Electrical
Electrical
Electrical
An instrument for measuring the rate of flow of electricity, usually expressed in amperes
Ammeter
Blackout Switch On a theatre stage, a master switch that distinguishes all stage lights simultaneously.
The portion of an electric wiring that extends beyond the final over current device protecting
Feeder Line the circuit
An underground structure used in pulling or splicing electric cables which are laid
Cable Vault underground.
Direct Current In an electric circuit, a current that flows in one direction only
In electric wiring a metal plate, water pipe, or other type of conductor buried in the earth in
Grounding Wire manner ensuring a good conductive path to the ground.
Electric current A movement or flow of electrically charged particles, typically measured in amperes.
diffuser What is a surface, material, device, or object that scatters light or sound from a source?
flux What is an electromagnetic force flowing between the positive and negative terminals?
2/32
PREPARED BY:
ALEXANDER SAN ANDRES
ELECTRICAL REVIEWER
This shows the vertical relationships of all panels, feeders,
switches, switchboards, and major components are shown up
Riser Diagram
to, but not including, branch circuiting, it is an electrical
version of a vertical section taken through the building.
In a lightning protection system, the combination of a
Air Terminal metal rod and its brace or footing, on the upper part of a
structure.
Moisture resistant, in
TW in electrical wire specification means.
wet and dry location
Moisture and Heat
Resistant- Cross-Linked XHHN in wire specification means.
Thermosetting
the reciprocal of ohm Mho as used in electrical systems calculation is defined as _______.
A unit of mechanical power is horsepower. What is electrical
Watt
power?
Who said these prophetic words: “Let the future tell the truth
and evaluate each one according to his work and accomplishment.
Nikola Tesla
The present is theirs, the future for which I really worked for is
mine.”?
Rigid metal conduit A type of raceway specially constructed for the purpose of pulling
(RMC) in or the withdrawing of wires or cables after the conduit is in place.
Heat resistant The trade name for an insulated conductor with type letter THHN
thermoplastic is ______.
What is / are the advantage/s of a circuit breaker over a fuse?
a. It can act as a switch
All of these b. Its position can be easily detected (close/open)
c. It can be used again after fault has been corrected
d. All of these
What switch combination may be used in order to control a lamp
2-s3w and 1-s4w
or group of lamps in three different locations?
Low resistance, high
It characterizes short circuit
current
A unit or assembly units or sections and associated fittings
Cable tray
forming a rigid structural system used to support cables.
Fusible material in a fuse may be made of any of the following
Silver
except___.
It affects the resistance of a conductor.
a. Length
All of the above
b. Area
c. Temperature
Panelboard It is also known as electric panel or load center.
A cylindrical conduit or conductor, the wall thickness is sufficient
Conduit
to receive a standard pipe.
A factory assembly of one or more conductors, each individually
metal clad cable (type
insulated and enclosed in a metallic sheath of interlocking metal
MC)
tape, or a smooth corrugated metallic tube.
Current It is analogous to pressure in water flow.
Alternating current is characterized as having _____.
a. Positive and negative polarity
All of these
b. Average value is zero c. Has frequency
d. All of these
A circuit type where components are electrically connected end
Series circuit
to end.
a. Fungus resistant The over-all covering of underground feeder and branch circuit
b. Corrosion resistant cables shall be ____.
3/32
PREPARED BY:
ALEXANDER SAN ANDRES
ELECTRICAL REVIEWER
Switch The basic elements of an electric circuit are the following except
Non metallic sheathed A factory assembly of two or more insulated conductors having an
cable (type NM and outer sheath of moisture-resistant, flame retardant, non metallic
NMC) material.
Cables are conductors that are ____.
Both a and b a. Larger than wires
b. Stranded (no.6 AWG and larger)
Which of the following metallic materials is considered as the
Gold
best conductor of electricity?
Example/s of conductors-on-insulator wiring is are ______.
Both a and b a. Concealed knob and tube
b. Open wiring on insulators
A type of surface flush raceway designed to receive conductors
Multi-outlet assembly
and receptacles assembled in the field or in the factory.
A type of switch used for transferring one or more load conductor
Transfer switch
connections from one power source to another.
The part of the cut out that is design to open or break an electrical current under an
CIRCUIT BREAKER
excessive load
WATTS Unit of power
AMPERE The unit used in the measure of the rate of flow of electricity
A type of electric switch consisting of one or more movable copper blades which are hinged
KNIFE SWITCH
and which make contact with stationary forked contract jaws being forced between them
TRANSFORMER VAULT Provision for building with an expected electric load demand of 200KVA
JUNCTION BOX An iron box or casing by which electrical conduit branches are formed
5 STOREYS A passenger elevator with a constant 24 hour service for residential condominum
3.00 m Minimum service drop of connection line above the ground and from the ground
500 mm Minimum distance of poles and transformer support located from the road right of way
AIR CURTAIN A vertical flow of air used to separate different function of spaces
DISTRIBUTION LINE The main feed line of an electrical circuit to which branch circuits are connected
PLUG IN TYPE Another type of circuit breaker element other than bolt-on
4/32
PREPARED BY:
ALEXANDER SAN ANDRES
ELECTRICAL REVIEWER
TRANSFORMER A device used to convert voltage from higher to lower or vise versa
NON FERROUS METAL Metal containing no iron such as copper, brass and aluminum
The minimum allowance clearance from the highest point of the roof to the service drop
2.50m
conductor from NBC
STEP DOWN
To bring down voltage
TRANSFORMER
AUTOMATIC TRANSFER Transferring the power load from the building circuitry to standby generator or during
SWITCH brownout
Cable provided in wrapping of metal usually steel wires or tapes, primarily for the purpose of
ARMORED CABLE
mechanical protection
That portion of a wiring system extending beyond the final overcurrent device protecting
BRANCH CIRCUIT
the current
Is a conductor, or group of conductors, in switchgear assemblies which serves as a common
BUS
connection for two or more circuit
Approved assembly of insulated conductors with fitting and conductor terminations in a
BUSWAY
completely enclosed, ventilated protective metal housing where the system is design to carry
System of conductor forming an essentially continuous conducting network over the
CAGE
object protected and including any conductors necessary for interconnections of the object
A device design to open under abnormal conditions a current carrying circuit without injury
CIRCUIT BREAKER
itself
A wire or combination of wires not insulated from one another suitable for carrying electric
CONDUCTOR
current
A device or group of devices which serves to govern in some predetermined manner, the
CONTROLLER
electric power delivered to the apparatus to which it is connected
A luminous discharge due to ionization of the air surrounding a conductor caused by voltage
CORONA
gradient exceeding a certain critical value
CUT OUT BOX A metal housing that houses the circuit breaker or fuses; surface mounted
Is the ratio of the maximum demand of the system or part of the system to the total
DEMAND FACTOR
connected load of the system
DEVICE A unit of electrical system which is intended to carry but not utilize electrical energy
ELECTRIC MOTOR Machine which transforms electric power into mechanical power
5/32
PREPARED BY:
ALEXANDER SAN ANDRES
ELECTRICAL REVIEWER
The circuit conductors between the service equipment or the generator switchboard of an
FEEDERS
isolated plant and the branch circuit overcurrent device
Unit of illumination when the foot is taken as the unit of length. It is the illumination on a
FOOTCANDLE
surface one square foot in area in which there is uniformly distributed flux of one lumen
An overcurrent protective device with a circuit opening fusible member which is heated and
FUSE
severed by the passage of the overcurrent through it
GENERAL LIGHTING Types of lighting that deals with lighting relatively large area covered
Is a form of air switch in which the moving element is a hinge blade wedge between
KNIFE SWITCH
stationary contact blades when closed
OUTLET Point of the wiring system at which current is taken to supply utilization equipment
OUTLET BOX A metal box at an outlet which encloses one or more receptacle
PENDENT Device or equipment which is supended from overhead either by means of the flexible cord
Auxillary conductor used in connection with remote measuring devices for operating
PILOT WIRE
apparatus at a distant point
Box with a blank cover which is inserted in one or more runs of raceway to facilitate pulling in
PULLBOX
the conductors and the distributing of the conductors
The overhead service conductor from the last pole or other aerial support to and including
SERVICE DROP
splices if any connecting to the service entrance conductors at the building
SERVICE RACEWAY The raceway that encloses the service entrance conductors
6/32
PREPARED BY:
ALEXANDER SAN ANDRES
ELECTRICAL REVIEWER
Minimum wire size of THW stranded copper conductor in raceway for a branch circuit in a 30
5.5 mm2
ampere rating
SINGLE PHASE TO
This connetions is used where the load is comparatively small and the length of the
SUPPLY 120 V LIGHTING
secondary circuit is short
LOAD
SINGLE PHASE TO
SUPPLY 120/240 3-WIRE This connections is used in most urban distribution circuits
LIGHTING AND POWER
SINGLE PHASE FOR The 120/240 volt winding is connected in series serving 240 volts on a two wire system, this
POWER connection is used for small industrial applications
TWO PHASE Consist merely of two single phase transformers operated 90deg out of phase, the common
CONNECTIONS wire must carry /2 times the load current
DELTA-DELTA FOR This is used to supply a single phase lighting load and three phase power load
POWER AND LIGHTING simultaneously
OPEN DELTA FOR This connection is used when single phase lighting load is large as compared with the
LIGHTING AND POWER power load
Often it is desirable to increase the voltage of a circuit form a 2400 to 4160 volts to
Y DELTA FOR POWER
increase its potential capacity
This connection is similar to the delta-delta bank with only the primary connection changed
Y DELTA FOR LIGHTING The primary neutral should not be grounded or tied into the system neutral, since a single
AND POWER phase ground fault may result in extensive blowing of fuses throughout the system This
connection requires special watt-hour metering
When operating Y delta and one service is disabled, service maybe maintained at reduced
OPEN Y DELTA
load
DELTA Y FOR LIGHTING The single phase lighting load is all on one phase resulting in unblanced primary currents in
AND POWER any one bank
Y-Y FOR LIGHTING ANDThe primary voltage was increased from 2400 to 4160 volts to increase the potential
POWER capacity of the system
When the ratio of transformation from the primary to secondary voltage is small, the
Y-Y AUTO TRANSFORMER
most economical way of stepping down the voltage
SCOTT CONNECTION
In some localities two phase power is required from three phase system
3PHASE TO 2PHASE
SCOTT CONNECTED If it should be necessary to supply three phase power from a two phase system, the special
2PHASE TO 3PHASE tap must be provided on the secondary side
T Thermoplastic
UF Underground Feeder
7/32
PREPARED BY:
ALEXANDER SAN ANDRES
ELECTRICAL REVIEWER
BX Armored Cable
PE POLYETHELENE
SA SILICON ASBESTOS
FIXED TEMPERATURE Use low melting point solders or metal the expand when exposed to heat to detect fire
INFRARED FLAME It responds to the high-frequency radiant energy from flames. Alarm is only triggered when
DETECTOR IR energy flickers at rate which is chracteristics of flame
Uses the interruption of small current flow between electrodes by smoke in ionized
IONIZATION SMOKE HEAT
sampling
A factory assemble cable of one or more conductors each individualy insulated and enclosed
METAL CLAD CABLE (MC) in a mettalic sheath of interlocking tape of smooth or corrugated tube. This type of cable is
especially used for service feeders, branch circuit and for indoor, outdoor work
Is a factory assembly of one or more conductors insulated with highly compressed refractory
MINERAL INSULATED
mineral insulation enclosed in a liquid and gas tight continous copper sheath. This type of
CABLE (MI)
cable is used in dry, wet or continously moist location as service feeders or branch circuit
Is a also a factory assembly of two or more insulated conductors having a moisture resistant,
NON METALLIC SHEATED
flame retardant and non metallic material outer sheath. This type is used specifically for one
CABLE (NM)
or two family dwellings not exceeding 3 storey building
This type of cable is factory assembly of two or more insulated conductors in an extruded
SHIELDED NON METALLIC
core of moisture resistant and flame retardant material covered within an overlapping spiral
SHEATED CABLE (SNM)
metal tape. This type is used in hazardous locations and in cable trays or in raceways
UNDERGROUND FEEDER
Is a moisture resistant cable used for underground connections including direct burial in
AND BRANCH CIRCUIT
the ground as feeder or branch circuit This is factory assembled two or more insulated
(UF) POWER AND
conductors with or without associated bare or covered or grounding under a mettalic sheath,
CONTROL TRAY CABLE
(TC) This is used for installation of cable trays, raceways, or it is supported by messenger wire
FLAT CABLE ASSEMBLY Is an assembly of parallel conductors formed integrally with insulating material web designed
(FC) especially for field installation in metal surface or raceways
8/32
PREPARED BY:
ALEXANDER SAN ANDRES
ELECTRICAL REVIEWER
Consist of three or more flat copper conductor placed edge to edge separated and
FLAT CONDUCTOR enclosed with an insulating assembly. This type of cable is used for general purposes such
CABLE (FCC) as: appliance branch circuit, and for individual branch circuits, especially in hard smooth
continous floor surfaces and the like
MEDIUM VOLTAGE CABLE Is a single or multi conductor solid dielectric insulated cable rated at 2,000 volts or higher.
(MV) This type is used for power system up to 35,000 volts
TELEPHONE TERMINAL Part of the facility which accept the house cable riser and house the terminal block at each
CABINET floor and at the highest or end of a feeder riser cable
Is the simplest type of building automation system, which intercoms, PABX, microwave links,
TELECOMMUNICATION
analog and digital telephone system, video conferencing, satellite links, structured cabling
SYSTEM
and similar devices
Factory assembled of two or more insulated conductors w/ or w/o associated bare cover
POWER AND CONTROL
ground conductor under a non metallic sheath approved forr installation in cable trays, in
TRAY CABLE TYPE
raceways or in supported by a messenger wire
Light source used in lighting fixtures best specified in areas such as those requiring high
METAL HALIDE
illumination levels for detailed work such as needle work
SCOTT CONNECTION 2 A transformer location required in some localities, where a three phase power is required
PHASE TO 3 PHASE from a two phase system
ILLUMINATED SWITCH Type of switch where pilot light inside a lit to guide the person inside
DRAWINGS Main power supply and wiring system for 110/220 volt line; which wiring diagram fits (drawing)
Required minimum vertical clearance of an overhead service drop measured from the ground
5.500 mm over residential and comercial properties and driveways not subjected to truck traffic and over
600 volts to ground
9/32
PREPARED BY:
ALEXANDER SAN ANDRES
ELECTRICAL REVIEWER
A raceway especially constructed for the purpose of physical protection of conductors, the
RIGID STEEL CONDUIT pulling in or the withdrawing of wires or cables after the conduit is in place and made of metal
pipe of standard width and thickness
120/240 VOLTS System of voltage used for computing branch circuits and feeder load
Natural energy source derived from force of wind acting on oblique blades that radiates froma
WINDMILL
shaft attached to a dynamo to produce electricity
A point in th electrical system where the electrical load of a given area is assumed to
PANEL BOARD
concentrate
Alternating current generated by the alternator where its wave rises to the peak, sinks to
SINGLE PHASE
zero, drops to the negative peak and rises again to zero a number of times each second
ALTERNATING CURRENT
depending on the frequency for which the machine is designed
Alternating current where the alternator comprises of windings mounted at right angles to
TWO PHASE
each other and provided with separate external connections current waves will be produced
ALTERNATING CURRENT
and each of which will be at its maximum when the other is zero
2.2, 30, 8, 14 Minimum conductor size for for overhead service drop for copper wire or cable
THW Moisture and Heat Resistant Thermoplastic used for dry and wet locations
Vertical vent pipes take in front of the last fixture and connects to its soil stack which acts as
CIRCUIT VENT
a vent
A device designed to open and close a circuit by non automatic means and to open the circuit
CIRCUIT BREAKER automatically on predetermined over current without damaged to itself when properly applied
within its rating
SERVICE RACEWAY The raceway that encloses the service entrance conductors
Y-Y FOR LIGHTING AND A transformer connection which is ideal in the event of change of primary voltage from 2400
POWER volts to 4160 volts to increase the potential capacity of the system
Maximum allowed ampere rating of one chord or plug utilization equipment connected in a 30
24 AMPERE
ampere branch circuit for lighting or utilization equipment
Minimum wire size in sq.mm type THW stranded copper conductor in raceway for a branch
5.5 sq.mm
circuit with 30 ampere rating
Minimum vertical clearance of an overhead service drop measured from the ground, at the
electrical service entrance or above areas or sidewalks accesible only to pedestrian lanes,
3500mm
measure from final grade line or other accesible surface only for service drop cabled together
with a grounded bare messenger wire and limited to 300 volts to ground
Minimum ampacity of feeder conductor with a load of more than two wire branch circuit
30 amperes
supplied by a 3-wire feeder but not exceed the computed branch circuit load
Minimum wire size in sq.mm type TW copper conductor in raceway for a branch circuit with
3.5 sq.m
20 ampere rating
10/32
PREPARED BY:
ALEXANDER SAN ANDRES
ELECTRICAL REVIEWER
MULTI WIRE BRANCH A branch circuit consisting of two or more grounded conductors having a potential difference
CIRCUIT between them, and a grounded conductor having equal potential difference between it
PRESSURIZED WATER
A type of water coolant operates at a pressure of about 150 atmospheres
REACTOR
DEVICE A unit of electrical system which is intended to carry but not utilize electrical energy
The overhead service conductor from the last pole or other aerial support to and including the
SERVICE DROP
splices, if any connecting to te service entrance conductors at the building
BOILING WATER A type of nuclear reactor where the water coolant is permitted to boil within the core by
REACTOR operating at somewhat low pressure
In a 240V, a three phase 3-wire service, branch cicuits are loaded and distributed to each of
BALANCE LOADING
the three phase with this objective to attain
Unit or assembly of unit sections and associated fittings forming a rigid structural system
CABLE TRAYS
used to support cables
A transformer connection where the secondary load is a combination of lighting and power.
OPEN DELTA FOR
This connection is used when the single phase lighting is large as compared with the power
LIGHTING AND POWER
load
DELTA Y FOR LIGHTING A useful transformer connection applied when single phase lighting load is all on one phase
AND POWER resulting into unbalanced primary
Type of flexible cable which is a fabricated assembly of insulated conductors which permit its
ARMOR CABLE TYPE ACL
use at exposed weather or excessive moisture
THREE PHASE A type of alternating current where the alternator comprises the three armature windings set
ALTERNATING CURRENT at 120 degrees to each other, current will be produced in the form of triple wave
30 amperes Minimum branch circuit rating for household ranges and cooking appliance
POROUS ABSORBENT Type of sound absorbent best for lower band frequencies
A type of alternating current generated by alternator, where its wave rises to its peak, sinks to
SINGLE PHASE
zero, drop to a negative peak and rises again to zero a number of times each seconds
ALTERNATING CURRENT
depending on the frequency of the machine is designed
11/32
PREPARED BY:
ALEXANDER SAN ANDRES
ELECTRICAL REVIEWER
3-WAY SWITCH AT
three points
MIDPOINT AND
DRAWINGS Main power supply and wiring system for 110/220 volt line; which wiring diagram fits (drawing)
Pre requisite in use of split A CLEARANCE OF NOT LESS THAN 76mm SHALL BE MAINTAINED BETWEEN
knob and tube wiring CONDUCTORS AND NOT LESS THAN 26mm
A branch circuit consisting of two or more grounded conductors having a potential
MULTI WIRE BRANCH
difference between them, and a grounded conductor having equal potential difference
CIRCUIT
between it
What is the maximum horizontal range between two or more air terminal for lightning arrest
6000mm to 7600mm
for an effective disaster prevention in building
Required minimum vertical clearance of an overhead service drop measured from the ground
5500 mm over residential and comercial properties and driveways not subjected to truck traffic and over
600 volts to ground
Minimum vertical clearance of an overhead service drop measured from the ground, at the
electrical service entrance or above areas or sidewalks accesible only to pedestrian lanes,
3500mm
measure from final grade line or other accesible surface only for service drop cabled together
with a grounded bare messenger wire and limited to 300 volts to ground
Maximum allowed ampere rating of one chord or plug utilization equipment connected in a
24 amperes
30 ampere branch circuit for lighting or utilization equipment
Minimum ampacity of feeder conductor with a load of more than two wire branch circuit
30 amperes
supplied by a 3-wire feeder but not exceed the computed branch circuit load
Minimum wire size in sq.mm type THW stranded copper conductor in raceway for a branch
5.5 sq.mm
circuit with 30 ampere rating
Minimum wire size in sq.mm type TW copper conductor in raceway for a branch circuit with20
3.5 sq.m
ampere rating
30 amperes Minimum branch circuit rating for household ranges and cooking appliance
A device that is basically a double throw switch of generally 3-pole connection that will
Automatic Transfer
automatically transfer the power from the standby generator to the building circuitry during
Switch (ATS)
electrical power failure.
Moisture resistant, in
TW in electrical wire specification means.
wet anddry location
A type of lighting that provides illumination to special objects like sculptures, flower
Specific Lighting
arrangements, etc.
12/32
PREPARED BY:
ALEXANDER SAN ANDRES
ELECTRICAL REVIEWER
Infra Red The other type of flame detector other than the ultraviolet type.
Phase Interrelationship between value of voltage and current with the same frequency.
Descriptive of any material such as synthetic resin which hardens when heated or cured, and
Thermosetting
does not soften when reheated.
5.5 sqmm Minimum wire size in square millimeter for a branch circuit with a 30 ampere rating using
60 Cycles Standard frequency of power supplied by the local power utility company like Meralco.
The overhead service conductors from the last pole or other aerial support to and including
Service Drop
splices, if any, connecting to the service entrance conductors at the building.
Telecommunication
The simplest type of building automation system.
System
Fixed Temperature A fire detector installed in a fire alarm system which uses low melting point solders or
Heat Detector metal that expands when exposed to heat to detect a fire.
PABX A private telephone system that interconnects with public telephone systems.
13/32
PREPARED BY:
ALEXANDER SAN ANDRES
ELECTRICAL REVIEWER
A rigid metal housing for a group of heavy conductors insulated from each other and the
Busway
enclosure, also called Busduct.
A heavy conductor, usually in the form of a solid copper bar, used for collecting, carrying, and
Bus
distributing large electric currents, also called a busbar.
Passive Infrared A type of perimeter detector which detects object in heat range of body temperature.
Light Beam A type of perimeter detector which detects interruption of light beam.
Ultrasonic A type of perimeter detector which detects change in sound wave pattern.
A box with a blank cover which serves the purpose of joining one different runs of raceways
Pull Box or cables and provided with sufficient space for connection and branching of the enclosed
conductors.
A type of perimeter detector which is subject to false alarm from aircraft radar and from
Microwave
movement outside building through window, wood doors, and the like. It uses radio waves.
Passive Infrared with This type of perimeter detector uses both the Passive infrared and Ultrasonic or
Ultrasonic (or
Microwave system.
Microwave)
This type of perimeter detector detects a change in capacitance of the area covered, caused
Proximity / Capacitance
by intrusion.
A high intensity discharge lamp in which the light is produced by the radiation from a mixture
Metal Halide Lamp
of a metallic vapor, similar to that of a mercury lamp in construction.
A type of lamp popular for lighting commercial interiors, uses argon gas to ease starting, it
Mercury Lamp
produces light by means of an electric discharge in mercury vapor.
Tungsten Halogen A type of lamp which produces light by means of the reaction of halogen additive in the bulb
Lamp reacts with chemically with tungsten.
High-Pressure-Sodium
A type of lamp generally used for roadways and sidewalks, uses sodium gas.
(HPS)
14/32
PREPARED BY:
ALEXANDER SAN ANDRES
ELECTRICAL REVIEWER
In a lightning protection system, the combination of a metal rod and its brace or footing, on
Air Terminal
the upper part of a structure.
15/32
PREPARED BY:
ALEXANDER SAN ANDRES
ELECTRICAL REVIEWER
16/32
PREPARED BY:
ALEXANDER SAN ANDRES
Ammeter
Amperage
Blackout Switch
Feeder Line
Cable Vault
Candlepower
Current
Direct Current
Grounding Wire
Footcandle
Electric current
appliances
alternator
ammeter
capacitor
diffuser
rectifier
illumeter –
greenfield
regulator
entrance cap
utility box
flux
voltage
phase
watt –
rheostat
regulator
ohmmeter
insulator
17/32
PREPARED BY:
ALEXANDER SAN ANDRES
coulomb
ohm
volts
candela
10 ft.
Pvt. Automatic Branch
Exchange
Capacitor
Power Panel
No. 12
No. 14
Rectifier
D.C. Generator
Phase
5.5 sqmm
60 Cycles
Service Drop
Telecommunication
System
Impedance
Resistance
Busway
Bus
Busway
Pull Box
18/32
PREPARED BY:
ALEXANDER SAN ANDRES
Riser Diagram
Air Terminal
Moisture resistant, in
wet and dry location
Moisture and Heat
Resistant- Cross-Linked
Thermosetting
the reciprocal of ohm
Watt
Nikola Tesla
All of these
Silver
Panelboard
Conduit
Current
All of these
Series circuit
a. Fungus resistant
b. Corrosion resistant
19/32
PREPARED BY:
ALEXANDER SAN ANDRES
Switch
Non metallic sheathed
cable (type NM and
NMC)
Both a and b
Gold
Both a and b
Multi-outlet assembly
Transfer switch
CIRCUIT BREAKER
WATTS
AMPERE
TOWER OR FLATFORM
KNIFE SWITCH
TRANSFORMER VAULT
RECTIFIER
RAPID START
FLOURESCENT LAMP
JUNCTION BOX
5 STOREYS
3.00 m
500 mm
AIR CURTAIN
GOOSENECK
DISTRIBUTION LINE
1.20m
PLUG IN TYPE
COPPER WIRE
RACEWAY
20/32
PREPARED BY:
ALEXANDER SAN ANDRES
CABLE WIRE
DISTRIBUTION PANEL
TRANSFORMER
2.50m
STEP DOWN
TRANSFORMER
OPEN WIRING
AUTOMATIC TRANSFER
SWITCH
AIR SWITCH
ARC VOLTAGE
ARMORED CABLE
ASKAREL
ASSEMBLY
BASE LOAD
BRANCH CIRCUIT
BUS
BUSWAY
CAGE
CIRCUIT BREAKER
CONDUCTOR
CONTROLLER
CORONA
DEMAND FACTOR
DEVICE
DUCT
ELECTRIC MOTOR
21/32
PREPARED BY:
ALEXANDER SAN ANDRES
FEEDERS
FOOTCANDLE
FUSE
GENERAL LIGHTING
ILLUMINATION
KNIFE SWITCH
LAMP
LAMPHOLDER
LIGHT
LIGHTNING ARRESTER
LIGHTNING SURGE
LINE TAP
LOAD FACTOR
LUMEN
LUX
OUTLET
OUTLET BOX
PEAK LOAD
PENDENT
PILOT WIRE
PULLBOX
RACEWAY
RECEPTACLE
ROSETTE
SERVICE DROP
SERVICE RACEWAY
SUBMARINE CABLE
22/32
PREPARED BY:
ALEXANDER SAN ANDRES
SURGE
5.5 mm2
SINGLE PHASE TO
SUPPLY 120 V LIGHTING
LOAD
SINGLE PHASE TO
SUPPLY 120/240 3-WIRE
LIGHTING AND POWER
SINGLE PHASE FOR
POWER
TWO PHASE
CONNECTIONS
DELTA-DELTA FOR
POWER AND LIGHTING
OPEN Y DELTA
SCOTT CONNECTION
3PHASE TO 2PHASE
SCOTT CONNECTED
2PHASE TO 3PHASE
TW
UF
FEPW
RH
RHW
RUH
THW
THWN
23/32
PREPARED BY:
ALEXANDER SAN ANDRES
XHHW
BX
THHN
PE
SA
AVA
FIXED TEMPERATURE
HEAT DETECTOR
PHOTO ELECTRIC
DETECTOR
INFRARED FLAME
DETECTOR
DETECTOR
MINERAL INSULATED
CABLE (MI)
UNDERGROUND FEEDER
AND BRANCH CIRCUIT
(UF) POWER AND
CONTROL TRAY CABLE
(TC)
24/32
PREPARED BY:
ALEXANDER SAN ANDRES
FLAT CONDUCTOR
CABLE (FCC)
TELEPHONE TERMINAL
CABINET
TELECOMMUNICATION
SYSTEM
RH
METAL HALIDE
SCOTT CONNECTION 2
PHASE TO 3 PHASE
TW
ILLUMINATED SWITCH
85 amperes
DRAWINGS
15 amperes
5.500 mm
25/32
PREPARED BY:
ALEXANDER SAN ANDRES
BUSWAYS
120/240 VOLTS
WINDMILL
PANEL BOARD
SINGLE PHASE
ALTERNATING CURRENT
TWO PHASE
ALTERNATING CURRENT
2.2, 30, 8, 14
UF
THW
CIRCUIT VENT
CIRCUIT BREAKER
SERVICE RACEWAY
24 AMPERE
5.5 sq.mm
3500mm
30 amperes
3.5 sq.m
26/32
PREPARED BY:
ALEXANDER SAN ANDRES
45 Amperes
PRESSURIZED WATER
REACTOR
DEVICE
BUSWAYS
60 CYCLES
USE
SERVICE DROP
BOILING WATER
REACTOR
BALANCE LOADING
CABLE TRAYS
THREE PHASE
ALTERNATING CURRENT
30 amperes
POROUS ABSORBENT
HERTZ
SINGLE PHASE
ALTERNATING CURRENT
27/32
PREPARED BY:
ALEXANDER SAN ANDRES
3-WAY SWITCH AT
MIDPOINT AND
DRAWINGS
6000mm to 7600mm
5500 mm
3500mm
24 amperes
30 amperes
85 amperes
45 amperes
15 amperes
5.5 sq.mm
3.5 sq.m
30 amperes
Automatic Transfer
Switch (ATS)
Moisture resistant, in
wet anddry location
Specific Lighting
28/32
PREPARED BY:
ALEXANDER SAN ANDRES
10'
Infra Red
Capacitor
Power Panel
No. 12
No. 14
Phase
Thermosetting
5.5 sqmm
5.5 sqmm
60 Cycles
Service Drop
Telecommunication
System
Fixed Temperature
Heat Detector
PABX
29/32
PREPARED BY:
ALEXANDER SAN ANDRES
Impedance
Resistance
Busway
Bus
Busway
Passive Infrared
Light Beam
Ultrasonic
Pull Box
Microwave
Ultrasonic (or
Microwave)
Proximity / Capacitance
Mercury Lamp
Tungsten Halogen
Lamp
High-Pressure-Sodium
(HPS)
Intelligent Building
30/32
PREPARED BY:
ALEXANDER SAN ANDRES
Air Terminal
31/32
PREPARED BY:
ALEXANDER SAN ANDRES