0326-03-35-12 Datasheet File Sika Anchorfix-1
0326-03-35-12 Datasheet File Sika Anchorfix-1
0326-03-35-12 Datasheet File Sika Anchorfix-1
Edition 1, 2009
Identification no.
02 04 02 06 001 0 000019
Version no. 0010
Sika Anchorfix® -1
®
Sika Anchorfix -1
Fast Curing Anchoring Adhesive
Description Solvent- and styrene free based two-part polyester anchoring adhesive.
■ Threaded rods
■ Bolts and special fastening systems
■ Concrete
■ Hollow and solid masonry
®
Prior to any application, the suitability of the Sika AnchorFix Adhesive for the
substrate in terms of the desired bond strength, and for the prevention of surface
staining or discolouration, must be confirmed by testing in a sample area. This is
due to the wide variation of possible substrates, particularly in terms of strength,
composition and porosity:
■ Hard natural stone
■ Solid rock
Product Data
Form
Colours Part A: white
Part B: black
Part A+B mixed: light grey
Storage
Storage Conditions / 12 months from date of production if stored properly in original unopened, sealed
Shelf life and undamaged packaging in cool and dry conditions at temperatures between
0°C and +20°C. Protect from direct sunlight.
®
All Sika AnchorFix -1 cartridges have the expiry date printed on the label.
Back
Table of Contents
The indicated filling quantities are calculated without wastage. Wastage 10 - 50%.
The filled quantity can be monitored during injection with the help of the
scale on the catridge label.
Substrate Quality Mortar and concrete must be at the required strength. No need to be 28 days old.
Substrate strength (concrete, masonry, natural stone) must be verified.
Pull-out tests must be carried out if the substrate strength is unknown.
The anchor hole must always be clean, dry, free from oil and grease etc..
The anchor hole must always be dry, free from oil and grease etc.
Loose particles must be removed from the holes.
Threaded rods and rebars have to be cleaned thoroughly from any oil, grease or
any other substances and particles such as dirt etc.
Application
Conditions /
Limitations
Substrate Temperature -10°C min. / +40°C max.
®
Sika AnchorFix -1 must be at a temperature of +5°C and +40°C for a pplication.
Unscrew Cut the film Screw on Place the cartridge into the
and remove the static gun and start application
the cap mixer
When the work is interrupted the static mixer can remain on the cartridge after
the gun pressure has been relieved. If the resin has hardened in the nozzle when
work is resumed, a new nozzle must be attached.
Pump approx. twice until both parts come out uniformly. Do not
use this material. Release the gun pressure and clean the
cartridge opening with a cloth.
Inject the adhesive into the hole, starting from the bottom, while
slowly drawing back the static mixer. In any case avoid
entrapping air. For deep holes extension tubing can be used.
Insert the anchor with a rotary motion into the filled drill hole.
Some adhesive must come out of the hole.
During the resin hardening time the anchor must not be moved
®
or loaded. Wash tools immediately with Sika Colma Cleaner.
Wash hands and skin thoroughly with warm soap water.
To fix anchors into hollow materials (bricks or blocks) perforated sleeves must be
used.
Note: with hollow material do not use rotary hammer drills.
Value Base All technical data stated in this Product Data Sheet are based on laboratory tests.
Actual measured data may vary due to circumstances beyond our control.
Local Restrictions Please note that as a result of specific local regulations the performance of this
product may vary from country to country. Please consult the local Product Data
Sheet for the exact description of the application fields.
Health and Safety For information and advice on the safe handling, storage and disposal of chemical
Information products, users shall refer to the most recent Material Safety Data Sheet
containing physical, ecological, toxicological and other safety-related data.
Legal Notes The information, and, in particular, the recommendations relating to the application and end-use of Sika
products, are given in good faith based on Sika’s current knowledge and experience of the product when
properly stored, handled and applied under normal conditions in accordances with Sika’s
recommendations. In practice, the differences in materials, substrates and actual site conditions are such
that no warranty in respect of merchantability or of fitness for a particular purpose, nor any liability arising
Construction
out of any legal relationship whatsoever, can be inferred either from this information, or from any written
recommendations, or from any other advice offered. The user of the product must test the product’s
suitability for the intended application and purpose. Sika reserves the right to change the properties of its
products. The proprietary rights of third parties must be observed. All orders are accepted subject to our
current terms of sale and delivery. Users must always refer to the most recent issue of the local Product
Data Sheet for the product concerned, copies of which will be supplied on request.