Ifr6015 Military Flight Line Test Set Brochures en
Ifr6015 Military Flight Line Test Set Brochures en
Ifr6015 Military Flight Line Test Set Brochures en
VIAVI
IFR6015
Military Flight Line Test Set
Features
The VIAVI IFR6015 is a user friendly flight line test set y IFF Modes 1 & 2
that allows for fast, reliable, and functional testing y TACAN/DME interrogator testing
of military transponder, TCAS and TACAN installed y Military E-TCAS
systems. Referenced in many OEM manuals and y Transponder Auto Test (DO-181E)
supported with procedures, the IFR6015 provides the y Automated ADS-B AC 20-165B surface/air
operator with the confidence necessary for system performance testing
performance testing. y ADS-B (Out) monitor and decode
y ADS-B (In) target generation
y UUT parametric tests
y User programmable TCAS scenarios
y Altitude encoder
y Over-the-air, direct, or coupled testing
y Battery operation six hours plus
Benefits
y TACAN ground station simulation
y Legacy TACAN test set emulation
y Provides a full FAR Part 43, Appendix F test
y Verify ADS-B /UAT installed systems
y With the optional antenna coupler, avoid
ATC interference and the need for frequency
allocation approval (DD 1494)
y Performs TACAN/DME testing Ground-to-Air
(G/A), Air-to-Air (A/A)
y Simulate ATCRBS or Mode S intruders for TCAS
testing
Ordering Information Physical Characteristics
Size 11.2”H x 9.1”W x 2.7”D
Versions and Options
Test set only 28.4 cm x 23.1 cm x 6.8 cm
Order Number Description
w/ standard access. 24”H x 21”W x 12”D
72424 IFR6015 Mode 1,2,3A/C/S Transponder, TACAN/ 61 cm x 53.3 cm x 30.4 cm
DME, TCAS I/II, E-TCAS, TIS Ramp Test Set
Weight 8 lbs., 3.6 kg (test set only)
NSN: 6625-01-574-2423 34 lbs., 15.4 kg (shipping weight)
NSN: 6625-01-601-4034*
*Most current NSN, identified on unit serial tag Environmental
141590 IFR6015 Test Set w/ 6000OPT3 and 6000OPT6 options Altitude: < 4800 meters
83411 6000OPT3 ADS-B 1090 MHz Operating Temp. -20˚ to 55˚C (-4˚ to 131˚F)
112795** 6000OPT5 UAT 978 MHz (for units with Mod 2 Storage Temp. -30˚C to 71˚C (-22˚ to 159.8˚F)
upgrade installed) 95% (+5%) from 5° to 30°C (41˚
Relative Humidity
141751** Kit, UAT upgrade (includes Opt. 5 and Mod 2 to 86˚F)
factory upgrade) 75% (+5%) from 30° to 40°C (86˚
to 104˚F)
140609** 6000OPT6 ADS-B Integrity Test Option 45% (+5%) from 40° to 55°C
**This option includes cables and accessories (104˚ to 131˚F)
UC-584 Coupler
Extended Warranty
84373 3 Years with scheduled calibration
84374 5 Years with scheduled calibration