TECHNICAL MANUAL
For pumping of clear and slightly contaminated liquids Chromium steel (AISI 420) fine grained shafts are used
in: on OMK pumps. There is no big diameter difference
Water supply systems. along the shaft and it is possible and very easy to
Booster sets in high rise buildings and industry. dismantling the pump beginning from suction or
Water treatment. discharge ends.
Industrial washdown systems. Bearings
Fire extinguishing plants.
Boiler feed and condensate transfer. On both ends, bearing houses equipped with grease
Sanitary and cleaning installations. lubricated heavy duty ball bearings.
For industrial applications and public services. Bearing at the suction side is fixed. Extra axial load is
Water distribution services. carried by this bearing.
Industrial applications. Discharge side bearing is free at the axial direction
Shipbuilding, Mining, Power Stations, Filter Units. and it carries only radial load.
Irrigation plants. Throwers and lip seals on the shaft prevent leakage
Central heating systems. fluid from getting into bracket.
Thin, clean, non-aggressive and non-explosive liquids Uncooled gland packing is standard (Up to 110 °C).
free from solid particles and fibres.
Standardized, single acting, balanced and uncooled
Fresh water, potable water, boiler feed water, mechanical seal is optional (Up to 140 °C).
industrial water, sea and brackish water, hot water,
Double-acting and cartridge seals are upon request.
condensate, lye, etc.
For special applications, please consult to MAS DAF Technical Data
MAKİNA SAN. A.Ş.
Design Suction Flanges…… : DN 50...DN 125 ( PN 40 )
(DIN 2535)
The OMK Pump is a horizontal axis, radially split, ring Discharge Flanges… : DN 32...DN 80 ( PN 40 )
section design multistage centrifugal pump of non-self (DIN 2535)
priming type. Operating Pressure.. : 40 Bar
Impellers are between bearings, single entry, closed No of Stages……….. : 2-14
type and dynamically balanced. Impeller diameter will Capacity Range…… : 5-220 m³ / h
be corrected for optimal adherence to the required Head Range……….. : 30-400 m
duty point. Temp. Range………. : -10..1600C; Mech. Seal
The axial thrust is relieved by relieving boreholes in :- 10..1100C; Soft packing
each impeller. The remaining thrust can be borne by Speed up to………. : 3600rpm
large-sized bearings.
Pumps with exchangeable wear rings are available Shaft Coupling and Coupling Guard
upon request.
The pump series consists of 5 sizes. OMK 32, 40, 50, Connection of pump with driver unit by flexible coupling
65 and 80. Stages are from 2 up to max. 14 stages. without intermediate bushing. A coupling guard will be
Pump and motor are fitted on a common base plate included if the scope of supply includes pump, base
and connected to each other via flexible coupling. frame and coupling.
Flanges are acc. to DIN 2535. Flanges acc. to BS or Driver
ANSI are upon request.
Normally, discharge part is at motor side on top, Common electric motors according to IEC. Also, OMK
suction part is at dead end side on the right and series can be driven by combustion engines or turbines.
rotation of direction is clockwise when viewed from
Idendification Code for Pump
driver.
Suction and discharge nozzles may be a choice of
three 90° positions. By special request, it is possible OMK 40 / 12
to put the suction nozzle at the motor side. In this Pump Type
arrangement pump and motor rotation must be
counter clockwise. Discharge Flange Size
Please see the possible arrangements at “Different No of stages
Mounting Arrangements” section.
OMK Series
High Pressure Multistage Pumps
Performance Range – 50 Hz Mas Grup
360 320 420 54 363 69A 20A 213 212 400 301 211 401 56 300 362 88 322 36
Part List
No No
01 Discharge Casing 210 Key, Sleeve
02 Suction Casing 211 Key, First Stage Impeller
04 Stage Casing With Diffuser 212 Key, Standard Impeller
10 Last Stage Diffuser 213 Key, Last Stage Impeller
20 Impeller 214 Key, Coupling
20A Last Stage Impeller 220 V-Ring
30 Bearing Housing 240 Soft Packing
35 Bearing Cover (Discharge Side) 300 Stud For Gland
36 Bearing Cover ( Suction Side) 301 Casing Stud
54 Gland 320 Bolt, Bearing Cover
56 Lantern Ring 321 Bolt, Bearing House
60 Pump Shaft 322 Bolt, Bearing Cover
67 Space Sleeve 360 Shaft Nut
68 Space Sleeve 361 Shaft Nut
69 Split Ring 363 Nut, Casing Stud
69A Retaining Ring 400 O-Ring (Stage Casing)
70 Seal Sleeve 401 O-Ring (Seal Sleeve)
88 Thrower 420 Supporting Ring
200 Ball Bearing
OMK Series
High Pressure Multistage Pumps
Sectional Drawing and Part List (Mechanical Seal Design) Mas Grup
360 320 420 230 363 69A 20A 213 212 400 301 211 401 402 302 362 321 36
Part List
No No
01 Discharge Casing 212 Key, Standard Impeller
02 Suction Casing 213 Key, Last Stage Impeller
04 Stage Casing With Diffuser 214 Key, Coupling
10 Last Stage Diffuser 220 V-Ring
20 Impeller 230 Safety ring
20A Last Stage Impeller 250 Mechanical Seal
30 Bearing Housing 300 Stud, Gland
35 Bearing Cover (Discharge Side) 301 Casing Stud
36 Bearing Cover ( Suction Side) 302 Mech. Seal Cover Stud
53 Mech. Seal Front Sleeve 320 Bolt, Bearing Cover
58 Mech. Seal Cover 321 Bolt, Bearing
60 Pump Shaft 360 Shaft Nut
67 Space Sleeve 361 Shaft Nut
68 Space Sleeve 362 Stud, Mech. Seal cover
69 Split Ring 363 Nut, Casing Stud
69A Retaining Ring 400 O-Ring (Stage Casing)
70 Seal Sleeve 401 O-Ring (Seal Sleeve)
200 Ball Bearing 402 O-Ring
210 Key, Sleeve 420 Supporting Ring
211 Key, First Stage Impeller
OMK Series
High Pressure Multistage Pumps
ATEX Description Mas Grup
ATEX Codification
ATEX -95
II 2G /D c Tx (85 oC – 200 oC)
TEMPERATURE CLASS
Temperature class
Ignition temperature of Allowable temperature
required by the area
gas or vapor classes of equipment
classification
T1 > 450 °C T1 - T6
T2 > 300 °C T2 - T6
T3 > 200 °C T3 - T6
T4 > 135 °C T4 - T6
T5 > 100 °C T5 - T6
T6 > 85 °C T6
Code Description
II The Usage in other non-mining explosive atmospheres
2 2. Category: High level of protection
G For potentially explosive environments due to gases or vapors
T Temperature class
X ATEX Marking of the motor manufacturer
OMK Series
High Pressure Multistage Pumps
Technical Data Mas Grup
Material Options
2.1050.01
Components Material. No
0.6025
0.7040
1.4021
1.4301
1.4401
Suction & Discharge Casing ● o o o o
Stage Casing With Diffuser ● o o o o
Impeller ● o o o o
Last Stage Diffuser ● o o o o
Gland ● o
Shaft ● o o
Shaft Sleeve ● o o
Mech. Seal Cover ● o o o o ● - Standard Manufacturing
Bearing Housing ● o o - Optional
Bearing Cover ● o o o o
Material Equivalent
Description DIN 17007 EN-DIN ASTM
Cast Iron 0.6025 GJL-250 (GG25) A 48 Class 40-B
Nodular Cast Iron 0.7040 GJS-400-15 (GGG40) A 536 Gr.60-40-18
Cast Bronze 2.1050.01 G-Cu Sn 10 B 584 C 90700
Chrome Steel 1.4021 X20 Cr 13 A 276 Type 420
Chrome Nickel Steel 1.4301 X5 Cr Ni 18.9 A 276 Type 304
Chrome Nickel Molybdenum Steel 1.4401 X5 Cr Ni Mo 18.10 A 276 Type 316
250 74 78 78 67
59 77 250 59
Balanced Mechanical Seal Balanced Mechanical Seal
(Burgmann H12N – Up to 25 Bar) (Burgmann H7N – Up to 40 Bar)
(Dependent on direction of rotation) (Independent on direction of rotation)
Soft Packing
When blocked, the pressure of the sealing medium exceeds the pressure of the pumped medium.
Application examples: pumped media that crystallize or carry solids, causing long-term damage to the seal.
Connector for external block on the pressure Connector for external block, Suction Side
side, Discharge Side (Optional). (Optional).
OMK Series
High Pressure Multistage Pumps
Technical Data Mas Grup
Standard
Manufacturing
Example: SL-DT-CW
(SL: Suction Left - DT : Discharge Top - CW : Rotation Clock Wise)
9
OMK Series
High Pressure Multistage Pumps
Pump Dimension Table Mas Grup
Lp e
a c b DNd
l e
d
hp
DNs
h1
u2 s
g k
K
G
Pump DN s DN d
a b Lp g G u2 h1 e hp d l k K s
Size mm ø mm ø
OMK 32 50 32 190 260 C+450 C+167 C+247 79 150 160 310 25 60 175 220 14
OMK 40 65 40 196 259 C+455 C+170 C+250 85 150 180 330 25 60 175 220 14
OMK 50 80 50 224 304 C+538 C+204 C+286 98 180 210 390 28 70 220 270 19
OMK 65 100 65 229 324 C+553 C+210 C+300 100 200 240 440 32 80 240 290 19
OMK 80 125 80 259 377 C+636 C+258 C+338 121 230 270 500 42 100 270 320 19
d
øT
f
B
Shaft End & Key Way Dimensions Flange Dimensions (PN 40)
Pump d l f Ga DN Df T Z ø B
Size mm ø mm mm mm mm ø mm ø mm ø Each mm ø mm
OMK 32 25 60 8 28 DN 32 140 100 4 18 20
OMK 40 25 60 8 28 DN 40 150 110 4 18 20
OMK 50 28 70 8 31 DN 50 165 125 4 18 22
OMK 65 32 80 10 35 DN 65 185 145 8 18 24
OMK 80 42 100 12 45 DN 80 200 160 8 18 26
DN 100 235 190 8 23 28
DN 125 270 220 8 27 30
OMK Series
High Pressure Multistage Pumps
Performance Curves OMK 32/2 Mas Grup
OMK Series
High Pressure Multistage Pumps
Performance Curves OMK 32/3 Mas Grup
OMK Series
High Pressure Multistage Pumps
Performance Curves OMK 32/4 Mas Grup
OMK Series
High Pressure Multistage Pumps
Performance Curves OMK 32/5 Mas Grup
OMK Series
High Pressure Multistage Pumps
Performance Curves OMK 32/6 Mas Grup
OMK Series
High Pressure Multistage Pumps
Performance Curves OMK 32/7 Mas Grup
OMK Series
High Pressure Multistage Pumps
Performance Curves OMK 32/8 Mas Grup
OMK Series
High Pressure Multistage Pumps
Performance Curves OMK 32/9 Mas Grup
OMK Series
High Pressure Multistage Pumps
Performance Curves OMK 32/10 Mas Grup
OMK Series
High Pressure Multistage Pumps
Performance Curves OMK 32/11 Mas Grup
OMK Series
High Pressure Multistage Pumps
Performance Curves OMK 32/12 Mas Grup
OMK Series
High Pressure Multistage Pumps
Performance Curves OMK 32/13 Mas Grup
OMK Series
High Pressure Multistage Pumps
Performance Curves OMK 32/14 Mas Grup
OMK Series
High Pressure Multistage Pumps
Dimension Table for OMK 32 – 1450 rpm – 50 Hz Mas Grup
L
Lp Lm
160
190 c 260 ca
8
160
28
H
hm 150
he 25
80 129 hb .
300 80x80 80
s
zxø
Wb Ws W
DN T Df
L4 L5
Lb
L
Lp Lm
160
190 c 260 ca
8
160
28
H
hm 150
he 25
80 129 hb .
300 80x80 80
s
zxø
Wb Ws W
DN T Df
L4 L5
Lb
L
Lp Lm
180
196 c 259 ca
8
180
28
H
hm 150
he 25
80 135 hb .
300 80x80 80
s
zxø
Wb Ws W
DN T Df
L4 L5
Lb
L
Lp Lm
180
196 c 259 ca
8
180
28
H
hm 150
he 25
80 135 hb .
300 80x80 80
s
zxø
Wb Ws W
DN T Df
L4 L5
Lb
L
Lp Lm
210
224 c 304 ca
8
210
31
H
hm 180
he 28
80 149 hb .
350 80x80 80
s
zxø
Wb Ws W
DN T Df
L4 L5
Lb
L
Lp Lm
210
224 c 304 ca
8
210
31
H
hm 180
he 28
80 149 hb .
350 80x80 80
s
zxø
Wb Ws W
DN T Df
L4 L5
Lb
L
Lp Lm
240
229 c 324 ca
10
240
35
H
hm 200
he 32
80 155 hb .
350 100x100 80
s
zxø
Wb Ws W
DN T Df
L4 L5
Lb
61
OMK Series
High Pressure Multistage Pumps
Dimension Table for OMK 65 – 2900 rpm – 50 Hz Mas Grup
L
Lp Lm
240
229 c 324 ca
10
240
35
H
hm 200
he 32
80 155 hb .
350 100x100 80
s
zxø
Wb Ws W
DN T Df
L4 L5
Lb
L
Lp Lm
270
259 c 377 ca
12
270
45
H
hm 230
he 42
80 171 hb .
350 100x100 80
s
zxø
Wb Ws W
DN T Df
L4 L5
Lb
L
Lp Lm
270
259 c 377 ca
12
270
45
H
hm 230
he 42
80 171 hb .
350 100x100 80
s
zxø
Wb Ws W
DN T Df
L4 L5
Lb
F ( Fx Fy Fz ) [N] M ( M x M y M z ) [Nm]
Suction and discharge flanges should be considered separate.
If the loads applied do not act simultaneously at their maximum values, it will be
permissible for one of the loads to exceed its permissible value to a maximum of 1.4
times.
The actual forces and moments can be connected by the relation below.
y x
y x
y x
F ( Fx Fy Fz ) [N] M (M x M y M z ) [Nm]
Suction and discharge flanges should be considered separate.
If the loads applied do not act simultaneously at their maximum values, it will be
permissible for one of the loads to exceed its permissible value to a maximum of 1.4
times.
The actual forces and moments can be connected by the relation below.
y x
DNd
y x
y x
This leaflet is subject to alteration without notice.
OMK Series
High Pressure Multistage Pumps
Moment of Inertia (Without Coupling) Mas Grup
Factory:
1. Organize Sanayi Bölgesi Parsel 249/5 Beyköy - DÜZCE / TURKEY
Tel: +90 (380) 553 73 88 Fax: +90 (380) 553 71 29