K575a Avtron
K575a Avtron
K575a Avtron
Testing Your Emergency Standby The Avtron Model K575A Load Bank is designed for
Generator with a Load Bank Means outdoor installation for testing AC generating systems.
Reliability When it Matters Most.
The Avtron K575A load bank can be utilized independently or as a modular building block for
larger systems to meet a variety of requirements. This load bank series incorporates the latest
state-of-the-art load bank design features and manufacturing techniques to provide reliable
Key Features operation and extended service life. The K575A load bank is used for testing AC generating
systems in production line applications and is also available mounted on a trailer to provide
• Outdoor Installation mobile high power testing.
• Temperature Controlled Weather- The contactors are enclosed in a thermostatically controlled heated compartment to help
proof Contactor Compartment prevent problems caused by condensation. This compartment is sealed with a rubber gasket
to protect the components from environmental contamination.
• No Cool Down Period
Required The K575A load bank contains resistive elements and a blower motor in a rigid structure of
formed heavy gauge steel. Designed for outdoor installation, the K575A utilizes a screened
• Optional DC Designs air inlet and exhaust louver to protect the motor and resistive assemblies.
• Standard 19" Remote Control Carefully engineered and manufactured resistive elements are designed to operate at a
Panel with Optional Enclosure fraction of their maximum temperature rating. This ensures more stable loading, extends
element operating life and eliminates the need for a cool down period after each loading
• Fully Supported Load session.
Elements
K575A 750KW
Permanent Resistive
Avtron Load Bank.
Avtron K575A
Resistive Permanent Load Bank - 500 to 1250 KW
Cooling 50.50
[1283.00]
The resistive elements are air cooled by a self-
contained 5 HP (750 KW) or 10 HP (1000 and GUARD
SCREEN
1250 KW) blower required 460 volts, 3 phase,
60 Hz power. No additional cooling period is
required when load is removed from the ele-
END VIEW
ments. Other blower voltages are available. AIR INTAKE
Controls
Contactors are protected in a thermostati-
84.00 5.69
[2133.00] [144.00]
electrically interlocked to remove the load if All dimensions are in inches [millimeters].
the air flow is not sufficient to produce proper
cooling. Overtemperature protection and
branch circuit fusing is also provided.
Emerson. Consider it Solved and Emerson Network Power are trademarks of Emerson Electric Co.
Emerson Network Power or one of its affiliated companies. All the other marks are the property of their respective owners.
Avtron • 6255 Halle Drive, Cleveland, Ohio 44125, U.S.A. Communicator EXT™ is a trademark of Electro Industries/GaugeTech. ADMS™ is a trademark of Avtron.
216-573-7600 • FAX: 216-573-5953 • LBsales@Emerson.com SIGMA™ is a trademark of NJ Froment & Co. Ltd. Specifications subject to change without notice.