18 Vetogrout EG340 - 180321
18 Vetogrout EG340 - 180321
18 Vetogrout EG340 - 180321
Vetogrout EG340
Waterproof dynamic load bearing
epoxy grout
Uses
u Grouting & anchoring bridge bearings and pile
caps.
u Industrial applications where chemical
resistance and rapid strength development are
required.
u Under-plate grouting & heavy machine beds.
u Dynamic and cyclic load situations grouting.
u Demanding grout thicknesses up to 200mm.
Product Description
Vetogrout EG340 is a multi-component grout composed of epoxy resin, hardener, and selected aggregates. It is
supplied as a pre-weighed pack ready to use on-site that required only mixing to produce a free flow precision grout.
Vetogrout EG340 is specially formulated for use where heavy dynamic loads exist, high physical and mechanical
properties are required with excellent chemical resistance. Typical uses include rail grouting, crane rails, pile cap
treatment, bridge bearings, fixing rock bolts and anchors, cavity filling, and high-speed turbine base grouting.
Flow Characteristics
Usage Instructions
The maximum distance of flow is governed by the gap
Surface Preparation thickness, the head of grout applied, and the ambient
temperature. The following table gives typical data for
Substrate flow design.
All contact surfaces must be free from oil, grease, free-
standing water, or any loosely adherent material. Cut ºC Gap Hydrostatic Maximum Flow
back concrete surfaces to a sound base. All dust must Thickness Head (mm) (mm)
be removed, and bolt holes or fixing pockets blown (mm)
clean any dirt or debris. 25 50 100 1400
40 50 100 1800
Steel surfaces
25 80 100 1600
All steel surfaces should be shot blasted free of rust
40 80 100 2100
and flaky mill scale. Protect the Cleaned surfaces by
applying Vetoprime EP491. Cleaning
Form-work Remove Vetogrout EG340 from tools and equipment
with Vetonit Solvent XX400 immediately after use.
The form-work should be constructed to be leak-proof
Remove cured material mechanically.
as Vetogrout EG340 product is free-flowing grouts. Loss
of grout once the material is placed but not hardened
will result in incomplete filling of the gap.
Packaging & Coverage
For free flow grout conditions, it is essential to provide a Product Pack Size Theoretical Yield
hydrostatic head of grout. To achieve this, use a feeding Vetogrout EG340 20 Kg kit 10 -11.5 Liters
hopper system.
Stated consumption data are for general guidance.
For deep-section placing in inaccessible, use extended Actual consumption depends on the nature of
widths chains to encourage lateral movement and substrate, method of application, and wastage.
complete filling of the gap, thus eliminating air
pockets. For further information, please contact Saveto Shelf Life & Storage
for specific advice.
The original sealed kit of Vetogrout EG340 has a shelf
life of 12 months, provided it is stored clear of ground
Technical Data Sheet -Vetogrout EG340
Mixing
in a dry and shaded place.
Pour all the contents of the hardener pack into the base
container. Mix using a slow-speed power mixer until Health & Safety
homogeneous.
Vetogrout EG340 Contains resins that may cause
Pour all the resultant liquid into a container with a sensitization by skin contact. Avoid contact with
capacity of 20-25 liters. Add all the filler provided for skin and eyes and inhalation of vapor. Wear suitable
the product. Mix using a slow-speed power mixer for protective clothing, gloves, and eye/face protection.
two minutes or until a uniform color is achieved in the Barrier creams provide additional skin protection.
grouts. Should accidental skin contact occur, remove
immediately with a resin-removing cream, followed by
Placing
soap and water. Do not use solvent. In case of contact
The mixed grout should be poured steadily from one with eyes, rinse immediately with plenty of clean water
side only to eliminate the entrapment of air. and seek medical advice. If swallowed, seek medical
attention immediately. Do not induce vomiting.
Continuous grout flow is essential. Sufficient grout
must be available before starting. Regulate the time it Vetogrout EG340 is non-flammable.
takes to pour a batch to the time taken to prepare the
Vetonit Solvent XX400 is flammable, do not expose to
next batch.
direct flame. Keep away from heat sources.
LEGAL DISCLAIMER
Saveto endeavors to ensure that any advice, recommendations, information it may give is accurate and correct. It cannot accept any
liability either directly or indirectly arising from the use of its products because it has no direct or continuous control over where or how
its products are applied, whether or not following any advice, specification, recommendation, or information given by us. Saveto has the
right to change any of the technical datasheets’ specifications upon its discretion without prior notification.
Hard copies of TDSs are printed once or twice a year. Our technical data sheets are continuously updated as per R&D improvements and
new 3rd party testing; kindly refer to our website for the latest updated TDSs.