This document describes the specifications of a medium heavy thermoplastic flexible cable with copper conductors that are PVC insulated and sheathed. The cable comes in sizes ranging from 2 x 0.75 mm2 to 5 x 2.5 mm2 with copper conductors and has a rated voltage of 300/500 volts. The document provides details on the construction, specifications, applications and identification of cores for the cable.
This document describes the specifications of a medium heavy thermoplastic flexible cable with copper conductors that are PVC insulated and sheathed. The cable comes in sizes ranging from 2 x 0.75 mm2 to 5 x 2.5 mm2 with copper conductors and has a rated voltage of 300/500 volts. The document provides details on the construction, specifications, applications and identification of cores for the cable.
This document describes the specifications of a medium heavy thermoplastic flexible cable with copper conductors that are PVC insulated and sheathed. The cable comes in sizes ranging from 2 x 0.75 mm2 to 5 x 2.5 mm2 with copper conductors and has a rated voltage of 300/500 volts. The document provides details on the construction, specifications, applications and identification of cores for the cable.
This document describes the specifications of a medium heavy thermoplastic flexible cable with copper conductors that are PVC insulated and sheathed. The cable comes in sizes ranging from 2 x 0.75 mm2 to 5 x 2.5 mm2 with copper conductors and has a rated voltage of 300/500 volts. The document provides details on the construction, specifications, applications and identification of cores for the cable.
Medium Heavy Thermoplastic (COPPER CONDUCTOR, PVC INSULATED and SHEATHED)
NYMH Y Flexible Cable
(COPPER CONDUCTOR, PVC INSULATED, Type of Cable Rated Voltage : NYMHY : 300/500 Volt Specification : SPLN 46-6-2 : 1992 SNI 04-6629.5 2006 IEC. 60227-5 IEC and PVC SHEATHED)
CONSTRUCTION
Conductor Wall Thickness
Approx No. of Approx Standard Size Overall Packing Core Net. Weight Length Diameter Construction No. of Wire Insulation Sheath
- mm2 - - mm mm mm Kg/Km m -
2 0.75 f 24 0.6 0.8 7.8 83 100 Coil
2 1 f 32 0.6 0.8 8.2 93 100 Coil 2 1.5 f 30 0.7 0.8 9.4 124 100 Coil Type of Cable : NYMHY 2 2.5 f 50 0.8 1.0 11.0 179 100 Coil Rated Voltage : 350/500 Volt 0.75 3 f 24 0.6 0.8 8.2 95 100 Coil Size Range : 2 x 0.75 ... 2.5 mm 2 3 1 f 32 0.6 0.8 8.6 107 100 Coil 3 1.5 f 30 0.7 0.9 10.1 151 100 Coil 3 x 0.75 ... 2.5 mm 2 3 2.5 f 50 0.8 1.1 11.9 217 100 Coil 4 x 0.75 ... 2.5 mm 2 4 0.75 f 24 0.6 0.87 8.9 112 100 Coil 5 x 0.75 ... 2.5 mm 2 4 1 f 32 0.6 0.8 9.6 133 100 Coil Specification : SPLN 42-6-2-1991 4 1.5 f 30 0.7 1.0 11.0 184 100 Coil SNI 04-6629.5 2006 4 2.5 f 50 0.8 1.1 12.9 263 100 Coil
IEC. 60227-5 IEC 0.75
5 f 24 0.6 0.9 9.9 139 100 Coil 5 1 f 32 0.6 0.9 10.4 158 100 Coil Other Specification are available on request 5 1.5 f 30 0.7 1.1 12.1 223 100 Coil 5 2.5 f 50 0.8 1.2 14.2 320 100 Coil Application : Indoor location connection or portable application Identification of Cores Twin-Cores : Light-Blue, Black CHARACTERISTICS Three-Cores : System I Resistance at 20˚C Short Circuit Green with yellow stripe (G/Y), Blue, Brown No of. Current Carying Current at AC Voltage Core Size Capacity In Air at 30˚C Test 1 sec. System O Conductor Insulation
Brown, Black, Grey - mm2 Ohm / km M.Ohm.km Amper KA KV / 5 min
Four-Cores : System I 0.75 2 26.0 50 12 0.09 2 Green with yellow stripe (G/Y), Brown, Black, Grey 2 1 19.50 50 15 0.12 2 2 1.5 13.30 50 18 0.17 2 System O 2 2.5 7.98 50 25 0.29 2 Blue, Brown, Black, Grey 3 0.75 26.0 50 12 0.09 2 Five-Cores : System I 3 1 19.50 50 15 0.12 2 Green with yellow stripe (G/Y), Blue, Brown, Black, Grey 3 1.5 13.30 50 18 0.17 2 System O 3 2.5 7.98 50 25 0.29 2 Blue, Brown, Black, Grey, Black 0.75 4 26.0 50 12 0.09 2 Other colours are available on request 4 1 19.50 50 15 0.12 2 4 1.5 13.30 50 18 0.17 2 4 2.5 7.98 50 25 0.29 2 Construction : 1. Flexible Copper Conductor 5 0.75 26.0 40 12 0.09 2 5 1 19.50 40 15 0.12 2 2. Extruded PVC Insulated 5 1.5 13.30 40 18 0.17 2 3. Extruded PVC Outer Sheathed 2.5 5 7.98 40 25 0.29 2
Note* : If site condition are different ratings should be multiplied by rating factors as show in table page 78-83
60 PT JEMBO CABLE COMPANY Tbk. CATALOGUE LOW VOLTAGE CABLE 61