Avtron K575A

Resistive Permanent Load Bank - 500 to 1250 KW

Testing Your Emergency Standby The Avtron Model K575A Load Bank is designed for
Generator with a Load Bank Means outdoor installation for testing AC generating systems.
Reliability When it Matters Most.
The Avtron K575A load bank can be utilized independently or as a modular building block for
larger systems to meet a variety of requirements. This load bank series incorporates the latest
state-of-the-art load bank design features and manufacturing techniques to provide reliable
Key Features operation and extended service life. The K575A load bank is used for testing AC generating
systems in production line applications and is also available mounted on a trailer to provide
• Outdoor Installation mobile high power testing.
• Temperature Controlled Weather- The contactors are enclosed in a thermostatically controlled heated compartment to help
proof Contactor Compartment prevent problems caused by condensation. This compartment is sealed with a rubber gasket
to protect the components from environmental contamination.
• No Cool Down Period
Required The K575A load bank contains resistive elements and a blower motor in a rigid structure of
formed heavy gauge steel. Designed for outdoor installation, the K575A utilizes a screened
• Optional DC Designs air inlet and exhaust louver to protect the motor and resistive assemblies.
• Standard 19" Remote Control Carefully engineered and manufactured resistive elements are designed to operate at a
Panel with Optional Enclosure fraction of their maximum temperature rating. This ensures more stable loading, extends
element operating life and eliminates the need for a cool down period after each loading
• Fully Supported Load session.
Elements

Superior Avtron quality combined with


simple operation and maintenance will
provide years of trouble free service.

Avtron’s extensive line of Load Bank and


Industrial Resis­tor Products are solid
performers used throughout the world.

For total technical support or additional


information, please contact Avtron at
(216) 573-7600 or LBsales@Emerson.com.

Quality System Certified to ISO 9001

K575A 750KW
Permanent Resistive
Avtron Load Bank.
Avtron K575A
Resistive Permanent Load Bank - 500 to 1250 KW

Specifications subject to change without notice.


Construction Load Capacity Ratings: (3 phase, 60 Hz)
Heavy gauge steel structure provides a rigid en- Available Load Step Resolution: 5 or 50 KW
closure. Removable panels with rubber gaskets
Rated KW 240/480 VAC 480 VAC Load Bank Weight (approx.)
protect contactors from the weather. Screened
air inlet and louvered exhaust openings pro- 500  
1800 lbs. [816.5 kg]
tect the load bank from foreign objects and 600  
weather. Horizontal airflow provides maximum Options
750  
protection and reliability in an outdoor environ- • SIGMA™ Network Control
ment. Upright construction minimizes foot- 1000  
print. Permanent base is designed for mounting 1250   • ADMS™ Digital Metering (V, A, KW, Hz)
on floor, roof, or cement pad and is equipped with Communicator EXT™ Data Logging
with built-in forklift channels. NOTE Other Voltages and DC designs available. Software
Consult factory.
Resistor Elements • Meter and Control Panel Enclosure
The resistive elements are designed by Avtron • 230/460, 208, 230, or 575 V Blower
and manufactured of a corrosion resistant
• Control Transformer for 208, 230, 460,
chromium alloy wire. Resistive elements are
230/460, or 575 Volt Power
fully supported over their entire length for
improved operating life.
75.25
Control Power [1911.00]

The K575A requires control power of 120 36.00


[914.40]
volts, single phase, 60 Hz, 15 amps (control ALLOW 36” MIN
transformer optional). CLEARANCE FOR
MAINTENANCE

Cooling 50.50
[1283.00]
The resistive elements are air cooled by a self-
contained 5 HP (750 KW) or 10 HP (1000 and GUARD
SCREEN
1250 KW) blower required 460 volts, 3 phase,
60 Hz power. No additional cooling period is
required when load is removed from the ele-
END VIEW
ments. Other blower voltages are available. AIR INTAKE

Controls
Contactors are protected in a thermostati-
84.00 5.69
[2133.00] [144.00]

cally controlled, heated compartment. The CUSTOMER


REMOVABLE
ACCESS
19" rack-mounted control panel for indoor CONTROL
CONNECTIONS
PANELS
BOTH SIDES
use includes a POWER ON-OFF switch, a
AIR OUT
POWER ON light, BLOWER ON-OFF push but-
AIR IN
SCREENED SCREENED
ton with a BLOWER FAILURE light, OVERTEM- A
B
PERATURE and UTILITY LOSS light, MASTER C

LOAD ON-OFF switch, and load step switches. 25.82 LOUVERED


A voltage selector switch is provided for dual [656.00] PANEL

voltage load banks.


Protection 21.88
The K575A differential pressure air switch is [555.00] LOAD INPUT CONNECTIONS

electrically interlocked to remove the load if All dimensions are in inches [millimeters].
the air flow is not sufficient to produce proper
cooling. Overtemperature protection and
branch circuit fusing is also provided.
Emerson. Consider it Solved and Emerson Network Power are trademarks of Emerson Electric Co.
Emerson Network Power or one of its affiliated companies. All the other marks are the property of their respective owners.
Avtron • 6255 Halle Drive, Cleveland, Ohio 44125, U.S.A. Communicator EXT™ is a trademark of Electro Industries/GaugeTech. ADMS™ is a trademark of Avtron.
216-573-7600 • FAX: 216-573-5953 • LBsales@Emerson.com SIGMA™ is a trademark of NJ Froment & Co. Ltd. Specifications subject to change without notice.

EmersonNetworkPower.com/loadbank ©2015 Emerson Network Power Bulletin 416• Rev. D