DESCRIPTION
The next generation E-Series G2® Ultrasonic meter uses solid-state
technology in a compact, tamper protected, weatherproof and |
UV-resistant housing, suitable for residential applications.
Electronic metering provides information—such as rate of flow
and status and alarm indication—and data not typically available
through traditional, mechanical meters and registers. Electronic
metering minimizes measurement errors due to sand, suspended
particles and pressure fluctuations.
CONSTRUCTION
The E-Series Ultrasonic meter features lead-free bronze alloy meter housing, ultrasonic transducers, a meter-control circuit board with
associated wiring, LCD, and battery. Wetted elements are limited to the pressure vessel and transducers. The electronic components are
housed and fully potted within a molded, engineered polymer enclosure, which is attached to the meter housing. The transducers extend
through the housing and are sealed by O-rings, enabling turbulence-free water flow through the tube. The open flow tube design prevents
obstruction of flow to reduce pressure loss and provide long-term accuracy.
METER INSTALLATION
For long-term performance the meter is weatherproof, UV-resistant, fully submersible and can be installed using horizontal or vertical
piping. The registration electronics and battery are encapsulated to withstand harsh environments and protect the electronics in flooded or
submerged pit applications. The meter will not measure flow when an “empty pipe“ condition is experienced.
NOTE: An empty pipe is defined as a condition that occurs when the flow sensors are not fully submerged.
The meter is available with an in-line connector for easy installation and connection to ORION endpoints. It is also available with a flying
lead for field splice connection.
SPECIFICATIONS
E-Series G2 Ultrasonic Meter Size 5/8 x 3/4 in.
Normal Test Flow Limits 0.08…30 gpm (0.02…6.8 m3/hr)
Minimum Test Flow Limits 0.04 gpm (0.01 m3/hr)
Safe Maximum Operating Condition (SMOC) 30 gpm (6.8 m3/hr)
Typical Pressure Loss 2.6 psi @ 15 gpm (0.18 bar @ 3.4 m3/hr)
In the normal temperature range of 45…122 °F (7…50 °C), new meter consumption
measurement is accurate to:
Operating Performance
• 100% ±1.5% over the normal test flow limits
• 100% ±3.0% for the minimum test flow limits
Storage Temperature – 40…140° F (– 40…60° C)
Maximum Ambient Storage
150° F (66° C)
(Storage for One Hour)
Measured Fluid Temperature Range 34…140° F (1…60° C)
Humidity 0…100% condensing; meter is capable of operating in fully submerged environments
Maximum Working Pressure of
175 psi (12 bar)
Meter Housing
Maximum Operating Pressure of
150 psi (10 bar)
Pressure Sensor
Pressure Sensor Accuracy ±2% of full scale pressure, up to 150 psi (10 bar)
Register Type Straight reading, permanently sealed electronic LCD; digits are 0.28 in. (7 mm) high
• Total consumption (nine digits)
• Unit of measure (factory programmed for gallons, cubic feet and cubic meters)
• Rate of flow
• Pressure (Optional: for meters ordered with integrated pressure sensor)
Register Display
• Temperature
• Alarm and operating mode
• Firmware version
• Alarm indicators
• Gallons: 0.01
Totalization Display Resolution • Cubic feet: 0.001
• Cubic meters: 0.0001
3.6-volt lithium thionyl chloride; battery is fully encapsulated within the register
Battery
housing and is not replaceable; 20-year battery life
MATERIALS
Meter Housing Lead-free bronze alloy
Measuring Section Ultrasonic sensors located in the flow tube
Register Housing and Lid Engineered polymer
PHYSICAL DIMENSIONS
E-Series G2 Ultrasonic Meter Size 5/8 x 3/4 in.
Size Designation X Lay Length 5/8 × 3/4 × 7-1/2 in. (16 × 19 × 191 mm)
Bore Size 3/4 in. (19 mm)
Coupling Nut & Spud Thread (NPT) 1 in. (25 mm) × 11-1/2 NPSM
Service Pipe Thread 3/4 in. (19 mm)
Weight (without AMR) 2.7 lb (1.23 kg)
See illustration below for Measurement Designations
Length (A) 7.49 in. (190 mm)
Height (B ) 2.99 in. (76 mm)
Height (C) 3.66 in. (93 mm)
Length (D) 3.74 in. (95 mm)
Width (E) 4.82 in. (122 mm)
Measurement Designations
.005
B
C
12
8
PRESSURE LOSS (PSI)
0
0 5 10 15 20 25 30
FLOW RATE [GPM]
ACCURACY CHART
Charts represent typical meter performance. Rate of flow in gallons per minute (gpm).