Shopping Center Space Programming
Shopping Center Space Programming
(SPACE PROGRAMMING)
BS ARCH 4B
ADMIN DEPARTMENT
Supervisors Office 1 3 10 sq. m 30 sq. 30 sq. Provides office support to Adjacent to the Planning and
conference room
m m either an individual or team Designers
and market
and is vital for the smooth- Handbook by
collector office.
running of a business. Max B.
Secretary office 1 2 10 sq. m 20 sq. 20 sq. Formulates and enforces a Adjacent by Fajardo Jr.
m m management control the (Space
system to measure and supervisor’s, allowances)
evaluate performance of office
the Department and
submits periodic reports to
the Supervisor.
Lounge 1 15 2 sq. m 30 sq. 30 sq. A space that are meant to Adjacent by
m m welcome and direct the staff’s
tenants and visitors, entance.
control access, and
provide exit ways from
buildings.
Conference Room 3 15 3 sq .m 45 sq. 135 sq. A room where meetings Adjacent to Planning and
administrative
m m are held and admins Designers
offices.
gathered Handbook by
Max B.
Fajardo Jr.
(Typical
Space
Allotment)
Accounting office 1 20 1.20 sq. 24 sq. 24 sq. It provides accounting Planning and
m m m services Designers
And manages the finances Handbook by
of a Max B.
Company. Fajardo Jr.
Sales office 1 20 1.20 sq. 24 sq. 24 sq. A direct link between a (Space
m m m company's product or allowances)
service and
its customers.
Security office 1 10 1.5 sq. m 15 sq. 15 sq. It is where the building is
m m being monitored for public
safety.
Human resource 1 5 2 sq. m 10 sq. 10 sq. It is where the coordination
office m m of an organization is done
to achieve business
objectives, fulfill staffing
needs, and maintain
employee satisfaction.
Collector’s office 1 6 4 sq. m 24 sq. 24 sq. To collect land revenue
m m and government dues.
Clinic 1 10 4.9 sq. m 49 sq. 49 sq. Organized medical service Free access to National
m m offering diagnostic, the public Building Code
therapeutic, or preventive areas of the
outpatient services. Philippines
Male toilets 1 6 2 sq.m 12 12 Provide far more than Adjacent to Planning and
sq.m sq. m access to the toilet for female toilet Designers
Female toilets 1 6 2 sq.m 12 12 sq.m urination and defecation. Adjacent to Handbook by
sq.m male toilet Max B.
Fajardo Jr.
TOTAL AREA FOR ADMIN DEPT. =385 sq.m
STAFF’S DEPARTMENT
Staff entrance 1 10 1.20 12 12 sq.m To allow staff to get Accessible
sq.m sq.m entered and near to
the lobby
Staff lounge 1 30 1 sq.m 30 30 To have a space for Adjacent to
sq. m sq. m drivers and staff to relax, staff toilets.
get comfy and unwind.
Pantry 1 10 1.5 sq. m 15 15 sq.m Adjoining area to the Accessible to National
sq.m kitchen from where the all staffs. Building Code
Kitchen 1 n/a 1.70 n/a 1.02 finished food/drink is ready of the
Counter x .6m in sq. m to be served and stored. Philippines
dimensio
n
Staff locker room 1 30 1.4 sq.m 42 42 sq.m For changing clothes and Adjacent to
sq.m for storing clothing and staff toilets.
equipment in lockers.
Shower area 2 6 2.05 12.3 24.6 An area in which a person Adjacent to
sq.m sq. m sq. m bathes under a spray of staff toilets. Planning and
typically warm or hot
water. Designers
Staff toilets 2 6 2.05 12.3 24.6 Provide access to the toilet Adjacent to Handbook by
sq.m sq. m sq. m for urination and drivers and Max B.
defecation of the staff. staff lounge. Fajardo Jr.
Maintenance 1 n/a n/a 80 sq. 80 sq. Where sanitary equipment It must be a
Room/ Sanitary m m and close space to
Storage Other maintenance is avoid hazards
stored from the
public.
TOTAL AREA FOR STAFF’S DEPT. = 229.22 sq. m
ELECTRICAL 1 N/A N/A 50 sq. 50 sq. Providing a space that is Adjacent to
ROOM m m both safe and secure for mechanical
the operation and room
maintenance of the
electrical equipment.
MECHANICAL 1 N/A N/A 50 sq. 50 sq. Dedicated to the Adjacent to
ROOM m m mechanical equipment and electrical room
its associated electrical
equipment.
GENERAL 1 N/A N/A 200 200 Involves holding goods Near to stores Planning and
STORAGE SQ.M SQ.M between the time of their and rentable Designers
production and their final spaces Handbook by
sale. ' It bridges the gap Max B.
between the time when Fajardo Jr.
goods are produced and
the time when these are
ultimately consumed as
there is always a time gap
between production and
consumption.
HALLWAYS AND
CORRIDORS
TOTAL AREA FOR PRIVATE SPACES = 914.22 sq. m
PUBLIC SPACES
ENTRANCES AND 5 20 1.5 sq. m 30 sq. 150 sq. The entrance and exit
EXIT m m facility of the shopping A space in a
communication. Handbook by
COMMUNITY 1 30 4.6 138 138 Providing customers with Slightly private Max B.
BANK sq.m/ sq. m sq. m facilities of foreign area and has Fajardo Jr.
accessible Requirements
building
entrances
Terminal (jeepney) 6 n/a 3 x 9 mts 27 sq. 162 sq. Carry passenger for a fee Access in
m m and offering services to the entrance and
public. exits along the
road
Driveways n/a n/a 3m in Driveways for vehicles to Consider
width roam around easily to their pedestrians
destination
Delivery Parking 8 n/a 4m x 48 sq. 384 sq. A space for delivery trucks Adjacent to
12m m m being accommodated. delivery drop
off area
Delivery Drop-Off 2 n/a 4m x 48 sq. 96 sq. Serves as the picking up Provide ample
Area 12m m m or releasing products space for the
trucks and
must be NBC-
Parking Spaces 1200 n/a 3m. x 21,60 21,600 Provide spaces to vehicles Location of the Requirements