HYTORC NUT CT-Series Specification Guide-060220
HYTORC NUT CT-Series Specification Guide-060220
HYTORC NUT CT-Series Specification Guide-060220
Specification Guide
The HYTORC Nut
replaces fasteners,
minimizes stresses,
and covers a wide
range of sizes and
applications
1-800-FOR-HYTORC HYTORC.COM
CT-SERIES
PART NUMBER DESIGNATI0N
BLANK SIZE
C T X X-X X X X X X-X X X The Blank Size defines the HYTORC Nut body size — retrieve from Column 1 of the Dimensional
Table located on the facing page. This size is always a two-digit number.
STUD SIZE
IMPERIAL (in.) METRIC (mm)
STUD SIZE SIZE CODE STUD SIZE SIZE CODE
5/8 010 5 005
Height 1 100 10 010
2-1/2 208 100 100
4-1/4 404 150 150
THREAD PITCH
IMPERIAL (in.) METRIC (mm)
THREADS PER IN. PITCH CODE (TPI) MM PER THREAD PITCH CODE
4 04 1 01
4-1/2 45 3 03
8 08 3.5 35
12 12 6 06
TEMPERATURE LUBRICATION
For best performance, Standard Temperature Lubrication can have implications on load
should be specified unless the environment characteristics, temperature ratings and ease
Outside Diameter specifically requires otherwise. Temperature of removal. Please consult HYTORC lubrication
ratings may not apply to applications that data sheets to guide your selection process.
require CREEP resistance. Please inquire with Alternative lubricants are available upon
HYTORC Engineering for applications with request. The most common lubricants are:
long durations at temperatures greater than
800°F (426°C). R Molykote 1000 Paste
S Molykote P-37 Anti-Seize Paste (Standard)
T Molykote GN Metal Assembly Paste
W N-7000 Loctite Anti-Seize
1. Identify Blank Size 2. Outside Diameter 3. Verify that the Max 4. Verify that there is 5. Use the part number template from the adjacent
from table below. for this Blank Size Stroke is sufficient for sufficient overhead page to generate the part number.
(Cross reference this should not interfere your application. clearance for access
number from the with adjacent nuts with tooling.
row with the proper or other application
Nominal Stud Size). constraints (such as a
small spot face).
This is the basic body size for the HYTORC Nut. Any desired thread up This is the HYTORC code used to indicate the Nominal Stud Size.
to the Nominal Stud Size can be cut into each Blank Size. Cross- IMPERIAL: First digit signifies the whole number of inches. Add two
reference this number from the row with the proper Nominal Stud digits to signify the number of 1/16 of an inch — (108 = 1” + 8/16” = 1-1/2”).
Size. Verify that the Outside Diameter for this Blank Size will not METRIC: The three digits signify the whole number in millimeters —
interfere with adjacent nuts or other application constraints (such as a (024 = M24, 110 = M110).
small spot face).
This is the largest stud that will fit a particular Blank Size. All HYTORC This is the overall height of the standard HYTORC Nut for this Blank
Nut blanks can be specified with threads smaller than the Nominal Size. Tooling will require additional overhead space. This is not the
Stud Size. Height of the stud protrusion. Consult with a HYTORC Applications
Engineer when custom height HYTORC Nuts are required.
MA X STROKE
Verify that the Max Stroke is sufficient for the application. HYTORC Nuts have maximum stroke lengths that are limited by the height of the
splined washer. More stroke may be needed to accommodate gasket compression or an extraordinarily long joint length. Consult with a HYTORC
Applications Engineer for special extended stroke HYTORC Nuts.
The World’s Most Trusted Industrial Bolting Systems For Over Fifty Years
ADDITIONAL FACTS
AND INFORMATION
SAMPLE LOAD CHART MATERIALS
LOAD CHARTS
SPECIALS
Measurement of the thread pitch is the most error prone portion of HYTORC Nut specification. Please contact HYTORC to request available
The easiest way to measure pitch is with a pitch gauge. Alternatively, please provide HYTORC drives and to specify non-standard HYTORC Nuts.
with a sample of the stud. Special coatings can cause dimensional variations on studs and nuts,
i.e. Galvanized studs often have a coating build up that effectively changes the thread size. If the
application studs have coatings, special care should be taken to determine the actual thread size.
A standard HYTORC Nut will not fit a standard UN stud thread if a thick coating is applied. In these
situations it will typically be best to supply HYTORC with a sample stud.
NOTICE OF PROPRIETARY RIGHTS: HYTORC Division UNEX Corporation (“HYTORC”) is the owner of all content included in this document and all right, title and interest to such content shall
remain with HYTORC. COPYRIGHT NOTICE: © 2020 HYTORC. Any unauthorized use or distribution of any material from this document, without HYTORC’s written permission, is strictly prohibited.
TRADEMARK NOTICE: This document contains numerous registered trademarks and servicemarks of HYTORC in the U.S. and other countries. PATENT NOTICE: Products in this document are
covered by numerous registered and/or pending patents in the U.S. and other countries.
Headquarters: Email:
333 Route 17 N., Mahwah, NJ 07430 info@hytorc.com
+1-201-512-9500
Phone: Online:
CCAT-CTSERIES-BKLT-20200602 1-800-FOR-HYTORC hytorc.com