AnchorFix-S 20081118 en Rev 00
AnchorFix-S 20081118 en Rev 00
AnchorFix-S 20081118 en Rev 00
Edition 18/11/2008
Revision: 00
Identification no:
01 04 02 06 001 0 000031
Sika AnchorFix®-S
Sika AnchorFix®-S
Universal anchoring adhesive
Construction
Prior to any application, the suitability of the Sika AnchorFix® Adhesive for the
substrate in terms of the desired bond strength, and for the prevention of surface
staining or discolouration, must be confirmed by testing in a sample area. This is
due to the wide variation of possible substrates, particularly in terms of strength,
composition and porosity:
n Hard natural stone
n Solid rock
Characteristics / n Fast curing
Advantages n Non-sag, even overhead
n Low wastage
Product Data
Form
Colours Part A: white
Part B: black
Part A+B mixed: light grey
Packaging 380 ml standard cartridge, 12 per box.
Pallet: 60 boxes with 12 cartridges, 720 pieces.
Storage
Storage Conditions / 12 months form date of production if stored properly in original unopened, sealed
Shelf-Life and undamaged packaging in cool and dry conditions at temperatures between
0°C and +20°C. Protect from direct sunlight.
All Sika AnchorFix®-S cartridges have the expiry date printed on the label.
Sika AnchorFix®-S
1 1/6
Technical Data
Density 1.7 kg/l (part A+B mixed).
Curing Speed
Temperature Open Time Tgel Curing Time Tcur
0°C 50 minutes 300 minutes
Mechanical / Physical
Properties
Compressive Strength ~ 74 N/mm2 (According to ASTM D695)
Design Terminology and Abbreviations:
Important Note:
The load capacity of the threaded rod by itself must be verified.
The anchor hole must be dry.
Sika AnchorFix®-S
2 2/6
Load Capacity Data for Reinforcing Bar Anchors:
Requirements for the calculation of the characteristic load capacity:
Reinforcing bar S500 ribbed
(the load capacity of the reinforcing bar itself must also be verified)
Min. concrete C20 / 25
The anchor hole must be dry
Bar diameter
6 8 10 12 14 16 20 25
d (mm)
Hole diameter
8 10 12 14 18 20 25 32
dO (mm)
Minimum anchorembedment
60 80 90 100 115 130 140 150
hmin (mm)
hef - 50
Equation for tensile load capacity: NRK =
2,5
c
s Rf cN = 0.4 + 0.4 × c
Rf s = 0.4 + 0.6 × Rf cV = 0.25 + 0.5 ×
h ef
h ef h ef
Important Note:
The load capacity of the thread rod itself must also be verified.
The anchor hole must be dry.
Resistance
Thermal Resistance Temperature resistance of the cured adhesive:
+50°C long term, +80°C short term (1 - 2 hours)
System
Information
Application Details
Consumption / Dosage Material consumption per anchor in ml
Anchor Drill
Drill hole depth in mm
Ø Ø
mm mm 80 90 110 120 130 140 160 170 180 200 210 220 240 260 280 300 350 400
8 10 3 4 4 5 5 5 6 6 7 7 7 8 8 9 9 10 11 12
10 12 4 5 5 6 6 6 7 8 8 8 8 9 10 10 11 12 14 15
12 14 5 6 6 6 7 7 8 8 9 10 10 11 11 12 13 14 16 18
14 18 9 10 11 14 14 15 18 19 20 22 23 24 26 28 30 32 37 42
16 18 9 10 11 13 14 15 17 18 19 21 22 23 26 28 30 32 36 40
20 10 12 12 15 16 17 20 21 22 24 25 26 29 31 33 35 40 46
20 24 12 13 14 15 16 18 22 24 26 28 30 32 36 38 42 48 58 66
25 18 19 21 23 24 26 30 31 32 36 38 40 44 46 50 54 64 72
24 26 24 25 28 30 33 35 40 43 45 50 55 58 60 65 70 75 100 125
The indicated filling quantities are calculated without wastage. Wastage 10 - 50%.
The filled quantity can be monitored during injection with the help of the scale
on the catridge label.
Sika AnchorFix®-S
3 3/6
Substrate Quality Mortar and concrete must be at the required strength. No need to be 28 days old.
Substrate strength (concrete, masonry, natural stone) must be verified.
Pull-out tests must be carried out if the substrate strength is unknown.
The anchor hole must always be clean, dry, free from oil and grease etc.
Loose particles must be removed from the holes.
Application
Conditions /
Limitations
Substrate Temperature 0°C min. / +40°C max.
Sika AnchorFix®-S must be at a temperature of +5°C to +40°C for application.
Ambient Temperature 0°C min. / +40°C max.
Sika AnchorFix®-S must be at a temperature of +5°C to +40°C for application.
Application
Instructions
Mixing Part A : part B = 10 : 1 by volume
Mixing Tools Getting the cartridge ready:
When the work is interrupted the static mixer can remain on the cartridge after the
gun pressure has been relieved. If the resin has hardened in the nozzle when work
is resumed, a new nozzle must be attached.
Sika AnchorFix®-S
4 4/6
Application Method / General Remarks:
Tools
Drilling of hole with an electric drill to the diameter and depth
required. Drill hole diameter must be in accordance with anchor
size.
The drill hole must be cleaned after each cleaning step with a
blow pump or by compressed air, starting from the bottom of the
hole.
Important: use oil-free compressors!
Pump approx. twice until both parts come out uniformly. Do not
use this material. Release the gun pressure and clean the
cartridge opening with a cloth.
Inject the adhesive into the hole, starting from the bottom, while
slowly drawing back the static mixer. In any case avoid entrapping
air. For deep holes extension tubing can be used.
Insert the anchor with a rotary motion into the filled drill hole.
Some adhesive must come out of the hole.
Important: the anchor must be placed within the open time.
During the resin hardening time the anchor must not be moved or
loaded. Wash tools immediately with Sika® Colma Cleaner.
Wash hands and skin thoroughly with warm soap water.
To fix anchors into hollow materials (bricks or blocks) perforated sleeves must be
used.
Note: with hollow material do not use rotary hammer drills.
Cleaning of Tools Clean and tools and application equipment with Sika® Colma Cleaner immediately
after use. Hardened / cured material can only be mechanically removed.
Sika AnchorFix®-S
5 5/6
Value Base All technical data stated in this Product Data Sheet are based on laboratory tests.
Actual measured data may vary due to circumstances beyond our control.
Local Restrictions Please note that as a result of specific local regulations the performance of this
product may vary from country to country. Please consult the local Product Data
Sheet for the exact description of the application fields.
Health and Safety For information and advice on the safe handling, storage and disposal of chemical
products, users shall refer to the most recent Material Safety Data Sheet containing
Information physical, ecological, toxicological and other safety-related data.
Legal Notes The information, and, in particular, the recommendations relating to the application
and end-use of Sika products, are given in good faith based on Sika's current
knowledge and experience of the products when properly stored, handled and
applied under normal conditions in accordance with Sika’s recommendations. In
practice, the differences in materials, substrates and actual site conditions are such
Construction
Sika AnchorFix®-S
6 6/6