4VP01
4VP01
4VP01
General Description
Series 4VP01 direct operated proportional pressure
relief valves are equipped with one pressure port
(port P). The solenoid is located on the A port side of
the mounting pattern.
B Function P T A
Features
• Direct operated by proportional solenoid.
• Very low pressure adjustment of p min.
• 1 pressure port.
• Subplate mounting according to ISO 6264.
• 4 pressure ranges.
Use RE0M*W2 for new applications
Ordering Information
4VP01 G12 B
Proportional Pressure Orifice in Solenoid Design Seal Options
Pressure Range Port P Voltage Series Check
Relief Valve 12V / 2.3 A with
Factory
Code Description
0 Without
Bolt Kits:
(Standard)
BK209 (4) 10-14x1.25 SHCS
1 Ø 0.6 mm
BK375 (4) M5x30 SHCS
2 Ø 0.8 mm
3 Ø 1.0 mm
Weight: 1.8 kg (4.0 lbs.)
4 Ø 1.2 mm
4VP01.indd, ddp
Specifications
General
Size DIN NG6 / CETOP 3 / NFPA D03
Interface Subplate Mounting acc. ISO 6264
Mounting Position As desired, horizontal position preferred
Ambient Temperature -20°C to +70°C (-4°F to +158°F)
B
Range
Hydraulic
Maximum Operating Port P 350 Bar (5075 PSI); Port T depressurized
Pressure
Pressure Range 50 Bar (725 PSI), 105 Bar (1523 PSI), 210 Bar (3045 PSI), 350 Bar (5075 PSI)
Nominal Flow See p/Q Curves
Fluid Hydraulic oil as per DIN 51524...51535, other on request
Fluid Temperature -20°C to +60°C (-4°F to +140°F)
Viscosity Permitted 12 to 380 cSt / mm2/s (56 to 1761 SSU)
Recommended 30 to 80 cSt / mm2/s (139 to 371 SSU)
Filtration ISO Class 4406 (1999) 18/16/13 (acc. NAS 1638: 7)
Linearity ±2.8%
Repeatability <±1%
Hysteresis ±1.5 of pmax
Electrical
Duty Ratio 100% ED; CAUTION: Coil temperature up to 150°C (302°F) possible
Protection Class IP65 in accordance with EN60529 (plugged and mounted)
Supply Voltage 12 VDC
Maximum Current 2.3 amps
Coil Resistance 4 Ohm at 20°C (68°F)
Solenoid Connection Connector as per EN 175301-803
Power Amplifier PCD00A-400, recommended
4VP01.indd, ddp
p/Q Curves
PSI Bar Pressure Range 105 Bar (1523 PSI) PSI Bar Pressure Range 350 Bar (5075 PSI)
2030 140 5075 350
B
1450 100 3625 250
Pressure p
Pressure p
290 20 725 50
0 0
LPM 1 2 3 4 5 LPM 1 2 3 4 5
0 0
GPM .26 .58 .79 1.06 1.32 GPM .26 .58 .79 1.06 1.32
Flow (Q) Flow (Q)
PSI Bar Pressure Range 105 Bar (1523 PSI) PSI Bar
Pressure Range 350 Bar (5075 PSI)
203 14 508 35
174 12 435 30
Pilot Pressure pmin
145 10 363 25
116 8 290 20
87 6 218 15
58 4 145 10
29 2 73 5
0 0
LPM 1 2 3 4 5 LPM 1 2 3 4 5
0 0
GPM .26 .58 .79 1.06 1.32 GPM .26 .58 .79 1.06 1.32
Flow (Q) Flow (Q)
PSI Bar Pressure Range 105 Bar (1523 PSI) PSI Bar Pressure Range 350 Bar (5075 PSI)
1523 105 5075 350
5 LPM 5 LPM
1305 90 4350 300
1 LPM
Pressure
3 LPM
870 60 2900 200
218 15 725 50
0 0
0 20 40 60 80 100 0 20 40 60 80 100
Command Signal (%) Command Signal (%)
45.0
31.0 T (1.77)
(1.22) 32.5
P (1.28)
Important:
On initial start up
B
and after long shut down periods 15.0 40.5 17.5
bleed air from this plug (0.59) (1.59) (0.69)
73.0
.(2.87)
15.0
(0.59) Connection plug
according to EN175301-803
A
∅ 9.0
92.4 (0.35)
(3.64) PG 11 ∅
5.3
(0.21)
46.0
(1.81)
22.0
(0.87)
1/16”NPT
(for P, T)
111.6 36.5
(4.39) 156.6 (1.44)
(6.17)
Seal
Surface Finish Bolt Kit
Nitrile Fluorocarbon
BK375 4x M5x30 DIN 912 12.9 7.6 Nm (5.6 lb.-ft.)
SK-RE06MWN SK-RE06MWV
BK209 4x 10-24x1.25 ±15%
4VP01.indd, ddp