RM3545 RM3544 Ds
RM3545 RM3544 Ds
RM3545 RM3544 Ds
RM3545 RM3544
Super-high accuracy
and multi-channel capabilities High-precision bench-top meter
for advanced development for both manual operation
and production applications and integration with automatic lines
Resistance measurement
Basic accuracy : 0.006% Max. resolution : 0.01μΩ Basic accuracy : 0.02% Max. resolution : 1μΩ
Max. measurable current : 1A Max. measurable current : 300mA
Applications
Small-signal contacts Motors, solenoids, choke coils, transformers,
RM3545
wire harnesses
RM3545 RM3544
General specifications
RESISTANCE METER RM3545 RESISTANCE METER RM3544
0.00µΩ to 1200MΩ Measurement types (4-terminal direct current) 0.000 mΩ to 3.5 MΩ
Temperature measurement, Temperature correction (TC),
3 3
comparator, judgment sound setting, auto hold
3 Low power resistance measurement (LP) N/A
3 Temperature rise (Temperature conversion (∆T) N/A
3 Offset voltage compensation (OVC) N/A
3 D /A output N/A
3 RM3545-02 : Max. 20ch Multiplexer N/A
3
Application 1. Application 2.
Measuring a 3-phase motor winding Testing a connector or wiring harness
TERM1 (SOURCE)
Resolver TERM1 (SENSE)
detection SOURCE2 TERM2 (SOURCE)
SENSE2 TERM2 (SENSE)
Stator SOURCE3
Resolver
Application 3. Application 4.
Testing a relay Testing battery terminal welds
TERM1 (SOURCE)
TERM1 (SENSE)
TERM2 (SOURCE) TERM1 (SOURCE)
TERM2 (SOURCE)
TERM2 (SENSE) TERM1 (SENSE) TERM2 (SENSE)
TERM3 (SOURCE)
TERM3 (SOURCE) TERM2 (SOURCE) TERM3 (SENSE)
TERM3 (SENSE) TERM2 (SENSE)
TERM4 (SOURCE)
TERM4 (SENSE)
CLIP TYPE LEAD L2101 PIN TYPE LEAD PIN TYPE LEAD 4 -TERMINAL LEAD
(Bundled accessory) L2102 L2103 L2104
The RM3545 can perform resistance measurement with a 6.5-digit, As inverter-equipped power supply equipment uses increasingly high cur-
1,200,000-count display at a maximum resolution of 0.01 μΩ. It delivers rents and frequencies, increasingly low-resistance and low-loss inductors
more than enough capabilities to be used in applications requiring high- are being incorporated in their circuitry, prompting a need for the ability to
resolution resistance measurement, for example in testing inverter motor measure lower resistance levels with a high level of stability. With a resolu-
windings. tion of 1 μΩ, the RM3544/RM3544 -01 satisfy these needs.
High-resistance materials such as conductive sheets and conductive rub- Electronic components make extensive use of high-resistance substrates
ber are often used in electronic components. The RM3545 can measure such as conductive sheets and rubber, and the RM3544/RM3544 -01 deliver
resistance values of up to 1,200 MΩ. It also delivers maximum accuracy of the ability to measure up to 3.5 MΩ.
0.006%, enabling researchers to test state-of-the-art current sensing resis- Moreover, the instruments’ maximum accuracy of 0.02% allows them to be
tors. used in testing current detectors with a precision of 0.1%.
D/A output
The RM3545 converts resistance measured values into DC voltage
for output. This capability is convenient when continuously recording
changes in resistance, for example as detected by a sensor, with a logger
or other piece of equipment.
RM3545
R
RM3545 Time
High/low current selection by range
Select the optimal measurement current by switching between high and Logger
low settings according to the characteristics of the sample.
7 Scaling
The scaling function can be used to convert resistance values into physical
properties such as length.
3 4 Conversion formula : Rs = A × R + B
A, B : Constants, R : Measurement value
Rs : Resistance value
3 LED COMPARATOR ATTACHMENT (Option)
The LED Comparator Attachment 5 6 7
indicates judgment results with
green and red LEDs, eliminating
the need to look at the instrument’s
screen and increasing work effi -
ciency. Since the lamps do not light
up when the measurement leads are
open, the attachment can also be Green light Red light
used to verify the connection status. IN state HI/LO state
RM3544
7
High-speed, comprehensive
productivity support
• The RM3545 and RM3544 -01 deliver the speed demanded by automatic • The RM3545 and RM3544 -01 support RS-232C data communications at
testing equipment at a sophisticated level. The entire process from the up to 115.2 kbps*.
start of measurement to outputting of the judgment result takes as little • The EXT I/O output mode can be switched between judgment mode and
as 1.9ms (RM3545) and 18 ms (RM3544 -01). One cycle of operation, BCD mode.
lasting from measurement to judgment output, completes within this *
With some computers, large error components may prevent fast transfer speeds (baud
time. rates) from being used. In this case, change the speed to a lower setting.
• The instrument’s USB interface can also be used.
Handler (EXT I/O) interface When designing a control system using the
The handler interface (EXT I/O) is isolated from measurement circuitry, control EXT I/O interface, be sure to read
circuitry, and the protective ground (chassis ground), providing a high level of the instruction manual and check the neces-
noise resistance. sary technical information.
EXT I/O Input and Output Circuits EXT I/O Electrical Specifications
A switch on the rear panel is used to toggle the input signal polar-
Inputs :
ity between NPN (sink output support) and PNP (source output
support) settings depending on the PLC common polarity. Photocoupler isolation: Non-voltage contact inputs
EXT I/O polarity
(support for current sink output)
(Select NPN/PNP) Input ON: Residual voltage: Max. 1 V @4 mA
Input OFF: Open Max. 100 μA
Input Circuit (when using NPN) Output Circuit
RM3545/-01/-02 Outputs :
RM3545/-01/-02 RM3544-01
2kΩ RM3544-01 Photocoupler-isolated open drain output (no-polarity)
10Ω Output
DC30Vmax, DC50mAmax/ch
1kΩ Input Residual voltage: Max. 1 V @50 mA, or 0.5 V @10 mA
Max. 50 mA DC
PNP
Zener voltage External power output :
= 30 V
ISO_COM Output voltage: Sink output support: 5.0V±10%,
ISO_COM
EXT I/O Source output support: -5.0V±10%
MODE NPN
Internally Isolated Max. output current: 100mA
SELECTOR Internally Isolated
Common Common
USB
EXT I/O Protective fuse
Protective for measurement
fuse for circuitry
measurement
circuitry
Maintenance jack for HIOKI use only USB Temperature sensor jack
RS-232C/ D/A output Temperature EXT I/O polarity (This jack is provided for maintenance
PRINTER terminals sensor jack (Select NPN/PNP) use. It cannot be used by the customer.)
*Multiplexer Units cannot be installed in the RM3545 or RM3545-01. The *The RM3544 does not include EXT I/O or communication interfaces
RM3545-01 has a GP-IB connector. (RS-232C or USB). Select the RM3544 -01 for these functions.
RM3545 series comparison chart (Base model) -01 -02 RM3544 series comparison chart (Base model) -01
External I/O External I/O
3 3 3 N/A 3
(comparator, BCD, BIN function) (comparator, BCD)
Communication RS-232C/Printer/USB 3 3 3 Communication interfaces
N/A 3
interfaces GP-IB N/A 3 N/A RS-232C/Printer/USB
Multiplexer* (scanner function) N/A N/A 3 (Max. 20 channels)
*When using 4-terminal measurement with two MULTIPLEXER UNIT Z3003 (option) cards.
RM3545 RM3544
Resistance measurement: 0.000 00mΩ (10mΩ range) to
1200.0MΩ (1000MΩ range), 12 ranges
Resistance measurement: 0.000mΩ (30mΩ range) to
Low power resistance measurement: 0.00mΩ (1000mΩ range) to
Measurement types 3.500 0MΩ (3MΩ range), 9 ranges
1200.00Ω (1000Ω range), 4 ranges
Temperature measurement (thermistor): -10.0 to 99.9°C
Temperature measurement (thermistor): -10.0 to 99.9°C
Temperature measurement (analog input): -99.9 to 999.9°C
Measurement method 4-terminal direct current (constant current), banana plug, with guard terminal
Range switching Auto or Manual
Reference temperature setting range: -10°C to 99.9°C, Reference temperature setting range: -10°C to 99.9°C,
Temperature correction
Temperature coefficient setting range: -99,999 ppm/°C to 99,999 ppm/°C Temperature coefficient setting range: -9,999 ppm/°C to 9,999 ppm/°C
By range, by step (RM3545-02 only)
Zero-adjustment Within ±50% f.s. of each range. (Zero-adjustment is not required Within -3% to 50% f.s. of each range. (f.s.= 30,000 dgt.)
for 100 MΩ or greater ranges.)
Trigger Internal or external RM3544: Internal trigger, RM3544 -01: Internal or external
Measurement speed FAST / MED / SLOW1 / SLOW2 FAST / MED / SLOW
Delay Internal fixed value: / 0 to 9999 ms (1ms step) N/A
Temperature correction, Temperature conversion, Self-calibra-
Temperature correction, comparator (ABS/REF%), key-
tion, offset voltage compensation (OVC), comparator (ABS/
lock (OFF, menu lock, all lock), display digit count selec-
REF%), BIN, key-lock (OFF, menu lock, all lock), display digit
tion function (5 digits/4 digits), automatic power supply
Functions count selection function (7 digits/6 digits/5 digits), automatic
frequency settings (AUTO/50Hz/60Hz), scaling, judgment
power supply frequency settings (AUTO/50Hz/60Hz), scaling,
sound setting, auto hold, L2105 LED Comparater Attach-
judgment sound setting, auto hold, statistical calculations, clock,
ment output
self-test, L2105 LED Comparater Attachment output
Measurement fault
Contact check, over detection, current fault detection Over detection, current fault detection
detection functions
Averaging OFF, 2 to 100 averaging iterations (variable in 1-iteration steps)
30 (Front terminals), 8 (MUX (multiplexer)) 10
Panel store, Panel save parameters: save time and date, resistance measure-
Panel save parameters: resistance measurement ranges,
panel load ment ranges, measurement speed, comparator, BIN setting, mul-
measurement speed, comparator, etc.
tiplexer setting, etc.
RM3545-02:
Number of installed units: Max. 2
Measurement terminal settings : Front terminals / MUX
(multiplexer)
Multiplexer When using the MUX setting, the measurement leads cannot N/A
be connected to the front measurement terminals
Support unit: Z3003
Number of channels that can be set: 42, switching time 30
ms (reference value)
Output: resistance measured value
Output voltage: 0V DC to 1.5V DC
D/A output N/A
Output impedance: 1kΩ
Number of bits: 12bit
EXT I/O TRIG and other, BIN, BCD RM3544 -01 : TRIG and other, BCD
Communication Select from GP-IB*, RS-232C, PRINTER(RS-232C), or USB RM3544 -01:
interfaces *
RM3545-01 only Select from RS-232C, PRINTER(RS-232C), or USB
Communication Remote function, communications monitor function, data output Remote function, communications monitor function, data
interfaces function, memory (50 data) output function
RS-232C Bit rates: 115,200 / 38,400 / 19,200 / 9,600 bps
USB Class: CDC (COM mode), HID (USB keyboard mode)
Printed data: Resistance measurement values, temperature mea- Printed data: Resistance measurement values, temperature
surement values, judgment results, measurement conditions, sta- measurement values, judgment results, measurement con-
Printer tistical results ditions
(RS-232 port)
Operation: Prints at PRINT signal or PRINT key input.
Interval: ON/OFF, Interval times: 1 to 3,600 s (variable in 1 s steps), Number of print columns per row: 1 or 3
Operating temperature
0 to 40ºC, 80% rh or less (non-condensating)
and humidity
Storage temperature
–10 to 50ºC, 80% rh or less (non-condensating)
and humidity
Operating environment Indoors, Pollution Degree 2, up to 2,000 m ASL
Power supply Rated supply voltage: 100 to 240 VAC ±10%, Rated supply frequency: 50/60 Hz
Rated power consumption 40 VA 15 VA
Insulation withstand 1.62 kV AC for 1 min. (with 10 mA cutoff current),
potential between all mains supply terminals and protective ground, interfaces, and measurement terminals
Approx. 215W × 80H × 306.5D mm (8.46”W × 3.15”H × Approx. 215W × 80H × 166D mm (8.46”W × 3.15”H ×
Dimensions
12.07”D) (without projections) 6.54”D) (without projections)
RM3545, RM3545-01: Approx. 2.5 kg (88.2 oz) RM3544: Approx. 0.9 kg (31.7 oz)
Mass
RM3545-02:Approx. 3.2 kg (112.9 oz) (not including Z3003) RM3544 -01:Approx. 1.0 kg (35.3 oz)
Power cord ×1, CLIP TYPE LEAD L2101 ×1, male EXT
Power cord ×1, CLIP TYPE LEAD L2101 ×1, temperature
I/O connector* ×1, instruction manual ×1, application disc*
Accessories sensor Z2001 ×1, male EXT I/O connector ×1, instruction manu-
×1, USB cable (A-to-B type)* ×1, extra fuse ×1
al ×1, application disc ×1, USB cable (A-to-B type) ×1, extra fuse ×1 *
Included with RM3544 -01.
Applicable standards Safety: EN61010, EMC: EN61326, EN61000-3-2, EN61000-3-3
10
RM3544 RM3544
Accuracy = ±(% rdg. + % f.s.)
• f.s. = calculated 30,000 dgt., where 0.010% f.s. = 3 dgt. (Example) 0.020 + 0.007 ....... 0.020% rdg. + 0.007% f.s.
Measurement speed typical values (RM3545) RM3545 Measurement time (RM3544) RM3544
Measurement speed (ms) Measurement speed (ms)
Measurement
Range MED FAST
current FAST SLOW1 SLOW2 MED SLOW
50Hz 60Hz 50Hz 60Hz
10 mΩ N/A 41 61 58 141 241 21 18 101 401
100 mΩ High 41 61 58 141 241
1000 mΩ High 2.2 22 19 102 202 Tolerance: ±10% ±2 ms
10 Ω High 2.2 22 19 102 202 * With TC set to ON and the comparator set to ON
100 Ω High 2.8 23 20 103 203
Tolerance: ±10% ±0.2 ms
* Shortest time when using an external trigger source or with continuous mea-
surement off (other than free-run). With a delay of 10 ms, TC on, comparator
on, OVC off, and averaging off. Measurement speed varies with the selected
range and settings. For more information, please see the Instruction Manual.
Model Configurations and Options
Options
Multiplexer Unit (for RM3545 -02 ) Test Leads
LED COMPARATOR PIN TYPE LEAD L2102 PIN TYPE LEAD L2103
GP-IB CONNECTOR CABLE 9151-02 B: 140 mm (5.51 in), L: 1.5 m (4.92 ft) B: 138 mm (5.43 in), L: 1.5 m (4.92 ft)
ATTACHMENT L2105 2 m (6.56 ft)
2 m (6.56 ft)
Note: Company names and Product names appearing in this catalog are trademarks or registered trademarks of various companies.