Mot Nnom [rpm] Nominal asynchronous rpm specified by motor name plate
Parameter Description
INS SPE [0.01m/s] Speed at inspection run.
Example: for inspection run with 0,5m/s set INS SPE = 50
NOM SPE [0.01m/s] Nominal speed at constant run (normally set to "Con Spe").
Can be used to reduce nominal speed for test purposes.
Example: to run a 1,6m/s -unit at half speed set NOM SPE = 80
SHR SPE [0.01m/s] --- not used for this SW version ---
REL SPE [0.01m/s] Releveling speed. The releveling speed should be 2...3 [0.01m/s].
CRE SPE [0.01m/s] Creep speed. The creep speed should be 6...8 [0.01m/s]. Do not exceed
recommended max. value of 10.
ACC [0.01m/s^2] Acceleration rate. Can be decreased independently from nominal speed or
deceleration. Do not exceed recommended value of 80.
2
Example: for an acceleration rate of 0,5m/s set ACC = 50 [0.01m/s²]
DEC [0.01m/s^2] Deceleration rate. Can be decreased independently from nominal speed or
acceleration. Do not exceed recommended value of 80.
2
Example: for a deceleration rate of 0,5m/s set DEC = 50 [0.01m/s²]
Parameter Description
Mot Fnom [0.1Hz] Nominal motor frequency specified by motor name plate
Mot Vnom [V] Nominal phase-to-phase voltage specified by motor name plate *)
Mot Nnom [rpm] Nominal asynchronous rpm specified by motor name plate