P/N: 4-BI010L

JOULES MILES CO., LTD.


Rev. D

SPECIFICATION APPROVAL SHEET Page 1

Customer : 鋇鎝科技

Descriptions : Rechargeable lithium-ion battery pack

Customer P/N : NX1-1004

Joules Miles P/N : 4-BI010L

Date : 2013/06/05

Customer Approval

JOULES MILES
P/N: 4-BI010L
JOULES MILES CO., LTD.
Rev. D

SPECIFICATION APPROVAL SHEET Page 2

Amendment Record
Revision Date Description Prepared by Approved by

A 2013/01/04 New issued. Ivan Lang


Modified the Customer P/N(model name)
B 2013/03/20 Emily Lang
and delete the MOSFET(PM2017).
Modified the Battery Pack Parts List Label
C 2013/05/15 Emily Lang
Information.
Modified the Model name and Label
D 2013/06/05 Emily Lang
Information.
P/N: 4-BI010L
JOULES MILES CO., LTD.
Rev. D

SPECIFICATION APPROVAL SHEET Page 3

1. Scope
This product specification shall be applied to rechargeable lithium-ion battery pack.
2. Descriptions and Model Number
(1) Descriptions Rechargeable Lithium-ion battery pack
(2) Battery Cell Configuration 1S2P
(3) Model Number NX1-1004
3. Composition
Lithium-ion battery and Protection circuit module (PCM) and case
4. Product Specification :

Cell model Li-ion, UF484462S, 1530mAh, Sanyo


Battery pack capacity 3060mAh
Battery pack Nominal Voltage 3.7V
End voltage 2.75V
Optimum charge current(at 25℃) ≦1.53A
Max charge voltage 4.2±0.03V
Max discharge current(at 25℃) ≦1.7A
Internal Resistance ≦160mΩ
Charging method CC/CV (Constant current/ voltage)
Charge:0~40℃
Operation temperature
Discharge:-20~60℃
-20~50℃(Less then 1 month)
Storage Temperature -20~40℃(Less then 3 month)
-20~20℃(Less then 1 year)
Weight <75g
Battery pack to be ROHS compatible
Battery pack shall be shipped in a 30~50% charged state.
P/N: 4-BI010L
JOULES MILES CO., LTD.
Rev. D

SPECIFICATION APPROVAL SHEET Page 4

5. Battery pack protection function


*Over charge and over discharge detection voltage per cell.
5.1
Battery pack overcharge detection voltage 4.275±0.025 V
Battery pack overcharge release voltage 4.175±0.025 V
Battery pack overcharge delay time 0.96~1.4 sec
5.2
Battery pack overdischarge detection voltage 2.300±0.050 V
Battery pack overdischarge release voltage 2.400±0.050 V
Battery pack overdischarge delay time 144±29 msec
5.3
Battery pack overcurrent detection current (Vcell=3.7V) 2.13~3.42 A
Battery pack overcurrent release Reset by load release
Battery pack overcurrent delay time 7.2~11 msec
5.4
PCM current consumption 0.7~8.0 μA
5.5
Short circuit detection delay time 150~540 μsec
P/N: 4-BI010L
JOULES MILES CO., LTD.
Rev. D

SPECIFICATION APPROVAL SHEET Page 5

6. Battery Pack Parts List

No 品名 數量 Unit MAKER 備註

1 SANYO Li-ION UF484462 1530mAh 2 PCS SANYO ~

板號:JM-1SP117PP V1.00
保護 IC:S8261AANMD
2 MOS:AO8814 1 PCS 飛天 ~
NTC:10KΩ±1%
ID:24KΩ

3 PPTC, SVS-170NL 1 PCS BOURNS ~

CASE 黑色塑膠殼 材質:PC +ABS (LG 5008)


4 1 PCS 亦誼 ~
ET-5000A (BT-2A)大電專用

5 絕緣 YT130, 0.05*13*30mm (33M) 1 PCS ~ ~

6 3M-6408 0.13*8*40mm 雙背膠 (50M) 1 PCS ~ ~

7 絕緣膠帶, TESA4972, 0.05*40*60mm (100M) 1 PCS ~ ~

8 絕緣 CR4305 2*8*17mm 單背膠 (1M) 1 PCS ~ ~

9 鎳片, 0.127*5*7.5mm 2 PCS ~ ~

10 鎳片, 0.127*3*10mm 1 PCS ~ ~

11 鎳片, 0.127*3*89mm 1 PCS ~ ~

12 絕緣膠帶, NOMEX, 0.13*8*42mm 單背膠 (50M) 1 PCS ~ ~

13 絕緣膠帶, TESA4972, 0.05*8*60mm (100M) 1 PCS ~ ~

14 絕緣膠帶, PET, 0.5*5*6.5mm 2 PCS ~ ~

15 絕緣膠帶, NOMEX, 0.13*8*40mm 單背膠 (50M) 1 PCS ~ ~

16 PET 充型 0.2*42*60mm 單背膠 2 PCS ~ ~


P/N: 4-BI010L
JOULES MILES CO., LTD.
Rev. D

SPECIFICATION APPROVAL SHEET Page 6

17 鎳片, 0.127*7*20mm 1 PCS ~ ~

18 標籤 鋇鎝 BT-2A 包貼 (110.5*63.5mm)反銀龍 50# 1 PCS ~ ~

標籤 BT-2A (大電)=ET-5000 0.086*31.7*41.2mm


19 1 PCS ~ ~
材質:白龍上霧模 * Model no:NX1-1004*

紙箱 (卡其色)
(長)390* (寬)350* (高)116cm
20 0.007 PCS ~ ~
5 層/AB 愣
外觀標示:0.55 裁積

21 井格 (裁格)11+ (寬)85* (長)382mm / 3 層 / A 楞 0.04 PCS ~ ~

22 井格 (裁格)6+ (寬)86* (長)337mm / 3 層 / A 愣 0.074 PCS ~ ~

23 塑膠包裝袋 T0.045mm*W5.5cm*L9.5cm 1 PCS ~ ~


P/N: 4-BI010L
JOULES MILES CO., LTD.
Rev. D

SPECIFICATION APPROVAL SHEET Page 7

7. Terminal Definitions
7.1 Descriptions
Pack﹢(P﹢) : Charge + / Discharge +
Pack﹣(P﹣) : Charge - / Discharge -
TH : Thermistor(10KΩ±1%)
ID : Resistor (24KΩ±1%)
7.2 Diagrams
P/N: 4-BI010L
JOULES MILES CO., LTD.
Rev. D

SPECIFICATION APPROVAL SHEET Page 8

8. Handling Warning
8.1 Do not immerse the battery in water or seawater, and keep the battery in a cool dry
surrounding if it stands by.
8.2 Do not use or leave the battery near a heat source as fire or heater
8.3 When recharging, use the battery charger specifically for that purpose
8.4 Do not reverse the position (+) and negative (-) terminals
8.5 Do not connect the battery to an electrical outlet
8.6 Do not discard the battery in fire or heat it
8.7 Do not short-circuit the battery by directly connecting the positive (+) and negative (-)
terminal with metal objects such as wire.
8.8 Do not transport or store the battery together with metal objects such as necklaces,
hairpins etc.
8.9 Do not strike or throw the battery
8.10 Do not directly solder the battery and pierce the battery with a nail or other sharp object
8.11 If the battery is stored over 3 monthes, it should be checked again about the remaining
capacity and charge the battery.
8.12 We suggest that the voltage of battery should not be lower than 3V when working and
storing, or it may cause unrecoverable decay in its capacity.
P/N: 4-BI010L
JOULES MILES CO., LTD.
Rev. D

SPECIFICATION APPROVAL SHEET Page 9

Content
1. Cell Specification P.10 ~ P.26

2. PCM Specification P.27 ~ P.34

3. Protection IC Specification P.35 ~ P.68

4. MOSFET Specification P.69 ~ P.73

5. Dimension P.74 ~ P.75

6. Label P.76 ~ P.77


P/N: 4-BI010L
JOULES MILES CO., LTD.
Rev. D

SPECIFICATION APPROVAL SHEET Page 10

1. Cell Specification
Contents

Page
1. Publication Record 1

2. Safety Instructions 2-5

3. Extent of the Application 6

4. Battery Classification and Type 6

5. Nominal Specifications 6

6. Electrical Characteristics 7-8

7. Design and Dimensions 8

8. Appearance 8

9. Shipping Charge 8

10. Precautions on Designing of Barcode Scanner, 9-10


the Charger and the Battery Pack

11. Storing Conditions 11

12. Handing Precautions for Lithium Ion Cells 11

13. Warranty Exemptions 12

14. Other Remarks 12

15. Standard Charging Method 12

16. Battery Warranty Period 13

17. Battery Safety Requirements 13

18. Precautions for Prismatic Cells 13


Title Specifications of Lithium Ion battery (Prismatic Type) page 2/13

2. Safety Instructions

Prohibited Actions

The cell contains flammable objects such as organic solvents. If the battery is
mishandled, it may cause fire, smoke or an explosion and the battery’s functionality will
be seriously damaged. Please read and check the following prohibited actions. Also,
please equip a protection in the application so the application troubles don’t affect the
battery. Additionally, SANYO highly recommends embedding these instructions into the
owner’s manual.

! Danger

 Immersion
"Do not immerse the battery with liquid such as water, sea water or soda."
If the protection circuit in the battery is broken with liquid, the battery cannot be
protected and may on fire, smoke, explode, or cause heat generation. by unexpected
electrical load.
 High Temperature
"Do not use or place the battery near fire, a heater or a high temperatures (more than
80℃)."
The battery’s polyolefin separator may get damaged from the heat and could cause an
internal short circuit. This may cause the battery to catch on fire, smoke, explode, or
cause heat generation.
 Charger and Charge Condition
"Do not use unauthorized chargers."
If the battery is charged under unacceptable conditions (For example: usage in restricted
temperature ranges, over voltage, or over current with unauthorized chargers) the
battery may catch on fire, smoke, explode, or cause heat generation.
 Reverse Polarity
"Do not force a reverse-charge or a reverse-connection."
The battery has correct polarity. If the battery doesn’t fit, please check the battery’s
orientation and do not force into the battery mount. If the battery is forced to set with a
different polarity, the battery may catch on fire, smoke, explode, or cause heat
generation.
 Direct Connection
"Do not connect the battery with AC plug (outlet) or car plugs."
The battery requires a specific charger. If the battery connects with the outlet directly,
the battery may catch on fire, smoke, explode, or cause heat generation.

Energy Company, SANYO Electric Co., Ltd.


File No UF484462-027 Portable Rechargeable Battery Business Group
Lithium-Ion Battery Business Unit
Title Specifications of Lithium Ion battery (Prismatic Type) page 3/13

 Inappropriate Use with Other Equipment


"Do not adapt the battery to unspecified applications. "
If the battery is used for unspecified applications or systems, the battery may get
damaged or catch on fire, smoke, explode, or cause heat generation.
 Incineration and Heat
"Please keep the battery away from heat and fire"
The battery materials will get damaged and may catch on fire, smoke, explode, or cause
heat generation.
 Short-Circuit
"Do not make a short-circuit. "
Do not connect the + and - terminals with conductive material. Do not carry or store the
battery with metal objects (such as wire, necklace or hairpins). If the battery is in a
short-circuit, excessive large current will flow and may catch on fire, smoke, explode, or
cause heat generation.
 Impact
" Avoid unnecessary impact to the battery"
Unnecessary impact may cause the battery to leak, heat generation, smoke, fire or
explode. Also, the protection circuit may break and that will lose the function of the
battery’s protection system.
 Penetration
" Do not penetrate with a nail or strike with a hammer"
The battery cell may get destroyed or damaged. And the battery’s protection circuit may
get damaged and case an internal short-circuit. Additionally, the battery may catch on
fire, smoke, explode, or cause heat generation.
 Soldering
"Do not directly solder the battery"
The insulator could melt or the gas release vent might get damaged from the heat.
Additionally, the battery may catch on fire, smoke, explode, or cause heat generation.
 Disassemble and Reconstruction
"Do not disassemble the battery"
If the protection circuit gets damaged, the battery will not be protected. Then, the battery
may catch on fire, smoke, explode, or cause heat generation.
 Charge near High Temperatures
"Do not charge the battery near high temperatures"
If the battery is charged near high temperatures, the battery may not be able to charge
due to the activation of the protection circuit. In these conditions, the protection circuit
may break and the battery may catch on fire, smoke, explode, or cause heat
generation.

Energy Company, SANYO Electric Co., Ltd.


File No UF484462-027 Portable Rechargeable Battery Business Group
Lithium-Ion Battery Business Unit
Title Specifications of Lithium Ion battery (Prismatic Type) page 4/13

! Warning

 Ingestion
"Keep away from infants"
The battery should be kept away from infants. In case of swallowing the battery, see a
doctor immediately.
 Storing
"Do not put the battery in the microwave or other cooking appliances"
The battery may on fire, smoke, explode, or cause heat generation due to heat or the
electrical impact from the microwave.
 Mixed Use
"Do not mix the battery with other batteries."
The battery should not be used with other batteries with different capacity, chemistry or
manufacturer. Do not connect with other batteries or mix with other batteries. The battery
may catch on fire, smoke, explode, or cause heat generation.
 Rust, Changing Color and Deformities
"Do not use abnormal batteries."
Please stop using the battery if there are noticeable abnormalities such as abnormal
smell, heat, deformities, or discoloration. The battery may have a defect and may catch
fire, smoke, heat generation or explode if used continuously.
 Charging Time
" Stop charging if the charging process cannot be finished."
If the battery can not finish the charging process within the specified time, please stop
the charging process. The battery may catch on fire, smoke, explode, or cause heat
generation.
 Leakage①
"Do not use a leaking battery near flames"
If the battery or liquid leaking from the battery has a pungent odor, the battery should keep
away from flames. The battery may ignite and explode.
 Leakage②
"Do not touch a leaking battery"
If the liquid leaking from the battery gets into eyes, it will cause significant damage. If the
leaking liquid gets into your eyes, please flush eyes immediately with pure water. Please
consult a physician immediately. If the liquid remains in the eyes it will cause significant
damage.
 Transport
" Pack the battery tightly during transport"
To prevent short-circuit or damages, please tightly pack the battery into a case or a
carton box.

Energy Company, SANYO Electric Co., Ltd.


File No UF484462-027 Portable Rechargeable Battery Business Group
Lithium-Ion Battery Business Unit
Title Specifications of Lithium Ion battery (Prismatic Type) page 5/13

! Caution

 Use under Direct Sunlight


Do not use or leave the battery in excessive heat such as in a car in direct sunlight.
The battery may catch on fire, smoke, explode, or cause heat generation. Also, it might
cause a deterioration of battery's characteristics and battery life.
 Static Electricity
The battery pack has a protection circuit. Do not use the battery where it generates static
electricity (more than 100V) that might damage the protection circuit. If the protection
circuit is broken, the battery may catch on fire, smoke, explode, or cause heat
generation.
 Charging Temperature Range
Charging temperature range is regulated between 0℃ and 40℃. Do not charge the
battery out of the specified temperature range. Otherwise, it may cause heat generation,
leakage or a serious damage. Also, it might cause deterioration of the battery's
characteristics and battery life.
 Manual
Please read the manual before usage. Please save the manual for future reference.
 Charging Method
Please read the charger’s manual for the charging method.
 First Time Use
Please contact the supplier If the battery has unusual odor, heat generation or rusts
during the first usage.
 Use by Children
Parents must explain how to use the system and the battery. Please check back
periodically to ensure children are using the system and the battery correctly.
 Inflammable Materials
Please keep away from flammable materials during the charge and the discharge. It may
catch on fire, smoke, explode, or cause heat generation.
 Leakage
If electrolyte leak from the battery and adhere to the skin or clothes, immediately flush it
with water. Otherwise, it may cause skin irritation.
 Insulation
If lead wires or metal objects come out from the battery, please seal and insulate them
completely. Otherwise, the battery may cause a short circuit and catch on fire, smoke,
explode, or cause heat generation.
 Recycle
Please recycle the battery according to local rules or regulations after use.

Energy Company, SANYO Electric Co., Ltd.


File No UF484462-027 Portable Rechargeable Battery Business Group
Lithium-Ion Battery Business Unit
Title Specifications of Lithium Ion battery (Prismatic Type) page 6/13

3. Extent of the Application


This specification is applied to SANYO Lithium Ion Battery of
UF484462S-H00AA for Barcode Scanner with Skypower Enterprise Co., Ltd..

For special applications in which quality and reliability are required, or if the failure or malfunction
of the products may directly jeopardize life or cause threat of personal injury such as for weapon,
aircraft and aerospace equipment, aircraft electronics equipment, medical equipment (a part of
class 2 equipment, class 3 or more equipment), or cause large-scale system troubles,
explosion-proof equipment, electric vehicle, hybrid electric vehicle, and electric motor cycle (except
electric power-assisted bicycle), this specification shall not be applied.

4. Battery Classification and Type


4.1 Battery Classification SANYO Lithium Ion Battery
4.2 SANYO Model No. UF484462S-H00AA
4.3 Cell Type UF484462S

5. Nominal Specifications
Items Specifications Notes
5.1 Rated Capacity (Minimum) 1530mAh 0.30A discharge at 20℃
5.2 Nominal Capacity (Minimum) 1530mAh 0.30A discharge at 25℃
5.3 Nominal Capacity (Typical) 1590mAh Reference only
5.4 Nominal Voltage 3.7V 0.30A discharge at 25℃
5.5 Discharging End Voltage 2.75V
5.6 Charging Current (Std.) 1.53A
5.7 Charging Voltage 4.20 ± 0.03V
5.8 Charging Time (Std.) 3.0 hours
※1
5.9 Continuous Discharging Current (Max.) 3.06A 0 ~ +40℃
5.10 Internal Resistance less than 100mΩ AC Impedance 1 kHz
5.11 Weight less than 30.6g
Charge 0 ~ +40℃
5.12 Operating Temperature
Discharge -20 ~ +60℃
5.13 less than 1 month -20 ~ +50℃ Percentage of
Storing Conditions less than 3 months -20 ~ + 40℃ recoverable capacity
less than 1 year -20 ~ + 20℃ 80%※2
※1 The maximum discharge current for a single cell use. However after the battery pack assembly ,
there will be a limitation of maximum discharge current due to a protection circuit or a protection
device.
※2 Percentage of recoverable capacity
= (Discharging time after storage / Initial discharging time) ×100
The discharging time is measured by the discharge current of 0.30A until 2.75V of end voltage
after the battery is fully charged at 25℃.

Energy Company, SANYO Electric Co., Ltd.


File No UF484462-027 Portable Rechargeable Battery Business Group
Lithium-Ion Battery Business Unit
Title Specifications of Lithium Ion battery (Prismatic Type) page 7/13

6. Electrical Characteristics
Items Conditions Criteria
6.1 Full Charge The battery is charged with 1.53A constant current
until the voltage reaches 4.20V. Then, the current is
reduced in order to keep the constant voltage of
4.20V. The total charging time is 3.0 hours at 25 ℃.

6.2 Capacity ①Within 1 hour, after fully charged at 25℃, the More than 300min.
battery is discharged with 0.30A continuously until
2.75V of end voltage at 25℃.

②Within 1 hour, after fully charged at 25℃, the More than 54min.
battery is discharged with 1.53A continuously until
2.75V of end voltage at 25℃.

6.3 Cycle Life The battery is repeated 500 times of Charge and More than 32min.
Discharge cycles, (Charged by CC-CV of
1.53A-4.20V for 3.0 hours, Discharged by CC of
1.53A to 2.75V (E.V.)) at 25℃. After the 500
cycles, the discharge time is measured by the Item
6.2.②.

6.4 Temperature ①Within 1 hour, after fully charged at 25℃, the More than 30min.
Characteristics battery is stored at 0 ℃ for 3 hours. After that, the
discharge time is measured Item 6.2.② at 0 ℃.

②Within 1 hour, after fully charged at 25℃, the More than 50min.
battery is stored at 60 ℃ for 3 hours. After that,
the discharge time is measured Item 6.2.② at
60 ℃.

6.5 Storage at Fully After fully charged at 25℃, the battery is stored for More than 30min.
Charged State 20 days at 60 ℃. After the storage, the battery is
set in 25℃ for 3 hours. Then, the discharge time is
measured Item 6.2.②.

Then, the same battery is fully charged again and More than 40min.
checked the second discharge time by the Item 6.2
② at 25 ℃.

Energy Company, SANYO Electric Co., Ltd.


File No UF484462-027 Portable Rechargeable Battery Business Group
Lithium-Ion Battery Business Unit
Title Specifications of Lithium Ion battery (Prismatic Type) page 8/13

6.6 Storage at Full After fully charged at 25℃, the battery is More than 50min.
Discharged State discharged by the Item 6.2.②. Then, the battery is
stored for 20 days at 60 ℃. After the storage, the
battery is set in 25℃ for 3 hours. Then, the
discharge time is measured by Item 6.2.② at 25℃.

6.7 Drop After fully charged at 25℃, the cell is dropped 3 No rupture, no fire
times in random direction from a height of 1 m onto
a flat surface of concrete.

STANDARD TEST CONDITIONS:


The testes shall be implemented with new batteries that were delivered within the last 7 days.
The tests shall be performed at 25±2 ℃ (The standard temperature of second grade is specified
by JIS Z 8703 (Standard Test Conditions)), 65±20 % (The standard humidity of twentieth grade is
specified by JIS Z 8703 (Standard Test Conditions)). The grade of voltmeter and ammeter in the
tests shall be higher than Class 0.5 which is specified by JIS C 1102 (Electric Indicator).

7. Design and Dimensions


The battery design is shown in the following documents or drawings.
(Drawing No.UF484462S-H00AA01)

8. Appearance
The battery should not have the following appearance issues at delivery:
・Scratch
・Rust
・Discoloration
・Dirt
・Deformation
・Leakage
The battery should be in good condition.

9. Shipping Charge
The battery is shipped out with the approximately 30%* charged state.
*The 30% capacity is the condition in which SANYO ships the battery but it’s not the
condition when Skypower Enterprise Co., Ltd. receives the battery.

Energy Company, SANYO Electric Co., Ltd.


File No UF484462-027 Portable Rechargeable Battery Business Group
Lithium-Ion Battery Business Unit
Title Specifications of Lithium Ion battery (Prismatic Type) page 9/13

10. Precautions for Designing of Barcode Scanners, the Chargers and the
Battery Packs
10-1. Precautions for Designing of Barcode Scanner and the Charger.
(1) Charge
・ The battery is charged by a method of constant current-constant voltage.
・ Regarding UF484462S-H00AA, the charging current should not exceed 1.53A /cell.
・ The charging voltage should not exceed 4.20V /cell.
The charging voltage is required to be set to less than 4.23V/cell with considering the
accuracy of charger. Even if the charger is failed, the total safety shall be secured.
・ The charger shall be equipped with a pre-charge system.
If battery voltage goes down to less than 3.0V/cell, the battery should be charged by
pre-charge current of maximum 0.10A. Once, the battery reached more than 3.0V/cell by
the pre-charging, the charger can resume the standard charging method. However, if the
battery voltage never recovers more than 3.0V/cell, the charger must be stopped and
turned off.
・ The charger shall be equipped a full charge detection.
The charger shall detect the full-charged state by a timer, current detection or open
circuit voltage detection. When the charger detects the full-charge, the charger shall stop
charging. Do not apply the continuous charging (trickle charging) method.
・ The charging temperature range should be set between 0 ℃ to +40 ℃.
(2) Discharge
・ The discharge current should not exceed 3.06A/cell.
・ The discharge temperature should be between -20℃ to +60 ℃.
・ The discharge end voltage should be more than 2.75V/cell.
(3) Over discharge
・ Do not discharge the battery less than 2.0V/cell.
(4) Design of Barcode Scanners and chargers.
・ The cells should be kept away from heat generating electronic parts in order to avoid
deterioration of battery performance.
10-2. Precautions for Battery Pack Design.
(1) Shape, mechanism and material of battery packs
・ The battery pack should be designed so it does not connect with to unauthorized
chargers.
・ The battery pack should be designed so it cannot connect with unauthorized equipment
and/or devices.
・ The terminal shape should be designed to avoid short circuit issues. In addition, the
battery pack should be equipped with an over current protection function in order to
prevent from external short circuit issues.
・ The terminal shape and structure should be designed so it does not connect in
backwards.
・ The battery pack should be designed to prevent static electricity, electrolyte or water
ingress issues.

Energy Company, SANYO Electric Co., Ltd.


File No UF484462-027 Portable Rechargeable Battery Business Group
Lithium-Ion Battery Business Unit
Title Specifications of Lithium Ion battery (Prismatic Type) page 10/13

・ The battery pack should be designed so the protection circuit functions can be inspected
during the assembly process.
・ The battery pack should be designed so electrolyte cannot reach to the protection circuit
board even if electrolyte leak out of the cells.
・ The cells should be fixed by a tape or a glue in the case. If the battery pack is dropped,
the cells should be protected against dents, deformations and other mechanical
stresses.
・ Do not apply heat, pressure, shock or any other damaging elements to the gas release
vent area. SANYO will not take any responsibilities for defects of cell performance or
troubles caused by them.
・ Plastic cases should be closed with glue. If an ultra sonic welding method is applied to
the case sealing, SANYO will not take any responsibilities for any defects.
・ The pack shall be designed so end users cannot remove or disassemble the cells.
・ Protection devices (For example: PTC or a thermal fuse) shall be equipped on every cell
in the appropriate area of the cell where temperature can be detected accurately. A
wrong setting will result in defects and issues.
(2) Protection circuit
The following protection circuit should be equipped in the battery pack:
・ Overcharge protection
We recommend the overcharge protection works when cell voltage reaches more than
4.25V/cell Then, the current shall be shut down.
・ Over discharge protection
If cell voltage reaches approximately 2.2V/cell, we recommend the over discharge
protection will shut down the discharge current and the circuit consumption current will
be set to less than 1µA.
・ Over current protection
If discharge current exceeds approximately 3.06A/cell, the over current protection will
shut down the current.
(3) Electric circuit
・ To avoid over discharge mode during long storage times, the consumption current of the
battery pack’s protection circuit should be set as low as possible.
(4) Cell connection
・ The cells should not be connected using a soldering process. In order to avoid any
damages, cells should be connected to lead plates by a spot welding method.
(5) Precautions on label
・ The rating label should indicate required information and precautions.
The precautions should be based on the information in section 2.

Energy Company, SANYO Electric Co., Ltd.


File No UF484462-027 Portable Rechargeable Battery Business Group
Lithium-Ion Battery Business Unit
Title Specifications of Lithium Ion battery (Prismatic Type) page 11/13

11. Storing Condition


11-1 Storage Temperature and Humidity (Within 3 months)
・ Cells should be stored between -20℃ to +40℃ in a low humidity condition (less than
70 %RH) without any corrosive gases.
・ No condensation on the cell
11-2 Long Duration Storage
・ Cells should be stored between -20℃ to +20℃ in a low humidity condition (less than
70%RH) without any corrosive gases. We recommend the discharged state or partially
charged state SANYO shipped out for the long duration storage.
・ No condensation on cells.

12. Handling Precautions for Lithium Ion Cells


・This section describes handling precautions for SANYO lithium ion cells which will be
assembled as Barcode Scanner’s battery packs with Skypower Enterprise Co., Ltd..
This battery pack consists of UF484462S.
12-1 Series Connections Precautions
・ When cells are connected in series, make sure the lot number, the shipping charge
date, and capacity rank match. Please do not mix cells with different lot numbers,
shipping charge date, and capacity rank. Also, the voltage variability should be within
20mV.
・ The lot number, the shipping charge date and the capacity rank are indicated on the
shipping carton label.
・ If cells are connected in series, the discharge end voltage should be set more than
3.0V/cell.
12-2 Cell Terminal Precautions
・ Do not apply excessive stress to the cell terminals. It may cause a leakage or
short-circuit.
12-3 Inspection of the Battery Pack before Shipping
All battery packs shall be inspected for:
・Voltage
・Internal impedance
・Function of protection circuit
・Thermistor resistance
・Thermal fuse
12-4 Abnormal Cells
・ Do not use damaged cells by dropping, and/or short circuit and cells with electrolyte
smell and any other damaged cells.

Energy Company, SANYO Electric Co., Ltd.


File No UF484462-027 Portable Rechargeable Battery Business Group
Lithium-Ion Battery Business Unit
Title Specifications of Lithium Ion battery (Prismatic Type) page 12/13

13. Warranty Exemptions


・ SANYO will not be liable for any damages that are caused by violations of the
precautions in this specification.
・ SANYO will not be liable for any problems caused by design defects of the battery packs,
Barcode Scanners and/or chargers.
・ SANYO will not accept any abnormal cells that were caused due to any incorrect
assembly process.

14. Other Remarks


・ If there are problems in this specification, SANYO will take them into consideration.
・ SANYO can discuss specs or precautions that are not described in this specification.
・ Do not use the provided cells for other applications.

15. Standard Charging Method


(1) The standard charge condition is 1.53A/cell - 4.20V/cell (Constant current-constant
voltage). The charging process should be discontinued when either time, the, OCV or
current, reach certain values.

(2) In case of the over discharge state (For example: Battery voltage is less than
2.0V/cell), the battery should be charged by a pre-charge system in order to prevent
FET’s heat generation in a circuit.

(3) The pre-charging current should be approximately 0.10A. Once, the battery voltage
reaches more than 3.0V/cell, the charger can resume the standard charging method.
The pre-charging should have a cut-off timer and if the voltage doesn’t recover over
3.0V/cell in the set time, the charging should be stopped.

(4) The cell may be swelled during usage, continuous charging, and especially under the
high temperature.
Please consult SANYO for the charging method instructions.

Energy Company, SANYO Electric Co., Ltd.


File No UF484462-027 Portable Rechargeable Battery Business Group
Lithium-Ion Battery Business Unit
Title Specifications of Lithium Ion battery (Prismatic Type) page 13/13

16. Battery Warranty Period


The warranty period is limited to one year from date of shipment. SANYO will replace
batteries if it is clear that there was a defect in SANYO’s manufacturing process and that
the battery was not misused.

17. Battery Safety Requirements


In order to ensure the safety of the battery, please contact SANYO to discuss the
application design from a mechanical or a electrical viewpoint. Also, if there are special
conditions (For example: lager current load, a quick charge method or an unique usage
pattern), please contact SANYO to check the conditions before the product specification is
fixed.

18. Precautions for Prismatic Cells


Prismatic type cells may swell during usage. The value described in the drawing is the
thickness after 500 cycles (Please refer to section 6.3). Cell thickness may swell
unexpectedly in the below scenarios:
・The charging voltage exceed 4.20V.
・The ambient temperate of usage is not 25±2 ℃.
・The battery is charged and discharged more than 500 cycles.
・The battery is stored for a long time.

Energy Company, SANYO Electric Co., Ltd.


File No UF484462-027 Portable Rechargeable Battery Business Group
Lithium-Ion Battery Business Unit
P/N: 4-BI010L
JOULES MILES CO., LTD.
Rev. D

SPECIFICATION APPROVAL SHEET Page 27

2. PCM Specification
Number:JM-1SP117PP
V1.00
POWERPCM Material or Specification Reversion : A
Date : 2012/09/18
Technology Page : 1/7

Title : Protection Circuit Module forJM-1SP117PP V1.00

變更履歷

History of revision

變更年月日 變更事項

Date Description
1. 2012/09/18 “Version A” ( the first issue)

Powerpcm Confidential Proprietary


Number:JM-1SP117PP
V1.00
POWERPCM Material or Specification Reversion : A
Date : 2012/09/18
Technology Page : 2/7

Title : Protection Circuit Module forJM-1SP117PP V1.00

1 PURPOSE AND SCOPE


This document contains specific electrical, environmental, circuit
diagram, PCB layout for the protection circuit module of Li-ion cells.

2 DESCRIPTION AND APPLICATION


2.1 DESCRIPTION
The JM-1SP117PP V1.00 PCM provides protection functions for a
single-cell Li-ion battery.
2.2 APPLICATION
The PCM is designed for use in lithium battery
3 COMPONENT REQUIREMENTS
3.1 ABSOLUTE MAXIMUM RATING
Item Ratings Unit
Operating temperature -20 ~ +70 ℃
Operating humidity less then 85%RH (without dew) %RH
Storage temperature range -25 ~ +85 ℃
Storage humidity range less then 85%RH (without dew) %RH
Voltage between terminals of P+ and P- +12 V
Power dissipation 96 uW

Remarks:
The negative voltage is not allowed to be applied between the P+ and P-
terminals or between the B+ and B- connection terminals.

3.2 SPECIFICATION OF PCB

Material FR4 PCB


UL 94V-0
Dimension 38.1 (+/-0.1) x7.6 (+/-0.1) x 0.6 (±0.1)mm
Structure 2 layers with through hole
Silk Printed

Powerpcm Confidential Proprietary


Number:JM-1SP117PP
V1.00
POWERPCM Material or Specification Reversion : A
Date : 2012/09/18
Technology Page : 3/7

Title : Protection Circuit Module forJM-1SP117PP V1.00

4 PIN ASSIGNMENT AND DESCRIPTION


Component side :

Solder side :

Pin Description
B+ Connect to + terminal of cell
B- Connect to – terminal of cell
P+/+ Output+ / Charger +
P-/- Output - / Charger -
TH Temperature detect NTC10KΩ±1%
ID Identification (Resistor 24KΩ±1%)

5 BASIC FUNCTION
5.1 Over Charge Protection
If the voltage threshold of 4.275 ± 0.025V is exceeded , the over voltage
protection circuit will stop the charge pathway, preventing the battery from
accepting charge current.
5.2 Over Discharge Protection
If the battery voltage reaches a minimum under voltage threshold of 2.300 ±
0.050V the JM-1SP117PP V1.00 PCM protection circuit shall stop the discharge
path and put the battery in power down mode. The JM-1SP117PP V1.00 PCM
shall be recoverable from power down mode when placed in any approved
charger.

Powerpcm Confidential Proprietary


Number:JM-1SP117PP
V1.00
POWERPCM Material or Specification Reversion : A
Date : 2012/09/18
Technology Page : 4/7

Title : Protection Circuit Module forJM-1SP117PP V1.00

5.3 Over current Protection


It shall stop discharging for an excessive discharge current at
2.13A~3.42A within 11 milliseconds. When a load is placed across the
terminals of the PCM to trip the overload current protection and then the
load is removed from the P+ and P- terminals, all protection functionality
shall return to the PCM without having to place it into a charger.

5.4 Short Circuit Protection


It shall stop discharging for an short circuit condition occurs when the
terminals between P+ and P- is shorted within 540 microseconds. When a
short circuit is placed across the terminals of the PCM to trip the short
circuit protection and then the short circuit is removed from the battery
terminals, all protection functionality shall return to the PCM without
having to place it into a charger.
6 CIRCUIT DIAGRAM

B+ P+
B+ 1 1

P+
R1
470
小電流, 極短距離

U1
1A電流, 盡量直線設計
S-8261AANMD
5

C2
0.1uF
3A電流, 盡量直線設計
VDD

C1 4
0.1uF DP 3A電流, 極短距離
2
VM

6
VSS
DO

CO

C3
0.1uF
1

R2 R3
2K 24K±1%
ID
1 ID
RT1
10K(NTC)±1%
TH
4

1 TH
2 7
3 1 8 6
B- P-
B- 1 Q1A
PM2017
Q2B
PM2017
1 P-

C4 C5
0.1uF 0.1uF

Powerpcm Confidential Proprietary


Number:JM-1SP117PP
V1.00
POWERPCM Material or Specification Reversion : A
Date : 2012/09/18
Technology Page : 5/7

Title : Protection Circuit Module forJM-1SP117PP V1.00

7 PCB LAYOUT
TOP-SILK

BOT-SILK

TOP-SIDE

BOT-SIDE

TOP-MASK

BOT-MASK

Powerpcm Confidential Proprietary


Number:JM-1SP117PP
V1.00
POWERPCM Material or Specification Reversion : A
Date : 2012/09/18
Technology Page : 6/7

Title : Protection Circuit Module forJM-1SP117PP V1.00

VIAS

DRILL

8 Bill of Materials
Document : PCM JM-1SP117PP V1.00 Subject: Reversion : A
Model : JM-1SP117PP V1.00 Date: 2012/09/18
Bill of materials forJM-1SP117PP V1.00
No. Q'ty Maker Remark
Ref. Part Name DESCRIPTION Package

1 U1 Protect IC S-8261AANMD SOT23-6 1 Seiko

2 Q1 Mosfet TSSOP8 1 Aos


AO8814
3 C1~C5 Capacitor 0.1uF / 50V / Y5V 0603 5 Yageo / Pdc
4 R1 Resistor 470Ω ± 5 % 0603 1 Yageo / Pdc
5 R2 Resistor 2KΩ ±5 % 0603 1 Yageo / Pdc
6 R3 Resistor 24KΩ ±1 % 0603 1 Yageo / Pdc
TH11-3H103FT
7 RT1 Thermistor 0603 1 Mitsubishi
- 10K NTC ±1%
38.1(+/-0.1)X7.6(+/-0.1)
8 PCB Axial 1 Sj
X0.6(+/-0.1) 2L / 3u”/ BK

Powerpcm Confidential Proprietary


Number:JM-1SP117PP
V1.00
POWERPCM Material or Specification Reversion : A
Date : 2012/09/18
Technology Page : 7/7

Title : Protection Circuit Module forJM-1SP117PP V1.00

9 MAIN SPECIFICATION
( @ 25℃ )
ITEM Specification UNIT
Over-charge detection voltage 4.275±0.025 V
Over-charge release voltage 4.175±0.025 V
Over-discharge detection voltage 2.300±0.050 V
Over-discharge release voltage 2.400±0.050 V
Over-current detection current (Vcell=3.7V) 2.13~3.42 A
Over-charge detection delay time 0.96~1.4 sec
Over-discharge detection delay time 144±29 msec
Over current detection delay time 7.2~11 msec
Short detect delay time 150~540 μsec
Over-current release Reset by load release
Current consumption 0.7~8.0 μA
PCM Internal Resistor Less 60 mΩ

Powerpcm Confidential Proprietary


P/N: 4-BI010L
JOULES MILES CO., LTD.
Rev. D

SPECIFICATION APPROVAL SHEET Page 35

3. Protection IC Specification
Rev.4.6_00

BATTERY PROTECTION IC FOR 1-CELL PACK S-8261 Series

The S-8261 series are lithium-ion / lithium polymer rechargeable


battery protection ICs incorporating high-accuracy voltage
detection circuit and delay circuit.
The S-8261 series are suitable for protection of single-cell lithium
ion/lithium polymer battery packs from overcharge, overdischarge
and overcurrent.

„ Features
(1) Internal high accuracy voltage detection circuit
• Overcharge detection voltage 3.9 V to 4.4 V (applicable in 5 mV step) Accuracy: ±25 mV (+25°C) and
±30 mV (−5°C to +55°C)
• Overcharge hysteresis voltage 0.1 V to 0.4 V*1 Accuracy: ±25 mV
The overcharge hysteresis voltage can be selected from the range 0.1 V to 0.4 V in 50 mV step.
• Overdischarge detection voltage 2.0 V to 3.0 V (applicable in 10 mV step) Accuracy: ±50 mV
• Overdischarge hysteresis voltage 0.0 V to 0.7 V*2 Accuracy: ±50 mV
The overdischarge hysteresis voltage can be selected from the range 0.0 V to 0.7 V in 100 mV step.
• Overcurrent 1 detection voltage 0.05 V to 0.3 V (applicable in 10 mV step) Accuracy: ±15 mV
• Overcurrent 2 detection voltage 0.5 V (fixed) Accuracy: ±100 mV
(2) High voltage device is used for charger connection pins (VM and CO pins: absolute maximum rating = 28 V).
(3) Delay times (overcharge: tCU, overdischarge: tDL, overcurrent 1: tlOV1, overcurrent 2: tlOV2) are generated by an internal
circuit. No external capacitor is necessary. Accuracy: ±20%
(4) Three-step overcurrent detection circuit is included (overcurrent 1, overcurrent 2 and load short-circuiting).
(5) 0 V battery charge function “Available” / “Unavailable” are selectable.
(6) Power-down function “Yes” / “No” are selectable.
(7) Charger detection function and abnormal charge current detection function
• The overdischarge hysteresis is released by detecting negative voltage at the VM pin (−0.7 V typ.) (Charger detection function).
• When the output voltage of the DO pin is high and the voltage at the VM pin is equal to or lower than the charger detection
voltage (−0.7 V typ.), the output voltage of the CO pin goes low (Abnormal charge current detection function).
(8) Low current consumption
• Operation mode 3.5 µA typ., 7.0 µA max.
• Power-down mode 0.1 µA max.
(9) Wide operating temperature range −40°C to +85°C
(10) Small package SOT-23-6
(11) Lead-free product

*1. Overcharge release voltage = Overcharge detection voltage − Overcharge hysteresis voltage (where overcharge
release voltage < 3.8 V is prohibited.)
*2. Overdischarge release voltage = Overdischarge detection voltage + Overdischarge hysteresis voltage (where
overdischarge release voltage > 3.4 V is prohibited.)

„ Applications
• Lithium-ion rechargeable battery packs
• Lithium polymer rechargeable battery packs

„ Package
Package name Drawing code
Package Tape Reel
SOT-23-6 MP006-A MP006-A MP006-A

Seiko Instruments Inc. 1


BATTERY PROTECTION IC FOR 1-CELL PACK
S-8261 Series Rev.4.6_00

„ Block Diagram

DP

Output control circuit

0 V battery charge circuit


or 0 V battery charge Divider control Oscillator control
DO circuit circuit
inhibition circuit
VDD

+
CO Charger detection circuit

+ Overcharge
detection
− comparator
Overcurrent 1
detection comparator
R VMD

VM +

− +
RVMS Overcurrent 2
detection comparator −

+ Overdischarge
detection
− comparator
Load short-circuiting detection
comparator VSS

Remark All the diodes shown in the figure are parasitic diodes.

Figure 1

2 Seiko Instruments Inc.


BATTERY PROTECTION IC FOR 1-CELL PACK
Rev.4.6_00 S-8261 Series

„ Product Name Structure


1. Product Name
S-8261A xx MD - xxx T2 G

IC direction in tape specifications*1


T2: SOT-23-6
Product name (abbreviation)*2

Package name (abbreviation)


MD: SOT-23-6

Serial code
Assigned from AA to ZZ in alphabetical order
*1. Refer to the tape specifications.
*2. Refer to the Product Name List.

Seiko Instruments Inc. 3


BATTERY PROTECTION IC FOR 1-CELL PACK
S-8261 Series Rev.4.6_00

2. Product Name List

Table 1

Overcharge Overcharge Overdischarge Overdischarge Overcurrent 1 Delay


0 V battery
detection hysteresis detection hysteresis detection time Power down
Model No. charge
voltage voltage voltage voltage voltage combi- function
function *1
[VCU] [VHC] [VDL] [VHD] [VIOV1] nation
S-8261AAGMD-G2GT2G 4.280 V 0.20 V 2.30 V 0V 0.16 V Available (1) Yes
S-8261AAHMD-G2HT2G 4.280 V 0.20 V 2.30 V 0V 0.08 V Available (1) Yes
S-8261AAJMD-G2JT2G 4.325 V 0.25 V 2.50 V 0.4 V 0.15 V Unavailable (1) Yes
S-8261AALMD-G2LT2G 4.300 V 0.10 V 2.30 V 0V 0.08 V Unavailable (1) Yes
S-8261AAMMD-G2MT2G 4.300 V 0.10 V 2.30 V 0V 0.20 V Unavailable (1) Yes
S-8261AANMD-G2NT2G 4.275 V 0.10 V 2.30 V 0.1 V 0.10 V Available (1) Yes
S-8261AAOMD-G2OT2G 4.280 V 0.20 V 2.30 V 0V 0.13 V Unavailable (1) Yes
S-8261AAPMD-G2PT2G 4.325 V 0.25 V 2.50 V 0.4 V 0.10 V Unavailable (1) Yes
S-8261AARMD-G2RT2G 4.280 V 0.20 V 2.30 V 0V 0.10 V Available (1) Yes
S-8261AASMD-G2ST2G 4.280 V 0.20 V 2.30 V 0V 0.15 V Unavailable (2) Yes
S-8261AATMD-G2TT2G 4.300 V 0.10 V 2.30 V 0V 0.08 V Available (3) Yes
S-8261AAUMD-G2UT2G 4.275 V 0.10 V 2.30 V 0.1 V 0.10 V Available (4) Yes
S-8261AAXMD-G2XT2G 4.350 V 0.10 V 2.30 V 0.1 V 0.10 V Available (4) Yes
S-8261AAZMD-G2ZT2G 4.280 V 0.25 V 2.50 V 0.4 V 0.10 V Unavailable (1) Yes
S-8261ABAMD-G3AT2G 4.350 V 0.20 V 2.50 V 0V 0.20 V Available (4) Yes
S-8261ABBMD-G3BT2G 4.275 V 0.20 V 2.30 V 0V 0.13 V Available (1) Yes
S-8261ABCMD-G3CT2G 4.300 V 0.20 V 2.30 V 0V 0.13 V Available (1) Yes
S-8261ABIMD-G3IT2G 4.275 V 0.20 V 2.30 V 0V 0.20 V Unavailable (5) Yes
S-8261ABJMD-G3JT2G 4.280 V 0.20 V 3.00 V 0V 0.08 V Available (1) Yes
S-8261ABKMD-G3KT2G 4.100 V 0.25 V 2.50 V 0.4 V 0.15 V Unavailable (1) Yes
S-8261ABLMD-G3LT2G 4.275 V 0.20 V 2.30 V 0V 0.05 V Unavailable (5) Yes
S-8261ABMMD-G3MT2G 4.280 V 0.20 V 2.80 V 0V 0.10 V Available (1) Yes
S-8261ABNMD-G3NT2G 4.300 V 0.20 V 2.30 V 0V 0.06 V Available (1) Yes
S-8261ABPMD-G3PT2G 4.200 V 0.10 V 2.80 V 0.1 V 0.15 V Unavailable (1) Yes
S-8261ABRMD-G3RT2G 4.275 V 0.20 V 2.50 V 0.4 V 0.15 V Unavailable (1) Yes
S-8261ABSMD-G3ST2G 4.280 V 0.10 V 2.50 V 0.5 V 0.18 V Unavailable (1) Yes
S-8261ABTMD-G3TT2G 4.280 V 0.20 V 3.00 V 0.4 V 0.08 V Available (5) Yes
S-8261ABYMD-G3YT2G 4.275 V 0.10 V 2.30 V 0.1 V 0.10 V Available (6) Yes
S-8261ABZMD-G3ZT2G 4.325 V 0.25 V 2.50 V 0.4 V 0.15 V Unavailable (6) Yes
S-8261ACAMD-G4AT2G 4.280 V 0.20 V 2.30 V 0V 0.13 V Unavailable (6) Yes
S-8261ACBMD-G4BT2G 4.250 V 0.20 V 2.60 V 0.3 V 0.12 V Unavailable (1) No
S-8261ACDMD-G4DT2G 4.350 V 0.25 V 2.30 V 0.7 V 0.25 V Available (7) Yes
S-8261ACEMD-G4ET2G 3.900 V 0.10 V 2.00 V 0.3 V 0.10 V Available (1) Yes
S-8261ACFMD-G4FT2G 4.280 V 0.20 V 2.30 V 0V 0.10 V Available (8) Yes
S-8261ACHMD-G4HT2G 4.465 V 0.30 V 2.10 V 0V 0.15 V Available (9) Yes
S-8261ACIMD-G4IT2G 4.250 V 0.20 V 2.40 V 0.5 V 0.10 V Available (1) No
S-8261ACJMD-G4JT2G 4.275 V 0.10 V 2.30 V 0.1 V 0.15 V Available (1) Yes
S-8261ACKMD-G4KT2G 4.280 V 0.20 V 2.80 V 0V 0.13 V Available (1) Yes
S-8261ACMMD-G4MT2G 4.325 V 0.20 V 3.00 V 0.4 V 0.06 V Unavailable (1) Yes
S-8261ACNMD-G4NT2G 4.215 V 0.10 V 2.30 V 0.1 V 0.13 V Unavailable (1) Yes
*1. Refer to the Table 2 about the details of the delay time combinations (1) to (9).
Remark Please contact our sales office for the products with detection voltage value other than those specified above.

4 Seiko Instruments Inc.


BATTERY PROTECTION IC FOR 1-CELL PACK
Rev.4.6_00 S-8261 Series

Table 2

Overcharge Overdischarge Overcurrent 1 Overcurrent 2 Load short-circuiting


Delay time detection detection detection detection detection
combination delay time delay time delay time delay time delay time
[tCU] [tDL] [tlOV1] [tlOV2] [tSHORT]
(1) 1.2 s 144 ms 9 ms 2.24 ms 320 µs
(2) 1.2 s 144 ms 4.5 ms 2.24 ms 320 µs
(3) 4.6 s 36 ms 18 ms 9 ms 320 µs
(4) 4.6 s 144 ms 9 ms 2.24 ms 320 µs
(5) 1.2 s 36 ms 9 ms 2.24 ms 320 µs
(6) 1.2 s 144 ms 9 ms 1.12 ms 320 µs
(7) 1.2 s 290 ms 18 ms 2.24 ms 320 µs
(8) 1.2 s 144 ms 18 ms 2.24 ms 320 µs
(9) 0.3 s 36 ms 9 ms 1.12 ms 320 µs
Remark The delay times can be changed within the range listed Table 3. For details, please contact our sales office.

Table 3

Delay time Symbol Selection range Remarks


Overcharge detection delay time tCU 0.15 s 1.2 s 4.6 s Choose from the left.
Overdischarge detection delay time tDL 36 ms 144 ms 290 ms Choose from the left.
Overcurrent 1 detection delay time tlOV1 4.5 ms 9 ms 18 ms Choose from the left.
Overcurrent 2 detection delay time tlOV1 1.12 ms 2.24 ms  Choose from the left.
Load short-circuiting detection delay time tSHORT  320 µs 600 µs Choose from the left.
Remark The value surrounded by bold lines is the delay time of the standard products.

Seiko Instruments Inc. 5


BATTERY PROTECTION IC FOR 1-CELL PACK
S-8261 Series Rev.4.6_00

„ Pin Configuration
SOT-23-6 Table 4
Top view Pin No. Symbol Description
6 5 4 FET gate control pin for discharge
1 DO
(CMOS output)
Voltage detection pin between VM and VSS
2 VM
(Overcurrent detection pin)
FET gate control pin for charge
3 CO
(CMOS output)
4 DP Test pin for delay time measurement
1 2 3 5 VDD Positive power input pin
6 VSS Negative power input pin
Figure 2

6 Seiko Instruments Inc.


BATTERY PROTECTION IC FOR 1-CELL PACK
Rev.4.6_00 S-8261 Series

„ Absolute Maximum Ratings


Table 5
(Ta = 25°C unless otherwise specified)
Item Symbol Applied pin Absolute Maximum Ratings Unit
Input voltage between VDD and VSS VDS VDD VSS −0.3 to VSS +12 V
Input pin voltage for VM VVM VM VDD −28 to VDD +0.3 V
Output pin voltage for CO VCO CO VVM −0.3 to VDD+0.3 V
Output pin voltage for DO VDO DO VSS −0.3 to VDD +0.3 V
250 (When not mounted on board) mW
Power dissipation PD  *1
650 mW
Operating ambient temperature Topr  −40 to +85 °C
Storage temperature Tstg  −55 to +125 °C
*1. When mounted on board
[Mounted board]
(1) Board size : 114.3 mm × 76.2 mm × t1.6 mm
(2) Board name : JEDEC STANDARD51-7

Caution The absolute maximum ratings are rated values exceeding which the product could suffer physical
damage. These values must therefore not be exceeded under any conditions.

(1) When mounted on board (2) When not mounted on board


700 600
Power dissipation (PD) [mW]
Power dissipation (PD) [mW]

600 500
500
400
400
300
300
200
200

100 100

0 0
0 50 100 150 0 50 100 150
Ambient temperature (Ta) [°C] Ambient temperature (Ta) [°C]

Figure 3 Power Dissipation of Package

Seiko Instruments Inc. 7


BATTERY PROTECTION IC FOR 1-CELL PACK
S-8261 Series Rev.4.6_00

„ Electrical Characteristics
1. Except Detection Delay Time (25°C)
Table 6
(Ta = 25°C unless otherwise specified)
Test Test
Item Symbol Condition Min. Typ. Max. Unit
Condition Circuit
DETECTION VOLTAGE
VCU VCU
 VCU V 1 1
Overcharge detection voltage −0.025 +0.025
VCU
VCU = 3.9 V to 4.4 V, 5 mV Step VCU VCU
Ta = −5°C to 55°C*1 VCU V 1 1
−0.030 +0.030
Overcharge hysteresis voltage VHC VHC
VHC  VHC V 1 1
VHC = 0.1 V to 0.4 V, 50 mV Step −0.025 +0.025
Overdischarge detection voltage VDL VDL
VDL  VDL V 2 2
VDL = 2.0 V to 3.0 V, 10 mV Step −0.050 +0.050
Overdischarge hysteresis voltage VHD VHD
VHD  VHD V 2 2
VHD = 0.0 V to 0.7 V, 100 mV Step −0.050 +0.050
Overcurrent 1 detection voltage VIOV1 VIOV1
VIOV1  VIOV1 V 3 2
VIOV1 = 0.05 V to 0.3 V, 10 mV Step −0.015 +0.015
Overcurrent 2 detection voltage VIOV2  0.4 0.5
0.6 V 3 2
Load short-circuiting detection voltage VSHORT  0.9 1.2
1.5 V 3 2
Charger detection voltage VCHA  −1.0 −0.7
−0.4 V 4 2
INPUT VOLTAGE, OPERATION VOLTAGE
Operation voltage between VDD and VSS VDSOP1 Internal circuit operating voltage 1.5  8 V  
Operation voltage between VDD and VM VDSOP2 Internal circuit operating voltage 1.5  28 V  
CURRENT CONSUMPTION (with power-down function)
Current consumption in normal operation IOPE VDD = 3.5 V, VVM = 0 V 1.0 3.5 7.0 µA 5 2
Current consumption at power down IPDN VDD = VVM = 1.5 V   0.1 µA 5 2
CURRENT CONSUMPTION (without power-down function)
Current consumption in normal operation IOPE VDD = 3.5 V, VVM = 0 V 1.0 3.5 7.0 µA 5 2
Overdischarge current consumption IOPED VDD = VVM = 1.5 V 1.0 3.0 5.5 µA 5 2
OUTPUT RESISTANCE
CO pin resistance “H” RCOH VCO = 3.0 V, VDD = 3.5 V, VVM = 0 V 2.5 5 10 kΩ 7 4
CO pin resistance “L” RCOL VCO = 0.5 V, VDD = 4.5 V, VVM = 0 V 2.5 5 10 kΩ 7 4
DO pin resistance “H” RDOH VDO = 3.0 V, VDD = 3.5 V, VVM = 0 V 2.5 5 10 kΩ 8 4
DO pin resistance “L” RDOL VDO = 0.5 V, VDD = VVM = 1.8 V 2.5 5 10 kΩ 8 4
VM INTERNAL RESISTANCE
Internal resistance between VM and VDD RVMD VDD = 1.8 V, VVM = 0 V 100 300 900 kΩ 6 3
Internal resistance between VM and VSS RVMS VDD = 3.5 V, VVM = 1.0 V 10 20 40 kΩ 6 3
0 V BATTERY CHARGING FUNCTION
0 V battery charge starting charger voltage V0CHA 0 V battery charging available 1.2   V 11 2
0 V battery charge inhibition battery voltage V0INH 0 V battery charging unavailable   0.5 V 12 2
*1. Since products are not screened at high and low temperatures, the specification for this temperature range is guaranteed
by design, not tested in production.

8 Seiko Instruments Inc.


BATTERY PROTECTION IC FOR 1-CELL PACK
Rev.4.6_00 S-8261 Series

2. Except Detection Delay Time (−40°C to +85°C*1)


Table 7
(Ta = −40°C to +85°C*1 unless otherwise specified)
Test Test
Item Symbol Condition Min. Typ. Max. Unit
Condition Circuit
DETECTION VOLTAGE
Overcharge detection voltage VCU VCU
VCU  VCU V 1 1
VCU = 3.9 V to 4.4 V, 5 mV Step −0.055 +0.040
Overcharge hysteresis voltage VHC VHC
VHC  VHC V 1 1
VHC = 0.1 V to 0.4 V, 50 mV Step −0.025 +0.025
Overdischarge detection voltage VDL VDL
VDL  VDL V 2 2
VDL = 2.0 V to 3.0 V, 10 mV Step −0.080 +0.080
Overdischarge hysteresis voltage VHD VHD
VHD  VHD V 2 2
VHD = 0.0 V to 0.7 V, 100 mV Step −0.050 +0.050
Overcurrent 1 detection voltage VIOV1 VIOV1
VIOV1  VIOV1 V 3 2
VIOV1 = 0.05 V to 0.3 V, 10 mV Step −0.021 +0.021
Overcurrent 2 detection voltage VIOV2  0.37 0.5 0.63 V 3 2
Load short-circuiting detection voltage VSHORT  0.7 1.2 1.7 V 3 2
Charger detection voltage VCHA  −1.2 −0.7 −0.2 V 4 2
INPUT VOLTAGE, OPERATION VOLTAGE
Operation voltage between VDD and VSS VDSOP1 Internal circuit operating voltage 1.5  8 V  
Operation voltage between VDD and VM VDSOP2 Internal circuit operating voltage 1.5  28 V  
CURRENT CONSUMPTION (with power-down function)
Current consumption in normal operation IOPE VDD = 3.5 V, VVM = 0 V 0.7 3.5 8.0 µA 5 2
Current consumption at power down IPDN VDD = VVM = 1.5 V   0.1 µA 5 2
CURRENT CONSUMPTION (without power-down function)
Current consumption in normal operation IOPE VDD = 3.5 V, VVM = 0 V 0.7 3.5 8.0 µA 5 2
Overdischarge current consumption IOPED VDD = VVM = 1.5 V 0.7 3.0 6.0 µA 5 2
OUTPUT RESISTANCE
CO pin resistance “H” RCOH VCO = 3.0 V, VDD = 3.5 V, VVM = 0 V 1.2 5 15 kΩ 7 4
CO pin resistance “L” RCOL VCO = 0.5 V, VDD = 4.5 V, VVM = 0 V 1.2 5 15 kΩ 7 4
DO pin resistance “H” RDOH VDO = 3.0 V, VDD = 3.5 V, VVM = 0 V 1.2 5 15 kΩ 8 4
DO pin resistance “L” RDOL VDO = 0.5 V, VDD = VVM = 1.8 V 1.2 5 15 kΩ 8 4
VM INTERNAL RESISTANCE
Internal resistance between VM and VDD RVMD VDD = 1.8 V, VVM = 0 V 78 300 1310 kΩ 6 3
Internal resistance between VM and VSS RVMS VDD = 3.5 V, VVM = 1.0 V 7.2 20 44 kΩ 6 3
0 V BATTERY CHARGING FUNCTION
0 V battery charge starting charger voltage V0CHA 0 V battery charging available 1.7   V 11 2
0 V battery charge inhibition battery voltage V0INH 0 V battery charging unavailable   0.3 V 12 2
*1. Since products are not screened at high and low temperatures, the specification for this temperature range is guaranteed
by design, not tested in production.

Seiko Instruments Inc. 9


BATTERY PROTECTION IC FOR 1-CELL PACK
S-8261 Series Rev.4.6_00

3. Detection Delay Time


(1) S-8261AAG, S-8261AAH, S-8261AAJ, S-8261AAL, S-8261AAM, S-8261AAN, S-8261AAO, S-8261AAP,
S-8261AAR, S-8261AAZ, S-8261ABB, S-8261ABC, S-8261ABJ, S-8261ABK, S-8261ABM, S-8261ABN,
S-8261ABP, S-8261ABR, S-8261ABS, S-8261ACB, S-8261ACE, S-8261ACI, S-8261ACK, S-8261ACM,
S-8261ACJ, S-8261ACN

Table 8

Test Test
Item Symbol Condition Min. Typ. Max. Unit
Condition Circuit
DELAY TIME (Ta = 25°C)
Overcharge detection delay time tCU  0.96 1.2 1.4 s 9 5
Overdischarge detection delay time tDL  115 144 173 ms 9 5
Overcurrent 1 detection delay time tlOV1  7.2 9 11 ms 10 5
Overcurrent 2 detection delay time tlOV2  1.8 2.24 2.7 ms 10 5
Load short-circuiting detection delay time tSHORT  220 320 380 µs 10 5
DELAY TIME (Ta = −40°C to +85°C) *1
Overcharge detection delay time tCU  0.7 1.2 2.0 s 9 5
Overdischarge detection delay time tDL  80 144 245 ms 9 5
Overcurrent 1 detection delay time tlOV1  5 9 15 ms 10 5
Overcurrent 2 detection delay time tlOV2  1.2 2.24 3.8 ms 10 5
Load short-circuiting detection delay time tSHORT  150 320 540 µs 10 5
*1. Since products are not screened at high and low temperatures, the specification for this temperature range is guaranteed by design, not
tested in production.

(2) S-8261AAS

Table 9

Test Test
Item Symbol Condition Min. Typ. Max. Unit
Condition Circuit
DELAY TIME (Ta = 25°C)
Overcharge detection delay time tCU  0.96 1.2 1.4 s 9 5
Overdischarge detection delay time tDL  115 144 173 ms 9 5
Overcurrent 1 detection delay time tlOV1  3.6 4.5 5.4 ms 10 5
Overcurrent 2 detection delay time tlOV2  1.8 2.24 2.7 ms 10 5
Load short-circuiting detection delay time tSHORT  220 320 380 µs 10 5
DELAY TIME (Ta = −40°C to +85°C) *1
Overcharge detection delay time tCU  0.7 1.2 2.0 s 9 5
Overdischarge detection delay time tDL  80 144 245 ms 9 5
Overcurrent 1 detection delay time tlOV1  2.5 4.5 7.7 ms 10 5
Overcurrent 2 detection delay time tlOV2  1.2 2.24 3.8 ms 10 5
Load short-circuiting detection delay time tSHORT  150 320 540 µs 10 5
*1. Since products are not screened at high and low temperatures, the specification for this temperature range is guaranteed by design, not
tested in production.

10 Seiko Instruments Inc.


BATTERY PROTECTION IC FOR 1-CELL PACK
Rev.4.6_00 S-8261 Series

(3) S-8261AAT

Table 10

Test Test
Item Symbol Condition Min. Typ. Max. Unit
Condition Circuit
DELAY TIME (Ta = 25°C)
Overcharge detection delay time tCU  3.7 4.6 5.5 s 9 5
Overdischarge detection delay time tDL  29 36 43 ms 9 5
Overcurrent 1 detection delay time tlOV1  14 18 22 ms 10 5
Overcurrent 2 detection delay time tlOV2  7.2 9 11 ms 10 5
Load short-circuiting detection delay time tSHORT  220 320 380 µs 10 5
*1
DELAY TIME (Ta = −40°C to +85°C)
Overcharge detection delay time tCU  2.5 4.6 7.8 s 9 5
Overdischarge detection delay time tDL  20 36 61 ms 9 5
Overcurrent 1 detection delay time tlOV1  10 18 31 ms 10 5
Overcurrent 2 detection delay time tlOV2  5 9 15 ms 10 5
Load short-circuiting detection delay time tSHORT  150 320 540 µs 10 5
*1. Since products are not screened at high and low temperatures, the specification for this temperature range is guaranteed by design, not
tested in production.

(4) S-8261AAU, S-8261AAX, S-8261ABA

Table 11

Test Test
Item Symbol Condition Min. Typ. Max. Unit
Condition Circuit
DELAY TIME (Ta = 25°C)
Overcharge detection delay time tCU  3.7 4.6 5.5 s 9 5
Overdischarge detection delay time tDL  115 144 173 ms 9 5
Overcurrent 1 detection delay time tlOV1  7.2 9 11 ms 10 5
Overcurrent 2 detection delay time tlOV2  1.8 2.24 2.7 ms 10 5
Load short-circuiting detection delay time tSHORT  220 320 380 µs 10 5
DELAY TIME (Ta = −40°C to +85°C) *1
Overcharge detection delay time tCU  2.5 4.6 7.8 s 9 5
Overdischarge detection delay time tDL  80 144 245 ms 9 5
Overcurrent 1 detection delay time tlOV1  5 9 15 ms 10 5
Overcurrent 2 detection delay time tlOV2  1.2 2.24 3.8 ms 10 5
Load short-circuiting detection delay time tSHORT  150 320 540 µs 10 5
*1. Since products are not screened at high and low temperatures, the specification for this temperature range is guaranteed by design, not
tested in production.

Seiko Instruments Inc. 11


BATTERY PROTECTION IC FOR 1-CELL PACK
S-8261 Series Rev.4.6_00

(5) S-8261ABI, S-8261ABL, S-8261ABT

Table 12

Test Test
Item Symbol Condition Min. Typ. Max. Unit
condition circuit
DELAY TIME (Ta = 25°C)
Overcharge detection delay time tCU  0.96 1.2 1.4 s 9 5
Overdischarge detection delay time tDL  29 36 43 ms 9 5
Overcurrent 1 detection delay time tlOV1  7.2 9 11 ms 10 5
Overcurrent 2 detection delay time tlOV2  1.8 2.24 2.7 ms 10 5
Load short-circuiting detection delay time tSHORT  220 320 380 µs 10 5
*1
DELAY TIME (Ta = −40°C to +85°C)
Overcharge detection delay time tCU  0.7 1.2 2.0 s 9 5
Overdischarge detection delay time tDL  20 36 61 ms 9 5
Overcurrent 1 detection delay time tlOV1  5 9 15 ms 10 5
Overcurrent 2 detection delay time tlOV2  1.2 2.24 3.8 ms 10 5
Load short-circuiting detection delay time tSHORT  150 320 540 µs 10 5
*1. Since products are not screened at high and low temperatures, the specification for this temperature range is guaranteed by design, not
tested in production.

(6) S-8261ABY, S-8261ABZ, S-8261ACA

Table 13

Test Test
Item Symbol Condition Min. Typ. Max. Unit
Condition Circuit
DELAY TIME (Ta = 25°C)
Overcharge detection delay time tCU  0.96 1.2 1.4 s 9 5
Overdischarge detection delay time tDL  115 144 173 ms 9 5
Overcurrent 1 detection delay time tlOV1  7.2 9 11 ms 10 5
Overcurrent 2 detection delay time tlOV2  0.89 1.12 1.35 ms 10 5
Load short-circuiting detection delay time tSHORT  220 320 380 µs 10 5
DELAY TIME (Ta = −40°C to +85°C) *1
Overcharge detection delay time tCU  0.7 1.2 2.0 s 9 5
Overdischarge detection delay time tDL  80 144 245 ms 9 5
Overcurrent 1 detection delay time tlOV1  5 9 15 ms 10 5
Overcurrent 2 detection delay time tlOV2  0.61 1.12 1.91 ms 10 5
Load short-circuiting detection delay time tSHORT  150 320 540 µs 10 5
*1. Since products are not screened at high and low temperatures, the specification for this temperature range is guaranteed by design, not
tested in production.

12 Seiko Instruments Inc.


BATTERY PROTECTION IC FOR 1-CELL PACK
Rev.4.6_00 S-8261 Series

(7) S-8261ACD

Table 14

Test Test
Item Symbol Condition Min. Typ. Max. Unit
Condition Circuit
DELAY TIME (Ta = 25°C)
Overcharge detection delay time tCU  0.96 1.2 1.4 s 9 5
Overdischarge detection delay time tDL  232 290 348 ms 9 5
Overcurrent 1 detection delay time tlOV1  14 18 22 ms 10 5
Overcurrent 2 detection delay time tlOV2  1.8 2.24 2.7 ms 10 5
Load short-circuiting detection delay time tSHORT  220 320 380 µs 10 5
*1
DELAY TIME (Ta = −40°C to +85°C)
Overcharge detection delay time tCU  0.7 1.2 2.0 s 9 5
Overdischarge detection delay time tDL  160 290 493 ms 9 5
Overcurrent 1 detection delay time tlOV1  10 18 31 ms 10 5
Overcurrent 2 detection delay time tlOV2  1.2 2.24 3.8 ms 10 5
Load short-circuiting detection delay time tSHORT  150 320 540 µs 10 5
*1. Since products are not screened at high and low temperatures, the specification for this temperature range is guaranteed by design, not
tested in production.

(8) S-8261ACF

Table 15

Test Test
Item Symbol Condition Min. Typ. Max. Unit
Condition Circuit
DELAY TIME (Ta = 25°C)
Overcharge detection delay time tCU  0.96 1.2 1.4 s 9 5
Overdischarge detection delay time tDL  115 144 173 ms 9 5
Overcurrent 1 detection delay time tlOV1  14 18 22 ms 10 5
Overcurrent 2 detection delay time tlOV2  1.8 2.24 2.7 ms 10 5
Load short-circuiting detection delay time tSHORT  220 320 380 µs 10 5
DELAY TIME (Ta = −40°C to +85°C) *1
Overcharge detection delay time tCU  0.7 1.2 2.0 s 9 5
Overdischarge detection delay time tDL  80 144 245 ms 9 5
Overcurrent 1 detection delay time tlOV1  10 18 31 ms 10 5
Overcurrent 2 detection delay time tlOV2  1.2 2.24 3.8 ms 10 5
Load short-circuiting detection delay time tSHORT  150 320 540 µs 10 5
*1. Since products are not screened at high and low temperatures, the specification for this temperature range is guaranteed by design, not
tested in production.

Seiko Instruments Inc. 13


BATTERY PROTECTION IC FOR 1-CELL PACK
S-8261 Series Rev.4.6_00

(9) S-8261ACH

Table 16

Test Test
Item Symbol Condition Min. Typ. Max. Unit
Condition Circuit
DELAY TIME (Ta = 25°C)
Overcharge detection delay time tCU  0.24 0.3 0.36 s 9 5
Overdischarge detection delay time tDL  29 36 43 ms 9 5
Overcurrent 1 detection delay time tlOV1  7.2 9 11 ms 10 5
Overcurrent 2 detection delay time tlOV2  0.89 1.12 1.35 ms 10 5
Load short-circuiting detection delay time tSHORT  220 320 380 µs 10 5
*1
DELAY TIME (Ta = −40°C to +85°C)
Overcharge detection delay time tCU  0.17 0.3 0.51 s 9 5
Overdischarge detection delay time tDL  20 36 61 ms 9 5
Overcurrent 1 detection delay time tlOV1  5 9 15 ms 10 5
Overcurrent 2 detection delay time tlOV2  0.61 1.12 1.91 ms 10 5
Load short-circuiting detection delay time tSHORT  150 320 540 µs 10 5
*1. Since products are not screened at high and low temperatures, the specification for this temperature range is guaranteed by design, not
tested in production.

14 Seiko Instruments Inc.


BATTERY PROTECTION IC FOR 1-CELL PACK
Rev.4.6_00 S-8261 Series

„ Test Circuits

Caution Unless otherwise specified, the output voltage levels “H” and “L” at CO pin (VCO) and DO pin (VDO) are
judged by the threshold voltage (1.0 V) of the N-channel FET. Judge the CO pin level with respect to
VVM and the DO pin level with respect to VSS.

(1) Test Condition 1, Test Circuit 1


(Overcharge Detection Voltage, Overcharge Hysteresis Voltage)
The overcharge detection voltage (VCU) is defined as the voltage between VDD and VSS at which VCO goes from “H”
to “L” when the voltage V1 is gradually increased from the starting condition of V1 = 3.5 V. The overcharge
hysteresis voltage (VHC) is then defined as the difference between the overcharge detection voltage (VCU) and the
voltage between VDD and VSS at which VCO goes from “L” to “H” when the voltage V1 is gradually decreased.

(2) Test Condition 2, Test Circuit 2


(Overdischarge Detection Voltage, Overdischarge Hysteresis Voltage)
The overdischarge detection voltage (VDL) is defined as the voltage between VDD and VSS at which VDO goes from
“H” to “L” when the voltage V1 is gradually decreased from the starting condition of V1 = 3.5 V and V2 = 0 V. The
overdischarge hysteresis voltage (VHD) is then defined as the difference between the overdischarge detection voltage
(VDL) and the voltage between VDD and VSS at which VDO goes from “L” to “H” when the voltage V1 is gradually
increased.

(3) Test Condition 3, Test Circuit 2


(Overcurrent 1 Detection Voltage, Overcurrent 2 Detection Voltage, Load Short-Circuiting Detection Voltage)
The overcurrent 1 detection voltage (VIOV1) is defined as the voltage between VM and VSS whose delay time for
changing VDO from “H” to “L” lies between the minimum and the maximum value of the overcurrent 1 detection delay
time when the voltage V2 is increased rapidly (within 10 µs) from the starting condition V1 = 3.5 V and V2 = 0 V.
The overcurrent 2 detection voltage (VIOV2) is defined as the voltage between VM and VSS whose delay time for
changing VDO from “H” to “L” lies between the minimum and the maximum value of the overcurrent 2 detection delay
time when the voltage V2 is increased rapidly (within 10 µs) from the starting condition V1 = 3.5 V and V2 = 0 V.
The load short-circuiting detection voltage (VSHORT) is defined as the voltage between VM and VSS whose delay time
for changing VDO from “H” to “L” lies between the minimum and the maximum value of the load short-circuiting
detection delay time when the voltage V2 is increased rapidly (within 10 µs) from the starting condition V1 = 3.5 V and
V2 = 0 V.

(4) Test Condition 4, Test Circuit 2


(Charger Detection Voltage, Abnormal Charge Current Detection Voltage)
The charger detection voltage (VCHA) is defined as the voltage between VM and VSS at which VDO goes from “L” to “H”
when the voltage V2 is gradually decreased from 0 V after the voltage V1 is gradually increased from the starting
condition of V1 = 1.8 V and V2 = 0 V until the voltage V1 becomes V1 = VDL + (VHD / 2).
The charger detection voltage can be measured only in the product whose overdischarge hysteresis VHD ≠ 0.
Set V1 = 3.5 V and V2 = 0 V. Decrease V2 from 0 V gradually. The voltage between VM and VSS when VCO goes
from “H” to “L” is the abnormal charge current detection voltage. The abnormal charge current detection voltage has
the same value as the charger detection voltage (VCHA).

(5) Test Condition 5, Test Circuit 2


(Normal Operation Current Consumption, Power-Down Current Consumption, Overdischarge Current Consumption)

For products with power-down function


The operating current consumption (IOPE) is the current that flows through the VDD pin (IDD) under the set conditions of
V1 = 3.5 V and V2 = 0 V (Normal status).
The power-down current consumption (IPDN) is the current that flows through the VDD pin (IDD) under the set conditions
of V1 = V2 = 1.5 V (Overdischarge status).
For products without power-down function
The operating current consumption (IOPE) is the current that flows through the VDD pin (IDD) under the set conditions of
V1 = 3.5 V and V2 = 0 V (Normal status).
The Overdischarge current consumption (IOPED) is the current that flows through the VDD pin (IDD) under the set
conditions of V1 = V2 = 1.5 V (Overdischarge status).

Seiko Instruments Inc. 15


BATTERY PROTECTION IC FOR 1-CELL PACK
S-8261 Series Rev.4.6_00

(6) Test Condition 6, Test Circuit 3


(Internal Resistance between VM and VDD, Internal Resistance between VM and VSS)
The resistance between VM and VDD (RVMD) is the internal resistance between VM and VDD under the set conditions
of V1 = 1.8 V and V2 = 0 V.
The resistance between VM and VSS (RVMS) is the internal resistance between VM and VSS under the set conditions
of V1 = 3.5 V and V2 = 1.0 V.

(7) Test Condition 7, Test Circuit 4


(CO Pin Resistance “H”, CO Pin Resistance “L”)
The CO pin resistance “H” (RCOH) is the resistance the CO pin under the set condition of V1 = 3.5 V, V2 = 0 V and V3
= 3.0 V.
The CO pin resistance “L” (RCOL) is the resistance the CO pin under the set condition of V1 = 4.5 V, V2 = 0 V and V3 =
0.5 V.

(8) Test Condition 8, Test Circuit 4


(DO Pin Resistance “H”, DO Pin Resistance “L”)
The DO pin resistance “H” (RDOH) is the resistance the DO pin under the set condition of V1 = 3.5 V, V2 = 0 V and V4
= 3.0 V.
The DO pin resistance “L” (RDOL) is the resistance the DO pin under the set condition of V1 = 1.8 V, V2 = 0 V and V4 =
0.5 V.

(9) Test Condition 9, Test Circuit 5


(Overcharge Detection Delay Time, Overdischarge Detection Delay Time)
The overcharge detection delay time (tCU) is the time needed for VCO to change from “H” to “L” just after the voltage V1
momentarily increases (within 10 µs) from the overcharge detection voltage (VCU) − 0.2 V to the overcharge detection
voltage (VCU) + 0.2 V under the set condition of V2 = 0 V.
The overdischarge detection delay time (tDL) is the time needed for VDO to change from “H” to “L” just after the voltage
V1 momentarily decreases (within 10 µs) from the overdischarge detection voltage (VDL) +0.2 V to the overdischarge
detection voltage (VDL) − 0.2 V under the set condition of V2 = 0 V.

(10) Test Condition 10, Test Circuit 5


(Overcurrent 1 Detection Delay Time, Overcurrent 2 Detection Delay Time, Load Short-circuiting Detection
Delay Time, Abnormal Charge Current Detection Delay Time)
The overcurrent 1 detection delay time (tIOV1) is the time needed for VDO to go “L” after the voltage V2 momentarily
increases (within 10 µs) from 0 V to 0.35 V under the set condition of V1 = 3.5 V and V2=0 V.
The overcurrent 2 detection delay time (tIOV2) is the time needed for VDO to go “L” after the voltage V2 momentarily
increases (within 10 µs) from 0 V to 0.7 V under the set condition of V1 = 3.5 V and V2 = 0 V.
The load short-circuiting detection delay time (tSHORT) is the time needed for VDO to go “L” after the voltage V2
momentarily increases (within 10 µs) from 0 V to 1.6 V under the set condition of V1 = 3.5 V and V2 = 0 V.
The abnormal charge current detection delay time is the time needed for VCO to go from “H” to “L” after the voltage V2
momentarily decreases (within 10 µs) from 0 V to −1.1 V under the set condition of V1 = 3.5 V and V2 = 0 V. The
abnormal charge current detection delay time has the same value as the overcharge detection delay time.

(11) Test Condition 11, Test Circuit 2 (Product with 0 V battery charge function)
(0 V Battery Charge Starting Charger Voltage)
The 0 V battery charge starting charger voltage (V0CHA) is defined as the voltage between VDD and VM at which VCO
goes “H” (VVM + 0.1 V or higher) when the voltage V2 is gradually decreased from the starting condition of V1 = V2 = 0
V.

(12) Test Condition 12, Test Circuit 2 (Product with 0 V battery charge inhibition function)
(0 V Battery Charge Inhibition Battery Voltage)
The 0 V battery charge inhibition battery voltage (V0INH) is defined as the voltage between VDD and VSS at which VCO
goes “H” (VVM + 0.1 V or higher) when the voltage V1 is gradually increased from the starting condition of V1 = 0 V and
V2 = −4 V.

16 Seiko Instruments Inc.


BATTERY PROTECTION IC FOR 1-CELL PACK
Rev.4.6_00 S-8261 Series

R1 = 470 Ω IDD
VDD
A VDD DP
DP

S-8261 Series V1 S-8261 Series


V1
VM VM
VSS VSS
DO CO DO CO

V2
V VDO V VCO V VDO V VCO

COM COM
Test Circuit 1 Test Circuit 2

IDD
A VDD DP VDD DP

S-8261 Series V1 S-8261 Series


V1

VM VM
VSS VSS
DO CO A IVM DO CO

A IDO A ICO V2
V2
V4 V3

COM COM
Test Circuit 3 Test Circuit 4

VDD DP

S-8261 Series
V1
VM
VSS
DO CO

V2
Oscilloscope Oscilloscope

COM
Test Circuit 5
Figure 4

Seiko Instruments Inc. 17


BATTERY PROTECTION IC FOR 1-CELL PACK
S-8261 Series Rev.4.6_00

„ Operation

Remark Refer to “„ Battery Protection IC Connection Example”.

1. Normal Status
The S-8261 Series monitors the voltage of the battery connected between VDD pin and VSS pin and the voltage
difference between VM pin and VSS pin to control charging and discharging. When the battery voltage is in the range
from the overdischarge detection voltage (VDL) to the overcharge detection voltage (VCU), and the VM pin voltage is in
the range from the charger detection voltage (VCHA) to the overcurrent 1 detection voltage (VIOV1), the IC turns both the
charging and discharging control FETs on. This status is called the normal status, and in this status charging and
discharging can be carried out freely.
Caution When a battery is connected to the IC for the first time, discharging may not be enabled. In this
case, short the VM pin and VSS pin or connect the charger to restore the normal condition.

2. Overcurrent Status (Detection of Overcurrent 1, Overcurrent 2 and Load Short-circuiting)


When a battery in the normal status is in the status where the voltage of the VM pin is equal to or higher than the
overcurrent detection voltage because the discharge current is higher than the specified value and the status lasts for
the overcurrent detection delay time, the discharge control FET is turned off and discharging is stopped. This status is
called the overcurrent status.
In the overcurrent status, the VM and VSS pins are shorted by the resistor between VM and VSS (RVMS) in the IC.
However, the voltage of the VM pin is at the VDD potential due to the load as long as the load is connected. When the
load is disconnected, the VM pin returns to the VSS potential.
This IC detects the status when the impedance between the EB+ pin and EB− pin (Refer to Figure 10) increases and is
equal to the impedance that enables automatic restoration and the voltage at the VM pin returns to overcurrent 1
detection voltage (VIOV1) or lower and the overcurrent status is restored to the normal status.
Caution The impedance that enables automatic restoration varies depending on the battery voltage and the
set value of overcurrent 1 detection voltage.

3. Overcharge Status
When the battery voltage becomes higher than the overcharge detection voltage (VCU) during charging under the
normal status and the detection continues for the overcharge detection delay time (tCU) or longer, the S-8261 Series
turns the charging control FET off to stop charging. This status is called the overcharge status.
The overcharge status is released by the following two cases ((1) and (2)):

(1) When the battery voltage falls below the overcharge release voltage (VCU) − overcharge detection hysteresis
voltage (VHC), the S-8261 Series turns the charging control FET on and turns to the normal status.
(2) When a load is connected and discharging starts, the S-8261 Series turns the charging control FET on and returns
to the normal status. Just after the load is connected and discharging starts, the discharging current flows through
the parasitic diode in the charging control FET. At this moment the VM pin potential becomes Vf, the voltage for
the parasitic diode, higher than VSS level. When the battery voltage goes under the overcharge detection voltage
(VCU) and provided that the VM pin voltage is higher than the overcurrent 1 detection voltage, the S-8261 Series
releases the overcharge status.

Caution 1. If the battery is charged to a voltage higher than the overcharge detection voltage (VCU) and the
battery voltage does not fall below the overcharge detection voltage (VCU) even when a heavy load
is connected, the detection of overcurrent 1, overcurrent 2 and load short-circuiting do not
function until the battery voltage falls below overcharge detection voltage (VCU). Since an actual
battery has an internal impedance of several dozens of mΩ, the battery voltage drops immediately
after a heavy load that causes overcurrent is connected, and the detection of overcurrent 1,
overcurrent 2 and load short-circuiting function.
2. When a charger is connected after the overcharge detection, the overcharge status is not released
even if the battery voltage is below the overcharge release voltage (VCL). The overcharge status is
released when the VM pin voltage goes over the charger detection voltage (VCHA) by removing the
charger.

18 Seiko Instruments Inc.


BATTERY PROTECTION IC FOR 1-CELL PACK
Rev.4.6_00 S-8261 Series

4. Overdischarge Status
For products with power-down function
When the battery voltage falls below the overdischarge detection voltage (VDL) during discharging under the normal
status and the detection continues for the overdischarge detection delay time (tDL) or longer, the S-8261 Series turns
the discharging control FET off to stop discharging. This status is called the overdischarge status. When the
discharging control FET is turned off, the VM pin voltage is pulled up by the resistor between VM and VDD in the IC
(RVMD). When the voltage difference between the VM and VDD then is 1.3 V (typ.) or lower, the current consumption
is reduced to the power-down current consumption (IPDN). This status is called the power-down status.
The power-down status is released when a charger is connected and the voltage difference between the VM and VDD
becomes 1.3 V (typ.) or higher. Moreover when the battery voltage becomes the overdischarge detection voltage
(VDL) or higher, the S-8261 Series turns the discharging FET on and returns to the normal status.
For products without power-down function
When the battery voltage falls below the overdischarge detection voltage (VDL) during discharging under the normal
status and the detection continues for the overdischarge detection delay time (tDL) or longer, the S-8261 Series turns
the discharging control FET off to stop discharging. This status is called the overdischarge status. When the
discharging control FET is turned off, the VM pin voltage is pulled up by the resistor between VM and VDD in the IC
(RVMD).
When the battery voltage becomes the overdischarge detection voltage (VDL) or higher, the S-8261 Series turns the
discharging FET on and returns to the normal status.

5. Charger Detection
When a battery in the overdischarge status is connected to a charger and provided that the VM pin voltage is lower
than the charger detection voltage (VCHA), the S-8261 Series releases the overdischarge status and turns the
discharging control FET on when the battery voltage becomes equal to or higher than the overdischarge detection
voltage (VDL) since the charger detection function works. This action is called charger detection.
When a battery in the overdischarge status is connected to a charger and provided that the VM pin voltage is not lower
than the charger detection voltage (VCHA), the S-8261 Series releases the overdischarge status when the battery
voltage reaches the overdischarge detection voltage (VDL) + overdischarge hysteresis (VHD) or higher.

6. Abnormal Charge Current Detection


If the VM pin voltage falls below the charger detection voltage (VCHA) during charging under normal status and it
continues for the overcharge detection delay time (tCU) or longer, the charging control FET turns off and charging stops.
This action is called the abnormal charge current detection.
Abnormal charge current detection works when the DO pin voltage is “H” and the VM pin voltage falls below the
charger detection voltage (VCHA). Consequently, if an abnormal charge current flows to an over-discharged battery,
the S-8261 Series turns the charging control FET off and stops charging after the battery voltage becomes higher than
the overdischarge detection voltage which make the DO pin voltage “H”, and still after the overcharge detection delay
time (tCU) elapses.
Abnormal charge current detection is released when the voltage difference between VM pin and VSS pin becomes less
than charger detection voltage (VCHA).

Seiko Instruments Inc. 19


BATTERY PROTECTION IC FOR 1-CELL PACK
S-8261 Series Rev.4.6_00

7. Delay Circuits
The detection delay times are determined by dividing a clock of the approximately 3.5 kHz with the counter.

Remark 1. The detection delay time for overcurrent 2 (tIOV2) and load short-circuiting (tSHORT) start when the
overcurrent 1 (VIOV1) is detected. When the overcurrent 2 (VIOV2) or load short-circuiting (VSHORT) is
detected over the detection delay time for each of them (= tIOV2 or tSHORT) after the detection of overcurrent
1 (VIOV1), the S-8261 Series turns the FET off within tIOV2 or tSHORT of each detection.

VDD

DO pin
tD 0 ≤ tD ≤ tIOV2
VSS

Overcurrent 2 detection delay time (tIOV2) Time


VDD

VIOV2
VM pin
VIOV1

VSS
Time
Figure 5

2. For products with power-down function


When the overcurrent is detected and continues for longer than the overdischarge detection delay time
(tDL) without releasing the load, the status changes to the power-down status when the battery voltage falls
below the overdischarge detection voltage (VDL). When the battery voltage falls below the overdischarge
detection voltage (VDL) due to the overcurrent, the S-8261 Series turns the discharging control FET off by
the overcurrent detection. In this case if the recovery of the battery voltage is so slow that the battery
voltage after the overdischarge detection delay time (tDL) is still lower than the overdischarge detection
voltage (VDL), the S-8261 Series shifts to the power-down status.
For products without power-down function
When the overcurrent is detected and continues for longer than the overdischarge detection delay time
(tDL) without released the load, the status changes to the overdischarge status when the battery voltage
falls below overdischarge detection voltage (VDL).When the battery voltage falls below overdischarge
detection voltage (VDL) due to the overcurrent, the S-8261 Series turns the discharging control FET off by
the overcurrent detection. In this case, if the recovery of the battery voltage is so slow that the battery
voltage after the overdischarge detection delay time (tDL) is still lower than the overdischarge detection
voltage (VDL), S-8261 Series shifts to the overdischarge status.

20 Seiko Instruments Inc.


BATTERY PROTECTION IC FOR 1-CELL PACK
Rev.4.6_00 S-8261 Series

8. DP Pin
The DP pin is a test pin for delay time measurement and it should be open in the actual application. If a capacitor
whose capacitance is larger than 1000 pF or a resistor whose resistance is less than 1 MΩ is connected to this pin,
error may occur in the delay times or in the detection voltages.

9. 0 V Battery Charging Function “Available”


This function is used to recharge the connected battery whose voltage is 0 V due to the self-discharge. When the 0 V
battery charge starting charger voltage (V0CHA) or higher is applied between EB+ pin and EB− pin by connecting a
charger, the charging control FET gate is fixed to VDD pin voltage. When the voltage between the gate and source of
the charging control FET becomes equal to or higher than the turn-on voltage due to the charger voltage, the charging
control FET is turned on to start charging. At this time, the discharging control FET is off and the charging current
flows through the internal parasitic diode in the discharging control FET. When the battery voltage becomes equal to
or higher than the overdischarge detection voltage (VDL) and the overdischarge hysteresis voltage (VHD), the S-8261
Series enters the normal status.

Caution Some battery providers do not recommend charging for completely self-discharged battery. Please
ask battery providers before determine whether to enable or inhibit the 0 V battery charging
function.

Remark The 0 V battery charge function has higher priority than the abnormal charge current detection function.
Consequently, a product with the 0 V battery charging function is enabled charges a battery forcibly and
abnormal charge current cannot be detected when the battery voltage is low.

10. 0 V Battery Charging Function “Unavailable”


This function inhibits the recharging when a battery that is short-circuited (0 V battery) internally is connected. When
the battery voltage is the 0 V battery charge inhibition battery voltage (V0INH) or lower, the charging control FET gate is
fixed to EB− pin voltage to inhibit charging. When the battery voltage is the 0 V battery charge inhibition battery
voltage (V0INH) or higher, charging can be performed.

Caution Some battery providers do not recommend charging for completely self-discharged battery. Please
ask battery providers before determining the 0 V battery charging function.

Seiko Instruments Inc. 21


BATTERY PROTECTION IC FOR 1-CELL PACK
S-8261 Series Rev.4.6_00

„ Timing Chart

(1) Overcharge and Overdischarge Detection

VCU
Battery VCU–VHC
voltage
VDL+VHD
VDL

VDD
DO pin

VSS

VDD
CO pin

VSS

VDD
VM pin
VIOV1
VSS
VCHA

Charger connection

Load connection
Overcharge detection delay time (tCU) Overdischarge detection delay time (tDL )

Status
(1) (2) (1) (3) (1)

Remark (1) Normal status, (2) Overcharge status, (3) Overdischarge status, (4) Overcurrent status
The charger is supposed to charge with constant current.

Figure 6

(2) Overcurrent Detection


VCU
VCU−VHC
Battery
voltage
VDL+VHD
VDL

VDD
DO pin

VSS

VDD
CO pin

VSS

VDD
VSHORT
VM pin
VIOV2
VIOV1
VSS

Charger connection
Load connection

Overcurrent 1 detection delay time (tIOV1 ) Overcurrent 2 detection delay time (tIOV2 ) Load short-circuiting detection delay time (tSHORT )
Status
(1) (4) (1) (4) (1) (4) (1)

Remark (1) Normal status, (2) Overcharge status, (3) Overdischarge status, (4) Overcurrent status
The charger is supposed to charge with constant current.

Figure 7
22 Seiko Instruments Inc.
BATTERY PROTECTION IC FOR 1-CELL PACK
Rev.4.6_00 S-8261 Series

(3) Charger Detection

VCU
Battery VCU−VHC
voltage
VDL+VHD
VDL

VDD
DO pin

VSS

CO pin VDD

VSS

VM pin VDD

VSS
VCHA
Charger connection

Load connection
In case VM pin voltage < VCHA
Overdischarge detection delay time (tDL ) Overdischarge is released at the overdischarge
detection voltage (VDL )
Status
(1) (3) (1)

Remark (1) Normal status, (2) Overcharge status, (3) Overdischarge status, (4) Overcurrent status
The charger is supposed to charge with constant current.

Figure 8

(4) Abnormal Charge Current Detection

VC U
Battery VC U−VHC
voltage
VD L+VH D
VD L

VD D
DO pin

VSS

VD D
CO pin

VSS

VD D
VM pin

VSS
VC HA

Charger connection
Load connection
Abnormal charging current detection delay time
Overdischarge detection delay time (tD L) ( = Overcharge detection delay time (tCU))
Status
(1) (3) (1) (2) (1)

Remark (1) Normal status, (2) Overcharge status, (3) Overdischarge status, (4) Overcurrent status
The charger is supposed to charge with constant current.

Figure 9

Seiko Instruments Inc. 23


BATTERY PROTECTION IC FOR 1-CELL PACK
S-8261 Series Rev.4.6_00

„ Battery Protection IC Connection Example


EB+
R1 : 470 Ω
VDD DP

Battery C1 :
0.1 µF S-8261 Series

VSS
DO CO VM

R2 : 2 kΩ
FET1 FET2
EB−

Figure 10

Table 17 Constant for External Components

Symbol Part Purpose Typ. Min. Max. Remarks


*1
N-channel Threshold voltage ≤ Overdischarge detection voltage
FET1 Discharge control    *2
MOS FET Gate to source withstanding voltage ≥ Charger voltage
*1
N-channel Threshold voltage ≤ Overdischarge detection voltage
FET2 Charge control    *2
MOS FET Gate to source withstanding voltage ≥ Charger voltage
ESD protection, Resistance should be as small as possible to avoid lowering of
R1 Resistor 470 Ω 300 Ω 1 kΩ
For power fluctuation the overcharge detection accuracy caused by VDD pin current.*3
*4
C1 Capacitor For power fluctuation 0.1 µF 0.022 µF 1.0 µF Install a capacitor of 0.022 µF or higher between VDD and VSS.
Protection for reverse Select a resistance as large as possible to prevent large current
R2 Resistor 2 kΩ 300 Ω 4 kΩ
connection of a charger when a charger is connected in reverse.*5
*1. If the threshold voltage of an FET is low, the FET may not cut the charging current.
If an FET with a threshold voltage equal to or higher than the overdischarge detection voltage is used, discharging
may be stopped before overdischarge is detected.
**2. If the withstanding voltage between the gate and source is lower than the charger voltage, the FET may be destroyed.
*3. If R1 has a high resistance, the voltage between VDD and VSS may exceed the absolute maximum rating when a
charger is connected in reverse since the current flows from the charger to the IC. Insert a resistor of 300 Ω or higher
to R1 for ESD protection.
*4. If a capacitor of less than 0.022 µF is connected to C1, DO may oscillate when load short-circuiting is detected. Be
sure to connect a capacitor of 0.022 µF or higher to C1.
*5. If R2 has a resistance higher than 4 kΩ, the charging current may not be cut when a high-voltage charger is
connected.

Caution 1. The above constants may be changed without notice.


2. The DP pin should be open.
3. It has not been confirmed whether the operation is normal or not in circuits other than the above
example of connection. In addition, the example of connection shown above and the constant do not
guarantee proper operation. Perform through evaluation using the actual application to set the
constant.

24 Seiko Instruments Inc.


BATTERY PROTECTION IC FOR 1-CELL PACK
Rev.4.6_00 S-8261 Series

„ Precautions

• The application conditions for the input voltage, output voltage, and load current should not exceed the package power
dissipation.

• Do not apply an electrostatic discharge to this IC that exceeds the performance ratings of the built-in electrostatic
protection circuit.

• SII claims no responsibility for any and all disputes arising out of or in connection with any infringement by products
including this IC of patents owned by a third party.

Seiko Instruments Inc. 25


BATTERY PROTECTION IC FOR 1-CELL PACK
S-8261 Series Rev.4.6_00

„ Characteristics (Typical Data)

1. Detection / Release Voltage Temperature Characteristics


Overcharge detection voltage vs. temperature Overcharge release voltage vs. temperature
4.44 4.02

4.42 4.00
4.40
VCU [V]

3.98

VCL [V]
4.38 3.96

4.36 3.94
4.34 3.92
−50 −25 0 25 50 75 100 −50 −25 0 25 50 75 100
Ta [°C] Ta [°C]

Overdischarge detection voltage vs. temperature Overdischarge release voltage vs. temperature
3.04 3.44
3.02 3.42
3.00
VDU [V]

3.40
VDL [V]

2.98 3.38

2.96 3.36
2.94 3.34
−50 −25 0 25 50 75 100 −50 −25 0 25 50 75 100
Ta [°C] Ta [°C]

Overcurrent 1 detection voltage vs. temperature Overcurrent 2 detection voltage vs. temperature
0.45 0.65
0.40 0.60
0.35
VIOV1 [V]

VIOV2 [V]

0.55
0.30
0.50
0.25
0.20 0.45

0.15 0.40
−50 −25 0 25 50 75 100 −50 −25 0 25 50 75 100
Ta [°C] Ta [°C]

Load short-circuiting detection voltage vs. temperature


1.5

1.4
VSHORT [V]

1.3

1.2

1.1
1.0
−50 −25 0 25 50 75 100
Ta [°C]

26 Seiko Instruments Inc.


BATTERY PROTECTION IC FOR 1-CELL PACK
Rev.4.6_00 S-8261 Series

2. Current Consumption Temperature Characteristics


Current consumption vs. temperature in normal mode Current consumption vs. temperature in power-down mode
5 0.10

4 0.08

IPDN [µA]
IOPE [µA]

3 0.06

2 0.04
1 0.02
0 0
−50 −25 0 25 50 75 100 −50 −25 0 25 50 75 100
Ta [°C] Ta [°C]

3. Current Consumption Power Voltage Characteristics (Ta = 25°C)


Current consumption power supply voltage dependency
6
5
4
IOPE [µA]

3
2
1
0
0 2 4 6 8 10 12
VDD [V]

4. Detection / Release Delay Time Temperature Characteristics


Overcharge detection delay time vs. temperature Overcharge release delay time vs. temperature
1.50 60

50
1.25
40
tCL [ms]
tCU [s]

1.00
30
0.75 20
0.50 10
−50 −25 0 25 50 75 100 −50 −25 0 25 50 75 100
Ta [°C] Ta [°C]

Overdischarge detection delay time vs. temperature


200

180
160
tDL [ms]

140
120

100
−50 −25 0 25 50 75 100
Ta [°C]

Seiko Instruments Inc. 27


BATTERY PROTECTION IC FOR 1-CELL PACK
S-8261 Series Rev.4.6_00

Overcurrent 1 detection delay time vs. temperature Overcurrent 2 detection delay time vs. temperature
15 3.4

13 3.0
tIOV1 [ms]

tIOV2 [ms]
11 2.6

9 2.2

7 1.8

5 1.4
−50 −25 0 25 50 75 100 −50 −25 0 25 50 75 100
Ta [°C] Ta [°C]

Load short-circuiting delay time vs. temperature


0.40
0.36
0.32
tSHORT [ms]

0.28
0.24
0.20
0.16
−50 −25 0 25 50 75 100
Ta [°C]

5. Delay Time Power-Voltage Characteristics (Ta = 25°C)


Overcurrent 1 detection delay time vs. power supply voltage dependency Overcurrent 2 detection delay time vs. power supply voltage dependency
15 3.4
13 3.0
tIOV2 [ms]

11 2.6
tIOV1 [V]

9 2.2
7 1.8
5 1.4
2 2.5 3 3.5 4 4.5 2 2.5 3 3.5 4 4.5
VDD [V] VDD [V]

Load short-circuiting delay time vs. power supply voltage dependency


0.32

0.28
tSHORT [ms]

0.24

0.2

0.16
2.5 3 3.5 4 4.5
VDD [V]

28 Seiko Instruments Inc.


BATTERY PROTECTION IC FOR 1-CELL PACK
Rev.4.6_00 S-8261 Series

6. CO Pin / DO Pin Output Current Characteristics (Ta = 25°C)


CO pin source current characteristics VDD = 3.5 V, VM = VSS = 0 V CO pin sink current characteristics VDD = 4.5 V, VM = VSS = 0 V
−0.5 0.5

−0.4 0.4
ICO [mA]

ICO [mA]
−0.3 0.3

−0.2 0.2

−0.1 0.1

0 0
0 1 2 3 4 0 1 2 3 4 5
VCO [V] VCO [V]

DO pin source current characteristics VDD = 3.5 V, VM = VSS = 0 V DO pin sink current characteristics VDD = 1.8 V, VM = VSS = 0 V
−0.5 0.5

−0.4 0.4
IDO [mA]

IDO [mA]

−0.3 0.3

−0.2 0.2

−0.1 0.1

0 0
0 1 2 3 4 0 0.5 1 1.5 2
VDO [V] VDO [V]

Seiko Instruments Inc. 29


2.9±0.2
1.9±0.2

6 5 4

+0.1
1 2 3 0.15 -0.05
0.95 0.95

0.35±0.15

No. MP006-A-P-SD-1.1

TITLE
SOT236-A-PKG Dimensions
No. MP006-A-P-SD-1.1
SCALE
UNIT mm

Seiko Instruments Inc.


4.0±0.1(10 pitches:40.0±0.2)

+0.1 2.0±0.05
ø1.5 -0 0.25±0.1

+0.2 4.0±0.1
ø1.0 -0
1.4±0.2

3.2±0.2

3 2 1

4 5 6

Feed direction

No. MP006-A-C-SD-3.1

TITLE SOT236-A-Carrier Tape

No. MP006-A-C-SD-3.1
SCALE
UNIT mm

Seiko Instruments Inc.


12.5max.

9.0±0.3
Enlarged drawing in the central part

ø13±0.2

(60°) (60°)

No. MP006-A-R-SD-2.1

TITLE SOT236-A-Reel

No. MP006-A-R-SD-2.1
SCALE QTY 3,000
UNIT mm

Seiko Instruments Inc.


• The information described herein is subject to change without notice.
• Seiko Instruments Inc. is not responsible for any problems caused by circuits or diagrams described herein
whose related industrial properties, patents, or other rights belong to third parties. The application circuit
examples explain typical applications of the products, and do not guarantee the success of any specific
mass-production design.
• When the products described herein are regulated products subject to the Wassenaar Arrangement or other
agreements, they may not be exported without authorization from the appropriate governmental authority.
• Use of the information described herein for other purposes and/or reproduction or copying without the
express permission of Seiko Instruments Inc. is strictly prohibited.
• The products described herein cannot be used as part of any device or equipment affecting the human
body, such as exercise equipment, medical equipment, security systems, gas equipment, or any apparatus
installed in airplanes and other vehicles, without prior written permission of Seiko Instruments Inc.
• Although Seiko Instruments Inc. exerts the greatest possible effort to ensure high quality and reliability, the
failure or malfunction of semiconductor products may occur. The user of these products should therefore
give thorough consideration to safety design, including redundancy, fire-prevention measures, and
malfunction prevention, to prevent any accidents, fires, or community damage that may ensue.
P/N: 4-BI010L
JOULES MILES CO., LTD.
Rev. D

SPECIFICATION APPROVAL SHEET Page 69

4. MOSFET Specification
AO8814
Common-Drain Dual N-Channel Enhancement Mode Field
Effect Transistor

General Description Features

The AO8814 uses advanced trench technology to VDS (V) = 20V


provide excellent RDS(ON), low gate charge and ID = 7.5 A (VGS = 10V)
operation with gate voltages as low as 1.8V while RDS(ON) < 16mΩ (VGS = 10V)
retaining a 12V VGS(MAX) rating. It is ESD protected. RDS(ON) < 18mΩ (VGS = 4.5V)
This device is suitable for use as a uni-directional or RDS(ON) < 20mΩ (VGS = 3.6V)
bi-directional load switch, facilitated by its common-
RDS(ON) < 24mΩ (VGS = 2.5V)
drain configuration. Standard Product AO8814is Pb-
free (meets ROHS & Sony 259 specifications). RDS(ON) < 34mΩ (VGS = 1.8V)
ESD Rating: 2500V HBM

D1 D2

TSSOP-8
Top View

D1/D2 1 8 D1/D2
S1 2 7 S2 G1 G2
S1 3 6 S2
G1 4 5 G2

S1 S2

Absolute Maximum Ratings TA=25°C unless otherwise noted


Parameter Symbol Maximum Units
Drain-Source Voltage VDS 20 V
Gate-Source Voltage VGS ±12 V
Continuous Drain TA=25°C 7.5
Current A TA=70°C ID 6 A
B
Pulsed Drain Current IDM 30
TA=25°C 1.5
PD W
Power Dissipation A TA=70°C 0.96
Junction and Storage Temperature Range TJ, TSTG -55 to 150 °C

Thermal Characteristics
Parameter Symbol Typ Max Units
Maximum Junction-to-Ambient A t ≤ 10s 64 83 °C/W
RθJA
Maximum Junction-to-Ambient A Steady-State 89 120 °C/W
Maximum Junction-to-Lead C Steady-State RθJL 53 70 °C/W

Alpha & Omega Semiconductor, Ltd.


AO8814

Electrical Characteristics (T J=25°C unless otherwise noted)

Symbol Parameter Conditions Min Typ Max Units


STATIC PARAMETERS
BVDSS Drain-Source Breakdown Voltage ID=250µA, VGS=0V 20 V
VDS=16V, VGS=0V 1
IDSS Zero Gate Voltage Drain Current µA
TJ=55°C 5
IGSS Gate-Body leakage current VDS=0V, VGS=±10V 10 µA
BVGSO Gate-Source Breakdown Voltage VDS=0V, IG=±250uA ±12 V
VGS(th) Gate Threshold Voltage VDS=VGS ID=250µA 0.5 0.71 1 V
ID(ON) On state drain current VGS=4.5V, VDS=5V 30 A
VGS=10V, ID=7.5A 13 16
mΩ
TJ=125°C 18 22
VGS=4.5V, ID=7A 15 18 mΩ
RDS(ON) Static Drain-Source On-Resistance
VGS=3.6V, ID=6A 16.8 20 mΩ
VGS=2.5V, ID=6A 19 24 mΩ
VGS=1.8V, ID=5A 26 34 mΩ
gFS Forward Transconductance VDS=5V, ID=7.5A 30 S
VSD Diode Forward Voltage IS=1A,VGS=0V 0.74 1 V
IS Maximum Body-Diode Continuous Current 2.5 A
DYNAMIC PARAMETERS
Ciss Input Capacitance 1390 pF
Coss Output Capacitance VGS=0V, VDS=10V, f=1MHz 190 pF
Crss Reverse Transfer Capacitance 150 pF
Rg Gate resistance VGS=0V, VDS=0V, f=1MHz 1.5 Ω
SWITCHING PARAMETERS
Qg Total Gate Charge 15.4 nC
Qgs Gate Source Charge VGS=4.5V, VDS=10V, ID=7.5A 1.4 nC
Qgd Gate Drain Charge 4 nC
tD(on) Turn-On DelayTime 6.2 ns
tr Turn-On Rise Time VGS=5V, VDS=10V, RL=1.3Ω, 11 ns
tD(off) Turn-Off DelayTime RGEN=3Ω 40.5 ns
tf Turn-Off Fall Time 10 ns
trr Body Diode Reverse Recovery Time IF=7.5A, dI/dt=100A/µs 15 ns
Qrr Body Diode Reverse Recovery Charge IF=7.5A, dI/dt=100A/µs 5.1 nC

A: The value of R θJA is measured with the device mounted on 1in2 FR-4 board with 2oz. Copper, in a still air environment with TA =25°C. The
value in any given application depends on the user's specific board design. The current rating is based on the t ≤ 10s thermal resistance
rating.
B: Repetitive rating, pulse width limited by junction temperature.
C. The R θJA is the sum of the thermal impedence from junction to lead RθJL and lead to ambient.
D. The static characteristics in Figures 1 to 6,12,14 are obtained using <300 µs pulses, duty cycle 0.5% max.
E. These tests are performed with the device mounted on 1 in2 FR-4 board with 2oz. Copper, in a still air environment with TA=25°C. The SOA
curve provides a single pulse rating.
Rev 3: July 2006

THIS PRODUCT HAS BEEN DESIGNED AND QUALIFIED FOR THE CONSUMER MARKET. APPLICATIONS OR USES AS CRITICAL
COMPONENTS IN LIFE SUPPORT DEVICES OR SYSTEMS ARE NOT AUTHORIZED. AOS DOES NOT ASSUME ANY LIABILITY ARISING
OUT OF SUCH APPLICATIONS OR USES OF ITS PRODUCTS. AOS RESERVES THE RIGHT TO IMPROVE PRODUCT DESIGN,
FUNCTIONS AND RELIABILITY WITHOUT NOTICE.

Alpha & Omega Semiconductor, Ltd.


AO8814

TYPICAL ELECTRICAL AND THERMAL CHARACTERISTICS

30 20
10V 3V VDS=5V
4V
VGS =2V 15
20
ID(A)

ID(A)
10

10
125°C
5
VGS =1.5V
25°C

0 0
0 1 2 3 4 5 0.0 0.5 1.0 1.5 2.0 2.5
VDS(Volts) VGS(Volts)
Figure 1: On-Regions Characteristics Figure 2: Transfer Characteristics

50 1.6
VGS =1.8V VGS=2.5V
Normalize ON-Resistance
40 ID=6A
VGS=4.5V
1.4
VGS =3.6V ID=7A
RDS(ON)(mΩ)

30 VGS=1.8V
VGS =2.5V ID=5A
1.2
20 VGS=10V
ID=7.5A
10 1.0
VGS =4.5V VGS =10V

0 0.8
0 5 10 15 20 0 25 50 75 100 125 150 175
ID(A) Temperature (°C)
Figure 3: On-Resistance vs. Drain Current and Figure 4: On-Resistance vs. Junction
Gate Voltage Temperature

60 1E+01
ID=7.5A
1E+00
50

1E-01 125°C
RDS(ON)(mΩ)

40
IS(A)

1E-02
125°C
30
1E-03

20 1E-04 25°C
25°C

10 1E-05
0 2 4 6 8 0.0 0.2 0.4 0.6 0.8 1.0

VGS(Volts) VSD(Volts)
Figure 5: On-Resistance vs. Gate-Source Voltage Figure 6: Body-Diode Characteristics

Alpha & Omega Semiconductor, Ltd.


AO8814

TYPICAL ELECTRICAL AND THERMAL CHARACTERISTICS

5 2000
VDS=10V
ID=7.5A 1600 Ciss
4

Capacitance (pF)
1200
VGS(Volts)

2 800

Crss
1 400 Coss

0 0
0 5 10 15 20 0 5 10 15 20

Qg (nC) VDS(Volts)
Figure 7: Gate-Charge Characteristics Figure 8: Capacitance Characteristics

100.0
TJ(Max)=150°C 40
TA=25°C TJ(Max)=150°C
RDS(ON) 10µs TA=25°C
30
10.0 limited 100µs
Power (W)
ID (Amps)

1ms
20
0.1s 10ms
1.0
1s 10
10s
DC
0.1 0
0.1 1 10 100 0.001 0.01 0.1 1 10 100 1000
VDS (Volts) Pulse Width (s)
Figure 9: Maximum Forward Biased Safe Figure 10: Single Pulse Power Rating Junction-to-
Operating Area (Note E) Ambient (Note E)

10
D=Ton/T In descending order
ZθJA Normalized Transient

TJ,PK=TA+PDM.ZθJA.RθJA D=0.5, 0.3, 0.1, 0.05, 0.02, 0.01, single pulse


Thermal Resistance

RθJA=83°C/W
1

PD
0.1
Ton
T

0.01
0.00001 0.0001 0.001 0.01 0.1 1 10 100 1000
Pulse Width (s)
Figure 11: Normalized Maximum Transient Thermal Impedance

Alpha & Omega Semiconductor, Ltd.


P/N: 4-BI010L
JOULES MILES CO., LTD.
Rev. D

SPECIFICATION APPROVAL SHEET Page 74

5. Dimension
P/N: 4-BI010L
JOULES MILES CO., LTD.
Rev. D

SPECIFICATION APPROVAL SHEET Page 76

6. Label Information