5
ENGLISH
3
Delivery: from 0,06 to 37 m /h
Head up – Hmax (m): pag. 150
Pumped liquid: clean, free from solid bodies or abrasive substances, non-aggressive.
Degree of motor protection: IP44 (For IP55 see plate on package)
Degree of terminal board protection: IP55
Protection class: F
Cable clamp: PG 11 and/or PG 13.5, depending on models
Line fuses AM class:
Line fuses(Amps)
Model 110V 50Hz 220-240V 50Hz 230 V3 400 V3
115V 60Hz 230V 60Hz 50/60Hz 50/60Hz
127 V 60 Hz
KP 38/18, KP 38/18 Pred., KP 60/6, DP 81, DP 82, AQUADP 82/20 8 4 4 2
K 20/41
KPA 40/20 8 6 4 2
KP 60/12; -- 6 4 4
EURO 40/30-40/306 / 30/50-30/506 / 25/80-25/806 10 6 4 4
EUROINOX 40/30-40/306 / 30/50-30/506 / 25/80-25/806
EUROCOM 25/80-25/806 / 30/50-30/506
EUROCOM SP 30/50-30/506
EURO 25/30-25/306 / 30/30-30/306 8 4 4 4
EUROINOX 25/30-25/306 / 30/30-30/306
EUROCOM 25/30-25/306 / 30/30-30/306
GARDEN-INOX 30/30
EURO 40/50-40/506 / 30/80-30/806 12 6 6 4
EUROINOX 40/50-40/506 / 30/80-30/806
EUROCOM 40/50-40/506 / 30/80-30/806
EUROCOM SP 40/50-40/506
GARDEN-INOX 40/50
EURO 50/50-50/506 / 40/80-40/806 20 8 6 4
EUROINOX 50/50-50/506 / 40/80-40/806
K 12/200, K 30/70, K 35/40, DP 100, DP 102, AQUADP 102/20, KE 35/40 12 6 6 4
K 30/100 16 8 6 4
JET 151, K 35/100 20 10 6 4
K 40/100, K 36/100, K45/50, DP 151, AQUADP 151/40, KE 45/50 20 10 8 4
JET 200, K 14/400 20 10 8 6
JET 251 25 12 8 6
JET 300, K 55/50, DP 251, AQUADP 251/40, KE 55/50 32 16 10 6
Maximun 6 bar (600 kPa): DP 81, DP 82, DP 100, DP 102,
operating pressure: AQUADP 82/20, AQUADP 102/20
EURO, EUROINOX, EUROCOM, EUROCOM SP, GARDEN-INOX
K 35/40, K 35/100, K 40/100, K 20/41, K 30/70, K 30/100, K 36/100, K 12/200, K 14/400,
KE 35/40
7,5 bar (750 kPa): JET 151, JET 251, JET 200, JET 300
DP 151, DP 251, AQUADP 151/40, AQUADP 251/40
8 bar (800 kPa): K 45/50, K 55/50, KE 45/50, KE 55/50
10 bar (1000 kPa): KP 60/6, KP 60/12, KP 38/18
KPA 40/20
Liquid 0 ÷ +35°C: For all homologated pumps
temperature range: EN 60335-2-41 (for domestic uses)
0 ÷ +40°C: JET 151, JET 251, JET 200, JET 300
DP 81, DP 82, DP 100, DP 102, DP 151, DP 251
AQUADP 82/20, AQUADP 102/20, AQUADP 151/40, AQUADP 251/40
-10 ÷ +50°C: K 20/41, K 30/70, K 30/100, K 36/100, K 12/200, K 35/40,
K 45/50, K 35/100, K 40/100
KP 38/18, KE 35/40, KE 45/50
-10 ÷ +80°C: KP 60/6, KP 60/12
KPA 40/20
-15 ÷ +110°C: K 14/400, K 55/50, KE 55/50
6
ENGLISH
Storage temperature: -10°C to +40°C
Relative humidity of the air: MAX. 95%
Noise level: For pumps intended for outdoor use: noise emission according to Directive
2000/14/CE.
For other pumps: noise emission according to Directive EC 89/392/CEE and
subsequent amendments.
Motor construction in conformity with standards CEI 2-3 - CEI 61-69 (EN 60335-2-41).
The leads of the supply cables must have a rated section no smaller than that illustrated in the
following table:
5. MANAGEMENT
5.1 Storage
All the pumps must be stored indoors, in a dry, vibration-free and dust-free environment, possibly with
constant air humidity.
They are supplied in their original packaging and must remain there until the time of installation. If this is
not possible, the intake and delivery aperture must be accurately closed.
5.2 Transport
Avoid subjecting the products to needless jolts or collisions.
To lift and transport the unit, use lifting equipment and the pallet supplied standard (if applicable).
5.3 Weights
The adhesive label on the package indicates the total weight of the electropump.
6. WARNINGS
6.1 Skilled technical personnel
It is advisable that installation be carried out by skilled personnel in possession of
the technical qualifications required by the specific legislation in force.
The term skilled personnel means persons whose training, experience and instruction, as well
as their knowledge of the respective standards and requirements for accident prevention and
working conditions, have been approved by the person in charge of plant safety, authorizing
them to perform all the necessary activities, during which they are able to recognize and avoid
all dangers. (Definition for technical personnel IEC 364).
The appliance is not intended to be used by persons (including children) with reduced physical,
sensory or mental capacities, or who lack experience or knowledge, unless, through the
mediation of a person responsible for their safety, they have had the benefit of supervision or of
instructions on the use of the appliance. Children should be supervised to ensure that they do
not play with the appliance.
7
ENGLISH
6.2 Safety
Use is allowed only if the electric system is in possession of safety precautions in accordance with the
regulations in force in the country where the product is installed (for Italy, CEI 64/2).
6.3 Checking motor shaft rotation
Before installing the pump you must check that the rotating parts turn freely. For this purpose remove the fan
cover from its seat in the motor end cover. Insert a screwdriver in the notch on the motor shaft from the
ventilation side. If there is a blockage, turn the screwdriver, tapping it gently with a hammer. FIG. A
6.4 Responsibility
The Manufacturer does not vouch for correct operation of the pumps if they are
tampered with or modified, run outside the recommended work range or in contrast with
the other instructions given in this manual.
The Manufacturer declines all responsibility for possible errors in this instructions
manual, if due to misprints or errors in copying. The company reserves the right to make
any modifications to products that it may consider necessary or useful, without affecting
the essential characteristics.
7. INSTALLATION
The pumps may contain small quantities of residual water from testing.
We advise flushing them briefly with clean water before their final installation.
7.1 The electropump must be fitted in a well ventilated place, protected from unfavourable weather
conditions and with an environment temperature not exceeding 40°C. Fig.B
7.2 A firm anchoring of the pump to the bearing surface favours the absorption of any vibrations caused
by pump operation. Fig. C
7.3 Ensure that the metal pipes do not exert undue strain on the apertures, thus preventing deformations
or breakages. Fig. C
7.4 It is always good practice to place the pump as close as possible to the liquid to be pumped. The
pump must be installed only in horizontal position. The internal diameters of the pipes must never be
smaller than that of the mouth of the electropump. It is advisable to fit a foot valve on suction. Fig. D
For suction depths of over four metres or with long horizontal stretches it is advisable to use an intake
hose with a diameter larger than that of the intake aperture of the pump. To prevent the formation of air
pockets, the intake hose must slope slightly upwards towards the pump. Fig. D
7.5 If the intake pipe is made of rubber or flexible material, always check that it is of the reinforced type
to avoid throttling due to suction.
7.6 The lifting and carrying handle must always be present and well fixed to the support on all
pumps produced in the portable version.
7.7 Pumps that are to be used in fountains for outdoor use, in garden ponds and similar places,
must be fed by means of a circuit equipped with a differential current device, the rated
operating differential current of which is not higher than 30 mA.
8. ELECTRICAL CONNECTION
Caution! always follow the safety regulations.
Scrupulously follow the wiring diagrams inside the terminal board box.
8.1 Electric installation must be carried out by skilled and authorized electrician who accepts all
the responsibility for the job.
8.2 Ensure that the mains voltage is the same as the value shown on the motor plate and that there is the
possibility of MAKING A GOOD EARTH CONNECTION (Fig. E), in particular the earth
terminal must be connected to the yellow/green lead of the power cable. The earth lead used must
be longer than the phase leads so that it does not disconnect first when subject to traction.
8.3 In fixed installations, International Safety Standards require the use of isolating switches with a
fuse-carrier base.
8.4 Single-phase motors are provided with built-in thermal overload protection and may be connected
directly to the mains. Three-phase motors must be protected with an automatic switch (e.g. overload
protection) set at the values on the electropump data plate, or with fuses of the size indicated in
chapter 4.
8
ENGLISH
8.5 In the power mains there must be a device that ensures complete disconnection in overvoltage
category III conditions.
9. STARTING UP
9.1
Do not start the pump unless it has been completely filled with
fluid.
Before starting up, check that the pump is properly primed; fill it completely with clean water by
means of the hole provided after having removed the filler cap on the pump body. This ensures
that the mechanical seal is well lubricated and that the pump immediately starts to work regularly.
(Fig. F). Dry operation causes irreparable damage to the mechanical seal. The filling cap
must then be screwed back on carefully.
9.2 Switch on the power and check, on the three-phase version, that the motor is turning in the correct
direction; this should be in a clockwise direction, looking at the motor from the impeller side. Fig.
G If it is turning in the wrong direction, invert the connections of any two wires on the terminal
board, after having disconnected the pump from the power mains.
10. PRECAUTIONS
10.1 The electropump should not be started more than 20 times in one hour so as not to subject the
motor to excessive thermal shock.
10.2 DANGER OF FROST: When the pump remains inactive for a long time at temperatures of less
than 0°C, the pump body must be completely emptied through the drain cap Fig. H, to prevent
possible cracking of the hydraulic components. This operation is advisable even in the event of
prolonged inactivity at normal temperature.
10.3 When starting after long periods of inactivity, the starting-up operations listed above must be
repeated.
11. MAINTENANCE AND CLEANING
In normal operation, the pump does not require any specific maintenance. However,
it may be necessary to clean the hydraulic parts when a fall in yield is observed. The
electropump must not be dismantled unless by skilled personnel in possession of
the qualifications required by the regulations in force. In any case, all repairs and
maintenance jobs must be carried out only after having disconnected the pump from
the power mains.
12. MODIFICATIONS AND SPARE PARTS
Any modification not authorized beforehand relieves the manufacturer of all
responsibility. All the spare parts used in repairs must be original ones and the
accessories must be approved by the manufacturer so as to be able to guarantee
maximum safety of the machines and systems in which they may be fitted.
In the event of damage to the power cable of this appliance, the repair
must be carried out by skilled personnel, in order to prevent all risks.
When replacing the power cable, a cable of the same type must be used (e.g. H05 RN-F or H07 RN-F
depending on the installation) and with the same terminals, proceeding as for disassembly in inverse
order.
ATTENTION: depending on the installation and if the pumps have no cable, fit supply cables type
H05 RN-F for indoor use and type H07 RN-F for outdoor use, complete with plug (EN 60335-2-41).
For power cables without a plug, provide a device for cutting off the mains (e.g. magnetothermal
device) with separating contacts of at least 3 mm for each pole.
10
ENGLISH
13. TROUBLESHOOTING
11
DAB PUMPS LTD. DAB PUMPS IBERICA S.L.
Units 4 and 5, Stortford Hall Industrial Park, Avenida de Castilla nr.1 Local 14
Dunmow Road, Bishops Stortford, Herts 28830 - San Fernando De Henares - Madrid
CM23 5GZ - UK Spain
salesuk@dwtgroup.com info.spain@dwtgroup.com
Tel.: +44 1279 652 776 Ph.: +34 91 6569545
Fax: +44 1279 657 727 Fax: +34 91 6569676