General Model TDLS8000

Tunable Diode Laser Spectrometer


Specifications
GS 11Y01D01-01EN

n Overview
Yokogawa’s new TDLSTM8000 houses all of the
industry’s leading features in one robust device.
The platform design is for in situ measurements
which negate the need for sample extraction and
conditioning.
The non-contacting sensor allows for a variety of
process types including corrosive, abrasive and
condensing.
The first generation platform has been proven in many
others for the measurements of O2, CO, CH4, NH3,
H2O and many more NIR absorbing gases.
This second generation platform has improved TDLS8000 Tunable Diode Laser Spectrometer
reliability and ease of installation and maintenance
while still meeting or exceeding designed application
demands.

 Features
• SIL2, TruePeakTM combined with smart laser - Purge gas is no need for explosion protection.
technology • In-situ or extractive analysis and fast response
- Measurement integrates the area of the absorbance (2-5 seconds, 1 second (optional))
and gets a true, interference-free analysis under • Process pressures up to 1 MPa abs. and process
changing pressure, temperature and background temperatures up to 1,500ºC (Note)
- Laser module is replaceable on site without any Note: Maximum process temperatures and pressures
calibration or adjustment will vary by application
- Internal reference cell in the laser module ensures *1: Total Cost of Ownership
*2: Mean Time To Failure
peak locking during trace measurement
- Laser and Detector modules are sealed to protect • 10 language display options
them from dirty purge gas YH8000 offers easy touch screen operation and
- On board diagnostics and low TCO(*1) (no moving simple menu structure in 10 languages. Menus of
parts, high MTTF(*2) for components) display, execution and setting are displayed in a
- IEC61508 SIL designed & approved, SIL 2 capability selected language.
for single analyzer use, SIL 3 capability for dual
analyzer use (except H2O (%) analyzer) Typical gases measured include:
• Intuitive touchscreen HMI • Oxygen in process and combustion applications.
- Large HMI provides easy operation and control of Process temperatures can be as high as 1,500ºC,
up to 4 analyzers at the same time·A standard mini and process pressures can be as high as 1 MPa abs.
display at both sides enables easy optical alignment Measurement span is typically between 1% and 25%
• HART and Modbus TCP communications oxygen.
standard • Carbon monoxide in process and combustion
applications. Process temperatures can be as high as
• 8-stage auto-gain adapts to difficult applications 1,500ºC. Two versions are available, high sensitivity
- Auto-gain enables wide signal ranges against with ppm detection limits, and standard sensitivity for
dynamic variation of transmission. higher ppm and percent level CO measurement
• Fully field repairable with 50 days of data and
spectra storage Other applications and gas measurements are possible
• Compact design for one-man installation without with the TDLS8000. Please fill out the Application
sacrificing ruggedness Data Sheet at the end of this document and send to
- IECEx, ATEX, FM(US, Canada), Korea Ex, NEPSI, Yokogawa.
EAC, INMETRO, Japan hazardous area approvals
based on Nonincendive/Type n or Explosionproof/
flame proof.

TDLS, TruePeak are trademarks or registered trademarks of Yokogawa Electric Corporation.


All other company and product names mentioned in this document are trademarks or registered trademarks of their respective companies.

Please select appropriate equipment in accordance with the laws and regulations of the relevant country/region, when it is used in a location where explosive atmospheres may be present.

Yokogawa Electric Corporation GS 11Y01D01-01EN


2-9-32, Nakacho, Musashino-shi, Tokyo, 180-8750 Japan ©Copyright Apr. 2015
23rd Edition Nov. 01, 2023
2
 System configuration
Standard System Configuration

Laser unit (LU) Sensor control unit (SCU)

Measured gas

Flow meter Flow meter


24V DC±10%

Unit connection cable

Purge line for Optic Purge line for Process window Purge line for Process window Purge line for Optic

System Configuration with YH8000 HMI Unit and Validation gas line

Laser unit (LU) Sensor control unit (SCU)

Measured gas

Flow meter Flow meter


24V DC±10%

Unit connection cable


Purge line for Process window
Purge line for Optic Purge line for Optic
Purge line for Process window
Check gas line

All Rights Reserved. Copyright © 2015, Yokogawa Electric Corporation GS 11Y01D01-01EN Nov. 01, 2023-00
3
Multi Analyzer Configuration with Remote HMI

Laser unit (LU) Sensor control unit (SCU)

Measured
gas

24V DC
±10%

Measured
gas

24V DC±10%

Measured
gas

24V DC±10%

Measured
gas

Flow meter Flow meter 24V DC±10%


Switching HUB
Unit connection cable

24V DC±10%

YH8000 HMI Unit

Note: If power supply is 100 to 240 V AC, purchase the Universal Power Supply, separately.
If four multi analyzer configuration with remote HMI is made, five universal power supply including YH8000 are needed.

All Rights Reserved. Copyright © 2015, Yokogawa Electric Corporation GS 11Y01D01-01EN Nov. 01, 2023-00
4
 STANDARD SPECIFICATIONS EMC conformity standards:
CE, UKCA EN55011 Class A Group 1
TDLS8000 Tunable Diode Laser Spectrometer EN61326-1 Class A Table 2 (For use in
industrial location), EN61326-2-3
Measurement object: RCM EN55011 Class A Group 1
O2, CO, CO or CH4, CO2, CO + CO2, KC KN11 Class A Group 1, KN61000-6-2
H2O, NH3, H2S, HCl concentration in (Korea Electromagnetic Conformity)
combustion exhaust gas and process gas RoHS conformity standards: EN IEC 63000:2018*
If other gas measurements are required, *: For only TDLS8000-G1, -G2, -S1, -S2
consult with Yokogawa Information of the WEEE Directive
Measurement system: This product is purposely designed to be used in a
Tunable diode laser spectroscopy large scale fixed installations only and, therefore,
Light source; Near-infrared tunable diode laser is out of scope of the WEEE Directive. The WEEE
Measured components and ranges: Directive does not apply.
Measured component Min. range Max. range The WEEE Directive is only valid in the EU and UK.
O2 0-1% 0-25% Laser classification: CAN/CSA-E60825-1-15,
CO (ppm) 0-200 ppm 0-10,000 ppm CE, UKCA EN 60825-1:2014, FDA 21CFR
CO 0-200 ppm 0-10,000 ppm part 1040.10, GB7247.1-2012, Class 1
CO or CH4 (*3) laser product
CH4 0-5%
NH3 0-30 ppm 0-5,000 ppm SIL Certification: The TDLS8000 expect digital output
(2 points), digital input (2 points), valve
H2O (ppm) in non HC (*1) 0-30 ppm 0-30,000 ppm
control output (2 points), and digital
H2O (ppm) in HC (*2) 0-30 ppm 0-30,000 ppm communications (HART, Modbus/TCP) are
CO (%) 0-20% 0-50% certified in compliance with the following
CO (%) + CO2 (%) 0-30% 0-100% standard.
H2S 0-5% 0-100% IEC 61508:Functional safety of Electrical/
CO2 (%) High Range 0-1% 0-5% electronic/programmable electronic related
CO2 (%) Extend. Range 0-30% 0-50% systems; SIL 2 capability for single analyzer
use, SIL 3 capability for dual analyzer use.
H2O (%) 0-10% 0-100% (*4)
( H2O (%) analyzer is not applicable)
HCl 0-50 ppm 0-5,000 ppm Marine certification: DNV Type Approval
*1: Non hydrocarbon background. Certificate No: TAA000030E
*2: Hydrocarbon background. URL: https://approvalfinder.dnv.
*3: Please consult with Yokogawa if CO or CH4 com/#approval/TAA000030E
ingredient coexists. (For only TDLS8000/WCD)
*4: If it exceeds 50%, please consult with Yokogawa. Display: 128 x 64 dots LCD; On Sensor Control Unit
Please consult with Yokogawa if the measuring range Status LEDs; 3 on Sensor Control Unit (Green:
for your sample gas is outside of the above ranges Power, Orange: DO, Red: Fault)
Optical path length: 4 digit 7-segment LEDs: On Laser Unit
Optical distance between the laser unit Display items:
and the sensor control unit LCD on Sensor Control Unit; Gas concentration,
Standard; 0.5 to 6 m (Application dependent) Transmission, Process gas temperature
Max; 30 m (With optional Large Aperture (AI), Process gas pressure (AI), System
Optics (LAO)) status, Alarm information, System
25 m (Zone 1/Div.1/Flameproof “d” with LAO) information (Product serial no., Laser
Note: LAO unit can be selected only with analyzers for module serial no., Output signal, IP
O2, CO(ppm) and CO+CH4. address, HART address, Optical path
If your optical path length is under 0.5 m or over length, Analyzer internal temperature)
30 m, please consult with Yokogawa. 7-segment LEDs on Laser Unit; Transmission
Safety, EMC, and RoHS conformity standards: Analog output: 2 points, 4 to 20 mA DC (Isolated from
Safety conformity standards: the power supply and ground, Max. load
CE, UKCA EN61010-1, EN61010-2-030 resistance 550 Ω)
UL UL61010-1, UL 61010-2-030 Output types; Gas concentration, Transmission,
CSA CAN/CSA-C22.2 No.61010-1, CAN/ Process gas temperature, Process
CSA-C22.2 No.61010-2-030 gas pressure
GB GB30439 Part 1 Output range; 3.0 to 21.6 mA DC
Installation altitude: 2000 m or less Digital communications:
Installation category: HART; On analog output signal 1 (AO-1)
I (Anticipated transient overvoltage 330V) Load resistance; 250 to 550 Ω (Include cable resistance)
Measuring category: O (Other) Ethernet; RJ-45 connector in Sensor Control Unit
Pollution degree: 2, Indoor/Outdoor use Protocol; Modbus/TCP
Note: Installation category, called overvoltage category, Communication speed; 100 Mbps
specifies impulse withstand voltage. Pollution Digital output: 2 points, contact rating 24V DC, 1A
degree indicates the degree of existence of solid, DO;
liquid, gas or other inclusions which may reduce Function: Activate during Warning / Calibration
dielectric strength. / Validation / Warm up / Maintenance
conditions

All Rights Reserved. Copyright © 2015, Yokogawa Electric Corporation GS 11Y01D01-01EN Nov. 01, 2023-00
5
Contact Specification: Relay contact output Note: Validation check is not available when Large
(Isolated from the power supply and Aperture Optics “-LA” of the Optic Accessory
ground), C-contact (NC/NO/COM) is specified or H20 ppm measurement “-H1” of
Fault; the Gas Parameter is specified. As well, when
gas concentration is unstable, please consult
Function: Activate during Fault condition or when Yokogawa.
the system power is off Power supply: 24V DC +/-10%
Contact Specification: Relay contact output If your power supply is 100 to 240 V AC,
(Isolated from the power supply and Universal Power Supply, M1276WW (sold
ground), A-contact (NC/COM) separately), is required
Valve control output: 2 points Power consumption:
Function; Activate calibration or validation solenoid Max. 20W; TDLS8000 only
valves for zero, span or validation gas. Max. 60W; TDLS8000 with YH8000 and 2 solenoid valves
Output signal; 24V DC, 500 mA Max. per terminal Protection degree: IP66, Type 4X
Alarm: Material: Case; Aluminum alloy
Warning; Gas concentration low, Gas concentration Wetted materials:
high, Transmission low, Process pressure 316 SS, BK-7 glass, Teflon encapsulated
low, Process pressure high, Process FKM (O-ring for alignment flange), Silicone
temperature low, Process temperature (O-ring for LAO)
high, Validation required, Validation Paint color: Mint green (RAL 190 30 15 or equivalent)
failure, Zero calibration error, Span Weight:
calibration error, Non process alarm, Sensor Control Unit; Approx. 8 kg
External alarm, Detector signal high, Laser Unit; Approx. 8 kg
Absorption too high Large Aperture Optics; Approx. 14 kg
Fault; Laser module temperature low, Laser ANSI Class 150-2-RF (Eq.) Alignment Flange;
module temperature high, Laser Approx. 5 kg/pc
temperature low, Laser temperature high, ANSI Class 150-3-RF (Eq.) Alignment Flange;
Peak center out of range, Reference peak Approx. 7 kg/pc
height low, Transmission lost, Reference ANSI Class 150-4-RF (Eq.) Alignment Flange;
transmission low, Reference peak height Approx. 9 kg/pc
high, Laser unit failure, Laser module error, DIN PN16-DN50-A (Eq.) Alignment Flange;
File access error, E2PROM access error Approx. 5 kg/pc
Digital input: 2 points DIN PN16-DN80-A (Eq.) Alignment Flange;
Function; External Alarm/Calibration start/ Approx. 6 kg/pc
Validation start/Stream switch (Valve JIS 10K-50-FF (Eq.) Alignment Flange;
control) Approx. 5 kg/pc
Contact specification; Zero voltage contact input JIS 10K-80-FF (Eq.) Alignment Flange;
(Isolated from the power supply and Approx. 6 kg/pc
ground) Flow Cell Alignment Flange; Approx. 5 kg/pc
Input signal; Open signal: 100 kΩ or more, Close Cable gland for Japan Ex “-J1”; (/JA1) Approx. 320 g/pc,
signal: 200 Ω or less (/JB3, /JB4) Approx. 450 g/pc
Analog input: 2 points Cable gland for Japan Ex “-J2”;
Signal type; 4 to 20 mA DC (Isolated from (/JC1, /JD1) Approx. 150 g/pc,
the power supply and Ground), with (/JE3, /JE4) Approx. 200 g/pc
selectable powered/unpowered function Process gas condition:
Input signal range; 2.4 to 21.6 mA DC Process gas temperature; Max. 1,500ºC,
Input types; Process gas temperature, Process Application dependent
gas pressure Process gas pressure; Max.1 MPa abs., Min. 90 kPa
Transmitter power supply; 15 V DC or higher (at 20 mA DC) abs., Application dependent
26 V DC or less (at 0 mA DC) Max. 15 kPa G with LAO unit
Note: This voltage is generated between the AI terminals
Note: When using TDLS8000 as CE/UKCA marking
of TDLS8000. When calculating the minimum
compliance product, it has following limitation.
operating voltage for transmitters, consider to allow
General purpose model (-G1, -G2):
margins for voltage drop in external wiring.
The upper limit of the measurement gas
Self-diagnostics: pressure is 50kPa in gauge pressure.
Laser Unit temperature, Sensor Control  Consult with Yokogawa Europe B.V. in the
Unit temperature, Laser temperature, case of witnessing high pressure in Europe.
Detector signal level, Memory read/write ATEX model (-S1, -S2):
function, Peak locking condition The upper limit of the measurement gas
Calibration: pressure is 500kPa abs. The unstable gas
Calibration method; Zero/Span calibration defined by following cannot be measured.
Calibration mode; Manual, Auto (Time initiate, An unstable gas in this context is a gas liable to
transform itself spontaneously, producing a sudden
Remote initiate (DI/Modbus)), Semi-Auto pressure increase.
(YH8000/HART) Such transformation as an example can result
Validation: from a relatively small variation of an operating
Validation method; Up to 2 points parameter (e.g. pressure, temperature, presence
Validation mode; Manual, Auto (Time initiated, of catalyzing material) in a confined volume.
Remote initiate (DI/Modbus)), Semi-Auto This includes gases that are classified as
(YH8000/HART) chemically unstable gases according to CLP
Regulation (EC) No 1272/2008 as amended.

All Rights Reserved. Copyright © 2015, Yokogawa Electric Corporation GS 11Y01D01-01EN Nov. 01, 2023-00
6
Typical examples of unstable gases: acetylene Zone system:
(UN 1001), methyl acetylene (UN 1060), Type of protection:
vinylfluoride (UN 1860), ozone and dinitrogen Class I, Zone 1, AEx db [op is T6 Ga]
oxide (UN 1067). IIC T5 Gb
For further examples, see Table 35.1 of the UN
Manual of Tests and Criteria.
Zone 21, AEx tb [op is T85˚C Da] IIIC
Dust in process gas; 20 g/m3 or less T100˚C Db
(Dust loading levels are dependent Enclosure rating: IP66
upon the application, OPL and other Applicable standards:
installation factors) ANSI/UL 60079-0:2019
Warm-up time: 5 min. ANSI/UL 60079-1:2015
Installation condition: ANSI/UL 60079-28:2017
Ambient operating temperature; -20 to 55ºC ANSI/UL 60079-31:2015
Storage temperature; -30 to 70ºC ANSI/IEC 60529:2004
Humidity; 0 to 95%RH at 40ºC (Non-condensing) TDLS8000-C1 (FM Approval for Canada)
Mounting flange type; ASME B16.5, DIN, JIS Type of protection:
Cable entries; Ex db [op is T6 Ga] IIC T5 Gb
Sensor Control Unit: 1/2NPT or M20x1.5mm,one hole Class II/III, Division 1, Groups E, F, G, T5
3/4NPT or M25x1.5mm, three holes Ex tb [op is T85˚C Da] IIIC T100˚C Db
Laser Unit: 3/4 NPT or M25x1.5mm, one hole Enclosure rating: IP66, Type4X
Purge gas connections; Applicable standards:
1/4NPT or Rc1/4 CAN/CSA-C22.2 No.0:2010 (R2015)
If other gas connections are required, CSA-C22.2 No. 0.4:2017
please consult with Yokogawa. CSA C22.2 No. 0.5:2016
Purge gas; Theoretically, instrument air could be used as CSA C22.2 No. 25:2017
a purge gas for all of the below applications CSA C22.2 No.94.2:2015
except for oxygen or H2O measurement. CAN/CSA-C22.2 No.61010-1:2012
Choosing between using nitrogen or CAN/CSA-C22.2 No.61010-2-030:2012
instrument air or purge gas will ultimately CAN/CSA-C22.2 No.60529:2016
depend upon further application details and CSA C22.2 No.60079-0:2019
the desired precision of the measurement. All CAN/CSA-C22.2 No.60079-1:2016
gasses should be clean and dry. CAN/CSA-C22.2 No.60079-28:2016
Recommended purge gasses: CAN/CSA-C22.2 No.60079-31:2015
O2 analyzer: N2 (99.99% or greater, application ANSI/ISA 12.27.01:2011
dependent) TDLS8000-S1 (ATEX)
H2O ppm analyzer: N2 (99.99% or greater with Type of protection:
< 20 ppm H2O for feed to the optional II 2(1) G Ex db [op is T6 Ga] IIC T5 Gb
dryer package) II 2(1) D Ex tb [op is T85˚C Da] IIIC
CO, CO or CH4, CO2, CO + CO2, NH3, H2S, HCl T100˚C Db
analyzer: N2 (99.99% or greater, Enclosure rating:
application dependent) or Instrument air IP66 (In Accordance with EN 60529)
Purge gas flow rates; Applicable standards:
Optic: Application dependent (typ. 2 to 20L/min) EN IEC 60079-0:2018
2 to 20L/min and 50 to 70mL/min EN 60079-1:2014, EN 60079-28:2015,
(Zone 1/Div.1/Flameproof “d”) EN 60079-31:2014
* Not more than 10kPa at the inlet for TDLS8000-E1 (IECEx)
Zone 1/Div.1/Flameproof “d” and Zone Type of protection:
2/Div.2/Type of protection “n” Ex db [op is T6 Ga] IIC T5 Gb
Process window: Application dependent Ex tb [op is T85˚C Da] IIIC T100˚C Db
(typ. 5 to 30L/min) Enclosure rating:
Hazardous area classifications: IP66 (In Accordance with IEC 60529)
Applicable standards:
Division 1, Zone 1: Explosionproof IEC 60079-0:2017, IEC 60079-1:2014,
TDLS8000-D1 (FM Approval for US) IEC 60079-28:2015, IEC 60079-31:2013
Division system: TDLS8000-K1 (Korea Ex)
Type of protection: Type of protection:
Explosionproof for Class I, Division 1, Ex db IIC T5 Gb
Groups A, B, C, D, T5 Ex tb IIIC T100˚C Db
Dust-Ignitionproof for Class II/III, Enclosure rating:
Division 1, Groups E, F, G, T5 IP66 (In accordance with IEC 60529)
Enclosure rating: Type4X Applicable standards:
Applicable standards: Notice of Ministry of Labor No. 2021-
FM Class 3600: 2018 22 Harmonized with IEC 60079-0:
FM Class 3615: 2018 2017, IEC 60079-1: 2014, IEC 60079-
FM Class 3616: 2011 31: 2013
FM Class 3810: 2018
ANSI/NEMA250: 2003

All Rights Reserved. Copyright © 2015, Yokogawa Electric Corporation GS 11Y01D01-01EN Nov. 01, 2023-00
7
TDLS8000-J1 (Japan Ex) TDLS8000-C2 (FM Approval for Canada)
Type of protection: Ex db IIC T5 Gb Type of protection:
Applicable standards: Ex nA nC [op is T6 Ga] IIC T5 Gc
JNIOSH-TR-46-1:2015 Ex tb [op is T85˚C Da] IIIC T100˚C Db
JNIOSH-TR-46-2:2018 Class II/III, Division 1, Groups E, F, G, T5
TDLS8000-N1 (NEPSI) Enclosure rating: IP66, Type 4X
Type of protection: Applicable standards:
Ex db [op is T6 Ga] IIC T5 Gb CSA C22.2 No. 25:2017
Ex tb [op is T85°C Da] IIIC T100°C Db CSA C22.2 No.94.2:2015
Enclosure rating: CAN/CSA-C22.2 No.60529:2016
IP66 (In accordance with GB/T 4208-2017) CAN/CSA-C22.2 No. 60079-0:2019
Applicable standards: CAN/CSA-C22.2 No.60079-15:2016
GB/T 3836.1-2021 CAN/CSA-C22.2 No.60079-28:2016
GB/T 3836.2-2021 CAN/CSA-C22.2 No.60079-31:2015
GB/T 3836.22-2017 CAN/CSA-C22.2 No.61010-1:2012
GB/T 3836.31-2021 CAN/CSA-C22.2 No.61010-2-030:2012
TDLS8000-Q1, -R1 (EAC) ANSI/ISA 12.27.01:2011
Type of protection: TDLS8000-S2 (ATEX)
1Ex db [op is T6 Ga] IIC T5 Gb X Type of protection:
Ex tb [op is T85˚C Da] IIIC T100˚C Db X II 3(1) G Ex nA nC [op is T6 Ga] IIC T5 Gc
Enclosure rating: II 2(1) D Ex tb [op is T85˚C Da] IIIC
IP66 (In accordance with GOST 14254) T100˚C Db
Applicable standards: Enclosure rating:
GOST 31610.0-2014 IP66 (In accordance with EN 60529)
GOST IEC 60079-1-2013 Applicable standards:
GOST 31610.28-2017 EN IEC 60079-0:2018,
GOST IEC 60079-31-2013 EN 60079-15: 2010,
TDLS8000-U1 (INMETRO) EN 60079-28: 2015,
Type of protection: EN 60079-31: 2014
Ex db [op is T6 Ga] IIC T5 Gb TDLS8000-E2 (IECEx)
Ex tb [op is T85˚C Da] IIIC T100ºC Db Type of protection:
Enclosure rating: IP66 Ex nA nC [op is T6 Ga] IIC T5 Gc
Applicable standards: Ex tb [op is T85˚C Da] IIIC T100˚C Db
ABNT NBR IEC 60079-0:2020 Enclosure rating:
ABNT NBR IEC 60079-1:2016 IP66 (In accordance with IEC 60529)
Versão Corrigida:2020 Applicable standards:
ABNT NBR IEC 60079-28:2016 IEC 60079-0:2017, IEC 60079-15: 2010,
Versão Corrigida:2021 IEC 60079-28: 2015, IEC 60079-31: 2013
ABNT NBR IEC 60079-31:2014 TDLS8000-K2 (Korea Ex)
Type of protection: Ex nA nC IIC T5 Gc
Division 2, Zone 2: Nonincendive/Type n Ex tb IIIC T100˚C Db
TDLS8000-D2 (FM Approval for US) Enclosure rating:
Division system: IP66 (In accordance with IEC 60529)
Type of protection: Applicable standards:
Nonincendive for Class I, Division 2, Notice of Ministry of Labor No. 2021-22
Groups A, B, C, D, T5 Harmonized with IEC 60079-0: 2017,
Dust-Ignitionproof for Class II/III, IEC 60079-15: 2010, IEC 60079-31:
Division 1, Groups E, F, G, T5 2013
Enclosure rating: Type 4X TDLS8000-N2 (NEPSI)
Applicable standards: Type of protection:
FM Class 3600: 2018 Ex nA nC [op is T6 Ga] IIC T5 Gc
FM Class 3611: 2018 Ex tD A21 IP66 T100ºC
FM Class 3616: 2011 Enclosure rating:
FM Class 3810: 2018 IP66 (In accordance with GB 4208)
ANSI/NEMA250: 2003 Applicable standards:
Zone system: GB 3836.1-2010, GB 3836.8-2014,
Type of protection: GB 12476.1-2013, GB 12476.5-2013,
Class I, Zone 2, AEx nA nC [op is T6 IEC 60079-28:2015
Ga] IIC T5 Gc TDLS8000-Q2, -R2 (EAC)
Zone 21, AEx tb [op is T85˚C Da] IIIC Type of protection:
T100˚C Db 2Ex nA nC [op is T6 Ga] IIC T5 Gc X
Enclosure Rating: IP66 Ex tb [op is T85ºC Da] IIIC T100ºC Db X
Applicable standards: Enclosure rating:
ANSI/UL 60079-0:2019 IP66 (In accordance with GOST 14254)
ANSI/UL 60079-15:2013
ANSI/UL 60079-28:2017
ANSI/UL 60079-31:2015
ANSI/IEC 60529:2004

All Rights Reserved. Copyright © 2015, Yokogawa Electric Corporation GS 11Y01D01-01EN Nov. 01, 2023-00
8
Applicable standards: Data Update Cycle:
GOST 31610.0-2014 Standard; Approx. 2 seconds (Response
GOST 31610.15-2014 time may increase for non-standard
GOST 31610.28-2017 applications)
GOST IEC 60079-31-2013 If less than 2 seconds response is
TDLS8000-U2 (INMETRO) required, please consult with Yokogawa
Type of protection: Zero Drift: Typically <0.1% of the minimum range
Ex nA nC [op is T6 Ga] IIC T5 Gc over 24 months
Ex tb [op is T85ºC Da] IIIC T100ºC Db Influences on the Measurement - Application
Enclosure rating: dependent
IP66 A. Temperature: The temperature of the measured
Applicable standards: gas should be taken into account by the analyzer
ABNT NBR IEC 60079-0:2020 so that the reading can be corrected on a real
ABNT NBR IEC 60079-15:2019 time basis. The effect is specific to each different
ABNT NBR IEC 60079-28:2016 measurement gas.
Versão Corrigida:2021 a. If the gas temperature is constant at the
ABNT NBR IEC 60079-31:2014 desired measurement condition, then a fixed
TDLS8000-J2 (Japan Ex) gas temperature may be programmed into the
Type of protection: analyzer. This fixed value can be used in real
Ex nA nC [op is T6 Ga] IIC T5 Gc time by the analyzer to provide a temperature-
Ex tb [op is T85ºC Da] IIIC T100ºC Db compensated reading.
Applicable standards: b. If the gas temperature is relatively equal to the
JNIOSH-TR-46-1:2020 ambient temperature, then an integral sensor
JNIOSH-TR-46-8:2015 value may be utilized by the analyzer. This
JNIOSH-TR-46-9:2018 active ambient value is used real time by the
JNIOSH-TR-46-11:2020 analyzer to provide a temperature compensated
Enclosure rating: reading.
IP66 (In accordance with IEC 60529) c. If the gas temperature is variable, then an
external sensor value may be utilized by
PERFORMANCE the analyzer. This active input value can be
Repeatability / Linearity: used in real time by the analyzer to provide a
Measured gas Repeatability Linearity temperature compensated reading.
B. Pressure: The pressure of the measured gas must
+/- 1% reading or +/- 0.01
O2
%O2, whichever is greater
+/- 1% F.S. be taken into account by the analyzer so that the
reading can be corrected on a real time basis. The
+/- 2% reading or +/- 1 ppm
CO (ppm) +/- 1% F.S. effect is specific to each different measurement
CO, whichever is greater
gas.
+/- 2% reading or +/- 1 ppm a. If the gas pressure is constant at the desired
CO +/- 2% F.S.
CO or CO, whichever is greater
measurement condition, then a fixed gas
CH4 +/- 4% reading or +/- 0.02%
CH4 +/- 4% F.S. pressure may be programmed to the analyzer.
CH4, whichever is greater
This fixed value can be used in real time by the
+/- 2% reading or +/- 1 ppm analyzer to provide a pressure compensated
NH3 +/- 2% F.S.
NH3, whichever is greater reading.
H2O (ppm) in +/- 2% reading or +/- 0.1 ppm b. If the gas pressure is variable, then an external
+/- 1% F.S.
non HC H2O, whichever is greater sensor value may be utilized by the analyzer.
H2O (ppm) in +/- 2% reading or +/- 0.1 ppm This active input value can be used in real
+/- 1% F.S
HC H2O, whichever is greater time by the analyzer to provide a pressure
+/- 1% reading or +/- 0.01% compensated reading.
CO (%) +/- 1% F.S.
CO, whichever is greater
+/- 1% reading or +/- 0.1% ● YH8000 HMI Unit
CO (%) CO CO, whichever is greater +/- 1% F.S.
+ CO2 The YH8000 is an HMI designed specifically for the
(%) +/- 1% reading or +/- 0.1% TDLS8000 series. The YH8000 features an easy-to-
CO2 +/- 1% F.S.
CO2, whichever is greater use touchscreen 7.5 inch color LCD which can be
+/- 1% reading or +/- 0.005% used to display maintenance information, display alarm
H2S +/- 1% F.S.
H2S, whichever is greater statuses and records, and set all parameters of the
CO2 (%) +/- 1% reading or +/- 0.005% TDLS8000.
+/- 1% F.S.
High Range CO2, whichever is greater
The YH8000 can be installed directly on the TDLS8000
CO2 (%) +/- 1% reading or +/- 0.02% series or installed remotely.
+/- 1% F.S.
Extend. Range CO2, whichever is greater
+/- 1% reading or +/- 0.02% An Ethernet connection is used to connect the YH8000
H2O (%) +/- 2% F.S. to up to four TDLS8000 series simultaneously via a
H2O, whichever is greater
+/- 1% reading or +/- 2.5 ppm
hub.
HCl +/- 2% F.S.
HCl, whichever is greater
Measurement conditions: Gas temperature; 25 ºC, Gas Display:Touchscreen 7.5 inch TFT color LCD
pressure; 0.1 MPa, Optical path panel, 640 x 480 (VGA)
length; 1 m Communication: Ethernet; RJ-45 connector

All Rights Reserved. Copyright © 2015, Yokogawa Electric Corporation GS 11Y01D01-01EN Nov. 01, 2023-00
9
Communication speed; 100 Mbps Applicable standards:
Case: Aluminum alloy CAN/CSA No.94.2-07 (R2012)
Paint color: Mint green (RAL 190 30 15 or equivalent) CAN/CSA-C22.2 No.60079-0:19
Protection degree of enclosure: IP65, Type 4X CAN/CSA-C22.2 No.60079-11:14
Window: Polycarbonate CAN/CSA-C22.2 No.60079-15:16
Weight: Approx. 4 kg CAN/CSA-C22.2 No.61010-1-12
Cable gland for Japan Ex; (/JA1, /JA2) Approx. 320 g/pc CAN/CSA No.60529:05 (R2010)
Mounting: Analyzer mount (Front, left-side, right-side) YH8000-S2 (ATEX)
with tilt function, Pipe mount, or Panel Type of protection: II 3 G Ex nA ic IIC T5 Gc
mount (Stainless steel) Enclosure rating:
Cable Entries: 1/2NPT or M20x1.5 mm, two holes IP65 (In accordance with EN 60529)
Installation conditions: Applicable standards:
Ambient operating temperature; -20 to 55ºC EN IEC 60079-0:2018,
Storage temperature: -30 to 70ºC EN 60079-11: 2012, EN 60079-15: 2010
Humidity: 10 to 90%RH at 40ºC (Non-condensing) YH8000-E2 (IECEx)
Power Supply: 24V DC +/-10% Type of protection: Ex nA ic IIC T5 Gc
Power consumption: Max.12 W Enclosure rating:
Safety, EMC, and RoHS conformity standards: IP65 (In accordance with IEC 60529)
Safety conformitystandards: Applicable standards: IEC 60079-0: 2017,
CE, UKCA EN61010-1 IEC 60079-11: 2011, IEC 60079-15: 2010
UL UL61010-1 YH8000-J2 (Japan Ex)
CSA CAN/CSA-C22.2 No.61010-1 Type of protection: Ex nA ic IIC T5 Gc
GB GB30439 Part 1 Enclosure rating:
Installation Altitude: 2000 m or less IP65 (In accordance with IEC 60529)
Installation category: I Applicable standards: JNIOSH-TR-46-1:2020
(Anticipated transient overvoltage 330 V) JNIOSH-TR-46-6:2015
Pollution degree: 2, Indoor/Outdoor use JNIOSH-TR-46-8:2015
EMC conformity standards: YH8000-K2 (Korea Ex)
CE, UKCA EN55011 Class A Group 1 Type of protection: Ex nA ic IIC T5 Gc
EN61326-1 Class A Table 2 (For use in Enclosure rating: IP65 (In accordance with
industrial location) IEC 60529)
RCM EN55011 Class A Group 1 Applicable standards: Notice of Ministry of
KC KN11 Class A Group 1, KN61000-6-2 LaborNo. 2021-22
(Korea Electromagnetic Conformity) Harmonized with IEC60079-
RoHS conformity standards: EN IEC 63000:2018* 0: 2017, IEC 60079-11:
*: For only YH8000-G1, -G2, -S2 2011, IEC 60079-15:2010
Information of the WEEE Directive YH8000-N2 (NEPSI)
This product is purposely designed to be used Type of protection: Ex ec ic IIC T5 Gc
in a large scale fixed installations only and, Enclosure rating: IP65 (In accordance with
therefore, is out of scope of the WEEE Directive. GB/T 4208-2017)
The WEEE Directive does not apply. Applicable standards: GB/T 3836.1-2021,
The WEEE Directive is only valid in the EU and GB/T 3836.3-2021,
UK. GB/T 3836.4-2021
YH8000-R2 (EAC)
Hazardous area classifications: Type of protection: 2Ex nA ic IIC T5 Gc X
Division 2, Zone2: Nonincendive/Type n Enclosure rating: IP65 (In accordance with
YH8000-D2 (FM Approval for US) GOST 14254)
Division system Applicable standards: GOST 31610.0-2014
Type of protection: Nonincendive for Class I, GOST 31610.15-2014
Division 2, Groups A, B, C, D, T5 GOST 31610.11-2014
Enclosure rating: Type 4X YH8000-U2 (INMETRO)
Applicable standards: FM Class 3600: 2018 Type of protection: Ex nA ic IIC T5 Gc
FM Class 3611: 2018 Enclosure rating: IP65
FM Class 3810: 2018 Applicable standards:
NEMA 250: 2003 ABNT NBR IEC 60079-0:2020
Zone system ABNT NBR IEC 60079-11:2013
Type of protection: Versão Corrigida:2017
Class I, Zone 2, AEx nA ic IIC T5 Gc ABNT NBR IEC 60079-15:2019
Enclosure rating: IP65
Applicable standards: ANSI/UL 60079-0:2019,
ANSI/UL 60079-11:2013
ANSI/UL 60079-15:2013
ANSI/UL 121201:2019
ANSI/IEC 60529-2004
YH8000-C2 (FM Approval for Canada)
Type of protection: Ex nA ic IIC T5 Gc
Enclosure rating: IP65, Type 4X

All Rights Reserved. Copyright © 2015, Yokogawa Electric Corporation GS 11Y01D01-01EN Nov. 01, 2023-00
10
● IF8000 Isolation Flanges Note: When using TDLS8000 as CE/UKCA marking
compliance product, the upper limit of the
A process isolation flange protects the TDLS8000 measurement gas pressure in YC8000 is 50kPa in
from the process gas pressure and the heat, dust, gauge pressure.
and corrosive elements of the process gas. A process
isolation flange must be installed in the following ● Calibration Cell
situations.• When the process gas pressure Used for off-line calibrations and validations.
exceeds 500 kPa Appropriate process windows are included on
• When the process temperature is high and the calibration cell.
temperature of the process window area exceeds Optical Path Length: 660 mm
55ºC even when process window purge is performed. Material: 316 SS
• When the process dust level is high and the
adherence of dust or intrusion of corrosive elements Part No. Description Weight
cannot be prevented even when process window K9772XA Calibration Cell with free-standing
frame for O2
purge is performed. K9772XB Calibration Cell with free-standing
The IF8000 isolation flanges can be used for additional frame for O2 LAO
protection in in-situ or bypass installations. K9772XC Calibration Cell with free-standing frame
for ppm H2O in non- hydrocarbon
Note: Must use in conjunction with alignment flanges
K9772XD Calibration Cell with free-standing
Process connections: (see below table) frame for NH3
Heatresistance temperature: 200ºC max K9772XE Calibration Cell with free-standing frame
Measured gas pressure: Max. 1 MPa abs. for ppm H2O in hydrocarbon background
Wetted materials: Sapphire, 316 SS, Monel 400, K9772XF Calibration Cell with free-standing Approx.
FFKM (O-ring) frame for ppm CO 14 kg
K9772XG Calibration Cell with free-standing
Weight; frame for ppm CO LAO
Process Analyzer Weight (Approx.) K9772XH Calibration Cell with free-standing frame for
connection connection 316SS Monel 400 CO (%) + CO2 (%), CO2 (%) Extend. Range
K9772XJ Calibration Cell with free-standing
ANSI Class 150-
5 kg/pc 6 kg/pc frame for HCl
2-RF Flange K9772XL Calibration Cell with free-standing
ANSI Class 300- frame for CO(%), CO2 (%) High Range
7 kg/pc 7 kg/pc
2-RF Flange K9772XM Calibration Cell with free-standing
ANSI Class 150- ANSI Class 150- frame for H2S
8 kg/pc 9 kg/pc
3-RF Flange 2-RF Flange Note: When using TDLS8000 as CE/UKCA marking
ANSI Class 300- compliance product, the upper limit of gas pressure in
11 kg/pc 12 kg/pc
3-RF Flange calibration cell is 50kPa in gauge pressure.
ANSI Class 150-
12 kg/pc 14 kg/pc ● Unit Connection Cable
4-RF Flange
DIN PN16-DN50
7 kg/pc 7 kg/pc
Use for interconnecting the Sensor Control Unit and the
Flange Laser Unit.
DIN PN16-DN80 Construction:
10 kg/pc 11 kg/pc
Flange DIN PN16-DN50 Double-shielded (Overall shield and Individual shields)
JIS 10K-50-FF Flange 4-pair cable
7 kg/pc 7 kg/pc
Flange
JIS 10K-80-FF Part No. Cable length
9 kg/pc 10 kg/pc
Flange K9775XA 5m
Note: When using TDLS8000 as CE/UKCA marking K9775XB 10 m
compliance product, the upper limit of the K9775XC 20 m
measurement gas pressure is 50kPa in gauge K9775XD 30 m
pressure.
Consult with Yokogawa Europe B.V. in the case of K9775XE 40 m
witnessing high pressure in Europe. K9775XF 50 m
K9775XG 60 m
● YC8000 Flow Cell
Note: When cable length is not more than 25m, Belden
Used for extracting sample streams at any location. 1475A may be used as Unit Connection Cable.
Note: Must use in conjunction with alignment flanges (“-FC”)
Gas temperature: 200ºC max
Gas pressure: Max. 1 MPa abs.
Wetted materials: Sapphire, 316 SS, Monel 400,
FFKM (O-ring)
Weight;
Material/Optical 1016 mm 1524 mm
Path Length (40 inch) (60 inch)
Monel 400 Approx. 15 kg Approx. 18 kg
316 SS Approx. 14 kg Approx. 17 kg

All Rights Reserved. Copyright © 2015, Yokogawa Electric Corporation GS 11Y01D01-01EN Nov. 01, 2023-00
11
 MODEL AND CODES
● TDLS8000 Tunable Diode Laser Spectrometer

Model Suffix Code Option Code Description


TDLS8000 ..................................... ....................... Tunable Diode Laser Spectrometer
Type -G1 ....................... General Purpose, cable entry/piping:NPT
-G2 ....................... General Purpose, cable entry:Metric thread, piping:Rc
-GQ ....................... EAC with PA General Purpose, cable entry:Metric thread, piping:Rc
-GR ....................... EAC General Purpose, cable entry:Metric thread, piping:Rc
-D2 ....................... FM (US) Class I Div 2, Zone2, cable entry/piping:NPT
-C2 ....................... FM (Canada) Class I Zone2, cable entry/piping:NPT
-S2 ....................... ATEX Type of protection “n”, cable entry:Metric thread, piping:Rc (*14)
-E2 ....................... IECEx Type of protection “n”, cable entry:Metric thread, piping:Rc
-K2 ....................... Korea Ex Type of protection “n”, cable entry:Metric thread, piping:Rc
-N2 ....................... NEPSI Type of protection “n”, cable entry:Metric thread, piping:Rc
-Q2 ....................... EAC with PA Type of protection “n”, cable entry:Metric thread, piping:Rc
-R2 ....................... EAC Type of protection “n”, cable entry:Metric thread, piping:Rc
-U2 ...................... INMETRO Type of protection “n”, cable entry: Metric thread, piping: Rc
-D1 ...................... FM (US) Class I Div 1, Zone1, cable entry/piping:NPT (*1)
-C1 ...................... FM (Canada) Class I Zone1, cable entry/piping:NPT (*1)
-S1 ....................... ATEX Flameproof ”d”, cable entry:Metric thread, piping:Rc (*1) (*14)
-E1 ....................... IECEx Flameproof “d”, cable entry:Metric thread, piping:Rc (*1)
-K1 ...................... Korea Ex Flameproof “d”, cable entry: Metric thread, piping: Rc (*1)
-J1 ...................... Japan Ex / Zone 1, cable entry:Metric thread, piping:Rc (*1) (*11)
-J2 ...................... Japan Ex / Zone 2, cable entry:Metric thread, piping:Rc (*11)
-N1 ...................... NEPSI Flameproof “d”, cable entry:Metric thread, piping:Rc (*1)
-Q1 ...................... EAC with PA Flameproof “d”, cable entry:Metric thread, piping:Rc (*1)
-R1 ...................... EAC Flameproof “d”, cable entry:Metric thread, piping:Rc (*1)
-U1 ...................... INMETRO Flameproof “d”, cable entry:Metric thread, piping:Rc (*1)
Gas Parameter -X1 ....................... O2 < 600°C, 0-25% (*2)
-X2 ....................... O2 < 1500°C, 0-25% Combustion
-C1 ....................... CO (%) 0-20%/0-50% <500°C
-C2 ....................... CO ppm 0-200ppm/0-10,000ppm <500°C (*3)
-C3 ....................... CO ppm <1500°C Combustion (*3)
-C4 ....................... CO ppm <1500°C or CH4 0-5% Combustion (*3)
-C5 ....................... CO (%) + CO2(%) 0-30%/0-100% <150°C
-A1 ....................... NH3 up to 0-5,000ppm <450°C DeNOX
-S1 ....................... H2S 0-5%/0-100% <100°C (*2)
-D1 ....................... CO2 High Range 0-1%/0-5% <100°C
-D5 ....................... CO2 Extend. Range 0-30/0-50% <150°C
-H1 ....................... H2O ppm non-Hydrocarbon Background (*1)
-H3 ....................... H2O ppm Hydrocarbon Background (*1)
-H4 ....................... H2O 0-10%/0-100% <500°C (*1)
-L1 ....................... HCl 0-50ppm/0-5,000ppm <500°C
Optics Accessory -NN ....................... Without Alignment Flanges (*4)
-LA ....................... Large Aperture Optics, ANSI CLASS150-4-RF (*5) (*6)
-U2 ....................... ANSI CLASS150-2-RF(Eq.) Alignment Flange, pipng: NPT
-U3 ....................... ANSI CLASS150-3-RF(Eq.) Alignment Flange, pipng: NPT
-U4 ....................... ANSI CLASS150-4-RF(Eq.) Alignment Flange, pipng: NPT
-D5 ....................... DIN PN16-DN50-D(Eq.) Alignment Flange, pipng: Rc
-D8 ....................... DIN PN16-DN80-D(Eq.) Alignment Flange, pipng: Rc
-J5 ....................... JIS 10K-50-FF(Eq.) Alignment Flange, pipng: Rc
-J8 ....................... JIS 10K-80-FF(Eq.) Alignment Flange, pipng: Rc
-FC ....................... Flow Cell Alignment Flange (*6)
I/O Interface -A1 ....................... Analog with HART+Modbus Ethernet
SI Unit -N ....................... SI Unit or non SI Unit (*7)
-J ....................... Only SI Unit
— -N ....................... Always -N

All Rights Reserved. Copyright © 2015, Yokogawa Electric Corporation GS 11Y01D01-01EN Nov. 01, 2023-00
12
Option /D Diverging Beam without LAO (*8)
/RX Reference Cell for O2 (*9)
/RC Reference Cell for CO (*10)
/SCT Stainless Steel Tag Plate
/JA1 Cable gland for Japan Ex “-J1” (Cable O.D. 8-12mm, G1/2) 1pc, for local HMI
/JB3 Cable gland for Japan Ex “-J1” (Cable O.D. 10-16mm, G3/4) 3 pcs
/JB4 Cable gland for Japan Ex “-J1” (Cable O.D. 10-16mm, G3/4) 4 pcs
/JC1 Cable gland for Japan Ex “-J2” (Cable O.D. 6-9.5mm, M20) 1pc, for local HMI
/JD1 Cable gland for Japan Ex “-J2” (Cable O.D. 8.5-13.4mm, M20) 1pc, for local HMI
/JE3 Cable gland for Japan Ex “-J2” (Cable O.D. 9.5-15.4mm, M25) 3 pcs
/JE4 Cable gland for Japan Ex “-J2” (Cable O.D. 9.5-15.4mm, M25) 4 pcs
/P2 130<P<400kPa (abs.) (*12)
/P3 P>400kPa (abs.) (*12)
/WCD DNV Type Approval (*13)

*1: Type “-D1”, “-C1”, “- S1”, “-E1”, “-K1”,“-J1”, “-N1”,“-Q1”, “-R1”, “-U1” cannot be selected with “-H1” “-H3”, or “-H4”.
*2: When the process gas pressure is out of 90 to 130 kPa (abs.) or the process gas contains CO2 ≥ 40 % or H2 ≥ 20 % as
coexisting gas components, please contact YOKOGAWA.
*3: When CO or CH4 ingredient coexist, please contact YOKOGAWA.
*4: When “-NN” is selected, Zone2/Div2/Type of protection “n”, FM (Canada) Zone1 is not available.
*5: For applications whose optical path length is 6 m or longer, select the “-LA”. A condensing lens unit (LAO unit) is added to
the SCU side.
“-LA” can be selected when Oxygen or CO (-C2, -C3, -C4) analyzer is selected.
“-LA” can be selected with Zone 1/Div.1/Flameproof “d” when Gas Parameter “-X2”, “-C3”, “-C4” is selected.
*6: When FM (US) or FM (Canada) is specified, the connecting port for window purge is 1/4NPT.
When ATEX, IECEx, Korea Ex, NEPSI, EAC or Japan Ex is specified, the connecting port for window purge is Rc1/4.
*7: Available only to an end user located outside of Japan.
*8: The Option “/D” can be selected when Large Aperture Optics “-LA” of the Optic Accessory is not specified and Oxygen or
CO (-C2, -C3, -C4) analyzer is selected.
*9: The Option “/RX” can be used when Oxygen analyzer is selected. When both “-X2” of the Gas Parameter and “-LA” of the
Optics Accessory are selected, “/RX”must be specified.
*10: The Option “/RC” can be used when CO analyzer is selected. When both “-C3” or “-C4”of the Gas Parameter is selected,
“/RC” must be specified.
*11: For Japan Ex model (TDLS8000-J1, TDLS8000-J2), specified cable glands shall be attached to each cable entry for wiring.
Select one cable gland out of two types: (/JB3 or /JB4 for “-J1”, /JE3 or /JE4 for “-J2”). If you need, specify (/JA1 for “-J1”, /
JC1 or /JD1 for “-J2”) as well. For detailed information, refer to Japanese General Specifications.
The Option “/JA1”, “/JB3” and “/JB4” can be used only when Japan Ex/Zone 1 model (TDLS8000-J1) is selected.
The Option “/JC1”, “/JD1”, “/JE3” and “/JE4” can be used only when Japan Ex/Zone 2 (TDLS8000-J2) model is selected.
If “/JA1”, “/JB3”, “/JB4”, “/JC1”, “/JD1”, “/JE3” or “/JE4” is necessary for other model, please contact Yokogawa.
*12: P is the process gas pressure. The option “/P2” and “/P3” can be selected with the gas parameter “-X1”. When the gas
parameter is not “-X1”, please contact YOKOGAWA.
*13: TDLS8000-G2-aa-bb-A1-c-N (Option)
-aa: -X1, -X2, -D1, -D5
-bb: -D5, -D8, -J5, -J8
-c: -N, -J
(Option): Only /D, /RX, /SCT can be selected.
A noise filter must be prepared. Refer to “ WIRING” on page 22.
Cable glands (M25, 3 pcs, Applicable cable diameter 9-17mm) are attached.
*14: This model is available for UKCA.

All Rights Reserved. Copyright © 2015, Yokogawa Electric Corporation GS 11Y01D01-01EN Nov. 01, 2023-00
13
● YH8000 HMI Unit
Model Suffix Code Option Code Description
YH8000 ...................... ....................... HMI Unit
Type -G1 ....................... General Purpose, NPT thread for cable entry
-G2 ....................... General Purpose, Metric thread for cable entry
-GR ....................... EAC General Purpose, Metric thread for cable entry
-D2 ....................... FM (US) Class I Div 2, Zone2, NPT thread for cable entry
-C2 ....................... FM (Canada) Class I Zone2, NPT thread for cable entry
-S2 ....................... ATEX Type of protection “n”, Metric thread for cable entry (*4)
-E2 ....................... IECEx Type of protection “n”, Metric thread for cable entry
-J2 ....................... Japan Ex/Zone 2, Metric thread for cable entry (*2)
-K2 ....................... Korea Ex Type of protection “n”, Metric thread for cable entry
-N2 ....................... NEPSI Increased safety “ec”, Metric thread for cable entry
-R2 ....................... EAC Type of protection “n”, Metric thread for cable entry
-U2 ....................... INMETRO Type of protection “n”, Metric thread for cable entry
Language -E ....................... English and 9 languages (*1)
— -N ....................... Always -N
Option /M Mounting kit for TDLS8000 series (*3)
/P Pipe mount
/W Wall mount
/S Sun Shield
/C Local HMI connection cable: 3m
/SCT Stainless Steel Tag Plate
/JA1 Cable gland for Japan Ex (Cable O.D. 8-12mm, G1/2), 1 pc(*2)
/JA2 Cable gland for Japan Ex (Cable O.D. 8-12mm, G1/2), 2 pc(*2)
*1: These languages are message languages on the display.
One analyzer has English and 9 languages.
All languages are as follows; English, German, French, Spanish, Portuguese, Russian, Hungarian, Korean, Chinese and Japanese.
*2: For Japan Ex/Zone 2 certified model (YH8000-J2), specified cable glands shall be attached to each cable entry for wiring.
Select the Option “/JA1” or “/JA2”.
For detailed information, refer to Japanese General Specifications (GS 11Y01D01-01JA).
The Option “/JA1” and “/JA2” can be used only when Japan Ex/Zone 2 certified model (YH8000-J2) is selected. If “/JA1” or
“/JA2” is necessary for other model, please contact Yokogawa.
*3: /M cannot be selected with TDLS8000 Type “-D1”, “-C1”, “-S1”, “-E1”, “-K1”, “-J1”, “-N1”, “-Q1”, “-R1”, “-U1”.
*4: This model is available for UKCA.

All Rights Reserved. Copyright © 2015, Yokogawa Electric Corporation GS 11Y01D01-01EN Nov. 01, 2023-00
14
● IF8000 Isolation Flanges
Model Suffix Code Option Code Description
IF8000 .................................................. ....................... Isolation Flange for TDLS8000 (2pcs/unit) (*1)
Process -21 ....................... ANSI CLASS150-2-RF(Eq.)
Connection -23 ....................... ANSI CLASS300-2-RF(Eq.)
(*2) -31 ....................... ANSI CLASS150-3-RF(Eq.)
-33 ....................... ANSI CLASS300-3-RF(Eq.)
-41 ....................... ANSI CLASS150-4-RF(Eq.)
-50 ....................... DIN PN16-DN50-D(Eq.)
-80 ....................... DIN PN16-DN80-D(Eq.)
-J5 ....................... JIS 10K-50-FF(Eq.)
-J8 ....................... JIS 10K-80-FF(Eq.)
Analyzer Connection -21 ....................... ANSI CLASS150-2-RF(Eq.)
(*3) -50 ....................... DIN PN16-DN50-D(Eq.)
Material -MN ....................... Monel 400
-SS ....................... 316/316L SS
Window Type (*4) -12 ....................... O2 (-X1, -X2)
-13 ....................... H2O (-H1)
-14 ....................... NH3 (-A1)
-15 ....................... H2O (-H3)
-16 ....................... CO (-C2, -C3, -C4)
-17 ....................... CO+CO2 (-C5), CO2 (-D5)
-18 ....................... HCl (-L1), H2O (-H4)(*5)
-20 ....................... CO (-C1), CO2 (-D1), H2S (-S1)
— -N ....................... Always -N

*1: IF8000 is delivered with two sets (for LU and SCU).


*2: When ANSI flange of the Process Connection is selected, the “-21” of Analyzer Connection must be specified.
When DIN or JIS of the Process Connection is selected, the “-50” of Analyzer Connection must be specified.
*3: The Analyzer Connection must be selected according to the flange size of TDLS8000.
*4: Select according to the TDLS8000 Gas Parameter.
*5: When TDLS8000 H20 (%) analyzer: (-H4) manufactured before 2019 is combined, “-20” (-C1, -D1, -S1) must be specified.

● YC8000 Flow Cell


Model Suffix Code Option Code Description
YC8000 ........................................................................ ....................... Flow Cell for TDLS8000
Flow Cell Type -EN ....................... Enhanced
Optical Path Length -40 ....................... Forty Inches
-60 ....................... Sixty Inches
Material -MN ....................... Monel 400
-SS ....................... 316/316L SS
Port Configuration -3 ....................... 3 ports
Window Type (*2) -XX ....................... O2 (-X1, -X2)
-H3 ....................... H2O (-H3)
-HH ....................... H2O (-H1)
-NH ....................... NH3 (-A1)
-CC ....................... CO (-C2, -C3, -C4)
-C2 ....................... CO+CO2 (-C5), CO2 (-D5)
-HC ....................... HCl (-L1), H2O (-H4) (*1)
-MC ....................... CO (-C1), CO2 (-D1), H2S (-S1)
Inside Wall Treatment -NN ....................... No treatment (cleaned)
-EP ....................... Electro-polish
— -N ....................... Always -N

*1: When TDLS8000 H20 (%) analyzer: (-H4) manufactured before 2019 is combined, “-MC” (-C1, -D1, -S1) must be specified.
*2: Select according to the TDLS8000 Gas Parameter.

All Rights Reserved. Copyright © 2015, Yokogawa Electric Corporation GS 11Y01D01-01EN Nov. 01, 2023-00
15
 EXTERNAL DIMENSIONS
For the external dimensions of Japan Ex model (TDLS8000-J1, TDLS8000-J2, YH8000-J2), see Japanese General
Specifications (GS 11Y01D01-01JA).

TDLS8000 with Alignment Flange


● LU
Unit: mm
332
17 Alignment flange *1
20

Measured
198
gas

Purge port (OUT) x2


200 Flow restrictor *2 1/4NPT or Rc1/4

Ø180
33

*1: The alignment flange varies according to specifications.


Other flanges may be added.
*2: The flow restrictors are attached in the case of
type -D1, -C1, -S1, -E1, -K1, -J1, -N1, -Q1, -R1or -U1.

SCU cable gland


3/4NPT or M25x1.5

237
33
Purge port (IN)
1/4NPT or Rc1/4
80

34

All Rights Reserved. Copyright © 2015, Yokogawa Electric Corporation GS 11Y01D01-01EN Nov. 01, 2023-00
16
● SCU

332 Unit: mm

Alignment 17
flange *1 20

Measured
198
gas

62
Purge port (OUT) x2 Flow restrictor *2
1/4NPT or Rc1/4 196
LU cable gland
Ø180
3/4NPT or M25x1.5
65

*1: The alignment flange varies according to specifications. For I/O signal
Other flanges may be added. 3/4NPT or M25x1.5
*2: The flow restrictors are attached in the case of
type -D1, -C1, -S1, -E1, -K1, -J1, -N1, -Q1, -R1 or -U1.
For power supply
3/4NPT or M25x1.5

For YH8000
1/2NPT or M20x1.5
237
33
Purge port (IN)
1/4NPT or Rc1/4
80

34

● Maintenance space
Unit: mm

150

600
150 150

250

All Rights Reserved. Copyright © 2015, Yokogawa Electric Corporation GS 11Y01D01-01EN Nov. 01, 2023-00
17
● Alignment Flange
A (variable) Unit: mm
Purge port (IN) x2
1/4NPT or Rc1/4 t Q-h
ØC

Ø61.7

ØD

TDLS8000 side Process side

Optics Accessory code Hole QTY Hole Hole P.C.D Thickness Outside dia. Distance
Purge port
(flange) Q h C t D A
-U2 ANSI CLASS150-2-RF(Eq.) 4 19 120.7 19.5 150 87 1/4NPT
-U3 ANSI CLASS150-3-RF(Eq.) 4 19 152.4 24.3 190 92 1/4NPT
-U4 ANSI CLASS150-4-RF(Eq.) 8 19 190.5 23.9 228.6 92 1/4NPT
-D5 DIN PN16-DN50-D(Eq.) 4 18 125 18 165 86 Rc1/4
-D8 DIN PN16-DN80-D(Eq.) 8 18 160 20 200 88 Rc1/4
-J5 JIS 10K-50-FF(Eq.) 4 19 120 16 155 84 Rc1/4
-J8 JIS 10K-80-FF(Eq.) 8 19 150 18 185 86 Rc1/4

● LAO (Large Aperture Optics); Optics Accessory code “-LA”


This accessory is only for SCU side. For LU side, the Alignment flange ANSI CLASS150-4-RF (Eq.) will be mounted.
When piping is Rc1/4, a conversion adapter will be attached on the Alignment flange of the LU side.

23.9 Unit: mm
Purge port (IN) x2
1/4NPT or
Ø108.2 Rc1/4 (with adapter)

Ø229

55 189 (Variable)
Ø190.5

Process side TDLS8000 side

8-Ø19 holes

Instalation for process side

All Rights Reserved. Copyright © 2015, Yokogawa Electric Corporation GS 11Y01D01-01EN Nov. 01, 2023-00
18
■ YH8000 HMI Unit

Cable entry 2 (for Modbus) Unit: mm


261 75
1/2NPT or M20x1.5

204 65 75

87.5 4 - M6 depth 13
Earth terminal Cable entry 1 (for TDLS8000 series)
1/2NPT or M20x1.5

Mounting kit for TDLS8000 series (Option code: /M)

261 185 Unit: mm

440

(198)

Front mounting

302

337

(198)

(200)
Right mounting

Available for left mounting

All Rights Reserved. Copyright © 2015, Yokogawa Electric Corporation GS 11Y01D01-01EN Nov. 01, 2023-00
19
Pipe mount (Option code: /P)
261 108.3 Unit: mm
138
54.3 46.3
123

Bracket
for pipe mount
102

204 65 110

2B pipe
87.5 Vertical or horizontal mounting

Sun Shield (Option code: /S)


Unit: mm
197
318 31 46.3
Stud for
sun shield

Bracket
for pipe mount

212.5

2B pipe
178 Vertical or horizontal mounting

Wall mount (Option code: /W)

266 Bracket for wall mount Unit: mm


10 246 105.4 246±0.5
10

226 206 206


±0.5

4 - Ø6.0 to 7.2 holes


or M6

Installation for wall


4 - Ø7.2 holes

*: The wall construction for mounting has to be designed for 4 times the weight of the YH8000.
Bracket for wall mount can be placed in lengthwise

All Rights Reserved. Copyright © 2015, Yokogawa Electric Corporation GS 11Y01D01-01EN Nov. 01, 2023-00
20
Sun Shield (Option code: /S)
318
196 Unit: mm
246 Bracket for wall mount
10 206 30
206±0.5
10

266 246
246
±0.5

4 - Ø6.0 to 7.2 holes


or M6

Installation for wall


4 - Ø7.2 holes

When the sun shield is mounted, the bracket for wall have to be placed in widthwise.

■ IF8000 Isolation Flanges

Unit: mm
Nut
5/8UNC, 3/4UNC
or M16 Q-h ØC

Ø38

ØD

t
Purge port (IN) x2 Instalation for process side
L
1/4NPT or Rc1/4
TDLS8000 side Process side

Process Connection code Analyzer Connection Hole QTY Hole Hole P.C.D Thickness Outside dia. Bolt length Purge
Nut
(flange) code (flange) Q h C t D L port
-21 ANSI CLASS150-2-RF(Eq.) 4 19 120.7 39.6 150 127
-23 ANSI CLASS300-2-RF(Eq.) ANSI 8 19 5/8UNC 127 39.6 165 137
-31 ANSI CLASS150-3-RF(Eq.) -21 CLASS150-2- 4 19 152.4 39.6 190 137 1/4NPT
-33 ANSI CLASS300-3-RF(Eq.) RF(Eq.) 8 22 3/4UNC 168.3 39.6 210 146
-41 ANSI CLASS150-4-RF(Eq.) 8 19 5/8UNC 190.5 39.1 228.6 137
-50 DIN PN16-DN50-D(Eq.) 4 18 125 41.6 165 137
-80 DIN PN16-DN80-D(Eq.) DIN PN16- 8 18 160 41.6 200 137
-50 M16 Rc1/4
-J5 JIS 10K-50-FF(Eq.) DN50-D(Eq.) 4 19 120 40.6 165 139
-J8 JIS 10K-80-FF(Eq.) 8 19 150 40.6 185 139

All Rights Reserved. Copyright © 2015, Yokogawa Electric Corporation GS 11Y01D01-01EN Nov. 01, 2023-00
21
■ YC8000 Flow Cell
TDLS8000 have to be assigned the dedicated Alignment flange (Optic Accessory: -FC).
When piping is Rc1/4, a conversion adopter will be attached on the Alignment flange.

1053 (Optical path length: -40) or 1561 (Optical path length: -60) Unit: mm

Pipe size: 1-1/2 Sch80


Ø152.4

Sample inlet
(for 1/4” pipe) Sample outlet
86 (vaeiable) 35
(for 1/4” pipe) Ø152.4
Gas temp. or Flow cell aligenment
pressure measurement port flange
(for 1/4” pipe) (TDLS8000
Optics accessory
code “-FC”)

■ Calibration Cell
Part number: K
 9772XA, K9772XB, K9772XC, K9772XD, K9772XE, K9772XF, K9772XG, K9772XH, K9772XJ,
K9772XL, K9772XM

Approx. 690 Unit: mm

Sample port x2 (IN, OUT) 1/4NPT Ø152.4

Pipe size: 1-1/2 Sch80

Approx.
410

Approx. 820 210

■ Unit Connection Cable


Part number: K9775XA, K9775XB, K9775XC, K9775XD, K9775XE, K9775XF, K9775XG

Unit: mm
Ø13.5
L

L = 5, 10, 20, 30, 40, 50, 60 m

All Rights Reserved. Copyright © 2015, Yokogawa Electric Corporation GS 11Y01D01-01EN Nov. 01, 2023-00
22
 WIRING
Wiring Laser Unit and Sensor Control Unit

Laser Unit (LU) Sensor Control Unit (SCU)


Ethernet port for
YH8000 or DCS

Terminal B

Terminal A

Terminal C

Earth for shield wire Earth for shield wire

Earth terminal Earth terminal


Magnified Terminal A Magnified Terminal B
LC MS-1 MS-2 VO AO-1 AO-2 AI-1 AI-2 DI-1 DI-2 DO FAULT
+ - + - + - + - + - + - + - + - + - + - NC COM NO NC COM

Isolated 4-20mA Digital Input Digital


4-20mA Input for Output for
Output Pressure FAULT
With Isolated transmitter 4-20mA Digital
HART 4-20mA Output for
Input for
Connect to shield wire terminal programmable
Output Temperature
DO
(Both side of cable) Magnified Terminal C transmitter
LC MS-1 MS-2 VO SV-1 SV-2 POWER VO (HMI)
+ - + - + - + - + - + - + - + + - -

Solenoid Power
Valve Supply
Control for 24V DC
Auto Cal Solenoid 24V DC Output for
Valve YH8000 Power
Control for
Auto Cal

● Installation of Noise Filter for DNV Type Approval model (/WCD)


Install a noise filter on the power line. Following is a recommendation noise filter.
Manufacturer: TDK-Lambda
Model: RSEN-2003
Attenuation frequency characteristics (Reference)

All Rights Reserved. Copyright © 2015, Yokogawa Electric Corporation GS 11Y01D01-01EN Nov. 01, 2023-00
23
Wiring the YH8000 HMI UNIT

Ethernet port
for DCS

Ethernet port

Port1 Port2
for TDLS8000 Series

Connection for power

Earth for shield wire

Local HMI configuration


Port2

Modbus/TCP communication with DCS


Port1

Ethernet communication with TDLS8000 Series

P -
o -
w 24V DC power from TDLS8000 Series
e +
r +

Connect to shield wire terminal

• Connection cable between TDLS8000 Series and YH8000 must be use special cable which can be specified option code
“/C.”
• Maximum cable length between TDLS8000 Series and YH8000 is 3m.
• Maximum cable length between YH8000 and DCS is 100m.
Remote HMI configuration
Port2

Ethernet communication with TDLS8000 Series


via switching HUB
Port1

P -
o -
w 24V DC power
e +
r +

Connect to shield wire terminal

• Maximum cable length between YH8000 and Switching HUB is 100m.

All Rights Reserved. Copyright © 2015, Yokogawa Electric Corporation GS 11Y01D01-01EN Nov. 01, 2023-00
24
TDLS8000 Tunable DiodeLase Gas Analyzer Inquiry Form
Thank you for your inquiry about our TDLS8000 Tunable Diode Laser Gas Analyzer. Please make inquiries by placing
checkmarks in the appropriate boxes and filling in the blanks. (The items with check mark and descriptions previously
filled on the underlines are fixed requirements.)

1. General Information
Company :
Address :
Contact Person :
Email :
Telephone :
Fax :
Requested delivery date (day/month/year) :
Plant name :
Brief Description of application :

2. Installation Details (check one-see drawing)


 Cross Stack/Pipe. For measurement across the process.
Path length
Process Connection
 Bypass Leg. Measurement across bypass leg located at process measurement point.
Path length
Process Connection
 Extractive. Sample is extracted and transported (by others) to analyzer.

3. Analyzer Options:
 YH8000 HMI Unit  IF8000 Isolation Flanges  YC8000 Flow Cell
 Calibration Cell  Unit Connection Cable
Cable length from Analyzer Unit to HMI Unit (specify units) :
Area Classification:
Ambient Temperature (Min-Max.) Specify units

4. Process Wetted Materials


Must Use
Must Not Use

5. Stream Composition (1 sheet per stream analyzed)


Component Concentrations Units Measured Range
Name Min. Typ. Max. ppm(v)/vol% Yes/No If Measured

All Rights Reserved. Copyright © 2015, Yokogawa Electric Corporation GS 11Y01D01-01EN Nov. 01, 2023-00
25
6. Physical Properties

Units Min. Typ. Max.


Temperature
Pressure
Dew Point
Water Vapor
Flow
Velocity
Particulate Concentration

Installation location:  Indoor  Outdoor


Ambient temperature: to ºC

7. General Application & Installation Notes/Comments:

All Rights Reserved. Copyright © 2015, Yokogawa Electric Corporation GS 11Y01D01-01EN Nov. 01, 2023-00
Subject to change without notice.