Output Ratings
Voltage, Frequency Prime Standby
Fuel System
Fuel Filter Type: Replaceable Element
Recommended Fuel: Class A2 Diesel
Fuel Consumption at 110 % Load 100 % Load 75 % Load 50 % Load
50 Hz Prime: l/hr (US gal/hr) 25.5 (6.7) 23.8 (6.3) 18.9 (5) 12.9 (3.4)
50 Hz Standby l/hr (US gal/hr) - 25.5 (6.7) 20.4 (5.4) 14.2 (3.8)
60 Hz Prime l/hr (US gal/hr)
60 Hz Standby l/hr (US gal/hr) -
(Based on diesel fuel with a specific gravity of 0.83 and conforming to BS2869 classA2,EN590
Air System 50 Hz 60 Hz
Air Filter Type: Paper Element
Combustion Air Flow Prime m³/min (cfm) 6.4 (227)
Combustion Air Flow Standby m³/min (cfm) 6.7 (238)
Max. Combustion Air Intake Restriction kPa 5 (20.1)
Cooling System 50 Hz 60 Hz
Cooling System Capacity l (US gal) 17 (4.5)
Water Pump Type: Centrifugal
Heat Rejected to Water & Lube Oil: Prime kW (Btu/min) 47.1 (2679)
Heat Rejected to Water & Lube Oil: Standby kW (Btu/min) 51.9 (2952)
Heat Radiation to Room*: Prime kW (Btu/min) 20.5 (1166)
Heat Radiation to Room*: Standby kW (Btu/min) 22.5 (1280)
Radiator Fan Load: kW (hp) 2.8 (3.8)
Radiator Cooling Airflow: m³/min (cfm) 201 (7098)
External Restriction to Cooling Airflow: Pa (in H2O) 125 (0.5)
*: Heat radiated from engine and alternator
Designed to operate in ambient conditions up to 50°C (122°F).
Contact your local FG Wilson Dealer for power ratings at specific site conditions.
Lubrication System
Oil Filter Type: Spin-on, Full flow
Total Oil Capacity: l (US gal) 8.4 (2.2)
Oil Pan Capacity: l (US gal) 6.9 (1.8)
Oil Type: API CH4 15W-40
Oil Cooling Method: WATER
Exhaust System 50 Hz 60 Hz
Maximum Allowable Back Pressure: kPa (in Hg) 15 (4.4)
Exhaust Gas Flow: Prime m³/min (cfm) 16.4 (580)
Exhaust Gas Flow: Standby m³/min (cfm) 17.4 (614)
Exhaust Gas Temperature: Prime °C (°F) 657 (1215)
Exhaust Gas Temperature: Standby °C (°F) 675 (1247)
P110-6
Voltage Code
Output Ratings 50 Hz
Prime Standby
230/115V
220/127V
220/110V
200/115V
240V
230V
220V
Output Ratings 60 Hz
Prime Standby
480/277V
440/254V
416/240V
400/230V
380/220V
240/139V
240/120V
230/115V
220/127V
220/110V
208/120V
240/120
220/110
#DEALER_LOGO
#FGWILSON_GENSET_IMAGE
P110-6
Documentation
Operation and maintenance manual including circuit wiring diagrams.
Warranty
The warranty for this product in prime applications is 12 months from date of start-up, unlimited hours (8760).
For standby applications the warranty period is 24 months from date of start-up, limited to 500 hours per year.