KPX-K20P (V2203-BG)

Generating set Technical Data Sheet

FUZHOU GFF KEYPOWER EQUIPMENT CO., LTD


Add: No. 760 Qian Rd. Fuwan Industrial Zone Fuzhou, China 350006
http://www.gff-keypower.com
info@keypower.biz , sales@keypower.biz
Tel:(0086)-591-83568232 Fax:(0086)-591-83568345
Powered by V2203-BG
KUBOTA Engine Generating Set

STANDARD SPECIFICATION
General features:
● Composed of Kubota diesel engine and Stamford
alternator or Leroy Somer or Copy Stamford alternator
● 12V DC start motor and storage battery
● Brushless, Self-excited, IP23, insulation class H alternator
● 55℃ tropical radiator as standard
● Key start panel control system as standard, digital auto-start
panel is optional
● 8-hour operation fuel tank
● Optional open type or silent type
● All generator sets are gone through rigorous testing before
being released to the market place, including 50% load,
75% load, 100% load , 110% load and all protection function
(overspeed stop, high water temperature, low oil pr essure,
battery charging fail, emergency stop)

Genset Main Technical Data


3P4W, 60Hz, 127/220V (Can Be Made According To Customers’ Special Requirements)

Genset Specification Engine Specification


KVA Stamford
GENSET Cons
dB(A) Tank Kubota alternator
MODEL 100% Cyl. Gov. Asp.
ESP PRP @7m (L) engine model model
(L/H)
KPX-K20P 22 20 5.79 68 55 V2203-BG 4 M NA PI044H
KPX-K22S 22 20 5.79 68 55 V2203-BG 4 M NA PI044H

1) Available in various voltages


2) To show KEYPOWER Generating Sets Model
KPX-K20P, it is the Prime power 20kva generation set.
KPX-K22S, it is the Standby power 22kva generating set.
3) ESP=Standby power standby duty, operation under variable load, without overload.
PRP=Prime power continuous duty operation, under variable load, 10% overload permissible 1/12hr.
4) E=Electronic speed governor;
M=Mechanical speed governor
5) Asp=Aspiration;
NA=Naturally Asp;
TC=Turbocharged;
TW=Turbocharged after cooled;
TCA= Turboc harged air-air after cooled
6) Technical data is subject to work test conditions

http://www.gff-keypower.com Page: 2/5 Specifications may change without Notice


Powered by V2203-BG
KUBOTA Engine Generating Set

Reliable Performance

Voltage regulation
Voltage regulation maintained within ±0.5% as follow:
● Power factor Between 0.8~1.0 lag
● From no load to full load, any steady load
● Speed droop variation under 4.5%
Frequency/Speed undulation
● Change load from 0-100%, Frequency/Speed Droop Ratio within 5%.
● Load from 25-100%, any steady load Frequency/Speed undulation within 0.25%

Effect factor of telecom


● TIF( MA MG1-22) better than 50
● THF( BS EN60034) better than 2%

Criterion

● ISO8528, GB/T2820
● EN12601:2001, EN60034-22:1997, EN60204-1:2006
● ISO9001:2000 Quality Control System

Dimension and Weight

Open Type
Overall size (L*W*H)
1650*680*1000
Weight: 550kg

Silent Type
Overall size (L*W*H)
1950*850*950
Weight: 750kg

http://www.gff-keypower.com Page: 3/5 Specifications may change without Notice


Powered by V2203-BG
KUBOTA Engine Generating Set

ENGINE SPECIFICATION
Kubota Diesel Engine
Technical Data

Engine Model V2203-BG


Number of Cylinders 4
Cylinder arrangement Vertical in-line
Cycle Four stroke
Aspiration Naturally Aspirated
Bore×Stroke (mm×mm) 87*92.4
Displacement (Liter) 2.197
Compression Ratio 23:1
Prime Power/Speed (kW/rpm) 20.2/1800RPM
Standby Power/Speed (kW/rpm) 24.2/1800RPM
Speed Governor Mechanical

Cooling System Water-cooled, 55℃ Tropical Radiator.

Speed Stability (%) ≤5%


Total lubrication system capacity (L) 7.6
Coolant capacity (without radiator) (L) 8.0
Fuel Consumption at 100% Load (L/H) 5.79
Starter Motor DC12V
Start type Electrical

Alternator Specification

Stamford Alternator (Standard)


Leroy Somer and Copy Stamford Alternator (Optional)
Technical Data

Alternator Model Stamford PI044H

Exciter type Brushless, Self-excited

Power factor 0.8

Voltage Adjust range ≥5%

Voltage Regulation NL-FL ≤±0.5%

Insulation Grade H

Protection Grade IP23

http://www.gff-keypower.com Page: 4/5 Specifications may change without Notice


Powered by V2203-BG
KUBOTA Engine Generating Set

Control System

1. Standard: Deepsea DSE7320 AMF Digital Controller


Providing the standard functions as follows:
(Also can be made according to the customers' special requirements)
*Automatic Start/Stop
*Settings can be adjustable via key buttons on front panel
*3 start attempts failure and Automatic Crank Disconnect
*Parameters display (V/A/Hz/Hour)
*Engine monitoring and protection
*Charge alter nator exciting and Charge alternator fail alarm
*Running hour counting (1) DSE7320
*Emergency stop pushbutton
*Alarm System: Over speed, High Engine Temperature,
Low Oil Pressure, Charge Fail
*Protection System: Over speed, High Engine Temperature, Low Oil
Pressure , Emergency Stop. And the other protection function
pre-setting

Digital Auto-start Generator controller integrating digital, intelligent


and network techniques is used for automatic control system of diese l
generator. It can carry out functions including automatic start/stop, data
measure and alarming. Optionally assembled with the ATS, it can carry (2) GU641B
out auto-switching between the outer power and generating set power.
(AMF)

2. Option: Harsen GU641B AMF Digital Auto Start


3. Option: ComAp AMF25 Digital Auto Start
4. Option: Deepsea DSE3110 Digital Auto Start

(3) AMF25

(4) DSE3110

http://www.gff-keypower.com Page: 5/5 Specifications may change without Notice

You might also like