TrueAlert Addressable Notification Appliances

UL, ULC, CSFM Listed* Audible/Visible Notification Appliances;


FM Approved* Multi-Tone Horn/Strobe with 520 Hz Output

Features
Individually addressed and controlled multi-tone
and multi-candela TrueAlert ES A/V (audible/visible)
notification appliances provide:
 Multi-candela xenon strobe with synchronized 1 Hz flash
rate and with intensity programmable from the control
panel or jumper selected as 15, 30, 75, 110, 135, or
185 cd
 Advanced addressable notification controlled by IDNAC
SLCs providing regulated 29 VDC allowing strobes to
operate with lower current even under battery backup
 Wiring supervision to each appliance allowing
“T-tapped” connections for Class B circuits to
simplify wiring (Class A circuits require in/out
wiring)
 Self-Test Mode allows on-board sensors to detect the
strobe and horn output and then report their status to TrueAlert ES Multi-Tone Addressable A/Vs are Available
the control panel in Red with White Lettering and White with Red Lettering
 Per appliance tone selection of: 520 Hz Horn, Features (Continued)
Broadband Horn, Bell, Chime, High/Low, Slow
Mechanical design features include:
Whoop, or Siren; programmable from the control
 Rugged, high impact, flame retardant thermoplastic
panel, or selected using an on-board DIP Switch (refer
housing in red with white letters or white with red letters,
to sound output details on page 4) with clear lens, available with FIRE, FEU, ALERT,
 520 Hz tone is compliant with NFPA 72 Low FEU/FIRE, or blank lettering
Frequency Signal Requirements for Sleeping Areas  Separate covers are available to change application type
 Horn, Bell, and High/Low tones can be controlled as: on-site or for replacement; covers can be easily removed
Temporal Code 3, Temporal Code 4, March Time without disturbing the connected housing and avoiding
(selectable as 20, 60, or 120 bpm), or Continuous trouble conditions
 Slow Whoop, Siren, and Chime tone selections are  A separate mounting plate allows wiring to be completed
before appliance is mounted; use with single gang, double
controlled as synchronized continuous operation
gang, or 4-inch square box, flush or surface mount
 Output of “high” or “low” (~6 dBA difference)  In/out wiring terminals for 18 AWG to 12 AWG
selectable at the appliance or from the controller with
 Optional mounting adapters are available to cover
FACP mode selected at the appliance
surface mounted electrical boxes and to adapt to Simplex
 TrueAlert Device Reports at the control panel 2975-9145 boxes
detailing appliance point ID, custom label, type, and
candela setting (see sample on page 3) Description
 Magnet Test diagnostics to assist checkout and testing TrueAlert ES addressable multi-tone A/Vs are
of appliances and wiring individually addressed audible/visible notification
 Electrical test point access without removing cover appliances that receive power, supervision, and control
 Compatibility with ADA requirements; (refer to signals from a Simplex fire alarm control panel providing
important installation information on page 3) IDNAC Signaling Line Circuits (SLCs). (See
compatibility list on page 4.)
 Strobe operation is listed to UL Standard 1971 and
ULC Standard S526; Horn operation is listed to UL Strobe Application Reference
Standard 464 and ULC Standard S525 Proper selection of visible notification is dependent on
LED Indicator and Magnet Test feature: occupancy, location, local codes, and proper applications
 Appliance LED can be selected to display each polling of: the National Fire Alarm Code (NFPA 72), ANSI
cycle to indicate appliance supervision A117.1; the appropriate model building code: BOCA,
 When the controller is in diagnostic mode, the Magnet ICBO, or SBCCI; and the application guidelines of the
Test pulses the LED to indicate appliance address and Americans with Disabilities Act (ADA).
can be set to also briefly flash the strobe and sound the * This product has been approved by the California State Fire Marshal (CSFM) pursuant to
Section 13144.1 of the California Health and Safety Code. See CSFM Listing
horn 7135-0026:0380 for allowable values and/or conditions concerning material presented in
this document. Additional listings may be applicable; contact your local Simplex product
supplier for the latest status. Listings and approvals under Simplex Time Recorder Co.
are the property of Tyco Fire Protection Products.

S49MTV-0001-6 7/2016
TrueAlert ES Operation Advantage TrueAlert ES Diagnostics
TrueAlert ES addressable appliances on IDNAC Test Features. When IDNAC SLCs are in diagnostic
SLCs provide separate visible and audible notification mode, Self-Test and Magnet Test features provide individual
using a single two-wire circuit that also confirms appliance testing. With the Self-Test feature, appliance
connection to the individual notification appliance’s operation can be confirmed without leaving the control panel.
electronic circuit. This operation increases circuit Additionally, each appliance’s LED can be selected to pulse
supervision integrity by providing supervision that when it receives a supervision poll during normal operation.
extends beyond the appliance wiring connections. Self-Test Details. Selecting Self-Test Mode from the control
Reduced current allows efficient IDNAC SLC panel allows on-board sensors, depending on the device type, to
operation. With IDNAC SLCs, a constant 29 VDC detect its own strobe and/or horn output and then report their
source voltage is maintained, even during battery standby, status to the control panel. Operation is by selected VNAC
allowing strobes to operate at higher voltage with lower appliance groups and is either automatic (all briefly
current and ensuring a consistent current draw and voltage simultaneously activated) or individually activated by applying
drop margin under both primary power and secondary a magnet. (Refer to control panel data sheet for more Self-Test
battery standby. Efficiencies include wiring distances up information, see list on page 4.)
to 2 to 3 times farther than with conventional notification, Silent Appliance Magnet Test. In this test mode, in
or support for more appliances per IDNAC SLC, or use of response to application of a magnet, the appliance LED pulses
smaller gauge wiring, or combinations of these benefits, sequentially to conveniently indicate the appliance’s address.
all providing installation and maintenance savings with Operational Appliance Magnet Test. In this test mode,
high assurance that appliances that operate during normal after the address is indicated by pulsing the appliance LED, the
system testing will operate during worst case alarm strobe will briefly flash and the horn will briefly sound to
conditions. indicate proper operation.
Reducing Installation and Testing Time. With TrueStart Instrument Two (TSIT). The 2nd generation of
separate controls on the same two-wire SLC, installation the Simplex TrueStart Test Instrument adds testing of IDNAC
time and expense for both retrofit and new construction SLC wiring and TrueAlert ES appliances to its ability to test
can be significantly reduced. When Class B wiring is IDCs, NACs, and IDNet communications before connection to
used, wiring can be “T” tapped, allowing more savings in the control panel. Please contact your local Simplex
distance, wire, conduit (size and utilization), and overall representative for additional information.
installation efficiency. Use of Self-Test and Magnet Test
features improve installation efficiency. TrueAlert device
TrueAlert Addressable Wiring Isolator
reports conveniently identify information about each Isolator Model 4905-9929 is available for remote mounting
connected appliance. on TrueAlert addressable circuits to isolate short circuited
wiring from functioning wiring. (See data sheet S4905-0001.)
Product Selection
TrueAlert ES Wall Mount Multi-Tone Addressable Audible/Visible Appliances
TrueAlert ES multi-tone addressable A/V appliances include cover and matching mounting plate except as noted;
Dimensions with Cover = 5 ⅛” H x 5” W x 2 ⅝” D (130 mm x 127 mm x 67 mm)
Model* Cover Color Wording Lens Color Model* Cover Color Wording Lens Color
49MTV-WRF(-BA) Red 49MTV-WRS-BA Red
FIRE Clear Blank Clear
49MTV-WWF(-BA) White 49MTV-WWS-BA White
49MTV-APPLW(-BA) Select cover and mounting plate separately
Separate Mounting Plate (Required when ordering model 49MTV-APPLW(-BA))
Model* Color Model Color Note
49MP-AVVOWR Red 49MP-AVVOWW White Mounting Plate, select color to match cover
* Note: (-BA) indicates model is available either with or without the -BA suffix. Model numbers ending in -BA, APPLW models, and separate
mounting plates are assembled in the USA.
Separate Covers (Required when ordering model 49MTV-APPLW(-BA), uses same covers as 49AV Series fixed tone A/Vs)
Model Color Wording Model Color Wording
49AVC-WRFIRE Red 49AVC-WRFEU Red
FIRE FEU
49AVC-WWFIRE White 49AVC-WWFEU White
49AVC-WRALT Red 49AVC-WRBLNG Red
ALERT FEU/FIRE
49AVC-WWALT White 49AVC-WWBLNG White
49AVC-WRS Red Logos Only 49AVC-WWS White Logos Only
Mounting Adapters
Model Color Description Dimensions
4905-9937 Red 5 ⅜” H x 5 ¼” W x 1 ⅝” D (136 mm x 133 mm x 41 mm)
Surface Mount Adapter Skirt
4905-9940 White Total depth with strobe = 4 ⅜” (111 mm)
Red Adapter Plate for mounting to Simplex 2975-9145 Box 5
4905-9931 8 ⁄16” x 5 ¾” x 0.060” Thick (211 mm x 146 mm x 1.5 mm)
(typically for retrofit, mount vertical or horizontal)
2975-9145 Red Mounting Box, requires 4905-9931 Adapter Plate 7 ⅞" x 5 ⅛" x 2 ¾" D (200 mm x 130 mm x 70 mm)

2 S49MTV-0001-6 7/2016
TrueAlert Device Reports Reference
Service Port Page 1
REPORT 5 : TrueAlert Device Report 12:34:56am TUE 10-Mar-15
DEVICE
POINT ID CUSTOM LABEL TYPE CANDELA
T14-1-1 Location Label . . . up to 40 characters MT AV 15
T14-1-2 Break Room 5 MT AV 110
T14-1-3 Boiler Room VO 75
T14-1-4 Elec. Room 7 AV 135

Installation Reference

Mounting is compatible with single gang,


double gang, and 4" (102 mm) square boxes, IMPORTANT! WALL MOUNT
1-1/2" (38 mm) deep, supplied separately INSTALLATION HEIGHT REFERENCE
Wiring terminals and
connection clips
Electrical
Transparent A/V configuration switch box outline
housing assembly accessible from rear of
housing (not shown)
Removable cover (when
installed, use flat bladed
screwdriver to release latch
on left side) Bottom of lens is
either even with, or
slightly above bottom
of compatible boxes
Wiring access
hole 80" (2.03 m)
minimum
LED indicator
Address setting DIP location Mounting plate NFPA 72 requires
switch, accessible that the entire lens be
Mounting Holes:
from rear of housing not less than 80" and
Single gang (2) not greater than 96"
Magnetic test location Double gang (4) above the finished
(bottom of housing) 110 4" square (4) floor (confirm with
75 your local codes)
30 Intensity selection
Strobe intensity 15 plug, accessible
viewing slot on FACP from rear of
side of appliance housing; factory
135 setting is FACP,
Electrical test point access holes (not to scale) 185
(on bottom) controlled by panel

Adapter Plate and Surface Mount Installation Reference


2975-9145 Box Mounting Reference
4905-9931 Adapter Plate Surface Mount Side View Reference
2975-9145 Box
(Surface mount conduit and
box shown for reference)

TrueAlert ES
Multi-Tone
Addressable A/V

4" square box profile,


1-1/2" (38 mm) deep
4905-9931 Adapter Plate
TrueAlert ES Multi-Tone Optional surface mount adapter skirt,
Addressable A/V 1-1/2" deep: 4905-9937, Red;
4905-9940, White (conduit knockouts
are provided on all four sides)

3 S49MTV-0001-6 7/2016
IDNAC SLC Controller Compatibility Reference
Data Sheet IDNAC SLC Output Appliance Voltage
Compatible Controllers Controller Output
Reference Voltage Design Reference
4100ES with EPS+ or EPS Power Supply S4100-0100
4009 IDNAC Repeater S4009-0004 29 VDC 23 VDC
IDNAC SLC
4007ES with IDNAC Notification S4007-0002 (regulated) (with 6 VDC drop)
4010ES with ESS Enhanced System Supply S4010-0011

TrueAlert ES A/V Specifications


Typical Operating Voltage Range 23 VDC to 29.5 VDC, Special Application
Electrical Supervisory Requirements 2 unit loads (1 unit load = 0.8 mA control panel current)
Ratings Up to 21 appliances can connect directly to the panel IDNAC SLC or to a 4009 IDNAC
49MTV Series SLC Loading
Repeater output, to a maximum of 127 addresses and 139 unit loads per SLC
IDNAC SLC Wiring Specifications UTP, unshielded twisted pair recommended
(refer to control panel or power supply Maximum wire length allowed with “T-Taps” for Class B wiring per SLC = 10,000 ft (3048 m)
installation instructions for more information) Maximum wire length to any appliance = 4000 ft (1219 m)
Tone Characteristics
520 Hz Horn 520 Hz tone
Broadband Horn Combination 600/3000 Hz signal These tones are compatible with control panel
IDNAC commands for operation as Temporal
Bell Synthesized Bell tone Code 3, Temporal Code 4, March Time at 20, 60,
Alternating modulated tones with fundamentals of 1000 Hz and or 120 bpm, or Continuous operation
High/Low
800 Hz, 250 ms duration each
Slow Whoop Modulated 520 Hz to 1200 Hz sweep with 2 s duration
These tones operate as Continuous with
Siren Modulated 600 Hz to 1200 Hz to 600 Hz sweep, with 2 s duration
synchronization
Chime Multi-phase signal with a peak and decay time of 1 s
TrueAlert ES Multi-Tone Horn/Strobe Current Ratings
RMS Current Ratings @ 23 VDC, in mA
15 cd 30 cd 75 cd 110 cd 135 cd 185 cd
Tone High Low High Low High Low High Low High Low High Low
520 Hz Horn and High/Low 145 108 163 125 198 158 230 195 262 214 299 257
Broadband Horn, Bell, Chime,
135 99 152 111 185 139 212 172 247 203 284 243
Slow Whoop, and Siren
TrueAlert ES Multi-Tone Horn/Strobe Horn Output
UL 464 Output Ratings ULC S525 Output Ratings
@ 23 VDC and 29.5 VDC (dBA)* @ 23 VDC and 29.5 VDC (dBA)*
Steady High Steady Low Coded High Coded Low Steady High Steady Low Coded High Coded Low
Tone Voltage 23 29.5 23 29.5 23 29.5 23 29.5 23 29.5 23 29.5 23 29.5 23 29.5
† † † †
520 Hz Horn 80 80 74** 75 76 76 70** 71** 83 79 83 78
** † † †
High/Low 81 82 77 77 75 76 70 71** 87 82 86 82
† † †
Broadband Horn 84 84 79 79 81 81 74** 75 88 84 87 83
† † †
Bell 80 80 75 75 76 76 71** 71** 85 80 85 80

Slow Whoop 79 80 74** 75 85 80
these tones are not used for † these tones are not used for
Siren 79 80 74** 75 85 80
coded operation † †
coded operation
Chime** 67** 67** 62** 62** 82 77
* Output ratings are at 10 ft (3 m); UL 464 ratings are per UL Reverberant Chamber testing; ULC S525 ratings are per ULC Anechoic
Chamber testing. The tone generator circuit is DC-DC converter powered and provides essentially constant output over the rated voltage
range.
** UL output ratings below 75 dBA are for NFPA 72 Private Mode applications.

ULC output ratings below 85 dBA are for use in applications per applicable local codes.
Sound Output Dispersion per Horizontal -3 dBA @ ±37° -6 dBA @ ±40° -9.4 dBA @ ±90°
ULC S541 Anechoic Testing Vertical -3 dBA @ -24°, +42° -6 dBA @ -59°, +50° -8.6 dBA @ ±90°
General Specifications
Temperature Range 32 to 122 F (0 to 50 C)
Humidity Range 10% to 93%, non-condensing @ 104° F (40° C)
2 2
Terminal blocks on mounting plate for 18 AWG to 12 AWG (0.82 mm to 3.31 mm ); two wires per
Connections
terminal for in/out wiring
579-1156 for 49MTV Series A/V appliances
Installation Instructions
579-1100 for 49MP Series mounting plates
TYCO, SIMPLEX, and the product names listed in this material are marks and/or registered marks. Unauthorized use is strictly prohibited. NFPA 72 and National Fire Alarm Code
are trademarks of the National Fire Protection Association (NFPA).

Tyco Fire Protection Products • Westminster, MA • 01441-0001 • USA S49MTV-0001-6 7/2016


www.simplex-fire.com
© 2016 Tyco Fire Protection Products. All rights reserved. All specifications and other information shown were current as of document revision date and are subject to change without notice.