Modbus Manual
Modbus Manual
Thank you for purchasing Modbus Card. This manual contains instructions and warnings that
should be followed during the installation, operating and storage of the card. Please keep this
manual for further reference.
Special Precautions
If the card must be stored prior to installation; storage must be in a dry place
The admissible storage temperature range is from -10ºC to +70ºC.
1. Product Overview
RS-485 port
Golden finger
Address switch
Communication setting
Resistance switch
2. Product Introduction
The Modbus card provides UPS and PV inverter systems with the functionality of communication
Provides MODBUS functions including read Holding Registers and write Registers.
Provides RS485 interface
Provides surge protection
1
Modbus Card Quick Guide V.2.5
4. Configuration
4.1 Machine ID Configuration
There are eight bits to present ID of each card.
Use SW1 to set machine ID. From left to right, it’s
8 to 1. As shown, when the switch is pushed
down, the bit is set to “one”. Otherwise, the bit is
set as zero. The ID of modbus card is set to 0x01
as chart. Please check appendix for detailed ID no.
and SW1 setting.
2
Modbus Card Quick Guide V.2.5
4.5 Connection
First, please use one RS485 to RS 232 converter or RS-485 to Modbus/TCP converter as media
converter between Modbus card and computer. Please follow below chart for wiring connection
between RJ45 and media converter:
3
Modbus Card Quick Guide V.2.5
5. Multiple Monitoring
One modbus card only can be used in one UPS at the same time. When each UPS installed with
one modbus card, up to 31 UPSs can be monitored from one computer.
4
Modbus Card Quick Guide V.2.5
40 × × × √ × √ × ×
41 √ × × √ × √ × ×
42 × √ × √ × √ × ×
43 √ √ × √ × √ × ×
44 × × √ √ × √ × ×
45 √ × √ √ × √ × ×
46 × √ √ √ × √ × ×
47 √ √ √ √ × √ × ×
48 × × × × √ √ × ×
49 √ × × × √ √ × ×
50 × √ × × √ √ × ×
51 √ √ × × √ √ × ×
52 × × √ × √ √ × ×
53 √ × √ × √ √ × ×
54 × √ √ × √ √ × ×
55 √ √ √ × √ √ × ×
56 × × × √ √ √ × ×
57 √ × × √ √ √ × ×
58 × √ × √ √ √ × ×
59 √ √ × √ √ √ × ×
60 × × √ √ √ √ × ×
61 √ × √ √ √ √ × ×
62 × √ √ √ √ √ × ×
63 √ √ √ √ √ √ × ×
64 × × × × × × √ ×
65 √ × × × × × √ ×
66 × √ × × × × √ ×
67 √ √ × × × × √ ×
68 × × √ × × × √ ×
69 √ × √ × × × √ ×
70 × √ √ × × × √ ×
71 √ √ √ × × × √ ×
72 × × × √ × × √ ×
73 √ × × √ × × √ ×
74 × √ × √ × × √ ×
75 √ √ × √ × × √ ×
76 × × √ √ × × √ ×
77 √ × √ √ × × √ ×
78 × √ √ √ × × √ ×
79 √ √ √ √ × × √ ×
80 × × × × √ × √ ×
81 √ × × × √ × √ ×
6
Modbus Card Quick Guide V.2.5
82 × √ × × √ × √ ×
83 √ √ × × √ × √ ×
84 × × √ × √ × √ ×
85 √ × √ × √ × √ ×
86 × √ √ × √ × √ ×
87 √ √ √ × √ × √ ×
88 × × × √ √ × √ ×
89 √ × × √ √ × √ ×
90 × √ × √ √ × √ ×
91 √ √ × √ √ × √ ×
92 × × √ √ √ × √ ×
93 √ × √ √ √ × √ ×
94 × √ √ √ √ × √ ×
95 √ √ √ √ √ × √ ×
96 × × × × × √ √ ×
97 √ × × × × √ √ ×
98 × √ × × × √ √ ×
99 √ √ × × × √ √ ×
100 × × √ × × √ √ ×
101 √ × √ × × √ √ ×
102 × √ √ × × √ √ ×
103 √ √ √ × × √ √ ×
104 × × × √ × √ √ ×
105 √ × × √ × √ √ ×
106 × √ × √ × √ √ ×
107 √ √ × √ × √ √ ×
108 × × √ √ × √ √ ×
109 √ × √ √ × √ √ ×
110 × √ √ √ × √ √ ×
111 √ √ √ √ × √ √ ×
112 × × × × √ √ √ ×
113 √ × × × √ √ √ ×
114 × √ × × √ √ √ ×
115 √ √ × × √ √ √ ×
116 × × √ × √ √ √ ×
117 √ × √ × √ √ √ ×
118 × √ √ × √ √ √ ×
119 √ √ √ × √ √ √ ×
120 × × × √ √ √ √ ×
121 √ × × √ √ √ √ ×
122 × √ × √ √ √ √ ×
123 √ √ × √ √ √ √ ×
7
Modbus Card Quick Guide V.2.5
124 × × √ √ √ √ √ ×
125 √ × √ √ √ √ √ ×
126 × √ √ √ √ √ √ ×
127 √ √ √ √ √ √ √ ×
128 × × × × × × × √
129 √ × × × × × × √
130 × √ × × × × × √
131 √ √ × × × × × √
132 × × √ × × × × √
133 √ × √ × × × × √
134 × √ √ × × × × √
135 √ √ √ × × × × √
136 × × × √ × × × √
137 √ × × √ × × × √
138 × √ × √ × × × √
139 √ √ × √ × × × √
140 × × √ √ × × × √
141 √ × √ √ × × × √
142 × √ √ √ × × × √
143 √ √ √ √ × × × √
144 × × × × √ × × √
145 √ × × × √ × × √
146 × √ × × √ × × √
147 √ √ × × √ × × √
148 × × √ × √ × × √
149 √ × √ × √ × × √
150 × √ √ × √ × × √
151 √ √ √ × √ × × √
152 × × × √ √ × × √
153 √ × × √ √ × × √
154 × √ × √ √ × × √
155 √ √ × √ √ × × √
156 × × √ √ √ × × √
157 √ × √ √ √ × × √
158 × √ √ √ √ × × √
159 √ √ √ √ √ × × √
160 × × × × × √ × √
161 √ × × × × √ × √
162 × √ × × × √ × √
163 √ √ × × × √ × √
164 × × √ × × √ × √
165 √ × √ × × √ × √
8
Modbus Card Quick Guide V.2.5
166 × √ √ × × √ × √
167 √ √ √ × × √ × √
168 × × × √ × √ × √
169 √ × × √ × √ × √
170 × √ × √ × √ × √
171 √ √ × √ × √ × √
172 × × √ √ × √ × √
173 √ × √ √ × √ × √
174 × √ √ √ × √ × √
175 √ √ √ √ × √ × √
176 × × × × √ √ × √
177 √ × × × √ √ × √
178 × √ × × √ √ × √
179 √ √ × × √ √ × √
180 × × √ × √ √ × √
181 √ × √ × √ √ × √
182 × √ √ × √ √ × √
183 √ √ √ × √ √ × √
184 × × × √ √ √ × √
185 √ × × √ √ √ × √
186 × √ × √ √ √ × √
187 √ √ × √ √ √ × √
188 × × √ √ √ √ × √
189 √ × √ √ √ √ × √
190 × √ √ √ √ √ × √
191 √ √ √ √ √ √ × √
192 × × × × × × √ √
193 √ × × × × × √ √
194 × √ × × × × √ √
195 √ √ × × × × √ √
196 × × √ × × × √ √
197 √ × √ × × × √ √
198 × √ √ × × × √ √
199 √ √ √ × × × √ √
200 × × × √ × × √ √
201 √ × × √ × × √ √
202 × √ × √ × × √ √
203 √ √ × √ × × √ √
204 × × √ √ × × √ √
205 √ × √ √ × × √ √
206 × √ √ √ × × √ √
207 √ √ √ √ × × √ √
9
Modbus Card Quick Guide V.2.5
208 × × × × √ × √ √
209 √ × × × √ × √ √
210 × √ × × √ × √ √
211 √ √ × × √ × √ √
212 × × √ × √ × √ √
213 √ × √ × √ × √ √
214 × √ √ × √ × √ √
215 √ √ √ × √ × √ √
216 × × × √ √ × √ √
217 √ × × √ √ × √ √
218 × √ × √ √ × √ √
219 √ √ × √ √ × √ √
220 × × √ √ √ × √ √
221 √ × √ √ √ × √ √
222 × √ √ √ √ × √ √
223 √ √ √ √ √ × √ √
224 × × × × × √ √ √
225 √ × × × × √ √ √
226 × √ × × × √ √ √
227 √ √ × × × √ √ √
228 × × √ × × √ √ √
229 √ × √ × × √ √ √
230 × √ √ × × √ √ √
231 √ √ √ × × √ √ √
232 × × × √ × √ √ √
233 √ × × √ × √ √ √
234 × √ × √ × √ √ √
235 √ √ × √ × √ √ √
236 × × √ √ × √ √ √
237 √ × √ √ × √ √ √
238 × √ √ √ × √ √ √
239 √ √ √ √ × √ √ √
240 × × × × √ √ √ √
241 √ × × × √ √ √ √
242 × √ × × √ √ √ √
243 √ √ × × √ √ √ √
244 × × √ × √ √ √ √
245 √ × √ × √ √ √ √
246 × √ √ × √ √ √ √
247 √ √ √ × √ √ √ √
10