FLUX-CORED GAS-SHIELDED (FCAW-G) WIRE

UltraCore 71A75 Dual ®

Mild Steel, All Position • AWS E71T-1C-H8, E71T-9C-H8, E71T-1M-H8, E71T-9M-H8

Key Features Conformances


Fast freezing slag for out-of-position welding AWS A5.20/A5.20M: 2005 E71T-1C-H8, E71T-1M-H8,
Designed for welding with either 100% CO2 E71T-9C-H8, E71T-9M-H8
or 75% Argon/25% CO2 shielding gases ASME SFA-A5.20: E71T-1C-H8, E71T-1M-H8,
E71T-9C-H8, E71T-9M-H8
Premium arc performance and bead CWB/CSA W48-06: E491T-9 H8, E491T-9M H8
appearance
EN ISO 17632-B: T493T1-1MA-H10,
T493T1-1CA-H10

Typical Applications Welding Positions


General fabrication All

Shielding Gas
100% CO2
75% Argon / 25% CO2
Flow Rate: 40 - 50 CFH

DIAMETERS / PACKAGING
Diameter 15 lb (6.8 kg) Plastic Spool 33 lb (15 kg) 50 lb (22.7 kg) 500 lb (227 kg)
in (mm) 60 lb (27.2 kg) Master Carton Spool* Fiber Spool Accu-Trak® Drum
0.045 (1.1) ED031882 ED031669 ED031844 ED032044
0.052 (1.3) ED031670 ED031845
1/16 (1.6) ED031671 ED031846 ED032046
*Spool may be plastic or fiber.

MECHANICAL PROPERTIES (1) – As Required per AWS A5.20/A5.20M: 2005


Yield Tensile Charpy V-Notch
Strength(2) Strength Elongation J (ft•lbf)
MPa (ksi) MPa (ksi) % @ -18°C (0°F) @ -29°C (-20°F)
Requirements(4)
AWS E71T-1C-H8, E71T-1M-H8 400 (58) 480-655 22 27 (20) min. Not Specified
AWS E71T-9C-H8, E71T-9M-H8 min. (70-95) min. Not Specified 27 (20) min.
Typical Results(3)
As-Welded with 100% CO2 510-550 (73-79) 570-600 (82-87) 26-28 38-95 (28-70) 27-65 (20-48)
As-Welded with 75% Ar/25% CO2 570-610 (82-88) 620-660 (89-95) 24-26 62-111 (46-82) 39-85 (29-63)

120 ı THE LINCOLN ELECTRIC COMPANY


FLUX-CORED GAS-SHIELDED (FCAW-G) WIRE
®
UltraCore 71A75 Dual
(AWS E71T-1C-H8, E71T-1M-H8, E71T-9C-H8, E71T-9M-H8)

DEPOSIT COMPOSITION(1) – As Required per AWS A5.20/A5.20M: 2005


Diffusible Hydrogen
%C %Mn %Si %S %P (mL/100g weld deposit)
Requirements(4)
AWS E71T-1C-H8, E71T-1M-H8 0.12 1.75 0.90 0.03 0.03 8.0
AWS E71T-9C-H8, E71T-9M-H8 max. max. max. max. max. max.
Typical Results(3)
As-Welded with 100% CO2 0.03-0.04 1.28-1.41 0.42-0.49 0.01 0.01-0.02 3-8
As-Welded with 75% Ar/25% CO2 0.03-0.04 1.45-1.60 0.54-0.62 0.01 0.01-0.02 4-8

TYPICAL OPERATING PROCEDURES


Diameter, Polarity CTWD(6) Wire Feed Speed Voltage Approx. Current Melt-Off Rate Deposition Rate Efficiency
Shielding Gas(5) mm (in) m/min (in/min) (volts) (amps) kg/hr (lb/hr) kg/hr (lb/hr) (%)
All Position
4.4 (175) 20-25 135 1.8 (4.0) 1.6 (3.5)
6.4 (250) 21-26 150 2.6 (5.7) 2.3 (5.0)
7.6 (300) 22-27 165 3.1 (6.8) 2.7 (6.0)
0.045 in (1.1 mm), DC+ 8.9 (350) 23-28 190 3.6 (8.0) 3.2 (7.0)
75% Ar/25% CO2 25 (1) 10.2 (400) 24-29 205 4.1 (9.1) 3.6 (8.0) 86-88
Flat & Horizontal
11.4 (450) 25-30 225 4.7 (10.3) 4.1 (9.0)
12.7 (500) 26-31 245 5.2 (11.4) 4.5 (10.0)
14.0 (550) 27-32 265 5.7 (12.5) 5.0 (10.9)
15.2 (600) 27-33 285 6.2 (13.7) 5.4 (11.9)
All Position
3.8 (150) 20-25 155 2.0 (4.5) 1.8 (3.9)
5.1 (200) 21-26 165 2.7 (6.0) 2.4 (5.2)
6.4 (250) 22-27 190 3.4 (7.5) 2.9 (6.5)
0.052 in (1.3 mm), DC+ 7.6 (300) 23-28 215 4.1 (9.0) 3.5 (7.8)
75% Ar/25% CO2 25 (1) 8.9 (350) 24-29 235 4.7 (10.5) 4.1 (9.1) 86-88
Flat & Horizontal
9.5 (375) 25-30 255 5.1 (11.2) 4.4 (9.8)
10.8 (425) 27-31 275 5.8 (12.7) 5.0 (11.1)
12.1 (475) 28-33 295 6.4 (14.2) 5.6 (12.4)
12.7 (500) 29-35 325 6.8 (15.0) 5.9 (13.0)
All Position
3.2 (125) 20-25 195 2.4 (5.3) 2.1 (4.6)
4.4 (175) 21-26 215 3.3 (7.4) 2.9 (6.4)
5.1 (200) 22-27 235 3.8 (8.4) 3.3 (7.3)
1/16 in (1.6 mm), DC+ 5.7 (225) 23-28 265 4.3 (9.5) 3.7 (8.2)
75% Ar/25% CO2 25 (1) 6.4 (250) 24-29 285 4.8 (10.5) 4.2 (9.2) 86-88
Flat & Horizontal
7.6 (300) 25-31 315 5.7 (12.6) 5.0 (11.0)
8.3 (325) 25-32 335 6.2 (13.7) 5.4 (11.9)
8.9 (350) 26-33 365 6.7 (14.7) 5.8 (12.8)
10.2 (400) 28-35 405 7.6 (16.8) 6.6 (14.6)
(1)
Typical all weld metal. (2)Measured with 0.2% offset. (3)See test results disclaimer below. (4)As-Welded with 100% CO2 & As-Welded 75% Argon / 25% CO2. (5) When welding under CO2, increase voltage by 1 Volt. (6)To estimate ESO, subtract 1/4 in (6.0 mm) from CTWD.
NOTE: This product contains micro-alloying elements. Additional information available upon request.

W E L D I N G C O N S U M A B L E S C ATA L O G ı 121
Material Safety Data Sheets (MSDS) and Certificates of Conformance are available on our website at www.lincolnelectric.com

T E S T R ESU LT S
Test results for mechanical properties, deposit or electrode composition and diffusible hydrogen levels were obtained from a weld produced and tested according to
prescribed standards, and should not be assumed to be the expected results in a particular application or weldment. Actual results will vary depending on many factors,
including, but not limited to, weld procedure, plate chemistry and temperature, weldment design and fabrication methods. Users are cautioned to confirm by qualification
testing, or other appropriate means, the suitability of any welding consumable and procedure before use in the intended application.

CUS T OM E R A SSI STA N C E P O L I C Y


The Lincoln Electric Company is manufacturing and selling high quality welding equipment, consumables, and cutting equipment. Our challenge is to meet the needs of our
customers and to exceed their expectations. On occasion, purchasers may ask Lincoln Electric for information or advice about their use of our products. Our employees respond
to inquiries to the best of their ability based on information provided to them by the customers and the knowledge they may have concerning the application. Our employees,
however, are not in a position to verify the information provided or to evaluate the engineering requirements for the particular weldment. Accordingly, Lincoln Electric does not
warrant or guarantee or assume any liability with respect to such information or advice. Moreover, the provision of such information or advice does not create, expand, or alter
any warranty on our products. Any express or implied warranty that might arise from the information or advice, including any implied warranty of merchantability or any warranty
of fitness for any customers’ particular purpose is specifically disclaimed.

Lincoln Electric is a responsive manufacturer, but the selection and use of specific products sold by Lincoln Electric is solely within the control of, and remains the sole
responsibility of the customer. Many variables beyond the control of Lincoln Electric affect the results obtained in applying these types of fabrication methods and service
requirements.

Subject to Change – This information is accurate to the best of our knowledge at the time of printing. Please refer to www.lincolnelectric.com for any updated information.

THE LINCOLN ELECTRIC COMPANY


22801 St. Clair Avenue • Cleveland, OH • 44117-1199 • U.S.A.
Phone: +1.216.481.8100 • www.lincolnelectric.com
© Lincoln Global, Inc. All Rights Reserved.
Issue Date 01/12