Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

Generators BASIC GSL EN

Download as pdf or txt
Download as pdf or txt
You are on page 1of 25

OWNER’S MANUAL Please, read this manual

carefully before use!


ENG

Gasoline Powered Generator


KSB 1200C
KSB 2200A
KSB 2200C
KSB 2800A
KSB 2800C
KSB 3500C
KSB 6500C
KSB 6500CE
TABLE OF CONTENTS
1. PREFACE 2
2. SAFETY PRECAUTIONS 2
2.1. Work area 2-3
2.2. Electrical Safety 3
2.3. Personal Safety 3-4
2.4. Safety Precautions for Gasoline Powered Generator Operation 4
3. SAFETY SYMBOLS 5
3.1. Description of safety symbols when operating the generator 5
4. DESCRIPTION OF GENERATOR INSCRIPTIONS 6
5. GENERAL VIEW AND COMPOSITION
OF THE GASOLINE POWERED GENERATOR 7
6. GENERATOR SPECIFICATIONS 8-9
7. GENERATOR DELIVERY PACKAGE 10
8. CONTROL PANELS 10
9. COMMISSIONING 12
10. GETTING STARTED 13
10.1. Checking the fuel level 13
10.2. Checking the oil level 13
11. ENGINE START 14
11.1. Gasoline Powered Generator Engine Start 14
12. ENGINE STOP 15
12.1. Gasoline Powered Generator Stop 15
13. MAINTENANCE 15
14. RECOMMENDED MAINTENANCE SCHEDULE 16
15. SPARK PLUG MAINTENANCE 16
16. RECOMMENDED OILS 17
17. AIR FILTER MAINTENANCE 18
18. GENERATOR STORAGE 19
19. GENERATOR TRANSPORTATION 19
20. GENERATOR DISPOSAL 19
21. TROUBLESHOOTING 20
22. AVERAGE POWER RATINGS OF DEVICES 21
23. WARRANTY PROVISIONS 22

1
1. PREFACE
Thank you for your purchase of K&S Basic generator. This owner’s manual
contains safety instructions, a description of the use and commissioning of K&S
Basic generators and procedures for their maintenance.

The generator manufacturer may make some modifications that may not be
reflected in this manual. The manufacturer reserves the right to make changes
in the product design, configuration and construction. The images and drawings
in this manual are for reference only and may differ from the actual components
and inscriptions on the products.

Contact information that you are free to use in case of any problems can be found
at the end of this manual. All information in this manual is correct to the best of
our knowledge and belief at the date of its publication. The current list of service
centers can be found on the official importer's website: www.ks-power.de/en

! WARNING - DANGER! !
Please read this manual carefully before first in order to ensure
equipment integrity and avoid possible injuries.

ABBREVIATIONS

KSB -K&S Basic electric generator


А- Aluminum alternator winding
С- Copper winding

Please read this manual carefully. Pay particular attention to information that
starts with characters/words:

! WARNING - DANGER! !
Failure to observe the recommendation indicated by this sign may result in
serious injury or death to the operator or unauthorized persons.

! PLEASE NOTE! !
Useful information on the use of the device.

2. SAFETY PRECAUTIONS
2.1. WORK AREA
As exhaust gases contain poisonous carbon dioxide (CO2) and carbon monoxide
(CO) gases which are dangerous for life, it is strictly forbidden to install the
generator in residential buildings, premises connected to residential buildings
by a common ventilation system, other rooms from which exhaust gases may
enter living premises.
2
-_ Do not use the generator in the rain, snow and high humidity. Do not touch
the generator with wet hands and expose to direct sunlight for a long time. It
is recommended to store and use the generator indoors or in well-ventilated
premises.
-_ Always install the generator on a flat solid horizontal surface. The generator is
equipped with dampers to reduce vibration during operation and avoid damage
to the surface where the generator is installed.
-_ Do not use the generator near flammable gases, liquids or dust. During
operation of the generator, its exhaust system becomes very hot. This may cause
fire or explosion of these materials.
-_ Keep the work area clean and well lit to avoid injuries.
-_ Keep unauthorized persons, children and animals away from the running
generator.
-_ Always wear protective shoes and protective gloves when operating the
generator.

2.2. ELECTRICAL SAFETY

! WARNING - DANGER! !
The device generates electricity. Observe safety precautions to
avoid electric shock.
-_ The wiring diagram for the generator must comply with the installation rules
and applicable statutory requirements.
-_ All wiring connections of the generator must be carried out by a certified
electrician in accordance with all electrical codes and regulations.
-_ Avoid the generator supply from the mains during restoration of the power
supply.
-_ Avoid operating the generator in high-humidity environments. Do not allow
moisture to enter the generator, as this increases the risk of electric shock.
-_ Avoid direct contact with grounded surfaces (pipes, radiators, etc.).
-_ Be careful when working with the power cord. Replace it immediately in case
of damage, as damaged power cord increases the risk of electric shock.
-_ All connections of the generator to the mains must be carried out by a certified
electrician.
-_ Connect the electric generator to the protective ground before operation using
the terminal located on the generator control panel.
-_ Do not connect/disconnect the generator to/from power consumers while
standing in water, on wet or damp soil.
-_ Do not touch live parts of the generator.
-_ Only connect the generator to the power consumers that correspond to the
electrical specifications and power rating of the generator.
-_ Keep all electrical equipment dry and clean. Replace damaged or worn wiring.
Worn, damaged, or rusted terminals must be replaced as well.

2.3. PERSONAL SAFETY


-_ Do not operate the generator when you are tired or under the influence of
potent drugs, alcohol or medication. During operation, inattention can cause
serious injury.
3
! WARNING - DANGER! !
Failure to comply with these requirements may result in fire or
explosion of the generator, as well as fire in the building wiring.
-_ Avoid inadvertent start-up. Make sure the power switch is set to OFF when
turning off the generator.
-_ Do not operate the generator in areas with poor ventilation. Exhaust gases
contain poisonous carbon monoxide, which is life threatening!
-_ Make sure there are no foreign objects on the generator when it is turned on.
Use the product for its intended purpose only. The generator customer using the
device for other than the intended purpose shall be deprived of the right to free
warranty repair. Do not sit, stand on the generator and misuse the equipment.
- Always keep proper footing and balance when starting the generator.
- Do not overload the generator, use it for its intended purpose only.

2.4. SAFETY PRECAUTIONS FOR GASOLINE POWERED GENERATOR


OPERATION
Please note the following:
- Do not start the generator when it is under load.
-_ The generator must be installed at least 1 m away from explosive and
flammable substances and objects since its engine heats up during operation.
- Do not fill the fuel tank when the engine is running.
- Do not smoke while refueling.
-_ Only unleaded gasoline is recommended for the generator. After filling the
tank, remove all excess fuel from the surface. Do not use kerosene or other fuel.
Otherwise, the engine may be damaged.
- Observe the fuel tank while filling in order to avoid overfilling.
-_ Do not touch the exhaust system after starting the generator and during its
operation.
-_ Avoid operating the generator near water, in the rain or snow if there is a risk
of it becoming wet.
-_ Before starting the generator, learn how to stop the generator in case of an
emergency.

! WARNING - DANGER! !
Fuel pollutes soil and groundwater. Avoid gasoline leaking out
of the fuel tank!

4
3. SAFETY SYMBOLS
3.1. DESCRIPTION OF SAFETY SYMBOLS WHEN OPERATING THE GENERATOR
Fig. 1

a b c d
Fig. 2
1 2

e f g h i
a. Be careful when operating the device! Observe the safety instructions in this
manual.
b. Operate the generator only in well-ventilated indoor spaces or outdoors.
Exhaust gases contain СО2, whose vapors are life threatening.
c._ Do not operate or store the device in high-humidity environments.
d. Do not smoke while operating the generator!
e. The device generates electricity. Observe safety precautions to avoid electric
shock.
f._Read this owner’s manual carefully before operating the device.
g. Do not touch the generator with wet or dirty hands.
h. Observe fire safety regulations, do not operate the generator near open flame.
i._Do not touch! The generator dampener becomes hot during operation.

5
4. DESCRIPTION OF GENERATOR
INSCRIPTIONS
APART FROM THE SAFETY SYMBOLS, THE GENERATOR CONTAINS THE FOLLOWING
INSCRIPTIONS:

Specifications chart. Specifications vary


from model to model. For more information,
see “Generator Specifications”.

Noise level information for each model can be found in the


specifications chart.

Indicates the direction of opening the air


choke.

Indicates the position of the fuel valve. The “ON” position means
open and the “OFF” position means closed.

Fuel level indicator. The icon on the left


indicates that the fuel tank is full, and the
icon on the right indicates that the fuel tank
is empty.

Crankcase capacity
(varies from model to model)

Recommended oils.

Maintenance information in the language of the country where the generator is


sold can be found in the “Maintenance” section.

Note on the required


oil level in the crankcase
Ground
6
5. GENERAL VIEW AND COMPOSITION OF
THE GASOLINE POWERED GENERATOR
9 1
Fig. 3

8
2
7

6
5
4 3

12
11

10
1. Fuel cap 7. Air filter
2. Control panel 8. Air choke lever
3. Oil dipstick 9. Fuel level indicator
4. Oil drain cap 10. Damper
5. Hand starter 11. Alternator
6. Fuel valve 12. Spark plug

! PLEASE NOTE! !
The manufacturer reserves the right to make changes in the product
design, configuration and construction. Illustrations in this manual
are for reference only and may differ from actual components and
inscriptions on the products.

7
6. GENERATOR SPECIFICATIONS:
Model KSB 1200C KSB 2200A KS 2200C
Voltage (V) 230 230 230
Maximum power (kW) 1,0 2,2 2,2
Rated power (kW) 0,9 2,0 2,0
Frequency (Hz) 50 50 50
Current max(A) 4,35 9,57 9,57
Outlets 2*16А 2*16А 2*16А
Fuel tank capacity (L) 6 15 15
Operation time at 50% load 9 13 13
Voltmeter + + +
Noise level LPA(7m)/LWA, dB 70/95 72/97 72/97
Output 12 V (A) 12/8,3 12/8,3 12/8,3
Engine model KSB 90 KSB 220 KSB 220
Gasoline Gasoline Gasoline
Engine type powered powered powered
four-stroke four-stroke four-stroke
Power output (hp) 2,9 7 7
Crankcase capacity (cm ) 3
0,37 0,6 0,6
Engine capacity (cm ) 3
80 210 210
Voltage regulator AVR AVR AVR
Engine start Manual Manual Manual
Power factor (cosφ) 1 1 1
Dimensions (LxWxH), mm 470*365*380 605*440*435 605*440*435
Net weight (kg) 26 33.2 33.2
Protection class IP23M IP23M IP23M
Max. altitude above sea level (m) 1000 1000 1000
Relative humidity <95% <95% <95%
Rated voltage tolerance - max. 10%

8
GENERATOR SPECIFICATIONS:
Model KSB 2800A KSB 2800C
Voltage (V) 230 230
Maximum power (kW/kVA) 2,8 2,8
Rated power (kW/kVA) 2,5 2,5
Frequency (Hz) 50 50
Current max (A) 12,17 12,17
Outlets 2*16А 2*16А
Fuel tank capacity (L) 15 15
Operation time at 50% load 12 12
Voltmeter + +
Noise level LPA(7m)/LWA, dB 72/97 72/97
Output 12 V (A) 12/8,3 12/8,3
Engine model KSB 220 KSB 220
Gasoline Gasoline
Engine type powered powered
four-stroke four-stroke
Power output (hp) 7 7
Crankcase capacity (cm ) 3
0,6 0,6
Engine capacity (cm ) 3
210 210
Voltage regulator AVR AVR
Engine start Manual Manual
Power factor (cosφ) 1 1
Dimensions (LxWxH), mm 605*440*435 605*440*435
Net weight (kg) 36.2 36.2
Protection class IP23M IP23M
Max. altitude above sea level (m) 1000 1000
Relative humidity <95% <95%
Rated voltage tolerance - max. 10%

9
GENERATOR SPECIFICATIONS:
Model KSB 3500C KSB 6500C KSB 6500CE
Voltage (V) 230 230 230
Maximum power (kW) 3,0 5,5 5,5
Rated power (kW) 2,8 5,0 5,0
Frequency (Hz) 50 50 50
Current max(A) 13,04 23,91 23,91
Outlets 2*16А 1*16А, 1*32А 1*16А, 1*32А
Fuel tank capacity (L) 15 25 25
Operation time at 50% 10 9 9
load
LED display LED display
(voltage (voltage
Voltmeter/ LED display frequency
Voltmeter frequency
working hours) working hours)
Noise level LPA(7m)/
71/96 71/96 71/96
LWA, dB
Output 12 V (A) 12/8,3 12/8,3 12/8,3
Engine model KSB 230 KSB 410 KSB 410
Engine type Gasoline powered four-stroke
Power output (hp) 7 13 13
Crankcase capacity (cm ) 3
0,6 1,1 1,1
Engine capacity (cm ) 3
208 389 389
Voltage regulator AVR AVR AVR
Engine start manual manual manual/electric
Power factor (cosφ) 1 1 1
Dimensions (LxWxH), mm 605*445*450 695*530*560 695*530*560
Net weight (kg) 39.2 71 78.1
Protection class IP23M IP23M IP23M
Max. altitude above sea 1000 1000 1000
level (m)
Relative humidity <95% <95% <95%
Rated voltage tolerance - max. 10%

10
To ensure the reliability of the generator and increase its lifespan, the peak
capacities may be slightly limited by circuit breakers.
The optimum operating conditions are ambient temperature of 17 – 25 °C,
barometric pressure of 0.1 MPa (760 mm Hg), and relative humidity of 50 –
60%. Under such ambient conditions, the generator can guarantee maximum
performance in terms of the stated specifications. In case of deviations from the
above ambient values, the performance of the generator can be different.
Please note that in order to preserve the lifespan of the generator, continuous loads
should not exceed 80% of the rated power.

7. GENERATOR DELIVERY PACKAGE


_ 1. Generator
_ 2. Packaging
_ 3. Owner's manual
_ 4. Spark plug wrench

8. CONTROL PANEL
Fig. 4
1 2 3

4 5 6
1. Voltmeter
2. Safety switch
3. Outlets
4. Engine start button (ON/OFF)
5. 12V/8A DC outlet
6. Ground connector

USE CARE WHEN THE GENERATOR IS RUNNING:


- You can use the generator if the voltmeter indicates a value of 230 V ±10%
(50 Нz).
-_ Monitor the voltmeter and stop the generator if the value is too high.
-_ Avoid using 12 V voltage simultaneously with 230 V.

11
9. COMMISSIONING
1. Fill the crankcase with engine oil. The recommended amount of oil for each
model is indicated in the specification chart.
2. Check oil level with an oil dipstick. It should be between the MIN and MAX
marks on the oil dipstick.
3. Check fuel level.
4. Check the air filter for correct installation
In the first 20 operating hours of the generator, the following requirements
should be met:
1. During commissioning, do not connect power consumers, the power of which
exceeds 50% of the nominal (operating) power of the device.
2. After the first 20 operating hours, be sure to change the oil. It is better to drain
oil while the engine is still hot after operation to ensure quick and complete oil
draining.
3. Check and clean the air filter, fuel filter and spark plug.

To commission the generator, follow the maintenance recommendations for the


first month or twenty hours of operation (whichever comes first) contained in
the “Maintenance” section.
For commissioning models with elektrostart please charge the battery. Please
use additional battery charger (not included) to charge the battery or let the
generator work at least one hour at 50% load at the first start.

12
10. GETTING STARTED
10.1. CHECKING THE FUEL LEVEL
1. Wear protective gloves to avoid getting gasoline on your skin.
2. Unscrew the fuel cap and check the fuel level in the tank.
3. Fill the fuel tank to the fuel filter level.
4. Tighten the fuel cap securely.
Fig. 5
Fuel cap

! PLEASE NOTE! !
Only unleaded gasoline is recommended for the generator. Using
other fuels may cause damage to the engine.

10.2. CHECKING THE OIL LEVEL


1. Wear protective gloves to avoid getting oil on Fig. 6
your skin.
2. Unscrew the oil dipstick and wipe it out with a
clean cloth.
3. Insert the dipstick without screwing it in.
4. Check the oil level by a mark on the oil dipstick.
5. Add oil if its level is below the mark on the oil
dipstick.
6. Tighten the oil dipstick.

! PLEASE NOTE! !
If the generator has not been used for a long time, recharge the
battery with a charger (not included).

13
11. ENGINE START
! WARNING - DANGER! !
Before starting the engine make sure that the total power of tools or
power consumers corresponds to the rated power of the generator.
Do not exceed the rated power of the generator. Do not connect
any devices before the engine start! In the power supply mode, the
generator should operate no longer than 30 minutes in the range
from rated to maximum power.
Before connecting any devices to the generator, make sure that they are in
good condition. If the device that was connected suddenly stopped or failed,
immediately disconnect the power using a safety switch, disconnect the device
and check it out.

! WARNING - DANGER! !
Do not connect two or more devices simultaneously. The start-up
of many devices requires high power. Devices should be connected
in turn according to their power rating. Do not connect any power
consumers within the first 3 minutes after the generator start.

11.1. GASOLINE POWERED GENERATOR ENGINE START


1. Move the fuel valve to the “OPEN” position.
2. Set the air choke to the closed position.
3. To start the generator manually, grasp the starter handle and slowly pull
it until resistance is felt. Pull the starter cord to the full length with a sharp
movement.
4. Set the air choke to the “OPEN” position.

Könn er
S Söhnen
Fig. 7K
&
&

Fuel valve
Closed

Open Hand starter


Air choke OPEN

closed open CLOSE

14
12. ENGINE STOP
! PLEASE NOTE! !
Disconnect all devices before stopping the generator! Do not stop the
generator if it has any devices connected to it. This may disable the
generator!
12.1. GASOLINE POWERED GENERATOR STOP:
1. Disconnect all power consumers from the generator, set the safety switch to
the OFF position.
2. In case of manual start, set the engine switch to OFF.
3. In case of electric start, set the key to OFF.
4. Move the fuel valve to the “CLOSE” position.
5. Allow the generator to operate at idle for 3 minutes so that the alternator
cools down.
13. MAINTENANCE
Maintenance work listed in section "Maintenance" should be performed on a
regular basis. If you cannot perform maintenance work on your own, please
contact the authorized service center to request the required maintenance work.

! PLEASE NOTE! !
The manufacturer shall not be liable for any damage caused by failure
to perform maintenance work.
Such damage also includes:
-_ Damage resulting from the use of non-original spare parts;
-_ Corrosive damage and other effects of improper storage of equipment;
-_ Damage caused by maintenance work performed by unskilled technicians.
The current list of service centers can be found on the exclusive importer's
website: www.ks-power.com.ua. Main service center: Kyiv, 47 Elektrotekhnichna
Str., Tel.: (096) 967 43 31, (050) 147 35 39, (093) 100 06 47.

Observe the instructions in this manual!


The generator must be maintained, operated and stored in accordance with the
instructions in this manual. The manufacturer shall not be liable for damage and
loss caused by failure to comply with safety and maintenance regulations.
This primarily applies to:
-_ The use of lubricants, fuels and motor oils not authorized by the manufacturer;
-_ Technical changes to the product;
-_ The misuse of equipment;
-_ Indirect losses caused by operation of the product with defective parts.

15
14. RECOMMENDED MAINTENANCE
SCHEDULE

First month or after 20

after 100 working hrs


after 50 working hrs

Each year or after


Each 3 months or

Each 6 months or

300 working hrs


Before starting

working hours
Service type
Node
Checking
level V
Motor oil
Changing V V
Checking /
Cleaning V V V
Air filter
Changing V
Sparking Cleaning V V
plug Changing V
Checking
level V
Fuel tank
Cleaning V
Fuel filter Cleaning V

15. SPARK PLUG MAINTENANCE


A spark plug is an important element that ensures proper engine operation. It
must be intact, properly gapped and free of deposits.
Inspecting the spark plug:
1. Remove the spark plug cap.
2. Unscrew the spark plug with the appropriate wrench.
3. Visually inspect the spark plug. If the spark plug is damaged, it must be
replaced. It is recommended to use the F7TC spark plug.
4. Measure the gap. It should be in the range of 0.7 – 0.8 mm.
5. Before re-using the spark plug, it must be cleaned from deposits with a metal
brush. After that, set the correct gap.
6. Screw in the spark plug back with the dedicated spark plug wrench.
7. Replace the spark plug cap.
Spark plug 0,60 - 0,80 мм
Fig. 8 Fig. 9

Electrodе
16
16. RECOMMENDED OILS
Motor oil significantly affects the engine performance and is the main factor that
determines its service life. Use oil intended for four-stroke automobile engines,
as it contains detergent additives that meet or exceed the SE standards according
to the APE classification (or equivalent). Generally, it is recommended to use oil
with a viscosity of SAE 10W-30. Motor oils with a different grade shown in the
table can be used only if the average air temperature in your area does not fall
outside the specified temperature range. SAE oil viscosity or oil service category
is indicated on the APE tank label.

5W-30, 10W-30
0
-20 -10 0 10 20 30 40 C

REPLACING OR ADDING MOTOR OIL


If the oil level drops, fresh oil must be added to ensure proper operation of the
generator. Check the oil level according to the maintenance schedule.
To drain oil, proceed as follows:
1. Wear protective gloves to avoid getting oil on your skin.
2. Place an oil drain tray under the engine.
3. Unscrew the drain cap located on the engine under the dipstick cap with a
10 mm wrench (for generators up to 3.0 kW) or 12 mm (for generators above
3.0 kW).
4. Wait for the oil to drain.
5. Replace the drain cap and tighten securely.
6. It is better to drain oil while the engine is still hot after operation to ensure
quick and complete oil draining.
To add oil, proceed as follows:
1. Wear protective gloves to avoid getting oil on your skin.
2. Make sure the generator is mounted on a flat, level surface.
3. Unscrew the dipstick cap on the engine.
4. Use a funnel to fill the crankcase with high-grade oil. The funnel is not
included. After filling, the oil level should be close to the top of the oil filler.

Fig. 10

Fill to here

Dipstick cap Drain cap

17
! WARNING - DANGER! !
Oil pollutes soil and groundwater. Avoid oil leaking out of the
crankcase. Dump used oil into the sealed container.
Hand over used oil to waste oil collection point.

17. AIR FILTER MAINTENANCE


The air filter should be checked for contamination from time to time. Regular
maintenance of the air filter is necessary to maintain sufficient air flow in the
carburetor.

Cleaning the filter


1. Open the clips on the top cover of the air filter.
2. Remove the sponge filter element.
3. Remove all dirt inside the empty air filter housing.
4. Clean the filter element thoroughly in warm soapy water.
5. Dry the sponge filter.
6. Soak a dry filter element in engine oil, and then squeeze out excess oil.

! PLEASE NOTE! !
Replace the air filter every 50 operating hours of the generator
(every 10 hours in dirty conditions). Fig. 11
Cover spring Air filter cover

Filter

Cover spring

1 2 3 4

Clean Squeeze out Soak Squeeze out

18
18. GENERATOR STORAGE
The generator must be stored in a dry, well-ventilated area that is free from dust.
Keep away from children and animals. It is recommended to store and use the
generator at a temperature of -20 to +40 °C. Do not expose the generator to
direct sunlight and precipitation.

! PLEASE NOTE! !
Note! The generator must always be ready for use. Any malfunctions
in the generator must be repaired before placing the generator in
storage.

! PLEASE NOTE! !
Before long-term storage of the generator when the engine is
running, close the fuel valve of the fuel tank and allow the engine to
work gasoline out of the carburetor. Wait until the engine stops.
In case of lengthy generator downtime, observe the following
conditions:
-_ External parts of the generator and engine, especially cooling fins, must be
thoroughly cleaned.
-_ Unscrew the carburetor float chamber screw, empty the chamber.
-_ Remove the spark plug.
-_ Unscrew the oil drain screw and drain the oil.
-_ Add a teaspoon of engine oil (5 – 10 ml) to the cylinder. After that, pull the
starter cord several times so that the oil spreads along the cylinder walls.
-_ Replace (screw in) the spark plug.
-_ Pull the starter handle until resistance is felt so that the piston is at the top of
its stroke. As a result, the inlet and outlet valves of the generator will be closed
and no internal corrosion of the engine will occur if the device is stored in that
position.
-_ Release the starter handle smoothly.
-_ Remove the battery terminals. Grease the battery and connection terminals
with anti-oxidation grease.

19. GENERATOR TRANSPORTATION


For convenient transportation of the generator, use the original packaging of
the generator. Secure the generator packaging to prevent the generator from
tipping over during transportation. Before transporting the generator, drain the
fuel and disconnect the battery terminals.
To lift or handle the generator on site, grasp it by the frame. Be careful when
handling the heavy generator (40 to 90 kg). It is recommended that the
generator be carried by at least two people. Move carefully, do not put your feet
under the generator frame.

20. GENERATOR DISPOSAL


To prevent damage to the environment, do not dispose of the generator in normal
household waste. Dispose of the generator in the safest way by handing it over to
dedicated waste collection points.
19
21. TROUBLESHOOTING
Fault Probable cause Remedy
The engine start key (button) Set the engine start key
is set to the OFF position (button) to the ON position
The fuel valve is set to the“CLOSE” Move the fuel valve to the
position “OPEN” position
Air choke is open Close the air choke lever
Engine will not Fuel tank is empty Fill in the fuel tank
start Fuel tanks contains dirty or
Replace fuel in the fuel tank
used fuel
Clean the spark plug or
Spark plug smoked or
replace it with a new one; set
damaged; wrong distance
the correct distance between
between electrodes
the electrodes
Fuel tank is dirty Clean the fuel tank
Air filter is dirty Clean the air filter
Reduced engine Water in fuel tank and/
Empty the fuel tank, fuel line
power / troubled or carburetor; clogged
and carburetor
carburetor
engine start
Wrong distance between Set the correct distance
spark plug electrodes between the electrodes.
Cooling fins are contaminated Clean the cooling fins
Engine overheating Air filter is dirty Clean the air filter
Circuit breaker tripped Set the circuit breaker to ON
Check cables for normal
Engine starts, but Connection cables of poor
operation; replace, if
quality
no output voltage extension cable is used
Try connecting another
Faulty connected device
device
Device overload Try to connect less equipment
Generator works,
Short circuit of one of the Try disconnecting the faulty
but does not support connected devices device.
connected electrical Air filter is dirty Clean the air filter
devices Insufficient engine speed Contact the service center

20
22. AVERAGE POWER CONSUMPTION OF
DEVICES
Device Power (kW)
Iron 500-1100
Hair dryer 450-1200
Coffee machine 800-1500
Electric cooker 800-1800
Toaster 600-1500
Heater 1000-2000
Vacuum cleaner 400-1000
Radio 50-250
Grill 1200-2300
Oven 1000-2000
Fridge 100-150
TV set 100-400
Perforator 600-1400
Drill 400-800
Freezer 100-400
Grinder 300-1100
Circular saw 750-1600
Crank gear 650-2200
Jigsaw 250-700
Planer 400-1000
Compressor 750-3000
Water pump 750-3900
Bench saw 1800-4000
Electric mower 750-3000
Electric motors 550-5000
Fans 750-1700
High pressure unit 2000-4000
Air conditioner 1000-5000

21
23. WARRANTY SERVICE TERMS
TERMS AND CONDITIONS:
The international manufacturer warranty is 1 year. The warranty period starts from the date of
purchase. In cases when warranty period is longer than 1 year according to local legislation please
contact your local dealer. The Seller which sells the product is responsible for granting the warranty.
Please contact the Seller for warranty. Within the warranty period, if the product fails because of
defects in the production process, it will be exchanged on the same product or repaired.
All faults caused by the manufacturer during the warranty period will be eliminated free of charge.
Warranty repair is carried out only if you have a fully completed warranty card, the Buyer’s signature
of acceptance of the warranty terms, as well as a document supporting the purchase (cash receipt,
sales slip or invoice). In the absence thereof, as well as in the event of errors or corrections not
authenticated by the seller’s seal or illegible inscriptions in the warranty card or tear-off coupon,
no warranty repair is carried out, no objections to quality are accepted and the warranty card is
withdrawn by the service center as invalid.
The device is accepted for repair clean and full.
WARRANTY DOES NOT COVER:
- If the user has failed to comply with the instructions in this manual.
- If the product features damaged or missing identification stickers or labels, serial numbers, etc.
- If product malfunction was due to improper transportation, storage and maintenance.
- In case of mechanical damages (cracks, chips, impact and fall marks, deformation of housing,
power cord, plug or any other components), including those resulting from the freezing of water (ice
formation), provided there are foreign objects inside the unit.
- If the product has been improperly installed and connected to the mains supply or misused.
- If the claimed malfunction cannot be diagnosed or demonstrated.
- If proper operation of the product can be restored following cleaning from dust and dirt,
appropriate adjustment, maintenance, oil change, etc.
- If the product is used for business related purposes.
- If faults are detected, which have been caused by product overload. Signs of overload are molten
or discolored parts as a result of high temperatures, damaged cylinder or piston surfaces, degraded
piston rings or connecting rod bushes.
- The warranty does not cover the failure of the product automatic voltage regulator due to careless
handling or mishandling.
- If faults are detected, which have been caused by instability of the user’s power grid.
- If there are faults caused by contamination or fouling such as contamination of the fuel, oil or
cooling system.
- If electrical cables or plugs show signs of mechanical or thermal damage.
- In the event of foreign liquids and objects, metal chips, etc. inside the product.
- If the malfunction is caused by the use of non-original spare parts and materials, oils, etc.
- If there are two or more faulty units that are not interconnected.
- If the damage was caused by natural factors such as dirt, dust, humidity, high or low temperature,
natural disasters.
- In case of simultaneous failure of the rotor and stator.
- For wear parts and accessories (spark plugs, nozzles, pulleys, filter and safety elements, batteries,
detachables, belts, rubber seals, clutch springs, axles, hand starters, grease, mountings, working
surfaces, hoses, chains, and tires).
- To preventive maintenance (cleaning, greasing, washing),
installation and adjustment.
- If the product was tampered with, independently repaired or modified.
- In case of malfunctions resulting from normal wear and tear as a result of long-term use (end of life).
- If product operation was not stopped and continued after detecting a malfunction.
- Batteries supplied with equipment are covered by a warranty of three months.
- When using low-grade or inappropriate fuel.
22
CONTACTS
Deutschland:
DIMAX International GmbH
Deutschland, Hauptstr. 134,
51143 Köln,
www.ks-power.de
Ihre Bestellungen
orders@dimaxgroup.de
Kundendienst, technische Fragen
und Unterstützung
support@dimaxgroup.de
Garantie, Reparatur und Service
service@dimaxgroup.de
Sonstiges
info@dimaxgroup.de

Polska:
DIMAX International
Poland Sp.z o.o.
Polen, Warczawska,
306B 05-082 Stare Babice,
www.ks-power.pl
info.pl@dimaxgroup.de

Україна:
ТОВ «Техно Трейд КС»,
вул. Електротехнічна 47, 02222,
м. Київ, Україна
www.ks-power.com.ua
sales@ks-power.com.ua

Россия:
ТД «Рус Энержи К&С» 129090,
г.Москва, проспект Мира,
д.19, стр.1, эт.1, пом.1,
комн.6б, офис 99В
www.ks-power.ru
info@ks-power.ru

You might also like