HMG PRO
HYDRAULIC MAGNET GENERATORS
HMG PRO 6 KW
HMG PRO 10 KW
HMG PRO 15 KW
HMG PRO 20 KW
OPERATING INSTRUCTIONS
2 February 2014 JLe
HMG PRO HYDRAULIC MAGNET GENERATORS
TABLE OF CONTENTS 2
2. PRODUCT DESCRIPTION 4
3. CONSTRUCTION 4
3.1 Automatic voltage control 4-5
3.2 Classification 5
4. INSTALLATION 5- 9
4.1 Open centre hydraulic system with variable displacement pump 6
4.2 Closed centre hydraulic system with variable displacement pump 6
4.3 Hydraulic system with constant displacement pump 7
4.4 DC voltage verification and adjustment at start-up 7
4.5 Control card settings 8-9
6. OPERATION 12-1
6.1 Hydraulic control 12
6.2 External control 13
6.3 Additional features available under external control 13
7. MAINTENANCE 14-15
9. HYDRAULIC FLUIDS 16
13. PARAMETERS 23
14. WARRANTY 24
16. NOTES 26
3 February 2014 JLe
HMG PRO HYDRAULIC MAGNET GENERATORS
SAFETY PRECATIONS
Operating voltage of HMG PRO-unit varies 110 - 415V depending on generator type.
The hydraulic system is usually pressurised up to 210 (420) bar.
In order to avoid damages and accidents operator and maintenance personal must act in compliance with the
laws, regulations and recommendations issued by local authorities in electricity and high pressure hydraulics.
Prior to detaching a magnet from a carrier, unplug it from a generator’s socket !
Control unit capacitors can develop discharge voltage over 200VDC even the equipment stands still. Wait at
least half an hour (0,5) since capacitors are properly discharged.
TECHNICAL CONDITION OF YOUR MACHINERY AND EQUIPMENT MUST BE SUBJECTED TO CONSTANT
SURVEILLANCE.
Hydraulic system of a carrier machine should be maintained according to the service program. All couplings,
valves and hoses should be maintained, tight and clean as well as kept under constant observation. Leaks in
the hydraulic system must be fixed immediately to avoid injuries caused by high pressure and oil blowouts.
Prior to maintenance, detaching from a carrier or disassembling a DYNASET-unit, the hydraulic system of a
carrier machine should be stopped and DYNASET unit hydraulic circuit depressurized.
Wearers of pacemakers must avoid being magnetic fields
in all possible means. The magnetic fields surrounding a
permanent magnet on all sides can affect and even destroy
sensitive electronic and mechanical measuring equipment.
Please observe sufficient distance (greater than 5 m) from
equipment of this type (including computers, screens, disks,
PACEMAKER MINIMUM BEWARE
SAFETY DISTANCE 5m credit cards, etc.). MAGNETIG FIELD
When operating or maintaining in the immediate vicinity of DYNASET hydraulic generator unit or accessories,
appropriate protective clothing, safety goggles, gloves, ear and eye protection should be worn. Do not touch
parts heated by hydraulic oil.
All installation and service of both hydraulic and electric equipment must be performing experienced personnel
only.
WARNING STICKERS
Dynaset dispatch department includes one (1) warning sticker bag per one (1) main product.
Product recipient is obligated to fix determinate warning sticker to Dynaset product.
Attach sticker to visible and appropriate place or close to Dynaset product where it is easily seen.
Before attaching sticker clean surface with solvent detergent.
READ OPERATING INSTRUCTIONS. GENERAL CAUTION. BEWARE OF HOT SURFACE. USE EAR PROTECTOR AND
BEWARE OF PRESSURE AIR. GLOGGLES
4 February 2014 JLe
HMG PRO HYDRAULIC MAGNET GENERATORS
GENERAL NOTES
DYNASET hydraulic magnet generator of HMG PRO-range, designed for an installation to material handling
machines (hydraulic excavators, heavy trucks with hydraulic cranes), is compact and complete power source for
ferrous metal handling magnet. The only power source is a hydraulic system to provide generator with required
hydraulic fluid flow at demanded pressure.
DYNASET hydraulic magnet generator transforms hydraulic power into high quality electricity, which is used
for energising metal handling magnet. HMG PRO generator is provided with a control unit which allows to use
either hydraulic (= HMG PRO-generator in CMG-mode) or alternatively external electric control (= HMG PRO-
generator in HMG-mode).
An automatic demagnetisation ensures fast disengagement of a picked and moved metal off from a magnet.
DYNASET HMG PRO-generators operate with all 220 VDC metal handling magnets upon condition that
magnet’s coil inductance is 0 ... 20 H.
CONSTRUCTION
DYNASET hydraulic magnet generator is comprised of hydraulic synchronous generator and electric control
unit which includes a rectifier block and operation control automatics. The power-to-weight ratio of DYNASET
hydraulic magnet generator is excellent due to the modern construction. Depending on the type and size,
generator might be designed whether as a single bearing unit or as a bi-bearing machine.
The unit has an automatic rotation-speed control valve with ports for pressure and return lines.
Unit’s rotor, connected to the hydraulic motor’s shaft, is provided with excitation windings.
Electric power is taken from stator windings. Auxiliary winding of voltage control system is located in generator‘s
stator as well. Windings are isolated from unit’s body and their insulation class is H.
Protection class of DYNASET hydraulic magnet generator in standard execution complies with specifications
IP23, electric control unit meets requirements of IP44. Units with protection class IP 54 are available by request.
AC-auxiliary electricity is optional.
Automatic circuit breakers protect unit from overload.
Compound regulator is connected to the auxiliary winding and maintains the output voltage constant through the
entire load range with accuracy of ± 5%. Compound regulator sets the excitation current according to electric
load of each phase with its separate current windings individually. Each phase can be loaded up to maximum
current deliberately.
Performance speed of a compound voltage controls is less than 0,1 sec.
5 February 2014 JLe
HMG PRO HYDRAULIC MAGNET GENERATORS
Q, l/min
0 Qmin Qmax HYDRAULIC FLUID
FLOW
CLASSIFICATION
DYNASET hydraulic generators are manufactured in conformity with the 98/37, 73/23, 89/336 CEE directives
and their amendments. They are also manufactured in compliance with the following regulations: CEI 2-3, EN
60034-1, IEC 34-1, VDE 0530, BS4999-5000, CAN/CSA-C22.2, NF 51.100 and N° 14-95 - N° 100-95.
By request, DYNASET hydraulic generators can be equipped with a radio interference protection to meet
requirements of specifications MIL STD 461 A/B and VDE 0875 class N.
INSTALLATION
DYNASET hydraulic magnet generator works being integrated into an original hydraulic system of a material
handling machine.
Unit can be placed deliberately ensuring an easy access to the unit. Generator should be positioned
horizontally. Additionally, return line must be connected to a hydraulic oil tank in the shortest possible way in
order to keep return oil pressure under 5 bar.
Cooling capacity of hydraulic system, designed for continuous operation (an excavator), is generally sufficient
under proper installation of HMG PRO-generator. An additional oil cooler is required when HMG PRO-unit is
installed to a truck with and hydraulic hoist.
Ensure that the filtration capacity of a hydraulic system is sufficient.
P
T P
INSTALLATION
OPEN CENTRE HYDRAULIC SYSTEM WITH VARIABLE DISPLACEMENT PUMP
The demanded hydraulic flow is to be ensured and controlled with a DYNASET PRESSURE COMPENSATED
PRIORITY VALVE.
DYNASET PV SAE 3/4 - 1 1/4 -XX lpm
- 12/24 V priority valve includes following
components:
AUTIMATIC
1. Sandwich-mounted pressure
ROTATION SPEED compensator with SAE-flange
CONTROL VALVE
specification;
T P 2. Solenoid valve 12/24V;
S 3. Flow limiter;
M 4. Pressure relief valve.
PV SAE priority valve is designed for the
installation to main pressure line between
PV SAE valve
B G SAE-flanges of main hydraulic pump.
Pre-adjusted, independent from other
LS LS
CF HMG PRO functions and prioritised hydraulic flow for
P P DYNASET-unit comes from the solenoid
A valve. The rest of hydraulic pump’s
T capacity is available for all other functions.
Furthermore, pump’s control works
together with DYNASET PV SAE priority
valve.
ALSO AVAILABLE for open centre hydraulic systems with variable displacement pump: PRIORITY VALVE PV
SAE ¾ - 1 ¼ - 12/24 V.
DYNASET PRIORITY VALVES enable to operate your DYNASET-unit simultaneously with other hydraulic
executors.
CLOSED CENTRE HYDRAULIC SYSTEM WITH VARIABLE DISPLACEMENT PUMP
The demanded hydraulic flow is to be ensured and controlled with a DYNASET PRESSURE COMPENSATED
LOAD SENSING (LS) VALVE.
ALSO AVAILABLE for closed centre hydraulic systems with variable displacement pump:
DYNASET SOLENOID VALVE to the pressure line for remote starting.
SV 70 NC - 1/2 - 12 / 24 V max 70 l/min with LS -connection;
SV 150 NC - 1 - 12 / 24 V max 150 l/min with LS -connection.
7 February 2014 JLe
HMG PRO HYDRAULIC MAGNET GENERATORS
INSTALLATION
HYDRAULIC SYSTEM WITH CONSTANT DISPLACEMENT PUMP
T P
Installation with a standard pressure
S compensated 3-way valve should be
avoided in order to close off potential
M
waving in hydraulic system.
1. Ensure that the generator is properly installed and connected to the hydraulic system of your carrier machine
and no hydraulic fluid leakages detect..
2. Start the engine of your carrier machine. Adjust the engine speed to the demanded level if necessary.
3. Start the generator with a ON/OFF switch and turn on the magnet.
4. Read generator’s voltmeter (digital display at control unit’s socket side). Verify the voltage value with an
multimeter from generator’s socket.
5. If voltage reading is out of limits:
5.1 Ensure whether the hydraulic fluid flow is on the demanded level.
5.2 Make setting by adjusting the RPM-cartridge:
2 NOTE !
When making adjustment, the hydraulic fluid should be at normal
operation temperature !
8 February 2014 JLe
HMG PRO HYDRAULIC MAGNET GENERATORS
INSTALLATION
HMG PRO CONTROL CARD SETTINGS
Depending on size of a generator, Pro-control unit can be equipped with more than one control card.
Coil card is used for connection of multiple control cards.
HMG PRO 6 kW
HMG PRO 10 kW CONTROL CARD x 1
HMG PRO 12 kW
HMG PRO 15 kW CONTROL CARD x 2
HMG PRO 20 kW
power reduction
hard
1 4
nor.
nor.
nor.
gen. switch
master
slave
Settings related to the control mode are made with DIP-switches SW1 and SW2, both located on a control
card(s).
ATTENTION !
When HYDRAULIC CONTROL (DIP Switch SW1, switch 4) has been chosen, both hard demagnezation and
power reduction functions are kept disabled.
9
BRN
GRN
WHT
PI
GRY
BRN
GRN
WHT
PI
GRY
output active
display over display
over EM-224di4 temp
temp SNUB. EM-224di4 SNUB.
RES. RES.
12-18ohm 12-18ohm
- + -
gnd
+5V
snubber
+15V
gnd
isp reset
+5V
sck.
miso./reset
mosi
gnd
output active
on/off
shut down
c
temp sens. in
+
demag
magn.
snubber
shut down
+15V
gnd
isp reset
+5V
sck.
miso./reset
mosi
gnd
temp sens. in
demag.
magn.
gnd
27 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 27 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10
9 8 9 8
sck
0V
+5V
sck
0V
+5V
miso
mosi
miso
mosi
snubber snubber
slave
SW1
master
slave
SW1
master
2k2
MASTER
2k2
switch trig. switch trig.
MASTER
fault. fault.
nor,
nor.
nor.
nor,
nor.
nor.
mag.
mag.
4 3 2 1 4 3 2 1
power
power
demag
demag
hard
DC-TERMINAL
hard
DC-TERMINAL
3-ph SUPPLY MAGNET COIL 3-ph SUPPLY MAGNET COIL
(-) (+) (-) (+)
power save
power save
power reduction
power reduction
1 2 3 4 5 6 7 1 2 3 4 5 6 7
- + - +
(-) (+)
L1 L2 L3 MAGNET COIL 3-ph SUPPLY L1 L2 L3 DC-TERMINAL
+
-
+
2 x 2,5
3 x 2,5
3-ph SUPPLY
5 6
HMG PRO CONTROL CARD SETTINGS
INSTALLATION
- + MAGNET COIL
February 2014 JLe
HMG PRO HYDRAULIC MAGNET GENERATORS
10 February 2014 JLe
HMG PRO HYDRAULIC MAGNET GENERATORS
1.1
Magnet’s cable 5m with plug.
HMG PRO 3 kW 5 x 2,5 mm2
HMG PRO 6 kW 5 x 2,5 mm2
HMG PRO 10 kW 5 x 2,5 mm2
YELLOW-GREEN
HMG PRO 12 kW 5 x 6,0 mm2
HMG PRO 3 kW 5 x 16A HMG PRO 15 kW 5 x 6,0 mm2
HMG PRO 6 kW 5 x 16A HMG PRO 20 kW 5 x 10,0 mm2
BROWN
HMG PRO 10 kW 5 x 16A
BLACK
GREY
BLUE
1.3
Cable 20 m from beam’s socket to
a generator’s socket, with plug.
1.2
Socket with a protective cover,
to be fitted to a stub boom.
11 February 2014 JLe
HMG PRO HYDRAULIC MAGNET GENERATORS
WHEN USED AS HYDRAULICALLY CONTROLLED UNIT, DYNASET HMG PRO GENERATOR DOES NOT
REQUIRE ANY ELECTRICAL CONNECTIONS.
UNDER EXTERNAL (ELECTRIC) CONTROL, CONTROL VOLTAGE AND POWER SUPPLY FOR SOLENOID
ON/OFF VALVE SHOULD BE BROUGHT TO A GENERATOR’S CONTROL UNIT.
3
12
12
NO
+ 24V
yellow (blue)
red (white/brown) HMG PRO control wiring kit
includes magnet’s control switch,
generator starting switch, plugs for
red (black)
violet (blue) both generator and solenoid valve,
yellow (brown) magnetisation indicator light and
3
12
black (yellow/green)
cables (5m).
The kit is available by request.
1 23 456
Usually either pull-on switch
yellow (blue)
OR or rocker switch is applied for
red (white/brown) magnet generator’s starting.
Switch is to be placed on a
yellow (blue) dashboard or other suitable place.
red (white/brown)
yellow (blue)
red (white/brown) OR
red (white/brown)
yellow (blue)
AUXILIARY SOLENOID
OPERATION
HYDRAULIC CONTROL
HMG PRO generator is controlled by opening and shutting off the hydraulic flow in the actuating circuit with the
assigned switch - either a push-button switch placed on top of a boom’s control stick (breaker circuit) or foot
switch (tilt bucket circuit).
After having ensured the proper mechanical and hydraulic installation of the HMG PRO unit, plug the magnet
into the generator’s socket with a suitable cable (Dynaset cable kit recommended).
Machine’s engine can be started and magnet moved to the working area. Start the HMG PRO with an assigned
switch. During of generator’s acceleration control card monitors increasing output voltage and engages the
magnet at preset recognition level - magnetization phase (1) begins.
Now the iron scrap can be sorted and picked. Having picked a sufficient amount of scrap, move it to a dump site
(for instance, scrap trailer). HMG’s control switch must be kept pressed down during this procedure.
To halt the HMG PRO, cut off the hydraulic flow by releasing the control switch when the unit stops. Control card
disengages magnet from power supply (i.e. generator) as generator’s output voltage drops to a recognition level
- magnetization phase (1) is over and process of dissipation of magnet’s residual power (2) with subsequent
demagnetization (3) begins.
High voltage capacitors of control unit are charged with a residual energy of magnet and discharged on a
control unit’s thermistor as many times as necessary to discharge the magnet. Having recognised the status of
magnet as discharged, control card changes the polarity of capacitor current executing the demagnetization.
Due to demagnetization, all material being kept by a magnet drops down.
After release of a material, magnet is returned to an iron picking point and the job continues in above sequence.
1 GENERATOR STOPPED
MAGNET ON
U 230 VDC
MAGNET MAGNET
ENGAGED CONTROL CARD’S DISENGAGED
RECOGNITION LEVEL
0
GENERATOR
STARTED
MAGNET
DISCHARGED
2 3
t
OPERATION
EXTERNAL CONTROL
After ensuring the proper installation of the generator, plug magnet’s cable into generator’s socket.
Start machine’s engine.
Direct the hydraulic flow to a generator by opening a solenoid valve, when the control voltage 12/24V, brought
to the control unit, activates (ref. HMG PRO CONTROL WIRING KIT ). Magnet is ready for use when hydraulic
flow achieves a minimal demanded level. GENERATOR ROTATES CONSTANTLY THE PRESSURE LINE
BEING OPEN.
Magnet’s current is switched on by pressing magnet’s control push-button once for less than 0,5 sec, when
control card engages the magnet and material is to be picked and moved. Magnetization indicator light is ON.
Press the push-button sequently for less than 0,5 sec to cut-off magnet’s current (magnetization indicator light
is OFF) and to start dissipation of magnet’s residual power (2) with subsequental demagnetization (3). During
demagnetization an indication light flashes once.
Magnet’s residual power dissipation with demagnetization proceed as described on a previous page.
After release of a material, magnet is returned to an iron picking point and the job continues in above sequence.
MAGNET
ENGAGED 1
MAGNET ON
24 VDC
BUTTON 1 BUTTON 2
MAGNET
DISCHARGED
2 3
t
14 February 2014 JLe
HMG PRO HYDRAULIC MAGNET GENERATORS
OPERATION
Hydraulic pressure is being adjusted according to the
Pressure p, bar
magnet’s power demand, when the hydraulic fluid flow is pmax
being kept constant. pnom
ATTENTION !
Capacitors in control unit keep the charge for a long time
after stopping a generator.
Prior to commence any service:
1. Stop both magnet generator and the carrier 1
2. Wait at least 10 minutes 2
3. Ensure with a gauge that capacitors have no charge.
ATTN. !
Remove side screens (1) and air diffuser (3) to
CLEANLINESS OF YOUR HMG PRO-UNIT MUST BE clean fan compartment as well as rotor and stator.
MAINTAINED ON A REGULAR BASIS. CHECK YOUR Remove cover (2) to dust alternator’s electric
EQUIPMENT AFTER EVERY WORKING SHIFT AND components. Having dusted/cleaned the generator,
DEPENDING ON AN OPERATIONAL ENVIRONMENT replace screens/covers and secure them with
CLEAN A GENERATOR AS FREQUENTLY AS appropriate screws.
NECESSARY TO KEEP IT IN PERFECT WORKING (Above picture for reference only - refer to the data
CONDITION. pages of specific HMG PRO-model).
15 February 2014 JLe
HMG PRO HYDRAULIC MAGNET GENERATORS
MAINTENANCE
Remove all oil deposits. Remove all unnecessary grease and oil from the unit. Accumulated grease and oil can
cause overheating and subsequent generator damage and may present a potential fire hazard. Do not leave in
the generator case or control box anything that does not belong to the assembly.
The tightness of lids and covers as well as of all screw joints must be inspected on a regular basis, for instance
at least once a week or more frequently, if a generator is exposed to a noticeable vibration.
Having carried maintenance or cleaning, NEVER LEAVE ALTERNATOR’S COVER AND/OR ELECTRIC BOX’
COVER UNREPLACED AND UNSECURED ! Condition of any seal / gasket must be inspected and defective
parts replaced.
Phase wire cross section area (S / mm2). Ground wire cross section area (S / mm2).
S ≤ 16 S
16 < S ≤ 35 16
S > 35 S/2
Use ground wire size at least phase wire cross section area.
Depending on operation, conditions Dynaset recommend use larger ground wire size than phase wire cross
section area.
Pay attention in Dynaset HG, HWG, HMG and CMG models used with rubber cushions or plastic pads enough
grounding does not achieve via hydraulic connections. Enough grounding achieves with external galvanic wire.
In fixed installation without rubber cushions or plastic pads we recommend grounding, but it’s not mandatory.
Grounding wire length 500mm ± 100mm, see picture below.
Pay attention in working machine, e.g. a floating electric circuit forms by Dynaset generator installation and
grounding to machine framework.
This circuit is not in galvanic connection to real earth potential instead they have their own potential in
machine’s framework.
16 February 2014 JLe
HMG PRO HYDRAULIC MAGNET GENERATORS
HYDRAULIC FLUIDS
Wide range of standard hydraulic fluids can be used with the DYNASET hydraulic equipment.
Subject to the operating temperature, following mineral hydraulic oils are recommended:
Synthetic and bio-oils can be used as well if their viscosity characteristics and lubricating efficiency are
corresponding to above mineral oils. Automatic transmission fluids and even engine oils can be used, if they are
allowed to be used in hydraulic system of your carrier machine.
Prior to use special hydraulic fluids a with DYNASET equipment, please be kindly requested to contact nearest
DYNASET representative for an advice.
PRODUCT DISPOSAL
Conform to waste legislation, regulations and recommendations in waste disposal and waste recycling
issued by local authorities.
1. Precondition:
Items requiring special handling can normally be done by authorized waste management facility,
if not:
• Separating the base materials, iron, copper, steel, electronics, removing paint, polyester resin,
and insulation tape and/or plastics residues from all components.
• This ‘waste material’ can now be recycled.
Note! Customer can send the DYNASET equipment for reuse or recycling to the Dynaset Oy or to
other location determinate by Dynaset representative.
2
1
MAGNET’S RESISTANCE
Ω (Ohm)
min max
TROUBLESHOOTING
1. 1.1 1.1
MAGNET DOES NOT Magnet unplugged or magnet’s cable Replug the magnet; change the cable if damaged.
WORK damaged.
1.4 1.4
AC-voltage does not come from Check whether there is a 3-phase voltage 150 - 180
generator to the control unit. VAC on terminals 1 (L1), 2 (L2) and 3 (L3) of control
card (cards).
Potential malfunction in hydraulic system.
Potential failure in AC-generator’s windings, brush
gear, excitation rectifier or voltage regulator.
Ref. to the attached troubleshooting for AC-generator.
1.5 1.5
Damaged control wiring (external Check control wiring, especially magnet’s push-button
control). and generator’s starting switch.
Replace damaged parts.
2. 2.1 2.1
IRON DOES NOT Malfunction of control card. Defective card should be replaced.
GET RELEASED
FROM A MAGNET
(DEMAGNETISATION
DOES NOT WORK)
19 February 2014 JLe
HMG PRO HYDRAULIC MAGNET GENERATORS
TROUBLESHOOTING
3. 3.1 3.1.1
MAGNET Magnet keeps working only a short time. Magnet’s power demand exceeds HMG PRO’s output.
MALFUNCTIONS. Generator gets overloaded and stopped..
Choose magnet according to HMG PRO’s power
output.
O.CUR is indicated on a digital display.
O.CUR O.CUR blinks in turn with time indication 3.1.2
countdown from 20 sec to 0 sec. Magnet cables short-circuit.
3.2
Low magnet’s power. 3.2
U.CUR Magnet’s voltage too low:
Does DC-voltage come to magnet’s terminals?
Does AC-voltage come to the control unit?
AC-GENERATOR TROUBLESHOOTING
1. 1.1 1.1.1
LOW OUTPUT VOLTAGE Too low rotation speed of generator. Check first the output frequency. If the frequency is
AT NO LOAD out of range, hydraulic system failure is concerned.
1.1.2
Check whether the hydraulic fluid flow and pressure
are sufficient. Adjust when necessary.
1.1.3
Check the hydraulic motor for possible leakage.
Replace motor if necessary.
1.2 1.2
Excitation rectifier‘s failure. Trace the failure and replace the rectifier.
1.3 1.3
Poor contact in electric system. Check all internal contacts and wiring of the generator.
Check and clean brushes and slip ring
(HMG PRO 6 - 20 kW).
1.4 1.4.1
Voltage regulator’s failure. Check the compound regulator. Replace if broken
(HMG PR0 6 - 20 kW).
1.5 1.5
Winding failure. Check the condition of winding; verify winding’s
resistance with parameters shown in technical
specification and replace if damaged.
ATTENTION !
To avoid damaging the control unit, set the
overload protection switch to OFF-position prior
to measuring winding’s insulation resistance.
2. 2.1 2.1
LOW OUTPUT VOLTAGE The generator is being overloaded. Reduce the load and check the current I (A) to ensure
AT LOAD, WHILE that the proper load is being applied.
NO-LOAD VOLTAGE IS
CORRECT 2.2 2.2.1
Too low rotation speed of generator. Hydraulic pressure insufficient.
2.2.2
Hydraulic system failure to be traced and cleared.
2.2.3
Hydraulic motor worn out. Replace hydraulic motor.
2.3 2.3.1
Voltage regulator’s failure. Check and adjust or replace the compound regulator.
(HMG PRO 6 - 20 kW).
2.3.2
Check resistors of rotor’s current circuit (2 pcs).
21 February 2014 JLe
HMG PRO HYDRAULIC MAGNET GENERATORS
AC-GENERATOR TROUBLESHOOTING
3. 3.1 3.1
EXCITATION FAILURE Rectifier‘s failure. Trace the failure and replace the rectifier.
3.2 3.2.1
Voltage regulator’s failure. Check and adjust or replace the compound regulator
(HMG PRO 6 - 20 kW).
3.3 3.3
Winding failure. Verify the winding resistance with parameters shown in
technical specification and replace if damaged.
3.4 3.4
Poor contact in electric system. Check all internal contacts and wiring of the generator.
Check and clean brushes and slip ring
(HMG PRO 6 - 20 kW).
3.5 3.5
Insufficient residual magnetism. Use external battery of 12 V for 1 - 2 sec to magnetise
the rotor.
4. 4.1 4.1.1
OUTPUT VOLTAGE Instable rotation speed of generator. Check generator’s hydraulics, including automatic
INSTABILITY frequency control valve. Make an adjustment; replace
RPM-cartridge if necessary.
4.1.2
Check whether the hydraulic fluid flow and pressure
are excessive. Adjust when necessary.
4.1.3
Check the hydraulic motor for possible leakage.
Replace motor if necessary.
4.2 4.2
Electronic voltage regulator’s failure Adjust stability of the regulator.
(HMG PRO30 kW). Replace if broken.
4.3 4.3
Poor contact in electric system. Check all internal contacts and wiring of the generator.
Check and clean brushes and slip ring (HMG PRO
6 - 20 kW).
5. 5.1 5.1
ABNORMAL NOISE Bearing failure. Replace broken bearing.
LEVEL
5.2 5.2
Generator is being overloaded. Reduce the load to proper level.
5.3 5.3
Short circuit in powered unit. Check powered unit. Rectify a defect.
5.4 5.4
Foreign items in generator’s casing. Stop generator and hydraulic system. Remove foreign
item from unit.
5.5 5.5
Extremely fluctuating load. Can it be fixed?
22 February 2014 JLe
HMG PRO HYDRAULIC MAGNET GENERATORS
AC-GENERATOR TROUBLESHOOTING
6. 6.1 6.1
OIL LEAKAGES Failure of axial sealing of generator’s Axial sealing of hydraulic motor broken
hydraulic motor. External indication - by reason of EXCESSIVE PRESSURE IN RETURN
hydraulic oil outflow from ventilation LINE.
grids. Rebuild the return line. Maximum allowed pressure in
return line is 5 bar.
Replace axial sealing of generator’s motor.
6.2 6.2
Oil leakage from hydraulic motor. Hydraulic motor worn out and should be replaced.
23 February 2014 JLe
HMG PRO HYDRAULIC MAGNET GENERATORS
TECHNICAL SPECIFICATIONS
POWER CHARACTERISTICS
Generator power, max. kW 6,0 10,0 12,0 15,0 20,0
Magnet coil power, max. kW 5,5 9,5 11 14,5 19,5
Operation voltage V±% 225±%5 225±%5 225±%5 225±%5 225±%5
AC-voltage regulator, automatic COMPOUND-REGULATOR
HYDRAULIC CONNECTIONS
Pressure line P BSP 1/2” BSP 1/2” BSP 3/4” BSP 3/4 ” BSP 3/4”
Return line T BSP 1/2” BSP 1/2” BSP 1” BSP 1” BSP 1”
Serial connection S BSP 3/8” BSP 3/8” BSP 3/8” NO NO
HYDRAULIC REQUIREMENTS
Minimum flow l/min 36 51 61 69 91
Nominal flow l/min 33 48 57 65 86
Maximum flow l/min 62 70 74 95 110
Pressure at nominal power bar 190 190 190 190 190
Maximum pressure bar 210 210 210 210 210
Idle run pressure bar 50 50 40 40 30
OUTLINE DIMENSIONS
Length mm 500 560 560 790 910
Width mm 320 320 460 430 525
Height mm 380 380 370 450 440
EC DECLARATION OF CONFORMITY
We hereby declare that the below-reference product design and manufacturing are in
conformity with the provisions in the Council Directive on mutual approximation
of laws of the Member States on the safety of machines.
If device has changed by someone other than at the hands of manufacturer or his
permission, this declaration is not valid.
YLÖJÄRVI 31.08.2012
DYNASET Oy
Timo Nieminen
R&D Manager
26 February 2014 JLe
HMG PRO HYDRAULIC MAGNET GENERATORS
NOTES