Mcdonnell & Miller Service Parts Catalog
Mcdonnell & Miller Service Parts Catalog
Mcdonnell & Miller Service Parts Catalog
MM-701E
PS-850 5
Series
PSE-800 Series 5
RB Series 6
• Combination Low Water Cut-Off/
Pump Controllers for Steam Boilers
751P/752P Series 5
42/42A and 18
• For Steam Boilers 42S/42S-A
61 7
93/193 20
63 8
94/194 22
64 10
764 12
150/157
67 14 150S/157S 24
767 16 1575 29
69 17
157S-RBP 28
1
Table of Contents
water FeederS For SerieS Page water FeederS For SerieS Page
25-A 34
101-A 32
221 35
• Mechanical 47/47-2 40
551-S 36
247/247-2 42
847 37
51/51-2 44
851 38
51-S/51-S-2 46
851-S 39
53/53-2 48
VaLVeS
• Test-N-Check® TC-4 50
2
Table of Contents
remote SenSorS For SerieS Page FLoat aCtuated For SerieS Page
RS 51 27-W 53
PneumatiC aCtuated
PFC 52
Liquid FLow For SerieS Page Liquid FLow For SerieS Page
FS4-3-T 56 FS7-4E 63
FS5 57 FS7-4W 63
FS8-W 58
air FLow
FS-251 59
AF1 64
FS-254 59
AFE-1 65
• High Sensitivity FS1 60
AF2 66
FS1-W 60
AF3 67
FS6 61
FS6-W 61
3
GENERAL INFORMATION LIQUID LEVEL CONTROLS FLOW SWITCHES BOILER CONTROLS
4
notes
Boiler Control Replacement Parts
Boiler Control Replacement Parts
Replacement Probes
BOILER CONTROLS
PA-800
For Repl. Probe Part Weight
Model Model No. Number Description lbs. (kg)
PA-800-U
For Repl. Probe Part Weight
Model Model No. Number Description lbs. (kg)
5
Boiler Control Replacement Parts
Replacement Probes
BOILER CONTROLS
PA-800-RX2
For Repl. Probe Part Weight
Model Model No. Number Description lbs. (kg)
PA-RB-122
PS-852-SP-24
RB-120
751P-MT-SP-120
752P-MT-SP-24
6
Boiler Control Replacement Parts
Low Water Cut-Offs – Float Type
For Steam Boilers
BOILER CONTROLS
Series 61
Low Water Cut-Offs
Series 61
model 6667
3 4 5 6
2
1
7
Boiler Control Replacement Parts
Low Water Cut-Offs – Float Type
For Hot Water Boilers
BOILER CONTROLS
Series 63
Low Water Cut-Offs
Series 63
63
63-HD 142600 Head mechanism 7.0 (3.2)
w/ No. 2 switch
63-B
63-BM
63-M-HD 143200 63-HD w/manual reset 7.0 (3.2) model 63-hd
63-M
Head mechanisms include a gasket and bolts.
8
Boiler Control Replacement Parts
Low Water Cut-Offs – Float Type
For Hot Water Boilers
BOILER CONTROLS
Series 63 (continued)
Low Water Cut-Offs
Components
1
2
4
5
9
Boiler Control Replacement Parts
Low Water Cut-Offs – Float Type
For Hot Water Boilers
BOILER CONTROLS
Series 64
Low Water Cut-Offs
10
Boiler Control Replacement Parts
Low Water Cut-Offs – Float Type
For Hot Water Boilers
BOILER CONTROLS
Series 64 (continued)
Low Water Cut-Offs
Components
11
8 9
1 3 5 6 7
10
4
2
11
Boiler Control Replacement Parts
Low Water Cut-Offs – Float Type
For Hot Water Boilers
BOILER CONTROLS
Series 764
Low Water Cut-Offs
model 64-hd
Components (shown on page 13)
Item Part Model Weight
Number Number Number Description lbs. (kg)
12
Boiler Control Replacement Parts
Low Water Cut-Offs – Float Type
For Hot Water Boilers
BOILER CONTROLS
Series 764 (continued)
Low Water Cut-Offs
Components
1 3 5 6 7
4
2
13
Boiler Control Replacement Parts
Low Water Cut-Offs – Float Type
For Steam Boilers
BOILER CONTROLS
Series 67
Low Water Cut-Offs
67
Series 67
67-LQHU 6667 153825 Head mechanism 1.5 (0.7)
model 67-Lqhu
Components (shown on page 15) (without quick
hook-up fittings)
Item Part Model Weight
Number Number Number Description lbs. (kg)
model 6667mV
14
Boiler Control Replacement Parts
Low Water Cut-Offs – Float Type
For Steam Boilers
BOILER CONTROLS
Series 67 (continued)
Low Water Cut-Offs
Components
Model 6667
2
4 5 6 7
15
Boiler Control Replacement Parts
Low Water Cut-Offs – Float Type
For Steam Boilers
BOILER CONTROLS
Series 767
Low Water Cut-Offs
Components
Item Part Model Weight
Number Number Number Description lbs. (kg)
Model 6667
2 3 4 5
16
Boiler Control Replacement Parts
Low Water Cut-Offs – Float Type
For Steam Boilers
BOILER CONTROLS
Series 69
Low Water Cut-Offs
Replacement Head Mechanisms
For Repl. Head Part Weight
Model Model No. Number Description lbs. (kg)
69
69-J
Series 69
169
369
469
569
369-MV
Components model 6667
9 8 6 7
2 3
4
1 5
17
Boiler Control Replacement Parts
Combination Low Water Cut-Off/Pump Controllers
For Steam Boilers
BOILER CONTROLS
Series 42S
model Swa-42S
18
Boiler Control Replacement Parts
Combination Low Water Cut-Off/Pump Controllers
For Steam Boilers
BOILER CONTROLS
Series 42 and 42S (continued)
Low Water Cut-Off/Pump Controllers
Components
5
3
19
Boiler Control Replacement Parts
Combination Low Water Cut-Off/Pump Controllers
For Steam Boilers
BOILER CONTROLS
#5 Switch
1 344800 SA91-30B Burner Switch 0.1 (.05)
Contact Assembly
(Red dot on terminal panel)
(Includes 1A terminal panel)
2 345000 SA91-30P Pump Switch 0.1 (.05)
Contact Assembly
(Blue dot on terminal panel)
(Includes 2A terminal panel)
20
Boiler Control Replacement Parts
Combination Low Water Cut-Off/ – Pump Controllers
For Steam Boilers
BOILER CONTROLS
Series 93 & 193 (continued)
Low Water Cut-Off/Pump Controllers
Components
4 5 6 7
1A 3
3
2
2
7B Switch
1A 2A
1 2
5 Switch
21
Boiler Control Replacement Parts
Combination Low Water Cut-Off/Pump Controllers
For Steam Boilers
BOILER CONTROLS
#5 Switch
1 344800 SA91-30B Burner Switch 0.1 (.05)
Contact Assembly
(Red dot on terminal panel)
(Includes 1A terminal panel)
2 345000 SA91-30P Pump Switch 0.1 (.05)
Contact Assembly
(Blue dot on terminal panel)
(Includes 2A terminal panel)
#7B Switch
1 344800 SA91-30B Burner Switch 0.1 (.05) Series 194
Contact Assembly
(Red dot on terminal panel)
(Includes 1A terminal panel)
2 309000 7B-1R Resistor/Slide 0.1 (.05)
Wire Assembly
3 345150 SA7-30 Terminal Panel 0.5 (.23)
22
Boiler Control Replacement Parts
Combination Low Water Cut-Off/ – Pump Controllers
For Steam Boilers
BOILER CONTROLS
Series 94 & 194 (continued)
Low Water Cut-Off/Pump Controllers
4 5 6 7
1A 3
3
2 2
7B Switch
1A 2A
1 2
5 Switch
23
Boiler Control Replacement Parts
Low Water Cut-Off/Pump
Controllers For Steam Boilers
BOILER CONTROLS
‘MD’Models
The ‘MD’ model should be used as a replacement
head when the boiler operating pressure is less than
50 psi. These were created to provide a control with
factory settings to compensate for the narrowing of
setpoints. The larger differential between pump on
and burner off reduces the potential for nuisance
burner shutdown.
24
Boiler Control Replacement Parts
Low Water Cut-Off/Pump Controllers
For Steam Boilers
BOILER CONTROLS
Series 150, 150S
Series 157, 157S
(continued)
25
Boiler Control Replacement Parts
Low Water Cut-Off/Pump Controllers
BOILER CONTROLS
IMPORTANT:
• Snap switches must be replaced as an assembly.
• We recommend complete head replacement to eliminate the need for field adjustment
of the switch assembly.
• Series 150S and 157S replacement switch assemblies are not interchangeable with
Series 150 and 157 mercury switch controls.
Note:
Manual reset models with date code 03K (October 2003)
or older require the purchase of a new head.
All
159S SWA-159S 310470 Snap-action 0.5 (.23)
Models switch assembly
model Swa-159S
Switch assemblies include a mounting bracket and color-coded terminal connection wires.
26
Boiler Control Replacement Parts
Low Water Cut-Off/Pump Controllers
BOILER CONTROLS
For Steam Boilers
Series 150, 150S
Series 157, 157S (continued)
7
Series 150 Head Gasket
and Casting
R
3 CATALOGUE NO.
150-14H
P.N. 325500
RAISED FLANGE
FLAT
FLANGE GASKET
4 CATALOGUE NO.
150-14
2 P.N. 325400
FLAT FLANGE
Series 150S
Components
Item Model Part Weight
Number Number Number Description lbs. (kg)
27
Boiler Control Replacement Parts
Low Water Cut-Off/Pump Controllers
For Steam Boilers
BOILER CONTROLS
2
1
Components
Item Model Part Weight
Number Number Number Description lbs. (kg)
model 157S-rBP
28
Boiler Control Replacement Parts
Low Water Cut-Off/Pump Controllers
For Steam Boilers
BOILER CONTROLS
Series 1575
Components
Item Model Part Weight
Number Number Number Description lbs. (kg)
1
1 150E-CU 310490 Control unit, automatic reset 2.07 (.96)
29
BOILER CONTROLS
30
notes
Notes
Boiler Control Replacement Parts
Water Feeders – Electric
BOILER CONTROLS
Series wF2 and wFe uni-match®
Electric Water Feeders
Components
Item Part Model Weight uni-match®
Number Number Number Description lbs. (kg)
31
Boiler Control Replacement Parts
Water Feeders – Electric
BOILER CONTROLS
Series 101-a
Electric Water Feeders
Components
Item Part Model Weight
Number Number Number Description lbs. (kg) Series 101-a
1
4
3
32
Boiler Control Replacement Parts
Water Feeders – Make-Up
BOILER CONTROLS
Series 21
Make-Up Water Feeders
Components
Item Part Model Weight
Number Number Number Description lbs. (kg)
11
10 3
2 4
7
9
33
Boiler Control Replacement Parts
Water Feeders – Make-Up
BOILER CONTROLS
Series 25-a
Make-Up Water Feeders
4 5
12
1 2
3
10
6
11
8 7
34
Boiler Control Replacement Parts
Water Feeders – Make-Up
BOILER CONTROLS
Series 221
Make-Up Water Feeders
Components
Item Part Model Weight
Number Number Number Description lbs. (kg)
10
3 11
4
2
7
9
35
Boiler Control Replacement Parts
Water Feeders – Make-Up
BOILER CONTROLS
Series 551-S
Make-Up Water Feeders
Replacement Head Mechanisms
For Repl. Head Part Weight
Series Model No. Number Description lbs. (kg)
1 NOTE:
2 One time float and bellows
replacement is required
4 when replacing bellows or
float assemblies with date
codes before February 2005
(05B).
4
6
Round Boss Hex Boss 5
Pilot Action Style Cartridge Style
Pre August 1995 After August 1995
8
7
* Units manufactured prior to August 1995 have a round
port pilot valve and a strainer assembly. These valve
and strainer assemblies can be replaced with the
current hex port cartridge valve and strainer assembly.
36
Boiler Control Replacement Parts
Water Feeders – Make-Up
BOILER CONTROLS
Series 847
Make-Up Water Feeders
Components
Item Part Model Weight
Number Number Number Description lbs. (kg)
2
1
10
4 4 9
6
Round Boss Hex Boss
5
Pilot Action Style Cartridge Style
Pre August 1995 After August 1995
8
7
* Units manufactured prior to August 1995 have a round
port pilot valve and a strainer assembly. These valve
and strainer assemblies can be replaced with the
current hex port cartridge valve and strainer assembly.
37
Boiler Control Replacement Parts
Water Feeders – Make-Up
BOILER CONTROLS
Series 851
Make-Up Water Feeders
Components
Item Part Model Weight
Number Number Number Description lbs. (kg)
2
1
9 11
4 4
10
6
Round Boss Hex Boss 5
Pilot Action Style Cartridge Style
Pre August 1995 After August 1995
8 7
* Units manufactured prior to August 1995 have a round
port pilot valve and a strainer assembly. These valve
and strainer assemblies can be replaced with the
current hex port cartridge valve and strainer assembly.
38
Boiler Control Replacement Parts
Water Feeders – Make-Up
BOILER CONTROLS
Series 851-S
Make-Up Water Feeders
Components
Item Part Model Weight
Number Number Number Description lbs. (kg)
2
1
11 13
4 4
12
5
6
7
8
10
39
Boiler Control Replacement Parts
Combination Mechanical Water Feeder/
Low Water Cut-Offs
BOILER CONTROLS
Series 47/47-2
Mechanical Water Feeder/Low Water Cut-Offs
Components
Item Part Model Weight
Number Number Number Description lbs. (kg)
Series 47
1 310453 CTRD-101 Cartridge and strainer kit .35 (.16)
40
Boiler Control Replacement Parts
Combination Mechanical Water Feeder/
Low Water Cut-Offs
BOILER CONTROLS
Series 47/47-2 (continued)
Mechanical Water Feeder/Low Water Cut-Offs
Components
11
12 8
9
7
6
6
10
5
14
15
13
3
2
1 4
17
16
41
Boiler Control Replacement Parts
Combination Mechanical Water Feeder/
Low Water Cut-Offs
BOILER CONTROLS
Series 247/247-2
Mechanical Water Feeder/Low Water Cut-Offs
Components
Item Part Model Weight
Number Number Number Description lbs. (kg)
Series 247
1 310453 CTRD-101 Cartridge & strainer kit .35 (.16)
42
Boiler Control Replacement Parts
Combination Mechanical Water Feeder/
Low Water Cut-Offs
BOILER CONTROLS
Series 247/247-2 (continued)
Mechanical Water Feeder/Low Water Cut-Offs
Components
8
9
6
6
5
10
11
3
2
1 4
43
Boiler Control Replacement Parts
Combination Mechanical Water Feeder/
Low Water Cut-Offs
BOILER CONTROLS
Series 51/51-2
Water Feeder/Low Water Cut-Offs
44
Boiler Control Replacement Parts
Combination Mechanical Water Feeder/
Low Water Cut-Offs
BOILER CONTROLS
Series 51/51-2 (continued)
Water Feeder/Low Water Cut-Offs
Components
1
2
4
6
8 10
9
Round Boss Hex Boss 11
Pilot Action Style Cartridge Style
Pre August 1995 After August 1995
Note: One time float and bellows replacement is required when replacing
bellows or float assemblies with date codes before February, 2005 (05B).
45
Boiler Control Replacement Parts
Combination Mechanical Water Feeder/
Low Water Cut-Offs
BOILER CONTROLS
Series 51-S/51-S-2
Water Feeder/Low Water Cut-Offs
46
Boiler Control Replacement Parts
Combination Mechanical Water Feeder/
Low Water Cut-Offs
BOILER CONTROLS
Series 51-S/51-S-2 (continued)
Water Feeder/Low Water Cut-Offs
Components
1
2
8
9
11
12
10
13
Note: One time float and bellows replacement is required when replacing
bellows or float assemblies with date codes before February, 2005 (05B).
47
Boiler Control Replacement Parts
Combination Mechanical Water Feeder/
Low Water Cut-Offs
BOILER CONTROLS
Series 53/53-2
Water Feeder/Low Water Cut-Offs
model 53-2m-hd
48
Boiler Control Replacement Parts
Combination Mechanical Water Feeder/
Low Water Cut-Offs
BOILER CONTROLS
Series 53/53-2 (continued)
Water Feeder/Low Water Cut-Offs
Components
1
2
4
8
10
11
Note: One time float and bellows replacement is required when replacing
bellows or float assemblies with date codes before February, 2005 (05B).
49
Boiler Control Replacement Parts
Valves
BOILER CONTROLS
Components
Series tC-4
Item Part Model Weight upper Valve
Number Number Number Description lbs. (kg)
Series tC-4
Lower Valve
50
Liquid Level Control Replacement Parts
remote Sensor
model rS-1-LP
4
2
2
1
51
Liquid Level Control Replacement Parts
Pneumatic Actuated
Series PFC
Liquid Level Controls
Components
Item Part Model Weight
Number Number Number Description lbs. (kg)
1
2
LIQUID LEVEL CONTROLS
52
Liquid Level Control Replacement Parts
Float Actuated
Series 27-w
Liquid Level Controls
Components
Item Part Model Weight Series 27-w
Number Number Number Description lbs. (kg)
53
Notes
notes
54
Flow Switch Replacement Parts
Flow Switches – Liquid
Series FS4-3
General Purpose Liquid Flow Switches
Components
For Item Part Model Weight
Model Number Number Number Description lbs. (kg)
All models
(except those below)
1 310451 FS4-15SS Stainless steel paddle kit 0.1 (.05) Series FS4-3
FLOW SWITCHES
FS4-3D
4 304300 FS1-17 SPDT switch (next to 0.3 (.14)
adjustment screw)
Note: Paddle kits include screws and washers.
COMM
ON
1" 2" 3" 6"
3
NORM
NORM SED
CLO
OPEN
CO RM
NO
4
M
M
ON
OP
EN
NO SED
CL
RM
O
(25mm)
2 (51mm)
1
(76mm)
(152mm)
FLO
W
55
Flow Switch Replacement Parts
Flow Switches – Liquid
Series FS4-3t
General Purpose Liquid Flow Switches
Components
Item Part Model Weight
Number Number Number Description lbs. (kg)
FLO
W 1" 1" 1/2"
Paddle Kit
FS4-3t
56
Flow Switch Replacement Parts
Flow Switches – Liquid
Series FS5
General Purpose Liquid Flow Switches
Components
Item Part Model Weight
Number Number Number Description lbs. (kg)
Series FS5
FLOW SWITCHES
1
Series FS5
57
Flow Switch Replacement Parts
Series FS8-w
General Purpose Liquid Flow Switches
Components
Item Part Model Weight
Number Number Number Description lbs. (kg)
2
(25mm)
(51mm)
(76mm) 3
(152mm)
58
Flow Switch Replacement Parts
Series FS250
General Purpose Liquid Flow Switches
Components
Item Part Model Weight
Number Number Number Description lbs. (kg)
FLOW SWITCHES
FS254
(25mm)
(51mm)
(76mm) 3
(152mm)
59
Flow Switch Replacement Parts
Flow Switches – Liquid
Series FS1-w
1
2
2
60
Flow Switch Replacement Parts
FLOW SWITCHES
Series FS6-w
1
2
2
61
Flow Switch Replacement Parts
Flow Switches – Liquid
FS7-4
FS7-4
FLOW SWITCHES
5
1
3 4
1" 6"
(25mm)
2
6
(152mm)
12"
Series FS7-4 & FS7-4S Paddle (305mm)
Series FS7-4, FS7-4L & FS7-4S Kit Series FS7-4L Paddle Kit
62
Flow Switch Replacement Parts
Flow Switches – Liquid
FS7-4E
3 306700 FS7-28 Bronze paddle kit 0.1 (.05)
FS7-4W
FLOW SWITCHES
FS7-4SE
4 306800 FS7-28S Stainless steel paddle kit 0.1 (.05)
FS7-4SW
FS7-4W
5 307200 FS7-W-43 Gasket 0.1 (.05)
FS7-4SW
Note: Paddle kits include screws and washers.
1 1
3 4
5
1" 6"
(25mm)
2 (152mm)
63
Flow Switch Replacement Parts
Flow Switches – Air
Series aF1
Air Flow Switches
Components
Item Part Model Weight
Number Number Number Description lbs. (kg)
3
4
64
Flow Switch Replacement Parts
Flow Switches – Air
Series aFe-1
Air Flow Switches
Components
Item Part Model Weight
Number Number Number Description lbs. (kg)
FLOW SWITCHES
Note: Paddle kits include screws and washers.
65
Flow Switch Replacement Parts
Flow Switches – Air
Series aF2
Air Flow Switches
Components
Item Part Model Weight
Number Number Number Description lbs. (kg)
66
Flow Switch Replacement Parts
Flow Switches – Air
Series aF3
Air Flow Switches
Components
Item Part Model Weight
Number Number Number Description lbs. (kg)
FLOW SWITCHES
1
67
Warranty & Return Policy
Warranty Policy Return Goods Policy
McDonnell & Miller warrants for a period of two (2) years Unused material may be returned for credit only with the
from the date of manufacture or one (1) year from date of written or oral consent of McDonnell & Miller. This
installation, whichever comes first, that all McDonnell & consent is in the form of an RGA number issued by
Miller and all Hoffman Specialty products furnished by it McDonnell & Miller, and is subject to the following conditions.
are free from defects in materials and workmanship.
1. Materials must be unused, of current design, and in
McDonnell & Miller’s liability for any breach of this original cartons.
Warranty shall be limited solely to replacement or repair
2. Credit will be issued based upon either a referenced
at the sole option of McDonnell & Miller, of any part or
invoice or product date code if an invoice is not
parts found to be defective during the Warranty Period
referenced. Requestor is to supply copy of the
providing the Product is properly installed and is being
referenced invoice if requested.
used for its intended purpose. Buyer must notify
McDonnell & Miller of any breach of this warranty, within 3. A 25% restocking charge will apply.
the aforementioned Warranty Period by notifying the 4. Unauthorized material returned to McDonnell & Miller
McDonnell & Miller representative with responsibility for will be either refused or sent back to the sender freight
servicing the Buyer’s account. Further, product alleged to collect by a carrier chosen by McDonnell & Miller.
be defective must be shipped by buyer to McDonnell &
Miller’s representative, transportation charges prepaid. 5. If material is received but subsequently found not to
have met the above conditions, it will be sent back to
It is expressly agreed that this shall be the sole and the sender freight collect by a carrier chosen by
exclusive remedy of the buyer, under no circumstances McDonnell & Miller.
shall McDonnell & Miller be liable for any costs. loss,
expense, damages, special damages, incidental damages 6. Products which are obsolete or made to special order
or consequential damages arising directly or indirectly are not returnable.
form the design, manufacture, sale, or use or repair of
the product whether based upon warranty, contract,
negligence or strict liability. In no event will liability
exceed the purchase price of the product.
The warranty and limits of liability contained herein are in
lieu of all other warranties and liabilities expressed or
implied. All implied warranties or merchantability and
fitness for a particular purpose are hereby disclaimed by
McDonnell & Miller and excluded from the warranty.
McDonnell & Miller neither assumes nor authorizes any
person to assume for it, any other Warranty obligation in
connection with the sale of the Product. This Warranty
shall not apply to any product or parts of products which
(a) have been repaired or altered outside of authorized
McDonnell & Miller facilities; (b) have been subject to
misuse, negligence or accident; or (c) have been used in
a manner contrary to McDonnell & Miller instructions.
In the case of Products not manufactured by McDonnell &
Miller, there is no warranty from McDonnell & Miller, but
McDonnell & Miller will extend to the buyer any Warranty
from McDonnell & Miller’s supplier of such products
Warranty Procedure
WARRANTY & RETURN
68
Date Codes
McDonnell & Miller controls manufactured after 1972 See chart for more specific information on maintenance
feature a stamped date code, so you can easily check the and replacement intervals. Below are guides to help you
life expectancy and recommended replacement intervals. quickly locate and translate the date code on McDonnell
If a control has no date stamp replace it! & Miller controls.
41 = 2014
51 = 2015
61 = 2016
71 = 2017 K21
81 = 2018 Translatesto
91 = 2019 October 2012
69
Recommended Maintenance
IMPORTANT
• Product repairs made with non-McDonnell & Miller manufacture.
parts will invalidate our warranty as well as any
• Use of water treatment can diminish product
agency recognitions. Without this recognition the
life. In such cases, components should be
product would no longer be eligible for use in listed
replaced on a more frequent basis.
end-use equipment.
• Visually inspect the inside of the float
• Previously used controls should never be
chamber during the annual inspection.
installed on a new system. Always install new
Partial disassembly may be required.
controls on a new boiler or system.
• A more frequent replacement interval may be
necessary based on the condition of the unit
at time of inspection. McDonnell & Miller’s
warranty is one (1) year from date of
installation or two (2) years from the
date of
Inspect all controls annually, and replace, repair or McDonnell & Miller products must also be maintained
clean, as needed. All chambered units are to be blown in accordance with the following ASME Code.
down per manufacturers instructions and local code
requirements. These requirements are to be determined
by the local service company, and are based on water
quality and system operation variables. Refer to the
installation instructions provided with the product for
specific assembly and test procedures.
70
Replacement Guidelines
Recommended
Replacement Intervals
Recommended
Replacement
Recommended Interval
Product Series Maintenance (Maximum)
1575, 150S, 157S, Blow down and test daily 15 years
158S, 159S inspect annually.
69, 169, 269, Inspect and test annually. 10 years
369, 469
67, 767 Blow down weekly. Inspect and 10 years
test annually.
61, 63, Blow down weekly. Inspect and 10 years
Low Water Cut-Offs 64, 764 test annually.
42S Blow down daily. Inspect and 10 years
test annually.
93, 94, Blow down and test daily. 15 years
193, 194 Inspect and test annually.
750, 751P/752P, PSE-800 Inspect and test annually. 15 years
RB-122E
RB-24E Inspect and test annually. 10 years
WFE/Uni-Match ®
Inspect and test annually. 10 years
21, 221, 25-A, 51-S, 53, Inspect and test annually. 15 years
Water Feeders
851-S, 3155
Inspect Annually
101-A, 47, 51, 247 Blow down weekly. Inspect and 10 years
847, 551-S, 851 replace cartridge valve annually.
PFC Inspect and test annually. 15 years
Liquid Level Controls Blow down weekly
27-W Inspect and test annually. 5 years
Replacement 14-B Inspect and test annually. 10 years
Blow Down Valves
Replacement 751P/752P, PSE-800 Self cleaning probes. 10 years
Probes RB-122E Inspect 5 years.
Replacement Head 25-A, 42S, 51, 51-S, Inspect and test annually. 5 years
Mechanisms for 53, 61, 63, 64, 67, 93
Commercial/Industrial 94, 150S, 157S,
Applications 193, 194
Inspect and test annually. 10 years
Flow Switches FS1, FS4-3, FS5,
FS43T, FS6, FS7-4,
REPLACEMENT GUIDELINES
71
Notes
notes
notes
notes
We’re a global team unified in a common purpose: creating advanced technology solutions to
the world’s water challenges. Developing new technologies that will improve the way water is
used, conserved, and re-used in the future is central to our work. Our products and services move,
treat, analyze, monitor and return water to the environment, in public utility, industrial, residential
and commercial building services, and agricultural settings. With its October 2016 acquisition of
Sensus, Xylem added smart metering, network technologies and advanced data analytics for water,
gas and electric utilities to its portfolio of solutions. In more than 150 countries, we have strong,
long-standing relationships with customers who know us for our powerful combination of leading
product brands and applications expertise with a strong focus on developing comprehensive,
sustainable solutions.
Xylem Inc.
8200 N. Austin Avenue
Morton Grove, Illinois 60053
Phone: (847) 966-3700
Fax: (847) 965-8379
www.mcdonnellmiller.com
McDonnell & Miller is a trademark of Xylem Inc. or one of its subsidiaries.
© 2017 Xylem Inc. MM-701E November 2017