Fuel Optimized: Specification Sheet
Fuel Optimized: Specification Sheet
X3.3-G2
Fuel Optimized
Description Features
The X3.3 has all the strength and reliability the MICO direct injection in-line pump for cleaner,
genset industry has come to expect from the X more efficient fuel consumption.
Series range but in a smaller, lighter and more
Parent bore block with deep, stiff crankcase and
economical package. The X3.3 features direct
optimised rib arrangement to enhance strength
fuel injection, resulting in cleaner, quieter and
and reduce noise.
more fuel-efficient performance. With a highly
compact 4-cylinder envelope and extremely low 12-volt electrics package, with starter, alternator
heat rejection, the engine offers a high degree and fuel solenoid.
of installation flexibility.
Shallow oil pan and single spin-on oil and Fuel
Filter
SAE ‘3/11.5’ flywheel housing
Integrated Design - CoolPac products are
supplied fitted with cooling package and air
cleaner for a complete power package. Each
component has been specifically developed and
rigorously tested for G-Drive products, ensuring
high performance, durability and reliability.
Service and Support - G-Drive products are
backed by an uncompromising level of technical
support and after sales service, delivered
through a world class service network.
cummins.com
©2021 Cummins Inc. | X3.3-G2 (08/21)
1800 rpm (60 Hz Ratings)
Gross engine output Net engine output Typical generator set output
Standby Prime Base Standby Prime Base Standby (ESP) Prime (PRP) Base (COP)
kWm/BHP kWm/BHP kWe kVA kWe kVA kWe kVA
42/56 36/48 29/39 40/54 35/47 28/38 36 45 32 40 25 31
cummins.com
©2021 Cummins Inc. | X3.3-G2 (08/21)
*Drawing for illustration purposes only.
Ratings Definitions
Emergency Standby Limited-Time Running Prime Power (PRP): Base Load (Continuous)
Power (ESP): Power (LTP): Power (COP):
Applicable for supplying Applicable for supplying Applicable for supplying Applicable for supplying
power to varying electrical power to a constant power to varying electrical power continuously to a
load for the duration of electrical load for limited load for unlimited hours. constant electrical load for
power interruption of a hours. Limited-Time Prime Power (PRP) is in unlimited hours. Continuous
reliable utility source. Running Power (LTP) is in accordance with ISO 8528. Power (COP) in accordance
Emergency Standby Power accordance with ISO 8528. Ten percent overload with ISO 8528, ISO 3046,
(ESP) is in accordance with capability is available in AS 2789, DIN6271 and
ISO 8528. Fuel Stop power accordance with ISO 3046, BS 5514.
in accordance with AS 2789, DIN 6271 and
ISO 3046, AS 2789, BS 5514.
DIN 6271 and BS 5514.
©2021 Cummins Inc. All rights reserved. Cummins is a registered trademark of Cummins Inc. PowerCommand, AmpSentry, InPower and “Our energy working for you.” are trademarks of
Cummins Inc. Other company, product, or service names may be trademarks or service marks of others. Specifications are subject to change without notice.
X3.3-G2 PD00000509 (08/21)