Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

TPI600

Download as doc, pdf, or txt
Download as doc, pdf, or txt
You are on page 1of 10

TPI600 Pressure&Temperature Indicator Manual TPI600 pressure indicator is a 1/8 DIN or DIN, panel-mount, dual 4-digit indicator, which

h takes
the advantage of latest state-of-art technology and comes in small-size, light-weight and in low-power. This pressure indicator has been specifically designed for use with mv/Volt output transducers from different

famous manufacturers such as Dynisco, Gefran, ONEhalf20 and so on. Together with the mv/Volt transducers and thermocouple, TPI600 Pressure Indicator can be working as the high precision pressure
and temperature measurement. outputs the control relays timely.

TPI600

Pressure indicator displays the pressure and temperature and

TPI600 Indicator Specification

(1) (2) (3) (4) (5) (6) (7) (8) (9) (10) (11) (12) (13) (14) (15) (16) (17) (18)

Display Resolution LEDs Input Sensibility Sampling Speed Excitation Voltage Temperature Input All Output Relays Retransmission Communication Alarm Range Temperature Humidity Calibration Power Supply Size Panel Cutout Weight

Dual 4-digit Green and Red LEDs 0.2% FSO 1 Out, Alarm-1, Alarm-2, CALibration 2.5mv/V or 3.3 mv/V (automatic selection) 20 per second +9 VDC (output to transducer) Thermocouple E, J, K Relay 220V 1A 4~~20 mA standard current loop RS-485 MODBUS 0001 9999 PSI or Bar (configurable) 0 - 55C <= 80% RH 80% FSO (Full Scale Output) 110/220VAC or +24VDC (designated while purchasing) TPI600: 96mm48mm100 mm (W x H x D)

TPI600: 92mm x 46mm (W x H)


400(Maximum) grams

TPI600 Pressure&Temperature Indicator Manual

TPI600

TPI600 Pressure&Temperature Indicator Manual

(1) OUT LED turns on when the pressure is not less than the OUT setting value. AL-1 LED turns on when the pressure is not less than the AL-1 setting value. AL-2 LED keeps reserved. (2) CAE LED truns on when the <CAE> is pressed for checking the calibration. (3) PV window displays the actual pressure value. (4) SV windows displays the OUT setting value. (5) <AC> key: to clear the pressure value when it is under setting and no load is on (6) <CAE> key: to check the calibration value (80% of Full Scale Output). (7) <SET> key: to enter the setting mode and to exit the setting mode. <SET> key has longer-time(more than 3 Second) press and shot-time press. (8) > key: shift the digit to be edited (9) key: to edit and increase the value

Indicator Model Ordering guide

TPI600 -H S 4 1 2 3 R N
9 Alarm1 N/O

C 10
Alarm 1 Common D

A
Signal+ (Red) 1 EXC + (White) 2

Model Panal Cutout Size 96*96 96*48 48*96 Number of Display Digits Alarms 1 Alarm relay 2 Alarm relay 3 Alarm relay Retransmission Retransmission No Retransmission Communication 11 Communication RS-485 12 13 MainOUT Power supply MainOUT MainOUT N/C Common +24VDC N/O +220VAC
Signal (Black) 3
EXC&CAL1 (Green&Blue)

TPI600 Pressure&Temperature Indicator Manual TPI600 Wiring Diagram


14 VAC 100 / 240 15 LN 16 Ground

CAL2 (Orange) 5

No connection 6

T/C Input+ 7

T/C Input 8

TPI600 Wiring Diagram


1 2 Signal + (Green& Blue) EXC + Re-trans mA+ Re-trans 17 18 9 1 Alarm 1 N/O Alarm 1

(EXC=Excitation)

0 (Red) 3 4 Signal (White) EXC & CAL1 (Orange) 5 CAL2 (Black) 6 7 No connection T/C Input + T/C Input (CAL=Calibration) mA No connection
B

Common 19 20 1 1 1 2 1 3 1 4 1 5 1 6 Main OUT N/C Main OUT Common 21 Main OUT N/O 22 23 VAC 100 / 240 LN

(RS485) +A (RS485) Alarm 4 N/C Alarm 4 Common Alarm 4 N/O

(T/C=Thermocouple)

24

Ground

TPI600 Pressure&Temperature Indicator Manual TPI600 Indicator Module description


There are three kinds of Modules: 1. Relay output module 2. Current output module ( 4-20mA) , configurable into (0-20mA), (0-10V ) with 500ohm(1% accuracy) resistor in the current loop. 3. Communication module (RS-485). 1.Relay Output Module One main OUT relay has 3 connection terminals with SPDT NC/NO.

Alarm-1 output relay is either NO or NC, determined by the Jumper selection on the CON1 beside the relay inside. NO State when having the short circuit piece between B,C(Factory default).NC State when having the short circuit piece between A, B. Alarm -4 output relay has 3 connection terminals with SPDT NC/NO. 2.Current output module (Retransmission) The indicator exports the corresponding pressure value on 420mA(refer to Alarm-2 setting) currentloop.It gives out 4mA(setting -dL-=4mA) when the Pressure Value<=0; The current loop output exports 20mA (setting -dH-=20mA) when the pressure value>=full Scale Output. Please refer to the explain of operation in this manual to know how to set dL- and dH- setting values. The (020mA) current output is obtained by setting dL-=0mA; -dH-=20mA. The voltage output(0-10V) is obtained on the resistor of 500ohm in the 020mA current output loop (DL=0mA;DH=20mA). Setting of Alarm -2 is used for this retransmission current output setting. The retransmission module is exclusive to RS-485 Communication Module.

TPI600 Mounting

You might also like