Data Sheet: BGY32 BGY33 BGY35 BGY36
Data Sheet: BGY32 BGY33 BGY35 BGY36
Data Sheet: BGY32 BGY33 BGY35 BGY36
DATA SHEET
Philips Semiconductors
Product specication
12 3 4
5 67
Top view
MSB029
ZS, ZL () 50 50 50 50
WARNING Product and environmental safety - toxic materials This product contains beryllium oxide. The product is entirely safe provided that the BeO disc is not damaged. All persons who handle, use or dispose of this product should be aware of its nature and of the necessary safety precautions. After use, dispose of as chemical or special waste according to the regulations applying at the location of the user. It must never be thrown out with the general or domestic waste.
1996 Jun 06
Philips Semiconductors
Product specication
LIMITING VALUES In accordance with the Absolute Maximum Rating System (IEC 134). SYMBOL VS1 VS2 Vi Vo PD DC supply voltage DC supply voltage RF input terminal voltage RF output terminal voltage input drive power BGY32; BGY33 BGY35; BGY36 PL Tstg Th load power storage temperature operating heatsink temperature 40 200 300 30 +100 90 mW mW W C C PARAMETER MIN. MAX. 15 15 25 25 V V V V UNIT
MGE659
handbook, halfpage
40
PL (W) 30
20
10
0 50
50
Th (C)
100
VSWR = 1.
1996 Jun 06
Philips Semiconductors
Product specication
CHARACTERISTICS ZS = ZL = 50 ; VS1 = VS2 = 12.5 V; Th = 25 C; unless otherwise specied. SYMBOL f PARAMETER frequency BGY32 BGY33 BGY35 BGY36 IQ1 IQ2 PL leakage current leakage current load power BGY32 BGY33 BGY35 BGY36 H2 H3 VSWRin efciency second harmonic third harmonic input VSWR stability with respect to 50 VS1 = 6 to 15 V; VS2 = 10 to 15 V; VS1 VS2; PD = 50 to 200 mW; VSWR 3 : 1 through all phases; PD = 100 mW PD = 100 mW PD = 150 mW PD = 150 mW 18 18 18 18 40 23 22 22 21 50 1.5 25 25 60 dBc W W W W % dBc dBc PD = 0 PD = 0 68 80 132 148 6 13 88 108 156 174 MHz MHz MHz MHz mA mA CONDITIONS MIN. TYP. MAX. UNIT
1996 Jun 06
Philips Semiconductors
Product specication
5 +VS1 3
+VS2
R.F. output
R.F. input
2 4
MGE658
Ruggedness The module will withstand a load mismatch VSWR of 50:1 (all phases) for short period overload conditions, with PD, VS1 and VS2 at maximum values providing the combination does not result in the matched RF output power rating being exceeded. MOUNTING To ensure good thermal transfer the module should be mounted on a heatsink with a flat surface with heat-conducting compound applied between module and heatsink. If an isolation washer is used, heatsink compound should be applied to both sides of the washer. Burrs and thickening of the holes in the heatsink should be removed and 3 mm bolts tightened to a maximum torque of 0.5 Nm. The leads of the devices may be soldered directly into a circuit using a soldering iron with a maximum temperature of 245 C for not more than 10 seconds at a distance of at least 1 mm from the plastic.
APPLICATION INFORMATION Supply An electrolytic capacitor of 10 F, 25 V, in parallel with a polyester capacitor of 100 nF to earth, is recommended as a decoupling arrangement for each power supply pin. Power rating In general it is recommended that the output power from the module under nominal conditions should not exceed 23 W in order to provide an adequate safety margin under fault conditions. Output power control The module is not designed to be operated over a large range of output power levels. The purpose of the output power control is to set the nominal output power level. The preferred method of output power control is by varying the drive power between 50 and 200 mW. The next option is by varying VS1 between 6 and 12.5 V.
1996 Jun 06
Philips Semiconductors
Product specication
52.5 50.0 44.9 17.0 14.4 9.3 6.8 7.65 max 12 34 5 67 19.7 4.2 3.7 0.25 8.1
3.3
61.0
0.2 M A
MBC876
Dimensions in mm.
Fig.4 SOT132B.
1996 Jun 06
Philips Semiconductors
Product specication
This data sheet contains target or goal specications for product development. This data sheet contains preliminary data; supplementary data may be published later. This data sheet contains nal product specications. The data in this specication is extracted from a full data sheet with the same type number and title. For detailed information see the relevant data sheet or data handbook.
Limiting values given are in accordance with the Absolute Maximum Rating System (IEC 134). Stress above one or more of the limiting values may cause permanent damage to the device. These are stress ratings only and operation of the device at these or at any other conditions above those given in the Characteristics sections of the specication is not implied. Exposure to limiting values for extended periods may affect device reliability. Application information Where application information is given, it is advisory and does not form part of the specication. LIFE SUPPORT APPLICATIONS These products are not designed for use in life support appliances, devices, or systems where malfunction of these products can reasonably be expected to result in personal injury. Philips customers using or selling these products for use in such applications do so at their own risk and agree to fully indemnify Philips for any damages resulting from such improper use or sale.