HBX-120 PSC Series HBXX-120 ECM Series: Cooling or Heat Pump 1-1/2 - 5 Tons

Download as pdf or txt
Download as pdf or txt
You are on page 1of 4

HBX-120 PSC Series

HBXX-120 ECM Series


Vertical / Horizontal
Cooling or Heat pump
1-1/2 - 5 tons
Description :
The HBX(X) series air handler is designed to offer the industry an air handler that includes every available fea-
ture as well as up to 15 SEER when matched with today’s higher efficiency condensing units and heat pumps.
The HBX(X) is completely factory assembled with a cooling coil, 120V motor, 24V transformer, horizontal drain
pan, and throw away filter. All components are installed within a fully insulated, galvanized steel cabinet with an
attractive epoxy finish with 2% or less leak loss.
(1) First
Co's customer is ultimately responsible for confirming which fan coil models are compatible
with selected outdoor unit(s) and which expansion valves (if any) are required. To determine certified
indoor/outdoor matches, go to: www.firstco.com or contact the factory.

New Feature: Factory installed TXV kits (non-bleed type) for optimum cooling performance.

FEATURES:
1. 3-way airflow

2. Factory installed horizontal drain pan

3. Completely prewired with 0 electric heat

4. Compatible with major brands of split


condensing units and heat pumps
(Contact factory for correct match with outdoor
unit)

5. Cabinet air leakage is no more than 2%


when tested in accordance with
ASHRAE 193.16

6. Factory installed filter

7. Attractive baked on finish

8. Copper tube cooling coils

9. Primary and secondary drain connections on


cooling coil

10. Fully insulated and painted galvanized steel


cabinet

FIRST CO. - P.O. Box 270969 - Dallas, Texas 75227 - Ph. (214) 388-5751 - Fax (214) 388-2255 - www.firstco.com
HBX-120 PSC Series Cooling / Heat Pump

HBXX-120 ECM Series


Efficiency:
The HBX(X) series air handler is the latest state-of-the-art air handler for heat pump or straight cool
(DX) operation. Depending on the condensing unit or heat pump used, cooling efficiency is up to
15 SEER depending on the outdoor unit. Cooling coils have factory installed R410A TXV’s and are
circuited for cooling or heat pump operation.
First Co's customer is ultimately responsible for confirming which fan coil models are com-
patible with selected outdoor unit(s) and which expansion valves (if any) are required. To
determine certified indoor/outdoor matches, go to:

https://ratings.firstco.com/default.aspx or contact the factory.


Components:
Each air handler includes a high efficiency cooling coil, pre-wired, 120V fan motor, 24V transformer,
horizontal drain pan, and throw away filter.
Cabinets:
Cabinets are fully insulated and painted with an attractive, baked-on powder coating (light gray). Cabinet
air leakage is no more than 2% when tested in accordance with ASHRAE 193.16

Installation:
No modification is required for vertical or horizontal (right-to-left) airflow. A horizontal drain pan is factory
installed for right-to-left airflow and can be re-positioned within the cabinet to offer left-to-right airflow.
Accessories:
Accessories include cooling / heat pump R22 field mounted TXV kits. (P. 4)

3-WAY AIRFLOW

-2-
HBX-120 PSC Series
HBXX-120 ECM Series
C B
G 1“
24 VOLT J H

POWER
SUPPLY
HORIZONTAL
CONVERTIBLE
DRAIN PAN A

AIRFLOW

COOLING COIL
DIRECT EXPANSION

COIL
CONNECTIONS E F D
(ALL “SWEAT”)

PHYSICAL DIMENSIONS
UNIT LIQ. SUCT.
A B C D E F G H J FILTER
MODEL (SWEAT) (SWEAT)
18HBX(X)
40 20 20 18-1/2 16 2 18 16 3 3/8 5/8 18 X 20 X 1
24HBX(X)
30HBX(X)
42 23 20 21-1/2 16 2 18 17 5 3/8 3/4 20 X 22 X 1
36HBX(X)
48HBX(X)
48 28 21-1/4 26-1/4 17 2 19-1/4 18-1/4 8-7/8 1/2 7/8 20 X 25 X 1
60HBX(X)

All TXV's are approved for cooling only or heat pump operation (non-bleed type).
(X) = ECM motor

NOTE:
Expansion valve requirement depends on the selected outdoor unit. Go to www.firstco.com under ratings or contact
the factory for assistance.

-3-
ELECTRICAL AND CFM DATA

BLOWER DATA PSC Motor


Nom. MOTOR Max. CFM vs. EXTERNAL STATIC PRESSURE
UNIT Motor
Cooling HP FLA MCA Overload
MODEL Speed 0.1 0.2 0.3 0.4 0.5
tonage (120V) Protection
High 900 840 785 735 655
M. High 855 805 755 695 605
18HBX 1.5 1/3 4.1 6.0 15
M. low 800 755 710 650 560
Low 690 655 610 545 485
High 920 855 785 715 635
Med-HI 870 805 740 665 585
24HBX 1.5-2.0 1/3 4.1 6.0 15
Med-Low 795 725 665 605 530
Low 670 620 570 510 430
High 1485 1425 1360 1300 1225
30HBX 2.0-2.5 1/2 7.5 10 20 Medium 1405 1345 1285 1220 1160
Low 1270 1230 1180 1120 1040
High 1420 1360 1300 1240 1180
36HBX 2.5-3.0 1/2 7.5 10 20 Med-HI 1340 1280 1230 1175 1110
Low 1225 1180 1140 1080 1025
High 1820 1790 1750 1685 1620
48HBX 4-3.5 1 10.4 13 20 Medium 1460 1440 1405 1375 1330
Low 1180 1170 1155 1125 1095
High 1805 1760 1715 1650 1590
60HBX 4-5 1 10.4 13 20 Medium 1460 1440 1395 1355 1330
Low 1165 1140 1125 1105 1065

BLOWER DATA ECM motor


Max. CFM vs. EXTERNAL STATIC PRESSURE
UNIT MOTOR SPEED MOTOR
FLA MCA Overload
MODEL HP TAP BHP 0.10 0.20 0.30 0.40 0.50
Protection
3 0.16 835 805 775 735 685
18HBXX 1/3
1&2 0.10 655 630 590 545 505
4 0.19 4.8 6.0 15 945 875 800 730 640
24HBXX 1/3 3 0.16 790 755 715 680 620
1&2 0.11 625 575 540 485 450
3 0.22 1320 1285 1250 1220 1180
30HBXX 1/2
1&2 0.17 1135 1100 1055 1030 995
4 0.30 6.8 9.0 15 1375 1350 1330 1300 1275
36HBXX 1/2 3 0.23 1230 1205 1175 1145 1120
1&2 0.17 1075 1040 1010 975 945
4 0.52 1730 1700 1665 1630 1585
3 0.49 1685 1645 1600 1570 1525
48HBXX 1
2 0.35 1440 1385 1345 1305 1255
1 0.23 10.9 14.0 20 1170 1115 1060 1025 965
3 0.77 2015 1970 1935 1900 1865
60HBXX 1 2 0.63 1870 1835 1790 1760 1715
1 0.48 1655 1615 1575 1540 1495

NOTE: Use 48HBX for 3.5 ton applications and field convert to medium speed for cooling.

ACCESSORIES - (all field installed)


EXPANSION VALVE KITS for R22
(Field installed) (cooling only or heat pump)
R22
9EVR22-4 18/24HBX
9EVR22-5 30/36HBX
9EVR22-6 48/60HBX

NOTES:
1. Above expansion valve kits are approved for
both cooling only (non heat pump) and heat In keeping with its policy of continuous progress and product
pump applications. improvement, First Co. reserves the right to make changes
2. Valves are non-bleed type. Field added. Hard without notice. Maintenance for all First Co. products is
start kit may be required.
3. Valves have screw-on connections.
available under “Product Maintenance” at www.firstco.com.

Catalog HBX-120-1119
-4-