Sbul 139 MK1 Main AC Transformer
Sbul 139 MK1 Main AC Transformer
Sbul 139 MK1 Main AC Transformer
139
29 March 2011
Page 1 of 4
Priority: Urgent
If sufficient time is not available to perform the exchange, verify that the Pikatron
transformer is installed to the highest point to prevent possible contact with moving
parts. Notify the customer of the need to schedule the verification/exchange at the
next service opportunity and make note on the Service Report to be signed by
customer. Alert your service coordinator for follow-up.
Charges:
Service charges to replace the transformer will be absorbed by Northrop Grumman
Sperry Marine B.V. (Europe) per standard warranty terms and conditions.
The charge number is "E00003000".
Approved:
K. Neugebauer
Product Support
Sperry Marine Hamburg
Northrop Grumman Sperry Marine B.V.
Woltmanstrasse 19, D - 20097 Hamburg, Germany
Service: Tel.: +494029900289; Fax +49 40 299 00 146; Email
service.de@sperry.ngc.com
1. Ensure that you are wearing the ESD wristband and that it is properly grounded.
2. If the gyrocompass system is already installed and operative, power it down.
Safeguard the main and backup power supplies against accidental switching-on.
3. Remove the door from the NAVIGAT X MK 1 housing.
4. In case of an already installed system, remove the gyrosphere container,
according to Manual 056343 Reference Chapter 5, ‘Removing the container from the
compass housing’.
NOTE: The gyrosphere container with installed gyrosphere must be
handled with extreme care and kept in an upright position at all times.
5. Unplug all connectors from their sockets on the master board, then unscrew and
remove the complete master board assembly from the housing.
6. Unscrew and remove the complete base plate assembly from the housing.
7. Verify the model of power transformer installed per Figures (1) and (2) and any
affixed labels.
a. If the power transformer is a incorrect brand, replace it with the correct model
Moeller-Preussler per steps 8-14.
b. If a Moeller Preussler is already installed verify the transformer is installed in the
highest possible position afforded by the slotted holes in the transformer mounting
base. Intent is to maximize the distance between the transformer and the bellows
assembly. Adjust if required. See Figure (3). Reassemble the gyrocompass per
steps 10-14.
Northrop Grumman Sperry Marine B.V. (Representative Office)
Woltmanstrasse 19, D – 20097 Hamburg, Germany
Service: Tel.: +49 – 40- 299 00 289; Fax +49 – 40- 299 00 146; Email service.de@sperry.ngc.com
Sperry Marine Hamburg Service Bulletin No. 139
29 March 2011
Page 3 of 4
8. Unplug all wires and the wire links from the transformer's terminal strip. Unscrew
the ground strap from the ground terminal. Loosen and remove the transformer
mounting bolts and remove the incorrect power transformer from the compass
housing.
9. Install the new Moeller-Preussler transformer:
a. Re-install the required wire link(s).
For connection to 230 VAC, terminal 5 must be linked to terminal 6.
For connection to 115 VAC, terminal 4 must be linked to terminal 6 and terminal 5 to
terminal 7.
b. Fasten the transformer to the housing.
Note: Position the transformer to the highest possible position afforded
by the slotted holes in the transformer mounting base intent is to maximize the
distance between the transformer and the bellows assembly. See Figure (3).
c. Re-install the connection wires and the ground strap.
10. Re-install the base plate assembly.
11. Re-install the master board assembly and plug all connectors back into their
sockets on the master board.
12. In case of an already installed system, re-install the gyrosphere container,
according to Manual 056343 Reference Chapter 5,
“Re-installing the container in the compass housing.”
NOTE: The gyrosphere container with installed gyrosphere must be
handled with extreme care and kept in an upright position at all times.
13. Re-install the door onto the NAVIGAT X MK 1 housing.
14. To put an already installed system back into operation, switch on the main and
backup power supplies. Observe the power-up and settling phase and verify the
correct function of the compass system.
___________________________________
K. Neugebauer
Product Support
Sperry Marine Hamburg
Figures:
incorrect power
transformer
outline shape
Top of
Cabinet Position the
transformer to
the highest
possible position
afforded by the
slotted holes