Product Manual EIE – RCPT APPARATUS

www.eieinstruments.com, www.eiepharmatest.com, www.eieceratest.com, www.eiepetrotest.com


Organization’s ISO 9001:2015 Certificate

PRODUCT USER MANUAL : EIE_ RCPT_PUM_00 Revision No.: EIE/RCPT/REV.00 Dtd. 15/08/2020
INSTRUMENT: RCPT TEST APPARATUS Page No.: 2 of 18
Forward

Dear valued customer,

We just want to take a moment out to thank you for your keen interest in our company
products. We greatly appreciate your business and the opportunity you provided us to assist
you. You have joined a selected group of customers who have switched to the technologically
superior and quality enhanced laboratory testing product.

Time has changed, so do the technology. Your purchase lists you on the cutting edge of 21st
century technology. The attached test report is an excellent way of expressing and maintaining
your trust in EIE’s - superior quality testing products. Our continued efforts and commitment is
to provide you efficient sales after services, prompt attention and highest level of customer
satisfaction. If for any reasons, you have questions or comments, we are delighted to hear from
you. Call us on 0091-79-660406013 or send us email at
info@eieinstruments.com/kunal@eieinstruments.com. You can expect us to respond to your
email within 24-48 working hours.

Once again, thank you for your trust and kind patronage. We look forward to serve you better
in future.

Yours sincerely,
EIE Instruments

PRODUCT USER MANUAL : EIE_ RCPT_PUM_00 Revision No.: EIE/RCPT/REV.00 Dtd. 15/08/2020
INSTRUMENT: RCPT TEST APPARATUS Page No.: 3 of 18
Table of contents

Organization’s ISO 9001:2015 Certificate ............................................................................... 2


Forward ................................................................................................................................ 3
Table of contents................................................................................................................... 4
List of Figures ........................................................................................................................ 5
1 Introduction of RCPT ...................................................................................................... 6
2 Principle ........................................................................................................................ 6
3 Packaging slip ................................................................................................................ 6
4 Chemicals and apparatus required in RCPT test .............................................................. 6
5 Installation of RCPT ........................................................................................................ 7
6 Specification for Rapid Chloride Permeability Tester....................................................... 8
6.1 Specification of RCPT Apparatus............................................................................... 8
6.2 Specification of RCPT diffusion cell ........................................................................... 8
7 Preparation of chemical solutions .................................................................................. 9
7.1 Preparation of NACL ................................................................................................ 9
7.2 Preparation of NAOH ............................................................................................... 9
7.3 Preparation of concrete sample (specimen) ............................................................. 9
7.4 Assembling of diffuser cell ..................................................................................... 10
8 Operation instruction for RCPT (HMI) ........................................................................... 11
9 Procedure to perform the test ...................................................................................... 15
10 Calculation ................................................................................................................... 15
11 Precautions to followed ............................................................................................... 16
Warranty certificate ............................................................................................................ 17

PRODUCT USER MANUAL : EIE_ RCPT_PUM_00 Revision No.: EIE/RCPT/REV.00 Dtd. 15/08/2020
INSTRUMENT: RCPT TEST APPARATUS Page No.: 4 of 18
List of Figures
Figure 1 Component Diagram of Diffuser Cell ....................................................................... 10
Figure 2 Connector for main power Supply ........................................................................... 11
Figure 3 Main switch To Turn ON/OFF the Apparatus ........................................................... 11
Figure 4 Welcome screen ..................................................................................................... 11
Figure 5 Test Selection Screen .............................................................................................. 12
Figure 6 Enter Required Data to perform test ....................................................................... 12
Figure 7 Reading While Test is Under process ....................................................................... 13
Figure 8 Final Result Screen ................................................................................................. 14
Figure 9 Final test result screen ............................................................................................ 14

PRODUCT USER MANUAL : EIE_ RCPT_PUM_00 Revision No.: EIE/RCPT/REV.00 Dtd. 15/08/2020
INSTRUMENT: RCPT TEST APPARATUS Page No.: 5 of 18
1 Introduction of RCPT
RCPT is commonly referred as Rapid Chloride Permeability Tester. Rapid Chloride Permeability Test can
be used for a wide range of application and quality control purpose. RCPT has multiport testing facilities
is especially designed to test concrete samples (specimens) for concrete ion permeability test for civil
engineering department and various research centers. RCPT is also known as Coulomb test.

2 Principle
The Rapid Chloride- ion Permeability test (RCPT) is conducted to know to assess the resistance of concrete
to the penetration of chloride ions, an indicator of its permeability. A customer can test up to four samples
at a time (as per ASTM C – 1202 standard) electrical indication of concrete ability to resist chloride ion
penetration. The sample (specimen) must be 100 mm diameter with 50 mm thickness. It is also available
in eight cell.

3 Packaging slip
1) Plexi glass chambers with conductive brass mesh, terminals and steel bolts – 10 pairs
2) DC constant Voltage power supply (220 V) cum DAQ unit with 8 channels – 1 No.
3) 300 mm Vacuum desiccator – 1 No.
4) Vacuum pump – 1 No.
5) Elastomeric Rubber Mould for cylindrical specimens – 10 Nos.
6) Thermocouple – 10 Nos.
7) RTV Sealant + gun – 1 No.
8) Mould for specimen – 10 Nos.
9) NACL, NAOH – 2 each.

4 Chemicals and apparatus required in RCPT test


 Sodium chloride (NACL)
 Sodium Hydroxide (NAOH)
 Vacuum pump
 Vacuum desiccator
 Wash bottle 2 piece (1000ml)
 Concrete specimen

PRODUCT USER MANUAL : EIE_ RCPT_PUM_00 Revision No.: EIE/RCPT/REV.00 Dtd. 15/08/2020
INSTRUMENT: RCPT TEST APPARATUS Page No.: 6 of 18
5 Installation of RCPT

1. Inspect equipment and shipping crate immediately upon receipt. If any damage is apparent,
immediately discuss it with the delivery person and contact the transportation company immediately.
Make notes of any damages on the bill of landing.
2. Retain all shipping material for later inspection.
3. Check packing slip carefully and ensure all materials have been received as indicated in packing slip.
4. Instrument is supplied in enclosed wooden case. Unpack the wooden case, locate and count the
number of accessories and main working unit. Remove packing strip from surroundings of the
instrument and all its accessories. Please inspect and note whether any part of the instrument is
damaged or any accessory is missing according to packing slip? If it is so, then immediately make note
of it and report to the manufacturer.
5. Due to the vibration incurred during shipping and handling, it is possible that mechanical connection
could become loose. Inspect all connection to ensure that they are secure.
6. After visual inspection, if everything is found to be okay, transit the instrument to suitable safe place
where it is intended to install. Caution: Handle with care.
7. Recycle the packing material and wooden box. Do not throw it away for environment protection.
8. Place the unit on a plain, even and sturdy surface leaving 12-18” space away from the wall.
9. Do not install unit in a corrosive environment. A corrosive environment may lead to poor
performance and deterioration of unit.
10. Do not place the equipment in a draft, sunlight or near a place of equipment, which emits heat as
well as electromagnetic conduction emission.
11. Keep Standard Operating Procedure and Respective Standard ready to conduct the test.

PRODUCT USER MANUAL : EIE_ RCPT_PUM_00 Revision No.: EIE/RCPT/REV.00 Dtd. 15/08/2020
INSTRUMENT: RCPT TEST APPARATUS Page No.: 7 of 18
6 Specification for Rapid Chloride Permeability Tester

6.1 Specification of RCPT Apparatus


 Power of 55 – 65 Volts DC is supplied by each cell.
 EIE – RCPT apparatus is accommodated with HMI LCD display fully touch screen to control and operate
the tests procedure.
 Apparatus is furnished with Eight cells to perform 8 different tests in same period of time
 D – link wireless router is fitted in apparatus to connect it directly to PC, to visualize the test procedure
easily.
 RTD connector code is provided in every cell to read the exact temperature and also for safety purpose
of diffuser cell, as high temperature may damage the cell.
 Each cell is fitted with Fuse of 1 ampere to protect the cells from short circuit and high voltage supply.
 Salazer switch is provided to turn ON/OFF the apparatus.

6.2 Specification of RCPT diffusion cell


 Each & every RCPT diffuser cells are made up of transparent acrylic material of 150 mm150 mm50
mm thick as per described in ASTM C - 1202.
 Concrete specimen (sample) of 100mm diameter and 50mm thick is fitted in acrylic material.
 It is provided with rubber gasket and washers to achieve leak proof.
 Stainless steel bolts with washers and nuts are provided to hold the specimen rigidly.
 The power supply will be applied to each cell through banana sockets and the current is distributed
through the brass mesh.
 Each cell will be provided with openings in top for pouring chemicals and the temperature sensors.
The openings can be closed with lids.
 The volume of chemicals within the chamber must be 250ml.

PRODUCT USER MANUAL : EIE_ RCPT_PUM_00 Revision No.: EIE/RCPT/REV.00 Dtd. 15/08/2020
INSTRUMENT: RCPT TEST APPARATUS Page No.: 8 of 18
7 Preparation of chemical solutions
The solution of NACL and NAOH is prepared to perform the test to check chloride permeability of concrete.
Diffuser cell consists of two chambers, first chamber is filled with sodium chloride solution (NACL) and
another chamber is filled with sodium hydroxide solution in fixed amount (250 ml). Prescribed amount
and preparation of solution is detailed below:

7.1 Preparation of NACL


Use 3% of NACL (sodium chloride) powder i.e. 30 grams of NACL in 1 liter of distilled water. Stir the
solution properly so that NACL is completely dissolved in water. Now NACL solution is ready to pore in
the diffuser cell.

7.2 Preparation of NAOH


Use 0.3 mole of sodium hydroxide (NAOH) i.e. 0.3  40 grams (NAOH) = 12 grams (NAOH) user have to
dissolve in 1 liter of distilled water. Stir the solution properly so that salt is completely dissolved in water.
Now pore the solution in another chamber of diffuser cell.

7.3 Preparation of concrete sample (specimen)

Prepare concrete specimen using the mould of size 100 mm diameter  50 mm thickness. Fix the
desiccators and vacuum pump nearby to connect them properly through rubber tube. Keep the stand
which holds the water tank near the desiccators. The desiccator’s lid is fitted with knob, two valve
openings. One of the valve openings is connected to the vacuum pump and another one to water tank
through rubber tubes.
Now turn ON the vacuum pump and let the pressure decrease to less than 50 mm Hg (use manometer to
check vacuum pressure). Maintain vacuum for 3 hours. After 3 hour open the water valve and let the
specimen completely immersed in water (with vacuum still running), then close the water valve and let
vacuum running for an additional hour. After an hour turn off vacuum pump and allow air to re- enter in
the desiccator.
Then soak the specimen under water for 18 ± 2 hours. Now the specimen is ready for test fit it tightly in
diffuser cell.

PRODUCT USER MANUAL : EIE_ RCPT_PUM_00 Revision No.: EIE/RCPT/REV.00 Dtd. 15/08/2020
INSTRUMENT: RCPT TEST APPARATUS Page No.: 9 of 18
7.4 Assembling of diffuser cell
The diffuser cell is provided with power connecting terminal, the terminal is connected to brass mesh for
distributing the current uniformly throughout the area of cross section. To seat the concrete module
properly a groove is provided in the acrylic diffuser cell. The groove is provided with brass washer and the
neoprene rubber washer to arrest the leakage of chemical solutions. Four corners of the cell s are provided
with fixed holes. The concrete specimen is placed between the two cells and tightened using stainless
steel bolts and nuts. Apply Silicone grease over joints between the cell and the concrete. There may be
small gaps, fill the gaps with silicone grease on both the ends. Apply the silicone grease over the surface
of the concrete specimen to arrest the leakage of chlorides through the surface of the concrete specimen.
Allow some time for drying the silicone grease. After solidification, Cell1 (fitted with black terminal) is
filled with sodium chloride solution of 3 M strength and is to be connected to the negative supply of the
RCPT apparatus. Cell 2 (fitted with red terminal) is filled with sodium hydroxide solution of 0.3M strength
is connected to the positive supply of the apparatus. Each cell will hold approximately 250 ml of solution.
If there is gap in the edges, silicon compound can be applied over the edges and the surface of the
concrete specimen to arrest the leakage if any. Now diffuser cell is ready for conducting the test for
chloride permeability.

Figure 1 Component Diagram of Diffuser Cell

PRODUCT USER MANUAL : EIE_ RCPT_PUM_00 Revision No.: EIE/RCPT/REV.00 Dtd. 15/08/2020
INSTRUMENT: RCPT TEST APPARATUS Page No.: 10 of 18
8 Operation instruction for RCPT (HMI)
 Connect the three pin adapter to the connector provided on the unit, then plug the cord in the main
power supply.

Figure 2 Connector for main power Supply


 Whenever you have to perform any test, Turn ON the Salzar Switch (Mains Switch ON)

Figure 3 Main switch To Turn ON/OFF the Apparatus

 As the mains switch is turned on, welcome window will open as shown in below figure:

Figure 4 Welcome screen

 Press on “ENTER” button on HMI to proceed further for test.

PRODUCT USER MANUAL : EIE_ RCPT_PUM_00 Revision No.: EIE/RCPT/REV.00 Dtd. 15/08/2020
INSTRUMENT: RCPT TEST APPARATUS Page No.: 11 of 18
 After that test select Mode will appear, user have to select the RCPT test and proceed further.
NOTE: Never go in calibration mode and do not try to change the factory set calibration

Figure 5 Test Selection Screen


 After selecting RCPT test, New window of Main Screen is displayed on HMI screen.

Figure 6 Enter Required Data to perform test

PRODUCT USER MANUAL : EIE_ RCPT_PUM_00 Revision No.: EIE/RCPT/REV.00 Dtd. 15/08/2020
INSTRUMENT: RCPT TEST APPARATUS Page No.: 12 of 18
 Logging Period is the total test time for the sample being tested, it is user defined user can increase/
decrease the time as per requirement. According to ASTM D – 1202 it is 360 minutes.
NOTE: Always enter the test time in minutes only
 Logging interval is the record time for the test readings of different intervals, it must also be entered
in minutes.
 Remaining test time will be displayed accordingly.
 After entering all the above needs you can select “START” to start the test.
 If user wants to stop the test in any case, click on “STOP” to hold the test.

Figure 7 Reading While Test is Under process

 Press “NEXT” button on HMI to monitor the readings of current supply (in ampere), Temperature rise
of each cell due to the electric current pass and also actual voltage being supplied by the apparatus.
 User can transfer the reading to their PC, using “EXPORT TO PC” option being displayed on the HMI
display.

PRODUCT USER MANUAL : EIE_ RCPT_PUM_00 Revision No.: EIE/RCPT/REV.00 Dtd. 15/08/2020
INSTRUMENT: RCPT TEST APPARATUS Page No.: 13 of 18
 By selecting monitoring on right hand side of HMI display user can check each interval reading also.

Figure 8 Final Result Screen

 After test is performed user can take the readings recorded of every 30minutes interval and final
reading of 360 minutes.
 Coulombs are also calculated for each cell in the final reading.
 Final result window will open after completion of test period.

Figure 9 Final test result screen

 After completion of test, if user have to perform new test, press “RESET” button on HMI, to start new
test.

PRODUCT USER MANUAL : EIE_ RCPT_PUM_00 Revision No.: EIE/RCPT/REV.00 Dtd. 15/08/2020
INSTRUMENT: RCPT TEST APPARATUS Page No.: 14 of 18
9 Procedure to perform the test
1) Prepare the test sample of concrete of dimension 100 mm diameter  50 mm thickness (As
mentioned in ASTM standard)
2) Remove the specimen from desiccator and fix it tightly in the diffuser cell.
3) Now, pour NACL solution in one chamber and NAOH solution in another chamber of diffuser cell.
4) Then carefully connect all the terminals to diffuser cell according to the sign indicated on it, also RTD
cable to visualize the temperature increase.
5) Again check all the connection carefully before starting the test.
6) Set the parameters in HMI displays as explained above in section.
7) Now by clicking on “START” start the test.
8) After completion of test take the reading and turn off the apparatus.
NOTE: While test is under process keep checking the temperature if it rises above the decided limit please
stop the test otherwise diffuser cell may be affected.
 Users are advised to operate the unit through UPS as whole tests get terminated if power supply
gets off while performing the test, and you have to start the test from step 1. Hence always use the
apparatus through UPS only.

10 Calculation
User can set the record time “30 minutes” and also the Logging time as 6 hours (360 minutes). HMI will
take the readings of corresponding cells at every record time with its initial readings automatically. At the
end of Log time, the system will stop after taking the final reading. User can take the reading as per
recorded on the system.

Average current flowing through one cell is calculated by,

Q = 900(I0 + 2 I30 + 2 I60 + 2 I90 + 2 I120 + 2 I150 + 2 I180 + 2 I210 + 2 I240 + 2 I270 + 2 I300+
2 I330 + I360)
Where,
Q = Charge passed (Coulombs)
I0 = Initial current reading in mA.
I30 = Current reading at 30 minutes in mA.

PRODUCT USER MANUAL : EIE_ RCPT_PUM_00 Revision No.: EIE/RCPT/REV.00 Dtd. 15/08/2020
INSTRUMENT: RCPT TEST APPARATUS Page No.: 15 of 18
I60 = Current reading at 60 minutes in mA.
I90 = Current reading at 90 minutes in mA.
I120 = Current reading at 120 minutes in mA.
I150 = Current reading at 150 minutes in mA.
I180 = Current reading at 180 minutes in mA.
I210 = Current reading at 210 minutes in mA.
I240 = Current reading at 240 minutes in mA.
I270 = Current reading at 270 minutes in mA.
I300 = Current reading at 300 minutes in mA.
I330 = Current reading at 330 minutes in mA.
I360 = Current reading at 360 minutes in mA.

11 Precautions to followed
1) While cleaning take care that the small/ sensitive parts which do not get damaged.
2) Keep the instrument tidy, clean and dry with mint cream. Before initiating the fresh day, use
preferably clean soft cloth. Brush up the unit body to maintain its finishing and shine.
3) Keep checking the RTD temperature if cross the limit (above 100C) immediately terminate the test
and turn off the apparatus.
4) Place the unit in plane and even surface only otherwise inaccuracy may occur.
5) Fix the sample properly and tightly in the diffuser cell.
6) Cross check the output voltage using voltmeter for accurate result.
7) After completion of test disconnect all the connections carefully.
8) Always connect positive terminal to positive terminal in diffuser cell and negative terminal to negative
terminal of diffuser cell only.
9) Disassembly of this equipment is strictly limited to the qualified persons and licensed engineers only.
10) In case of any difficulty, please do not try to repair without consulting us, especially when the
instrument is under warranty period.

PRODUCT USER MANUAL : EIE_ RCPT_PUM_00 Revision No.: EIE/RCPT/REV.00 Dtd. 15/08/2020
INSTRUMENT: RCPT TEST APPARATUS Page No.: 16 of 18
Warranty certificate

Your EIE product is guaranteed to be free from defects in materials and workmanship for one (1) year
under normal use from the date of purchase. This WARRANTY does not apply to any product damaged by
accident, misuse, mishandling, abuse, negligence, transit, improper line voltage, drop, fire, flood or if the
products were altered or repaired by anyone other than the qualified service personnel. The liability of
EIE Instruments is limited to repair or replacement and under no circumstances shall EIE be liable for any
collateral consequential damages or loss. This guarantee specifically excludes the expendables and
consumables.
All warranty claims must be directed to your corresponding purchase
organization that is responsible for the sale of this equipment. The users are responsible for shipping
expense. The warranty cards which are not signed and stamped by the actual user will be treated as void.
The warranty card should accompany the defective products sent for repair, without which no claims
would be entertained. Please detach the below warranty card from following cut-line.

………………………………………………………………………………………………………………………………………

Name of the company:

Address:

Telephone no:

Mobile no:

Email address:

Date of purchase:

Product model:

Serial no:

Bill or cash memo no:

This card should be detached, filled in properly and posted within 15 days from the date of purchase
otherwise the warranty becomes invalid.

PRODUCT USER MANUAL : EIE_ RCPT_PUM_00 Revision No.: EIE/RCPT/REV.00 Dtd. 15/08/2020
INSTRUMENT: RCPT TEST APPARATUS Page No.: 17 of 18
--- End of Document ---

Any Note or Queries

Please write us
Thank you
We are in….

 Soil Testing Equipment.


 Bitumen Testing Equipment.
 Cement Testing Equipment.
 Aggregate Testing Equipment.
 Tiles, Geotextile testing Equipment.
 Pharmaceuticals Lab Testing Equipment.
 NABL Calibration & Many More…

www.eieinstruments.com | www.eieceratest.com
www.eiepharmatest.com | www.eiepetrostest.com

PRODUCT USER MANUAL : EIE_ RCPT_PUM_00 Revision No.: EIE/RCPT/REV.00 Dtd. 15/08/2020
INSTRUMENT: RCPT TEST APPARATUS Page No.: 18 of 18