Column Base Plate: There Are Three Type of Column Base Plate Divided Inti The Load Condition Applied
Column Base Plate: There Are Three Type of Column Base Plate Divided Inti The Load Condition Applied
Column Base Plate: There Are Three Type of Column Base Plate Divided Inti The Load Condition Applied
Mahmoud
Civil Engineering Fourth stage
The thickness of base plates varies from (1⁄2'' to 6'') and they are more commonly available
in ASTM A36 steel.
The base plate is usually larger than the column size (depending on the shape of the column)
by as much as 2'' to 4'', in order to provide a drill hole for the anchor bolt holes outside of
the column outline and it's usually connected to the column with fillet weld (up to 3/4'' in
size) on both side of the web and flange and usually shop welded.
There are three type of column base plate divided inti the load condition applied
θ=0.65 (LRFD)
Ω =2.31 (ASD)
A1
1- The nominal bearing strength, Pp, is determined as follows:
(a) On the full area of a concrete support: A2
A1= A2
Pp =0.85 f′c A1
A2>A1
A2 A1
Pp =0.85 f′c A1 √A ≤1.7f'c A1
1
A2
A 2≤ 4 A1
Where:-
𝐹′𝑐 = the 28 day comp. strength of the concrete. (ksi)
A1 = area of steel concentrically bearing on a concrete support (B x N), in2. Footing Area (A2)
A2 =maximum area of the portion of the supporting surface that is
Effective area
geometrically similar to and concentric with the loaded area, in.2
A1
A2
1≤√ ≤ 2
A1
A1= N x B
A-model (1): The load is transfer into equivalent area equal to (0. 8bfx0. 95d)
𝑁−0.95𝑑
𝑚= 2
𝐵−0.8𝑏𝑓
𝑛= 2
B-model (2): The load is transfer into equivalent distance equal to (𝛌𝐧′)
√𝑑𝑏𝑓
𝑛′ = 4
2√𝑥
λ = 1+ 1−𝑥 ≤ 1
√
4𝑑𝑏𝑓 𝑃𝑢
𝑋 = [(𝑑+ 𝑏𝑓)2 ]𝜃𝑐𝑃𝑝 θc=0.65 LRFD
4𝑑𝑏𝑓 𝑃𝑎𝛺𝑐
𝑋 == [ ] Ωc=2.31 ASD
(𝑑+ 𝑏𝑓)2 𝑃𝑝
Note: for W shape the value of λ is always greater than (1 then use λ=1 ) Model 1
Now take the larger value from the three values:- λ𝑛′
m
λ𝑛′
n take the larger value (ℓ)
λn′ λ𝑛 ′ λ𝑛
Model 2
Design of Steel Structure Column Base Plate Dr. Kamal Sh. Mahmoud
Civil Engineering Fourth stage
∑M@A=0 w
𝑤 ℓ2
𝑀𝑎𝑝𝑝𝑙𝑖𝑒𝑑 = 2
A
ℓ (Max. value)
𝑃𝑢 𝑃𝑢
𝑤𝑢 = = (𝐿𝑅𝐹𝐷)
𝐴 𝐵𝑥𝑁
𝑃𝑎 𝑃𝑎
𝑤𝑎 = = (𝐴𝑆𝐷)
𝐴 𝐵𝑥𝑁
Mp= Fy x Z
Where:
Ω = 1.67 ASD b
𝑏𝑥𝑑2
Z= t
4
𝑏𝑥𝑡 2
Z=
4
𝑏𝑥𝑡 2
𝜃𝑀𝑝 = 𝑥0.9 𝑓𝑦 (𝐿𝑅𝐹𝐷)
4
𝑀𝑝 𝑏𝑥𝑡 2 𝑓𝑦
= 𝑥 (𝐴𝑆𝐷)
𝛺 4 1.67
M applied =M resisting
2
𝑃𝑢 ℓ 𝑏𝑥𝑡𝑝2
= 𝑥0.9 𝑓𝑦 𝐿𝑅𝐹𝐷
𝐵𝑥𝑁𝑥 2 4
2
𝑃𝑢 ℓ 𝑏𝑥𝑡𝑝2 𝑓𝑦
= 𝐴𝑆𝐷
𝐵𝑥𝑁𝑥 2 4 𝛺
2𝛺𝑃𝑎ℓ2 2𝑥1.67𝑃𝑎 3.333𝑃𝑎
𝑡𝑝 = √ 𝑓𝑦 𝐵𝑁 = ℓ√ 𝑓𝑦𝐵𝑁
= ℓ√ 𝑓𝑦𝐵𝑁
𝐴𝑆𝐷
Design of Steel Structure Column Base Plate Dr. Kamal Sh. Mahmoud
Civil Engineering Fourth stage
General Design Procedure for column base plate under axil load
0.95𝑑−0.8𝑏𝑓 0.95𝑑−0.8𝑏𝑓
-Δ= 2
- - Δ= 2
-Find the base plate dimension -Find the base plate dimension
𝑁 = √A1 + Δ ≥ d+(2''to 3'') 𝑁 = √A1 + Δ ≥ d+ (2''to 3'')
A1 A1
𝐵 = 𝑁 ≥ bf + (2''to 3'') 𝐵 = 𝑁 ≥ bf + (2''to 3'')
A1=N x B A1=N x B
6- Check the bearing stress 6- Check the bearing stress
A2 Pp 0.85f′ c A A2 1.7f′c A
θPp =θ 0.85 f′c A1 √ ≤ θ1.7f' c A1 √ ≤
1 1
=
A1 𝛺 𝛺 A1 𝛺
Pp
θPp ≥ Pu ….. OK
𝛺
≥ Pa …..OK
if not increase A1(Area of base plate) if not increase A1(Area of base plate)
7- Find the thickness of Base Plate 7- Find the thickness of Base Plate
𝑁−0.95𝑑 𝑁−0.95𝑑
𝑚= 2
𝑚= 2
𝐵−0.8𝑏𝑓 𝐵−0.8𝑏𝑓
𝑛= Take the larger value (ℓ) 𝑛= Take the larger value (ℓ)
2 2
√𝑑𝑏𝑓 √𝑑𝑏𝑓
λ𝑛′ = 4 λ𝑛′ = 4
2√𝑥
λ = 1+ 1−𝑥 ≤ 1 For W shape λ > 𝟏 2√𝑥 For W shape λ > 𝟏
√ λ= ≤ 1 Use λ = 𝟏
Use λ = 𝟏 1 + √1 − 𝑥
2.222𝑃𝑢
𝑡𝑝 = ℓ√ 3.333𝑃𝑢
𝑓𝑦𝐵𝑁 𝑡𝑝 = ℓ√
𝑓𝑦𝐵𝑁
Example
Design an A36 base plate for W12x65 which that supports a service dead load (Pd.l =200 kips)
and service live load (Pl.l =300 kips). The concrete has compressive strength (3ksi), the
footing area has dimension (9x9) ft., used LRFD design method
Solution
Steel fy fu
W12x65
A36 36 58
Section bf d
W12x65 12 12.1 A1 ?
Pu=1.2x200+1.6x300= 720 kips
𝑃𝑢 A2(9'x9')
A1= -
𝐴2
𝜃0.85𝑓𝑐√
𝐴1
A2
1≤√ ≤2
A1
A2
Max. Effective value A2= 4A1 then √A = 2 1
720
A1= 0.65𝑥0.85𝑥3𝑥2 = 217.195 𝑖𝑛2 Control A1=217.195 𝑖𝑛2
Amin = 12x12.1= 145.2 𝑖𝑛2
(9𝑥12𝑥9𝑥12)
θPp =0.65x 0.85 x3𝑥 224 √ 224
≤ 0.65x1.7x3x224
=2679.176 ≤ 742.56
Use θPp=742.56 kips≥ Pu (720 kips) OK
Example
Find the Max. Allowable load that can be applied on the design shown below use 𝑓′𝑐 =
3000𝑝𝑠𝑖, A36 steel material for base plate and A992 for column use LRFD method if (kly=10
ft., section W10x60, A1 (3/4''x14''x14'') and A2 (5'x5')
Solution
W10x60
Steel fy fu
A36 36 58 for base plate
A1 (3/4''x14''x14)
A992 50 65 for column
Section bf d
W10x60 10.1 10.2 A2A 2 (5'x5')
(9'x9'
) 𝒇′𝒄 = 𝟑𝟎𝟎𝟎𝑷𝒔𝒊
1-From column
Kly =10
Section W10x60 Go to table (4-1) and find θPn=677 kips
Fy= 50
2.222𝑃𝑢
𝑡𝑝 = ℓ√
𝑓𝑦𝐵𝑁
3 2.222𝑥𝑃𝑢
= 2.96𝑥√ = 𝑃𝑢 = 204 kips
4 36𝑥14𝑥14
Max. Allowable load that can be applied on this design is (Pu=204 kips)
Design of Steel Structure Column Base Plate Dr. Kamal Sh. Mahmoud
Civil Engineering Fourth stage
Example
Check the adequacy of A36 steel material for base plate (1''x14''x14'') on footing area
(38''x38'') to support a service dead load (Pd.l =100 kips) and service live load (Pl.l =250 kips).
The concrete has compressive strength (𝑓′𝑐 = 3.5𝑘𝑠𝑖), used LRFD design method
Solution
Steel fy fu W12x65
A36 36 58
Section bf d
A1 (1'x14''x14)
W12x65 12.1 12
)
f'c=3.5 ksi
38′′ 𝑥38′′
θPp =0.65x 0.85𝑥 3.5 x14x14 √ 14x14
≤ 0.65x1.7x3.5 x14x14
=1028.7> 758
θPp=758 kips >520 ok
𝑁−0.95𝑑 14−0.95𝑥12.1
𝑚 = 2
= 2
= 1.25255′′
𝐵−0.8𝑏𝑓 14−0.8𝑥12
𝑛= 2
= 2
= 2.2′′
Take the larger value (ℓ) =3.012''
√𝑑𝑏𝑓
λ𝑛′ = λ , λ = 1 (W shape)
4
√12.1𝑥12
λ𝑛′ = 1𝑥 = 3.012 ′′
4
2.222𝑃𝑢
𝑡𝑝 = ℓ√
𝑓𝑦𝐵𝑁
2.222𝑥𝑃𝑢
1 = 3.012√ = 𝑃𝑢 = 350.23kips < 520 𝑛𝑜𝑡 𝑜𝑘
36𝑥14𝑥14
Example
For HSS 12"x12"x1/2" column carry a service dead load 50 kips and service live load 225 if
the base plate (16"x 16"). Determine the minimum pier size and thickness of base plate, the
compressive strength for concrete pier is 𝑓′𝑐 = 3𝑘𝑠𝑖 use ASD method?
Pp 0.85 f′c A1
=
𝛺 𝛺
Pp 0.85 x3x16x16
𝛺
= 2.31
= 282.59 𝑘𝑖𝑝𝑠
3.333𝑥275
𝑡𝑝 = 3𝑥√ = 0.946 = 1′′
36𝑥16𝑥16
Note: for estimate the thickness of base plate for HSS Section
𝑁−𝑜𝑢𝑡 𝑠𝑖𝑑𝑒 𝑑𝑖𝑚𝑒𝑛𝑠𝑖𝑜𝑛(ℎ)
𝑚 =
2
Take the larger value (ℓ)
𝐵−𝑜𝑢𝑡 𝑠𝑖𝑑𝑒 𝑑𝑖𝑚𝑒𝑛𝑠𝑖𝑜𝑛(𝑏)
𝑛 =
2
√𝑏ℎ
𝑛′ =
4
Design of Steel Structure Column Base Plate Dr. Kamal Sh. Mahmoud
Civil Engineering Fourth stage
Homework
1- A 36 base plate is to be design, for a W12x152 column which that support a service dead
load (Pd.l =200 kips) and service live load (Pl.l =450 kips). The concrete has compressive
strength (3ksi), the base plate cover the entire area of footing, used LRFD design method
2-Design a base plate and select the minimum concrete pier size for a W12 x58 with a
factored axial compression load of 300 kips. Assume a 1 in. grout thickness, concrete
compressive strength of 4 ksi, and ASTM A36 steel for the steel plate
3-Design a base plate for an HSS 12’’ x12’’x1/2’’ column with a factored axial compression
load of 450 kips. Assume a 2-in. grout thickness, a concrete compressive strength of 4 ksi for
the pier, and ASTM A36 steel for the base plate. Determine the minimum, pier size for this
column
4- Design a base plate for an HSS 10’’ x8’’x5/8’’ column with a factored axial compression
load of 400 kips. Assume a 2-in. grout thickness with 𝑓′𝑐 = 4𝑘𝑠𝑖 and a concrete compressive
strength of 𝑓′𝑐 = 3 𝑘𝑠𝑖 for the pier, and ASTM A36 steel for the base plate. Determine the
minimum, pier size for this column