Experience the

Easy Breath
OXYGEN CONCENTRATOR
BPL

Dual Output User-Friendly


5 litre dual output with built-in nebulizer Is portable, user-friendly, safe, quiet and reliable

LCD Screen Secure, Reliable & Energy Efficient


User can view usage hours & adjust auto-shut Gas circuit is controlled by low pressure system
timer. which ensures secured & reliable operation. E
Energy efficient compressor with thermal protector.
Audio Alarm
Audio alarm for power failure, low Oxygen Timer Function
concentration, compressor failure, pressure Users can set the time in the range of 0 – 99 Min
cycle failure. for auto shut down

Low Noise Storage


Device has multilevel noise reduction measures One can place all sort of accessories in the
overhead compartment
Rugged & Durable
Flame retardant thermo plastic moulded cabinet Ease of Maintenance
for strength and durability Simple & ergonomic design makes it easily serviceable

Powered by
Scan the product image
above with BPL AR App to
view the product video of
PROMISE BPL OXY 5Neo Dual
A BPL Medical Technologies
Magazine
Download BPL-AR App to see this catalogue come to life
www.bplmedicaltechnologies.com Download BPL Promise App to experience the latest in medical technology
BPL

Product Specifications
Input Power 400VA
Input Voltage AC 220V± 10% , 50Hz-60Hz
Size 55.6cm X 28.5cm X 47cm (HXWXD)
Weight 25 Kg
Outlet 02
Outlet Pressure 20kPa ~ 50kPa (2.9psi ~ 7.25psi)
Adjustable Flow Rate 0.5 ~5 L / min
Noise ≤55dB (A)

Normal Operating Condition


Temperature Range 10˚ C to 35˚C
Atmospheric Pressure 860hPa ~ 1060 hPa (12.47 psi ~ 15.37 psi)
Relative Humidity 30% ~ 75%, Non- Condensation
Altitude Upto 1828 Mtr (6000ft) above sea level

Transportation & Storage Conditions


Temperature Range -20˚ C to +60˚C
Atmospheric Pressure 700hPa ~ 1060 hPa (10.15 psi ~ 15.37 psi)
Relative Humidity 10% ~ 93% Non-condensation
Classification Equipment Class II Type BF
Purity 95.5% to 87%
Maximum Nebulization Rate ≥015mL/min
• Low Oxygen concentration alarm
• Power Failure alarm
Alarms
• Compressor failure alarm
• Pressure Cycle failure alarm

• Stage 1 Filter
Filters • Stage 2 Filter
• Humidifier Bottle filter

Standard Accessories
Humidifier Bottle 1 Nos.
Nasal Cannula with Extension Tubing 1 Set
Filter 1 Set
Fuse Tube 2 Sets
Nebulizer Kit 1 Set
Operating Manual 1 Nos.
Power Cord 1 Nos.
*Technical specification subject to change