INSTRUCTIONS FOR INSTALLATION AND MAINTENANCE (GB)

JET 151 – 251 – 200 – 300


DP – AQUADP
EURO – EUROINOX – EUROCOM – EUROCOM SP
GARDEN-INOX
K
KP 38/18 – 60/6 – 60/12
KPA 40/20
JET 151 - JET 251
JET 200 - JET 300

DP 81 - DP 100
DP 82 - DP 102
DP 151 - DP 251

AQUADP 82/20 - AQUADP 102/20


AQUADP 151/40 - AQUADP 251/40

EURO 15/30 - EURO 20/50 - EURO 25/30 - EURO 30/30 - EURO 40/30
EURO 25/306 - EURO 30/306 - EURO 40/306
EUROINOX 15/30 - EUROINOX 20/50 - EUROINOX 25/30 - EUROINOX 30/30
EUROINOX 40/30
EUROINOX 25/306 - EUROINOX 30/306 EUROINOX 40/306
EUROCOM 25/30 - EUROCOM 30/30
EUROCOM 25/306 - EUROCOM 30/306

EURO 30/50 - EURO 40/50 - EURO 50/50


EURO 30/506 - EURO 40/506 - EURO 50/506
EUROINOX 30/50 - EUROINOX 40/50 - EUROINOX 50/50
EUROINOX 30/506 – EUROINOX 40/506 – EUROINOX 50/506
EUROCOM 30/50 - EUROCOM 40/50
EUROCOM 30/506 - EUROCOM 40/506

EURO 25/80 - EURO 30/80 - EURO 40/80


EURO 25/806 - EURO 30/806 - EURO 40/806
EUROINOX 25/80 - EUROINOX 30/80 - EUROINOX 40/80
EUROINOX 25/806 - EUROINOX 30/806 - EUROINOX 40/806
EUROCOM 25/80 - EUROCOM 30/80
EUROCOM 25/806 - EUROCOM 30/806

EUROCOM SP 30/50 - EUROCOM SP 40/50


EUROCOM SP 30/506 - EUROCOM SP 40/506

GARDEN-INOX 30/30 - GARDEN-INOX 40/50

K 20/41 - K 30/70 - K 30/100 - K 36/100


K 12/200 - K 14/400
K 35/40 - K 45/50 - K 55/50
KE 35/40 - KE 45/50 - KE - 55/50
K 35/100 - K 40/100

KP 38/18 - KP 60/6 - KP 60/12 - KPA 40/20


ENGLISH page 5
ENGLISH
CONTENTS page
1. GENERAL 5
2. APPLICATIONS 5
3. PUMPED FLUIDS 5
4. TECHNICAL DATA AND RANGE OF USE 5
5. MANAGEMENT 7
5.1. Storage 7
5.2. Transport 7
5.3. Weights 7
6. WARNINGS 7
6.1. Skilled personnel 7
6.2. Safety 8
6.3 Checking motor shaft rotation 8
6.4 Responsibility 8
7. INSTALLATION 8
8. ELECTRICAL CONNECTION 8
9. STARTING UP 9
10. PRECAUTIONS 9
11. MAINTENANCE AND CLEANING 9
12. MODIFICATIONS AND SPARE PARTS 9
12.1 Removal and replacement of the supply cable 10
13. TROUBLESHOOTING 11
1. GENERAL
Read this documentation carefully before installation. Installation and functioning must comply with
the safety regulations in force in the country in which the product is installed. The entire operation must
be carried out in a workmanlike manner.
Failure to comply with the safety regulations not only causes risk to personal safety and damage to the
equipment, but invalidates every right to assistance under guarantee.
2. APPLICATIONS
KP 38/18 - KP 38/18 pred. - KP 60/6 - KP 60/12: Peripheral pump suitable for domestic use, with limited bulk,
capable of generating high heads for water supply, small gardening jobs, draining and filling cisterns. Also suitable for
small industrial uses.
KPA 40/20: liquid ring pump with star-shaped impeller, with excellent sustion capacities even in the presence of air
bubbles or when the fluid to be lifted is not continuously available. Used particularly for supplying water to household
systems, for increasing pressure or stabilissing the water supply (in compliance with local regulations) and for lifting
water from wells. Suitable for smoll irrigatin work in gardens and in general for all applications where a self-priming
pump is required. It can also satisfy small industial applications.
JET 200 - JET 300 - JET 151 - JET 251: Self-priming centrifugal jet pumps with excellent suction capacity, even
when gas is present in the water. Particularly suitable for water supply uses and for pressurization in the home.
Suitable for small farming applications, market gardens, gardening, emergencies in the home and industrial utilities.
DP 81 - DP 82 - DP 100 - DP 102 - DP 151 - DP 251 – AQUADP 82/20 - AQUADP 102/20 - AQUADP 151/40 -
AQUADP 251/40 : Self-priming centrifugal pumps for suction at depths of as many as 30 metres with ejector to be
fitted in 4" wells or larger. Used for supplying water to farm houses and in small farming applications.
EURO - EUROINOX and derived models: Self-priming multistage centrifugal pump with horizontal action, suitable
for domestic or industrial uses, for water supply systems and pressurization. In farming it is ideal for small irrigation
work and for washing tools and machinery. Also suitable for water containing gas. Water is recycled only during the
priming stage, after which the maximum flow is made available for use with continuous and constant distribution.
These qualities allow vast possibilities for use.
K 20/41 - K 30/70 - K 30/100 - K 36/100 - K 12/200 - K 14/400: Single-impeller centrifugal pumps suitable for lifting
water for domestic, industrial and agricultural use. Excellent for transfer and mixing operations.
K 35/40 - K 45/50 - K 55/50 - K 35/100 - K 40/100: Centrifugal pumps characterized by the use of two impellers
(opposed for models K 35/40 - K 45/50 - K 5/50), with extremely silent operation. Particularly suitable for use in
pressurization units for water supply systems and for feeding autoclaves. Also suitable for sprinkling irrigation and
many other uses in the most varied fields of application.
3. PUMPED FLUIDS
The machine has been designed and built for pumping water, free from explosive
substances and solid particles or fibres, with a density of 1000 kg/m³ and a kinematic
viscosity of 1 mm²/s, and chemically non-aggressive liquids.
4. TECHNICAL DATA AND RANGE OF USE
 Supply voltage: 220 - 240V 50Hz / 110V 50Hz
115V 60Hz / 230V 60Hz / 230 V3 – 400 V3 50/60Hz see electrical
115-127 V 60 Hz / 220-230V 60Hz / 220-277/380-480V 60Hz data plate
 Absorbed power: see electrical data plate

5
ENGLISH

3
Delivery: from 0,06 to 37 m /h
 Head up – Hmax (m): pag. 150
 Pumped liquid: clean, free from solid bodies or abrasive substances, non-aggressive.
 Degree of motor protection: IP44 (For IP55 see plate on package)
 Degree of terminal board protection: IP55
 Protection class: F
 Cable clamp: PG 11 and/or PG 13.5, depending on models
 Line fuses AM class:
Line fuses(Amps)
Model 110V 50Hz 220-240V 50Hz 230 V3 400 V3
115V 60Hz 230V 60Hz 50/60Hz 50/60Hz
127 V 60 Hz
KP 38/18, KP 38/18 Pred., KP 60/6, DP 81, DP 82, AQUADP 82/20 8 4 4 2
K 20/41
KPA 40/20 8 6 4 2
KP 60/12; -- 6 4 4
EURO 40/30-40/306 / 30/50-30/506 / 25/80-25/806 10 6 4 4
EUROINOX 40/30-40/306 / 30/50-30/506 / 25/80-25/806
EUROCOM 25/80-25/806 / 30/50-30/506
EUROCOM SP 30/50-30/506
EURO 25/30-25/306 / 30/30-30/306 8 4 4 4
EUROINOX 25/30-25/306 / 30/30-30/306
EUROCOM 25/30-25/306 / 30/30-30/306
GARDEN-INOX 30/30
EURO 40/50-40/506 / 30/80-30/806 12 6 6 4
EUROINOX 40/50-40/506 / 30/80-30/806
EUROCOM 40/50-40/506 / 30/80-30/806
EUROCOM SP 40/50-40/506
GARDEN-INOX 40/50
EURO 50/50-50/506 / 40/80-40/806 20 8 6 4
EUROINOX 50/50-50/506 / 40/80-40/806
K 12/200, K 30/70, K 35/40, DP 100, DP 102, AQUADP 102/20, KE 35/40 12 6 6 4
K 30/100 16 8 6 4
JET 151, K 35/100 20 10 6 4
K 40/100, K 36/100, K45/50, DP 151, AQUADP 151/40, KE 45/50 20 10 8 4
JET 200, K 14/400 20 10 8 6
JET 251 25 12 8 6
JET 300, K 55/50, DP 251, AQUADP 251/40, KE 55/50 32 16 10 6
Maximun 6 bar (600 kPa): DP 81, DP 82, DP 100, DP 102,
operating pressure: AQUADP 82/20, AQUADP 102/20
EURO, EUROINOX, EUROCOM, EUROCOM SP, GARDEN-INOX
K 35/40, K 35/100, K 40/100, K 20/41, K 30/70, K 30/100, K 36/100, K 12/200, K 14/400,
KE 35/40
7,5 bar (750 kPa): JET 151, JET 251, JET 200, JET 300
DP 151, DP 251, AQUADP 151/40, AQUADP 251/40
8 bar (800 kPa): K 45/50, K 55/50, KE 45/50, KE 55/50
10 bar (1000 kPa): KP 60/6, KP 60/12, KP 38/18
KPA 40/20
Liquid 0 ÷ +35°C: For all homologated pumps
temperature range: EN 60335-2-41 (for domestic uses)
0 ÷ +40°C: JET 151, JET 251, JET 200, JET 300
DP 81, DP 82, DP 100, DP 102, DP 151, DP 251
AQUADP 82/20, AQUADP 102/20, AQUADP 151/40, AQUADP 251/40
-10 ÷ +50°C: K 20/41, K 30/70, K 30/100, K 36/100, K 12/200, K 35/40,
K 45/50, K 35/100, K 40/100
KP 38/18, KE 35/40, KE 45/50
-10 ÷ +80°C: KP 60/6, KP 60/12
KPA 40/20
-15 ÷ +110°C: K 14/400, K 55/50, KE 55/50

6
ENGLISH
 Storage temperature: -10°C to +40°C
 Relative humidity of the air: MAX. 95%
 Noise level:  For pumps intended for outdoor use: noise emission according to Directive
2000/14/CE.
 For other pumps: noise emission according to Directive EC 89/392/CEE and
subsequent amendments.
 Motor construction in conformity with standards CEI 2-3 - CEI 61-69 (EN 60335-2-41).
 The leads of the supply cables must have a rated section no smaller than that illustrated in the
following table:

Rated current: Rated section


of the appliance mm²
A
≤ 0,2 Flat twin tinsel cord a
> 0,2 and ≤3 0,5 a
>3 and ≤6 0,75
>6 and ≤ 10 1,0 (0,75) b
> 10 and ≤ 16 1,5 (1,0) b
> 16 and ≤ 25 2,5
> 25 and ≤ 32 4
> 32 and ≤ 40 6
> 40 and ≤ 63 10
a
These cables may be used only if their length does not
exceed 2 m between the point in which the cable or its
sheath enters the appliance and its entry in the plug.
b
The cables with the sections indicated in brackets may be
used for mobile appliances if their length does not exceed 2
m.

5. MANAGEMENT
5.1 Storage
All the pumps must be stored indoors, in a dry, vibration-free and dust-free environment, possibly with
constant air humidity.
They are supplied in their original packaging and must remain there until the time of installation. If this is
not possible, the intake and delivery aperture must be accurately closed.
5.2 Transport
Avoid subjecting the products to needless jolts or collisions.
To lift and transport the unit, use lifting equipment and the pallet supplied standard (if applicable).
5.3 Weights
The adhesive label on the package indicates the total weight of the electropump.
6. WARNINGS
6.1 Skilled technical personnel
It is advisable that installation be carried out by skilled personnel in possession of
the technical qualifications required by the specific legislation in force.
The term skilled personnel means persons whose training, experience and instruction, as well
as their knowledge of the respective standards and requirements for accident prevention and
working conditions, have been approved by the person in charge of plant safety, authorizing
them to perform all the necessary activities, during which they are able to recognize and avoid
all dangers. (Definition for technical personnel IEC 364).
The appliance is not intended to be used by persons (including children) with reduced physical,
sensory or mental capacities, or who lack experience or knowledge, unless, through the
mediation of a person responsible for their safety, they have had the benefit of supervision or of
instructions on the use of the appliance. Children should be supervised to ensure that they do
not play with the appliance.

7
ENGLISH
6.2 Safety
Use is allowed only if the electric system is in possession of safety precautions in accordance with the
regulations in force in the country where the product is installed (for Italy, CEI 64/2).
6.3 Checking motor shaft rotation
Before installing the pump you must check that the rotating parts turn freely. For this purpose remove the fan
cover from its seat in the motor end cover. Insert a screwdriver in the notch on the motor shaft from the
ventilation side. If there is a blockage, turn the screwdriver, tapping it gently with a hammer. FIG. A
6.4 Responsibility
The Manufacturer does not vouch for correct operation of the pumps if they are
tampered with or modified, run outside the recommended work range or in contrast with
the other instructions given in this manual.
The Manufacturer declines all responsibility for possible errors in this instructions
manual, if due to misprints or errors in copying. The company reserves the right to make
any modifications to products that it may consider necessary or useful, without affecting
the essential characteristics.
7. INSTALLATION

The pumps may contain small quantities of residual water from testing.
We advise flushing them briefly with clean water before their final installation.

7.1 The electropump must be fitted in a well ventilated place, protected from unfavourable weather
conditions and with an environment temperature not exceeding 40°C. Fig.B
7.2 A firm anchoring of the pump to the bearing surface favours the absorption of any vibrations caused
by pump operation. Fig. C
7.3 Ensure that the metal pipes do not exert undue strain on the apertures, thus preventing deformations
or breakages. Fig. C
7.4 It is always good practice to place the pump as close as possible to the liquid to be pumped. The
pump must be installed only in horizontal position. The internal diameters of the pipes must never be
smaller than that of the mouth of the electropump. It is advisable to fit a foot valve on suction. Fig. D
For suction depths of over four metres or with long horizontal stretches it is advisable to use an intake
hose with a diameter larger than that of the intake aperture of the pump. To prevent the formation of air
pockets, the intake hose must slope slightly upwards towards the pump. Fig. D
7.5 If the intake pipe is made of rubber or flexible material, always check that it is of the reinforced type
to avoid throttling due to suction.
7.6 The lifting and carrying handle must always be present and well fixed to the support on all
pumps produced in the portable version.
7.7 Pumps that are to be used in fountains for outdoor use, in garden ponds and similar places,
must be fed by means of a circuit equipped with a differential current device, the rated
operating differential current of which is not higher than 30 mA.
8. ELECTRICAL CONNECTION
Caution! always follow the safety regulations.

Scrupulously follow the wiring diagrams inside the terminal board box.

8.1 Electric installation must be carried out by skilled and authorized electrician who accepts all
the responsibility for the job.
8.2 Ensure that the mains voltage is the same as the value shown on the motor plate and that there is the
possibility of MAKING A GOOD EARTH CONNECTION (Fig. E), in particular the earth
terminal must be connected to the yellow/green lead of the power cable. The earth lead used must
be longer than the phase leads so that it does not disconnect first when subject to traction.
8.3 In fixed installations, International Safety Standards require the use of isolating switches with a
fuse-carrier base.
8.4 Single-phase motors are provided with built-in thermal overload protection and may be connected
directly to the mains. Three-phase motors must be protected with an automatic switch (e.g. overload
protection) set at the values on the electropump data plate, or with fuses of the size indicated in
chapter 4.

8
ENGLISH
8.5 In the power mains there must be a device that ensures complete disconnection in overvoltage
category III conditions.
9. STARTING UP
9.1
Do not start the pump unless it has been completely filled with
fluid.
Before starting up, check that the pump is properly primed; fill it completely with clean water by
means of the hole provided after having removed the filler cap on the pump body. This ensures
that the mechanical seal is well lubricated and that the pump immediately starts to work regularly.
(Fig. F). Dry operation causes irreparable damage to the mechanical seal. The filling cap
must then be screwed back on carefully.
9.2 Switch on the power and check, on the three-phase version, that the motor is turning in the correct
direction; this should be in a clockwise direction, looking at the motor from the impeller side. Fig.
G If it is turning in the wrong direction, invert the connections of any two wires on the terminal
board, after having disconnected the pump from the power mains.
10. PRECAUTIONS
10.1 The electropump should not be started more than 20 times in one hour so as not to subject the
motor to excessive thermal shock.
10.2 DANGER OF FROST: When the pump remains inactive for a long time at temperatures of less
than 0°C, the pump body must be completely emptied through the drain cap Fig. H, to prevent
possible cracking of the hydraulic components. This operation is advisable even in the event of
prolonged inactivity at normal temperature.
10.3 When starting after long periods of inactivity, the starting-up operations listed above must be
repeated.
11. MAINTENANCE AND CLEANING
In normal operation, the pump does not require any specific maintenance. However,
it may be necessary to clean the hydraulic parts when a fall in yield is observed. The
electropump must not be dismantled unless by skilled personnel in possession of
the qualifications required by the regulations in force. In any case, all repairs and
maintenance jobs must be carried out only after having disconnected the pump from
the power mains.
12. MODIFICATIONS AND SPARE PARTS
Any modification not authorized beforehand relieves the manufacturer of all
responsibility. All the spare parts used in repairs must be original ones and the
accessories must be approved by the manufacturer so as to be able to guarantee
maximum safety of the machines and systems in which they may be fitted.
In the event of damage to the power cable of this appliance, the repair
must be carried out by skilled personnel, in order to prevent all risks.

12.1 Removal and replacement of the supply cable


Before starting, ensure that the electropump is not connected to the power network.
A) For versions without a pressure switch
Remove the condenser cover, unscrewing the four screws on it. Unscrew the three terminals L - N -
and disconnect the brown lead, the blue lead and the yellow-green lead, coming from the supply cable,
after having slackened the grommet.
B) For versions with a SQUARE D pressure switch
 Section of cable with plug from the pressure switch: unscrew the screw from the cover of the pressure
switch using a screwdriver and remove the cover. Remove the yellow-green lead, slackening the earth
screw, the blue lead and the brown lead from the respective terminals at the side, slackening the screws on
the terminals. Remove the cable blocking terminal, slackening the respective screws, and slip off the
cable which is now disconnected.
 Section of cable from the pressure switch to the terminal board: unscrew the nut from the cover of the
pressure switch using a screwdriver and remove the cover. Remove the yellow-green lead, slackening the
earth screw, the blue lead and the brown lead from the respective central terminals, slackening the screws
on the terminals. Remove the cable blocking terminal, slackening the respective screws, and slip off the
cable which is now disconnected. Remove the condenser cover, unscrewing the four screws on it.
9
ENGLISH
Unscrew the three terminals L - N - and disconnect the brown lead, the blue lead and the yellow-green
lead, coming from the pressure switch, after having slackened the grommet.
C) Version with a TELEMECANIQUE / SQUARE D – TELEMECANIQUE / ITALTECNICA
pressure switch:
 Section of cable with plug from the pressure switch: unscrew the screw from the cover of the pressure
switch using a screwdriver and remove the cover, releasing it from the base of the pressure switch. Slip
out the yellow-green lead, unscrewing the earth screw on the left side. Still on the same side, slip the blue
lead and the brown lead off their terminals, slackening the screws on the terminals. Slacken the cable
clamping nut of the pressure switch on the left side and slip off the cable which is now disconnected.
 Section of cable from the pressure switch to the terminal board: unscrew the nut on the cover of the
pressure switch using a screwdriver and remove the cover, releasing it from the base of the pressure
switch. Slip out the yellow-green lead, unscrewing the earth screw on the right side. Still on the same
side, slip the blue lead and the brown lead off their terminals, slackening the screws on the terminals.
Slacken the cable clamping nut of the pressure switch on the right side and slip off the cable which is now
disconnected. Remove the terminal board cover, unscrewing the four screws on it. Unscrew the three
terminals L - N - and disconnect the brown lead, the blue lead and the yellow-green lead, coming from
the supply pressure switch, after having slackened the grommet.

When replacing the power cable, a cable of the same type must be used (e.g. H05 RN-F or H07 RN-F
depending on the installation) and with the same terminals, proceeding as for disassembly in inverse
order.

ATTENTION: depending on the installation and if the pumps have no cable, fit supply cables type
H05 RN-F for indoor use and type H07 RN-F for outdoor use, complete with plug (EN 60335-2-41).
For power cables without a plug, provide a device for cutting off the mains (e.g. magnetothermal
device) with separating contacts of at least 3 mm for each pole.

10
ENGLISH
13. TROUBLESHOOTING

FAUL CHECKS (possible cause) REMEDY


1. The motor does not A. Check the electric connections.
start and makes no B. Check that the motor is live.
noise. C. Check the protection fuses. C. If they are burnt-out, change them.
N.B. If the fault is repeated immediately this
means that the motor is short circuiting.
2. The motor does not A. Ensure that the mains voltage is the same
start but makes noise. as the value on the plate.
B. Ensure that the connections have been B. Correct any errors.
made correctly.
C. Check that all the phases are present on C. If not, restore the missing phase.
the terminal board. (3~)
D. Look for possible blockages in the pump D. Remove the blockage.
or motor.
E. Check the condition of the capacitor. E. Replace the capacitor.
3. The motor turns with A. Check the voltage which may be
difficulty. insufficient.
B. Check whether any moving parts are B. Eliminate the cause of the scraping.
scraping against fixed parts.
4. The pump does not A. The pump has not been primed correctly.
deliver. B. On three-phase motors, check that the B. If necessary, invert the connection of two
direction of rotation is correct. supply wires
C. The diameter of the intake pipe is C. Replace the pipe with one with a larger
insufficient. diameter.
D. Blocked foot valve. D. Clean the foot valve.
5. The pump does not A. The intake pipe or the foot valve is taking A. Eliminate the phenomenon and prime
prime. in air. again.
B. The downward slope of the intake pipe B. Correct the inclination of the intake pipe.
favours the formation of air pockets.
6. The pump supplies A. Blocked foot valve. A. Clean the foot valve.
insufficient flow. B. The impeller is worn or blocked. B. Remove the obstructions or replace the
worn parts.
C. The diameter of the intake pipe is C. Replace the pipe with one with a larger
insufficient. diameter.
D. On three-phase motors, check that the D. If necessary, invert the connection of two
direction of rotation is correct. supply wires.
7. The pump vibrates A. Check that the pump and the pipes are A. Fix the loose parts more carefully.
and operates noisily. firmly anchored.
B. There is cavitation in the pump, that is B. Reduce the intake height or check for
the demand for water is higher than it is load losses.
able to pump.
C. The pump is running above its plate C. It may be useful to limit the flow at
characteristics. delivery.

11
DAB PUMPS LTD. DAB PUMPS IBERICA S.L.
Units 4 and 5, Stortford Hall Industrial Park, Avenida de Castilla nr.1 Local 14
Dunmow Road, Bishops Stortford, Herts 28830 - San Fernando De Henares - Madrid
CM23 5GZ - UK Spain
salesuk@dwtgroup.com info.spain@dwtgroup.com
Tel.: +44 1279 652 776 Ph.: +34 91 6569545
Fax: +44 1279 657 727 Fax: +34 91 6569676

DAB PUMPS B.V. DAB PUMPS B.V.


Brusselstraat 150 Albert Einsteinweg, 4
B-1702 Groot-Bijgaarden - Belgium 5151 DL Drunen - Nederland
info.belgium@dwtgroup.com info.nl@dwtgroup.com
Tel.: +32 2 4668353 Tel.: +31 416 387280
Fax: +32 2 4669218 Fax: +31 416 387299

DAB PUMPS INC. DWT South Africa


3226 Benchmark Drive Podium at Menlyn, 3rd Floor, Unit 3001b,
Ladson, SC 29456 USA 43 Ingersol Road, C/O Lois and Atterbury,
info.usa@dwtgroup.com Menlyn, Pretoria, 0181 South-Africa
Ph. : 1-843-824-6332 info.sa@dwtgroup.com
Toll Free : 1-866-896-4DAB (4322) Tel +27 12 361 3997
Fax : 1-843-797-3366 Fax +27 12 361 3137

OOO DAB PUMPS DAB PUMPEN DEUTSCHLAND GmbH


Novgorodskaya str, 1, bld G, office 308 Tackweg 11
127247 Moscow - Russia D - 47918 Tönisvorst - Germany
info.dwtru@dwtgroup.com info.germany@dwtgroup.com
Tel.: +7 495 122 00 35 Tel.: +49 2151 82136-0
Fax: +7 495 122 00 36 Fax: +49 2151 82136-36

DAB PUMPS POLAND SP. z.o.o. DAB UKRAINE Representative Office


Mokotow Marynarska Regus Horizon Park
ul. Postępu 15C 4M. Hrinchenka St, suit 147
02-676 Warszawa - Poland 03680 Kiev. UKRAINE
Tel. +48 223 81 6085 info.ukraine@dwtgroup.com
Tel. +38 044 391 59 43

DAB PUMPS CHINA DAB PRODUCTION HUNGARY KFT.


No.40 Kaituo Road, Qingdao Economic & H-8800
Technological Development Zone Nagykanizsa, Buda Ernó u.5
Qingdao City, Shandong Province, China Hungary
PC: 266500 Tel. +36.93501700
info.china@dwtgroup.com
Tel.: +8653286812030-6270 DAB PUMPS DE MÉXICO, S.A. DE C.V.
Fax: +8653286812210 Av Gral Álvaro Obregón 270, officina 355
Hipódromo, Cuauhtémoc 06100
México, D.F.
08/16 cod.0013.550.01

Tel. +52 55 6719 0493

DAB PUMPS S.p.A.


Via M. Polo, 14 - 35035 Mestrino (PD) - Italy
Tel. +39 049 5125000 - Fax +39 049 5125950
www.dabpumps.com

You might also like