normally open, max. 30 VDC, 20 mA Pipe sizes DN40 ... DN1200
Scaling 1 pulse per consumption unit (selectable)
Fieldbus Flow Ranges:
Modbus/RTU (Standard)
Protocol DN DO Max flow
Modbus/TCP and PoE (Option)
Supply mm mm l/min m3/h cfm
Voltage supply 20 ... 28 VDC 40 48 905 54 32
Current consumption 150 mA @ 24 VDC 50 60 1.414 85 50
65 76 2.389 143 84
80 88 3.619 217 128
S461 ORDERING
Visit our website or e-mail us:
www.suto-itec.com
sales@suto-itec.com
Please use the following tables to assist in placing your
order with our sales staff.
Useful Accessories
Order No. Description
Metal stretcher for sensor installation on pipes
A695 4601 DN40 ... DN65 (2 pieces)
A695 4602 DN80 ... DN100 (2 pieces) International Edition (EN) - 22-1. © 2022 SUTO iTEC GmbH. www.suto-itec.com
A695 4603 DN125 ... DN150 (2 pieces)
A695 4604 DN200 ... DN300 (2 pieces)
A695 4605 DN350 ... DN500 (2 pieces)
A695 4608 Belt stretcher for temporary sensor installations (portable unit), DN40 ... DN500 (2 pieces)
A695 4610 Coupling agent for sensor installation, 65 g
A554 4625 Transport casing S461 dimensions: 560 x 450 x 160 mm
A554 0107 Plug-in power supply, 100 ... 240 VAC / 24 VDC, 0.5 A , 1.5 m cable M12 connector. Recommended for portable unit
A553 0154 Cable to connect power bank, 1.8 m, USB-C connector for power bank, M12 connector
A553 0104 Sensor cable, 5 m, with M12 connector, open wires, AWG24 (0.2 mm²)
A553 0105 Sensor cable, 10 m, with M12 connector, open wires, AWG24 (0.2 mm²)
Calibration & Services
Order No. Description
R200 4610 Calibration S461 together with transducer pair
R200 4613 Calibration temperature sensor S461